836 resultados para Autonomous Loading Controller


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study assessed growth and physiological parameters of 'Sunrise Golden' and 'Tainung 01' papaya seedlings grown in 280mL plastic tubes and watered using a low-cost automatic irrigation system adjusted to operate at substrate water tension for starting irrigation (STI) of 3.0, 6.0 or 9.0 kPa. The water depths applied by the dripping system and drainage were monitored during germination and seedling growth. Germination, emergence velocity index (EVI), leaf area, plant height, shoot and root dry weight, stomatal conductance, relative water content (RWC) and relative chlorophyll content (RCC) were evaluated. Soil nutrient levels were determined by electrical conductivity (EC). Water use efficiency (WUE) corresponded to the ratio of plant dry mass to depth of water applied. STI settings did not affect papaya germination or EVI. System configuration to 3.0 and 6.0 kPa STI exhibited the highest drainage and lowest EC and RCC, indicating soil nutrient loss and plant nutrient deficiency. Drainage was greater in tubes planted with the 'Tainung 01' variety, which developed smaller root systems and lower stomatal conductance than 'Sunrise Golden' seedlings. The highest values for shoot dry weight and WEU were obtained at 6.0 kPa STI for 'Sunrise Golden' (0.62 g and 0.69 g L-1) and at 9.0 kPa in 'Tainung 01' (0.35 g and 0.82 g L-1). RWC at 9.0 kPa STI was lower than at 3.0 kPa in both varieties. The results indicate that the low-cost technology developed for irrigation automation is promising. Even so, new studies are needed to evaluate low-flow irrigation systems as well as the nutrient and water needs of different papaya varieties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article is to provide policy guidance on how to assess the capacity of minor adolescents for autonomous decision-making without a third party authorization, in the field of clinical care. In June 2014, a two-day meeting gathered 20 professionals from all continents, working in the field of adolescent medicine, neurosciences, developmental and clinical psychology, sociology, ethics, and law. Formal presentations and discussions were based on a literature search and the participants' experience. The assessment of adolescent decision-making capacity includes the following: (1) a review of the legal context consistent with the principles of the Convention on the Rights of the Child; (2) an empathetic relationship between the adolescent and the health care professional/team; (3) the respect of the adolescent's developmental stage and capacities; (4) the inclusion, if relevant, of relatives, peers, teachers, or social and mental health providers with the adolescent's consent; (5) the control of coercion and other social forces that influence decision-making; and (6) a deliberative stepwise appraisal of the adolescent's decision-making process. This stepwise approach, already used among adults with psychiatric disorders, includes understanding the different facets of the given situation, reasoning on the involved issues, appreciating the outcomes linked with the decision(s), and expressing a choice. Contextual and psychosocial factors play pivotal roles in the assessment of adolescents' decision-making capacity. The evaluation must be guided by a well-established procedure, and health professionals should be trained accordingly. These proposals are the first to have been developed by a multicultural, multidisciplinary expert panel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. All cases were planned and operated upon with the guided surgery technique. Results: A total of 122 implants were placed in 14 males and 5 females. The intraoperative surgical complications comprised a lack of primary stability, while the postoperative complications consisted of infections and a lack of implant osteointegration. Ten implants failed. The prosthetic complications in turn comprised loosening of the provisional prosthesis screws, prosthesis tooth fracture, and a lack of passive fit of the immediate prosthesis. The degree of patient satisfaction was evaluated using a verbal scale. Conclusions: Implant restoration with the guided surgery technique and immediate functional loading is a predictable procedure, provided patient selection and the surgical technique are adequate, affording lesser postoperative morbidity and increased patient satisfaction thanks to the immediate restoration of esthetics and function

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The time required to image large samples is an important limiting factor in SPM-based systems. In multiprobe setups, especially when working with biological samples, this drawback can make impossible to conduct certain experiments. In this work, we present a feedfordward controller based on bang-bang and adaptive controls. The controls are based in the difference between the maximum speeds that can be used for imaging depending on the flatness of the sample zone. Topographic images of Escherichia coli bacteria samples were acquired using the implemented controllers. Results show that to go faster in the flat zones, rather than using a constant scanning speed for the whole image, speeds up the imaging process of large samples by up to a 4x factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to show that bone strains due to dynamic mechanical loading during physical activity can be analysed using the flexible multibody simulation approach. Strains within the bone tissue play a major role in bone (re)modeling. Based on previous studies, it has been shown that dynamic loading seems to be more