945 resultados para Azocrown ether
Resumo:
This paper describes preliminary work on the generation of synthesis gas from water electrolysis using graphite electrodes without the separation of the generated gases. This is an innovative process, that has no similar work been done earlier. Preliminary tests allowed to establish correlations between the applied current to the electrolyser and flow rate and composition of the generated syngas, as well as a characterisation of generated carbon nanoparticles. The obtained syngas can further be used to produce synthetic liquid fuels, for example, methane, methanol or DME (dimethyl ether) in a catalytic reactor, in further stages of a present ongoing project, using the ELECTROFUEL® concept. The main competitive advantage of this project lies in the built-in of an innovative technology product, from RE (renewable energy) power in remote locations, for example, islands, villages in mountains as an alternative for energy storage for mobility constraints.
Resumo:
Trabalho de Projecto submetido à Escola Superior de Teatro e Cinema para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Teatro - especialização em Artes Performativas/ Escritas de Cena.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica
Resumo:
Amebiasis continues to be of epidemiological importance in underdeveloped countries. Clinical diagnosis and epidemiological setting in a region are based on the fecal microscopic identification of cysts or trophozoites. This procedure requires well trained personnel, is laborious, of low sensitivity and frequently yields false-positives results. The present study was designed to develop an immuno-enzymatic fecal 96 kDa antigen capture test (COPROELISA-Eh) more sensitive and specific than microscopic diagnosis of amebiasis. Triplicates of 177 stool samples processed by the formol-ether concentration method, were defined as positive or negative by three experienced microscopic observers. Another aliquot was submitted to the antigen capture test by a monoclonal antibody against a specific membrane antigen of pathogenic strains of Entamoeba histolytica. Optical densities were interpreted as positive when they exceeded the mean value of negative samples plus two standard deviations. COPROELISA-Eh showed a 94.4% sensitivity, 98.3% specificity, 96.2% positive predictive value and 97.6% negative predictive value for the detection of E. histolytica in feces. COPROELISA-Eh is more sensitive and specific than microscopic examination, does not require specially trained personnel and allows the simultaneous processing of a large number of samples.
Resumo:
O conforto é uma necessidade para a maioria das pessoas. A busca de vestuário que se adapte às condições ambientais tornou-se essencial. Queremos materiais que nos mantenham quentes ou frescos, em condições de frio ou calor, e sejam capazes de nos manter secos se chover, ou se transpirarmos, devido a actividade intensa, ou simplesmente porque está quente. O objectivo principal deste trabalho era desenvolver uma estrutura multicamada respirável, para posterior aplicação num sapato perfurado, tornando-o respirável e impermeável. São já aplicados em peças de roupa e calçado, materiais que permitem essa gestão de calor e humidade – as membranas. Neste trabalho, foram apresentadas algumas membranas, de fabricantes e materiais diferentes, que foram testadas de modo a obter valores para a transmissão de vapor de água e classificá-las quanto à sua respirabilidade, relativamente a uma membrana de referência. Foram feitos testes com as membranas isoladas, laminadas e com sobreposição de duas membranas laminadas. Verificou-se que a laminagem não diminuía, substancialmente, a respirabilidade das membranas. Já a sobreposição de membranas, demonstrou diminuir em 35 % a respirabilidade das membranas. A membrana com melhor desempenho é constituída por um polímero de base éter e blocos de amida (PEBA). Ainda pouco aplicado em vestuário e calçado, mas com algum potencial, são os não-tecidos impregnados com polímeros super absorventes (SAP’s). Estes podem absorver até 500 vezes o seu peso em água, dependendo da quantidade de SAP’s com que o não tecido é impregnado e da aplicação final. Esta capacidade de adsorção seria uma mais-valia, em condições de chuva intensa, mas por outro lado, se atingir a saturação, não permite a entrada ou saída de ar, o que poderia levar a desconforto no utilizador. Por fim, foi utilizado um manequim térmico (pé), onde se testaram diferentes calçados, verificando-se que só é possível perder calor e vapor de água pela sola do sapato se esta se encontrar perfurada e utilizar um sistema respirável. Futuramente, pretende-se aplicar uma outra camada de não-tecido, na outra face das membranas já testadas, de modo a criar um sistema de 3 camadas, e testar a sua respirabilidade. Sugere-se, também, criar uma estrutura sólida e arejada para utilizar os não-tecidos impregnados em SAPs. Posteriormente, deve-se aplicar estas estruturas num sapato com a sola perfurada e testá-las no manequim térmico.
Resumo:
A indústria dos curtumes é uma das indústrias mais antigas e tradicionais de Portugal e é também uma das mais poluentes. Esta indústria produz muitos resíduos sólidos, entre os quais, está o pelo de bovino. A valorização deste resíduo permite reduzir o impacto ambiental e aumentar a eco-eficiência da indústria dos curtumes. O pelo de bovino, rico em queratina, é um bom candidato para a produção de biofilmes. O objetivo deste trabalho foi a valorização de um resíduo de indústria de curtume (pelo de bovino) através da produção de filmes à base de queratina por termocompressão. Foi estudada a melhor formulação e as condições operatórias mais favoráveis com a finalidade de melhorar as propriedades mecânicas dos filmes. O trabalho realizado durante este projeto dividiu-se em 5 partes: preparação do material, caracterização do material, seleção do pré-tratamento, produção de filmes e caracterização dos filmes. Foram produzidos filmes para a seleção do pré-tratamento e para a respetiva caracterização. Os pré-tratamentos testados foram: tratamento com detergente, tratamento com detergente e sulfureto de sódio e, tratamento com detergente e éter de petróleo. O pré-tratamento selecionado foi o tratamento com detergente. Para a produção de filmes para a posterior caracterização, foram escolhidos 4 conjuntos de condições operatórias diferentes: 160 oC – 147 kN – 8 min – 30% glicerol; 160 oC – 147 kN – 12 min – 30% glicerol; 160 oC – 147 kN – 8 min – 40% glicerol; 160 oC – 147 kN – 12 min – 40% glicerol; identificados como Conjuntos A, B, C e D, respetivamente. Na caracterização dos filmes foram analisados vários parâmetros, nomeadamente a espessura, a permeabilidade ao vapor de água ao vapor de água, as isotérmicas de sorção, a cor, a solubilidade e as propriedades mecânicas. Também foram feitas as análises de calorimetria diferencial de varrimento (DSC) e microscopia eletrónica de varrimento (SEM). Concluiu-se que os filmes do conjunto A (160 oC – 147 kN – 8 min – 30% glicerol) tiveram um melhor desempenho apresentando espessuras médias de 0,25 0,02 mm, permeabilidade ao vapor de água ao vapor de água igual a 1,20 x 10-8 6,79 x 10-10 g/(m.s.Pa), solubilidade igual a 27,9 0,4 %, tensão de rutura média igual a 9,23 1,19 N/mm2, deformação na rutura média igual a 1,9 0,2 % e módulo de elasticidade médio igual a 554 26 N/mm2. Verificou-se um bom ajuste do modelo de GAB aos resultados experimentais. A análise DSC indicou uma temperatura de fusão aos 170 ºC para a mistura de pelo e glicerol que não se verificou nos filmes formados e indicou a temperatura de degradação do material por volta dos 240-250 ºC. A análise SEM mostrou que os filmes não estão totalmente fundidos e provou a irregularidade da superfície dos mesmos. Provou-se que é possível a produção de filmes de pelo bovino sendo ainda necessário melhorar o processo de mistura do pelo com o glicerol.
Resumo:
Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.
Resumo:
A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.
Resumo:
A new biomimetic sensor for leucomalachite green host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted in methacrylic acid or acrylamido-2-methyl-1-propanesulfonic acid-based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and trapped in poly(vinyl chloride). The potentiometric sensors exhibited a near-Nernstian response in steady state evaluations, with slopes and detection limits ranging from 45.8 to 81.2 mV and 0.28 to 1.01 , respectively. They were independent from the pH of test solutions within 3 to 5. Good selectivity was observed towards drugs that may contaminate water near fish cultures, such as oxycycline, doxycycline, enrofloxacin, trimethoprim, creatinine, chloramphenicol, and dopamine. The sensors were successfully applied to field monitoring of leucomalachite green in river samples. The method offered the advantages of simplicity, accuracy, applicability to colored and turbid samples, and automation feasibility.
Resumo:
The formalin-Tween sedimentation method was compared with the formalin-ether sedimentation for parasitic detection. Of a total 297 fecal specimens examined, 72.1% were positive. The formalin-tween technique was effective for ascertaining helminths, particularly Ascaris lumbricoides, Trichuris trichiura and hookworm eggs; however it has less capability for protozoa detection. This method is simple, inexpensive, less time consuming and highly sensitive when detecting the parasitic infection, particularly when focusing on helminth eggs.
Resumo:
Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.
Resumo:
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.
Resumo:
A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.
Resumo:
A 3D-mirror synthetic receptor for ciprofloxacin host–guest interactions and potentiometric transduction is presented. The host cavity was shaped on a polymeric surface assembled with methacrylic acid or 2-vinyl pyridine monomers by radical polymerization. Molecularly imprinted particles were dispersed in 2-nitrophenyl octyl ether and entrapped in a poly(vinyl chloride) matrix. The sensors exhibited a near-Nernstian response in steady state evaluations. Slopes and detection limits ranged from 26.8 to 50.0 mV decade−1 and 1.0 × 10−5 to 2.7 × 10−5 mol L−1, respectively. Good selectivity was observed for trimethoprim, enrofloxacin, tetracycline, cysteine, galactose, hydroxylamine, creatinine, ammonium chloride, sucrose, glucose, sulphamerazine and sulfadiazine. The sensors were successfully applied to the determination of ciprofloxacin concentrations in fish and in pharmaceuticals. The method presented offered the advantages of simplicity, accuracy, applicability to colored and turbid samples and automation feasibility, as well as confirming the use of molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.
Resumo:
Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mV/Δlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL−1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ± 0.7%), fast response, good sensitivity (47 mV/Δlog([ENR]/M), wide linear range (1.0 × 10−5–1.0 × 10−3 M), low detection limit (0.9 µg mL−1), and a stable baseline for a 5 × 10−2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.