important for bone (re)modeling than static loading. The finite element method has been used previously to assess bone strains. However, the finite element method may be limited to static analysis of bone strains due to the expensive computation required for dynamic analysis, especially for a biomechanical system consisting of several bodies. Further, in vivo implementation of strain gauges on the surfaces of bone has been used previously in order to quantify the mechanical loading environment of the skeleton. However, in vivo strain measurement requires invasive methodology, which is challenging and limited to certain regions of superficial bones only, such as the anterior surface of the tibia. In this study, an alternative numerical approach to analyzing in vivo strains, based on the flexible multibody simulation approach, is proposed. In order to investigate the reliability of the proposed approach, three 3-dimensional musculoskeletal models where the right tibia is assumed to be flexible, are used as demonstration examples. The models are employed in a forward dynamics simulation in order to predict the tibial strains during walking on a level exercise. The flexible tibial model is developed using the actual geometry of the subject’s tibia, which is obtained from 3 dimensional reconstruction of Magnetic Resonance Images. Inverse dynamics simulation based on motion capture data obtained from walking at a constant velocity is used to calculate the desired contraction trajectory for each muscle. In the forward dynamics simulation, a proportional derivative servo controller is used to calculate each muscle force required to reproduce the motion, based on the desired muscle contraction trajectory obtained from the inverse dynamics simulation. Experimental measurements are used to verify the models and check the accuracy of the models in replicating the realistic mechanical loading environment measured from the walking test. The predicted strain results by the models show consistency with literature-based in vivo strain measurements. In conclusion, the non-invasive flexible multibody simulation approach may be used as a surrogate for experimental bone strain measurement, and thus be of use in detailed strain estimation of bones in different applications. Consequently, the information obtained from the present approach might be useful in clinical applications, including optimizing implant design and devising exercises to prevent bone fragility, accelerate fracture healing and reduce osteoporotic bone loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to assess the safety of the concurrent administration of a clopidogrel and prasugrel loading dose in patients undergoing primary percutaneous coronary intervention. BACKGROUND: Prasugrel is one of the preferred P2Y12 platelet receptor antagonists for ST-segment elevation myocardial infarction patients. The use of prasugrel was evaluated clinically in clopidogrel-naive patients. METHODS: Between September 2009 and October 2012, a total of 2,023 STEMI patients were enrolled in the COMFORTABLE (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI]) and the SPUM-ACS (Inflammation and Acute Coronary Syndromes) studies. Patients receiving a prasugrel loading dose were divided into 2 groups: 1) clopidogrel and a subsequent prasugrel loading dose; and 2) a prasugrel loading dose. The primary safety endpoint was Bleeding Academic Research Consortium types 3 to 5 bleeding in hospital at 30 days. RESULTS: Of 2,023 patients undergoing primary percutaneous coronary intervention, 427 (21.1%) received clopidogrel and a subsequent prasugrel loading dose, 447 (22.1%) received a prasugrel loading dose alone, and the remaining received clopidogrel only. At 30 days, the primary safety endpoint was observed in 1.9% of those receiving clopidogrel and a subsequent prasugrel loading dose and 3.4% of those receiving a prasugrel loading dose alone (adjusted hazard ratio [HR]: 0.57; 95% confidence interval [CI]: 0.25 to 1.30, p = 0.18). The HAS-BLED (hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, labile international normalized ratio, elderly, drugs/alcohol concomitantly) bleeding score tended to be higher in prasugrel-treated patients (p = 0.076). The primary safety endpoint results, however, remained unchanged after adjustment for these differences (clopidogrel and a subsequent prasugrel loading dose vs. prasugrel only; HR: 0.54 [95% CI: 0.23 to 1.27], p = 0.16). No differences in the composite of cardiac death, myocardial infarction, or stroke were observed at 30 days (adjusted HR: 0.66, 95% CI: 0.27 to 1.62, p = 0.36). CONCLUSIONS: This observational, nonrandomized study of ST-segment elevation myocardial infarction patients suggests that the administration of a loading dose of prasugrel in patients pre-treated with a loading dose of clopidogrel is not associated with an excess of major bleeding events. (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI] [COMFORTABLE]; NCT00962416; and Inflammation and Acute Coronary Syndromes [SPUM-ACS]; NCT01000701).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automated Fiber Placement is being extensively used in the production of major composite components for the aircraft industry. This technology enables the production of tow-steered panels, which have been proven to greatly improve the structural efficiency of composites by means of in-plane stiffness variation and load redistribution. However, traditional straight-fiber architectures are still preferred. One of the reasons behind this is related to the uncertainties, as a result of process-induced defects, in the mechanical performance of the laminates. This experimental work investigates the effect of the fiber angle discontinuities between different tow courses in a ply on the un-notched and open-hole tensile strength of the laminate. The influence of several manufacturing parameters are studied in detail. The results reveal that 'ply staggering' and '0% gap coverage' is an effective combination in reducing the influence of defects in these laminates

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Behavior-based navigation of autonomous vehicles requires the recognition of the navigable areas and the potential obstacles. In this paper we describe a model-based objects recognition system which is part of an image interpretation system intended to assist the navigation of autonomous vehicles that operate in industrial environments. The recognition system integrates color, shape and texture information together with the location of the vanishing point. The recognition process starts from some prior scene knowledge, that is, a generic model of the expected scene and the potential objects. The recognition system constitutes an approach where different low-level vision techniques extract a multitude of image descriptors which are then analyzed using a rule-based reasoning system to interpret the image content. This system has been implemented using a rule-based cooperative expert system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous silicon (PSi) is a promising material to be utilized in drug delivery formulations. The release rate of the drug compound can be controlled by changing the pore properties and surface chemistry of PSi. The loading of a poorly soluble drug into mesoporous silicon particles enhances its dissolution in the body. The drug loading is based on adsorption. The attainable maximum loaded amount depends on the properties of the drug compound and the PSi material, and on the process conditions. The loading solvent also essentially affects the adsorption process. The loading of indomethacin into PSi particles with varying surface modification was studied. Solvent mixtures were applied in the loading, and the loaded samples were analyzed with thermal analysis methods. The best degree of loading was obtained using a mixture of dichloromethane and methanol. The drug loads varied from 7.7 w-% to 26.8 w-%. A disturbing factor in the loading experiments was the tendency of indomethacin to form solvates with the solvents applied. In addition, the physical form and stability of indomethacin loaded in PSi and silica particles were studied using Raman spectroscopy. In the case of silica, the presence of crystalline drug as well as the polymorph form can be detected, but the method proved to be not applicable for PSi particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article is to offer a practical approach to the new European dimension for regional parliaments signified by the entry into force of the Treaty of Lisbon. The parliamentary scrutiny of subsidiarity by way of the early warning system has assigned a new mission to legislative assemblies with the aim of reinforcing the intervention of regions in the drafting of policies by Union institutions. In the Spanish case, the institutionalisation of this mechanism came about with Act nº 24/2009, which attributes to the Joint Committee for the European Union, in the name of the Cortes Generales [the Spanish Parliament], the function of receiving the proposals for legislative acts by the EU and transferring them to the regional parliaments in order for the latter to issue, in a brief period of four weeks, a report on compliance with the principle of subsidiarity. The majority of regional parliaments have also carried out normative reforms to regulate the procedure of participation in the early warning system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The referendum is a poorly used mechanism for direct participation in the Spanish system, at both state and regional level. The discussion on the feasibility of this system at regional level has been examined by the Constitutional Court. Influenced by the reluctance with which constituents viewed the mechanisms of direct democracy, they still have a reductive view of the referendum. The State therefore reserves the right to exercise very intensive controls on the provision and authorization of referendums and on the specific exercise of each referendum

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This master’s thesis is focused on the active magnetic bearings control, specifically the robust control. As carrying out of such kind of control used mixed H2/Hinf controller. So the goal of this work is to design it using Robust Control Toolbox™ in MATLAB and compare it performance and robustness with Hinf robust controller characteristics. But only one degree-of-freedom controller considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of Group VIII metal catalysts was obtained for the semi-hydrogenation of styrene. Catalysts were characterized by Hydrogen Chemisorption, TPR and XPS. Palladium, rhodium and platinum low metal loading prepared catalysts presented high activity and selectivity (ca. 98%) during the semi-hydrogenation of styrene, being palladium the most active catalyst. The ruthenium catalyst also presented high selectivity (ca. 98%), but the lowest activity. For the palladium catalyst, the influence of the precursor salt and of the reduction temperature on the activity and selectivity were studied. The following activity series was obtained: PdN-423 > PdCl-673 > PdCl-373> PtCl-673 > RhCl-673 >> RuCl-673. As determined by XPS, differences in activity could be attributed, at least in part, to electronic effects.