1000 resultados para Automatization, VI coding, calibration, hot wire anemometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In distributed video coding, motion estimation is typically performed at the decoder to generate the side information, increasing the decoder complexity while providing low complexity encoding in comparison with predictive video coding. Motion estimation can be performed once to create the side information or several times to refine the side information quality along the decoding process. In this paper, motion estimation is performed at the decoder side to generate multiple side information hypotheses which are adaptively and dynamically combined, whenever additional decoded information is available. The proposed iterative side information creation algorithm is inspired in video denoising filters and requires some statistics of the virtual channel between each side information hypothesis and the original data. With the proposed denoising algorithm for side information creation, a RD performance gain up to 1.2 dB is obtained for the same bitrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-density parity-check (LDPC) codes are nowadays one of the hottest topics in coding theory, notably due to their advantages in terms of bit error rate performance and low complexity. In order to exploit the potential of the Wyner-Ziv coding paradigm, practical distributed video coding (DVC) schemes should use powerful error correcting codes with near-capacity performance. In this paper, new ways to design LDPC codes for the DVC paradigm are proposed and studied. The new LDPC solutions rely on merging parity-check nodes, which corresponds to reduce the number of rows in the parity-check matrix. This allows to change gracefully the compression ratio of the source (DCT coefficient bitplane) according to the correlation between the original and the side information. The proposed LDPC codes reach a good performance for a wide range of source correlations and achieve a better RD performance when compared to the popular turbo codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 9.9 kb DNA fragment from the right arm of chromosome VII of Saccharomyces cerevisiae has been sequenced and analysed. The sequence contains four open reading frames (ORFs) longer than 100 amino acids. One gene, PFK1, has already been cloned and sequenced and the other one is the probable yeast gene coding for the beta-subunit of the succinyl-CoA synthetase. The two remaining ORFs share homology with the deduced amino acid sequence (and their physical arrangement is similar to that) of the YHR161c and YHR162w ORFs from chromosome VIII.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objectivo do presente trabalho foi caracterizar os condensados produzidos numa fábrica de pasta para papel para identificar e localizar pontos da sua contaminação. Para o efeito, foram recolhidas amostras de condensado e caracterizados os parâmetros condutividade, pH, sódio e sílica. A amostragem decorreu no período entre 15 de Setembro a 6 de Novembro de 2008. Através da análise dos resultados obtidos para as concentrações de sílica e de sódio de cada uma das correntes, foram identificadas como contaminadas as correntes de condensado provenientes do condensador do Turbogerador 4, da área dos Digestores Descontínuos, da Evaporação e do Aquecedor de Água Quente para o Branqueamento. A realização de um balanço pontual à sílica no tanque de condensados da Central permitiu concluir que a maior contribuição advém do condensador do Turbogerador 4. Na Evaporação ocorre contaminação do condensado quando as secções do Concentrador 1 são colocadas em serviço após lavagem. Durante o acompanhamento do arranque da Evaporação, uma das secções (1/B) registou um valor máximo na concentração de sódio no condensado de 135 mg/L Na. Do estudo resulta, enquanto não for reparado e/ou substituído o equipamento responsável pelas contaminações, a necessidade de admitir requisitos para controlo da qualidade da água da caldeira menos restritivos, nomeadamente para a razão sódio/fosfato. É necessário, contudo, o rigoroso acompanhamento da qualidade da água da caldeira (pH, sobretudo) para prevenir afastamentos inesperados dos limites de controlo. Durante a realização deste trabalho foram identificadas algumas situações a melhorar, tais como a uniformização dos valores de desvio para esgoto dos condensados e das unidades utilizadas, a adequação das escalas dos aparelhos de medida para as gamas de leitura de interesse, a verificação e calibração periódica do equipamento instalado em linha, a adopção do parâmetro “Sódio” para controlo da qualidade dos condensados, a instalação de sistemas de amostragem com arrefecimento em todas as correntes de condensados e a reparação ou substituição de algum equipamento instalado em linha que se encontra em muito mau estado e ainda a manutenção do equipamento mantendo-o em boas condições de limpeza.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta publicação contém as comunicações apresentadas no VI Encontro do CIED – I Encontro Internacional em Estudos Educacionais. Avaliação: Desafios e Riscos, nos dias 15 e 16 de novembro de 2013, na Escola Superior de Educação de Lisboa, Instituto Politécnico de Lisboa, organizado pelo CIED, com o apoio da Escola Superior de Educação de Lisboa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero valent iron (ZVI) has been extensively used as a reactive medium for the reduction of Cr(VI) to Cr(III) in reactive permeable barriers. The kinetic rate depends strongly on the superficial oxidation of the iron particles used and the preliminary washing of ZVI increases the rate. The reaction has been primarily modelled using a pseudo-first-order kinetics which is inappropriate for a heterogeneous reaction. We assumed a shrinking particle type model where the kinetic rate is proportional to the available iron surface area, to the initial volume of solution and to the chromium concentration raised to a power ˛ which is the order of the chemical reaction occurring at surface. We assumed α= 2/3 based on the likeness to the shrinking particle models with spherical symmetry. Kinetics studies were performed in order to evaluate the suitability of this approach. The influence of the following parameters was experimentally studied: initial available surface area, chromium concentration, temperature and pH. The assumed order for the reaction was confirmed. In addition, the rate constant was calculated from data obtained in different operating conditions. Digital pictures of iron balls were periodically taken and the image treatment allowed for establishing the time evolution of their size distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In visual sensor networks, local feature descriptors can be computed at the sensing nodes, which work collaboratively on the data obtained to make an efficient visual analysis. In fact, with a minimal amount of computational effort, the detection and extraction of local features, such as binary descriptors, can provide a reliable and compact image representation. In this paper, it is proposed to extract and code binary descriptors to meet the energy and bandwidth constraints at each sensing node. The major contribution is a binary descriptor coding technique that exploits the correlation using two different coding modes: Intra, which exploits the correlation between the elements that compose a descriptor; and Inter, which exploits the correlation between descriptors of the same image. The experimental results show bitrate savings up to 35% without any impact in the performance efficiency of the image retrieval task. © 2014 EURASIP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As high dynamic range video is gaining popularity, video coding solutions able to efficiently provide both low and high dynamic range video, notably with a single bitstream, are increasingly important. While simulcasting can provide both dynamic range videos at the cost of some compression efficiency penalty, bit-depth scalable video coding can provide a better trade-off between compression efficiency, adaptation flexibility and computational complexity. Considering the widespread use of H.264/AVC video, this paper proposes a H.264/AVC backward compatible bit-depth scalable video coding solution offering a low dynamic range base layer and two high dynamic range enhancement layers with different qualities, at low complexity. Experimental results show that the proposed solution has an acceptable rate-distortion performance penalty regarding the HDR H.264/AVC single-layer coding solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In video communication systems, the video signals are typically compressed and sent to the decoder through an error-prone transmission channel that may corrupt the compressed signal, causing the degradation of the final decoded video quality. In this context, it is possible to enhance the error resilience of typical predictive video coding schemes using as inspiration principles and tools from an alternative video coding approach, the so-called Distributed Video Coding (DVC), based on the Distributed Source Coding (DSC) theory. Further improvements in the decoded video quality after error-prone transmission may also be obtained by considering the perceptual relevance of the video content, as distortions occurring in different regions of a picture have a different impact on the user's final experience. In this context, this paper proposes a Perceptually Driven Error Protection (PDEP) video coding solution that enhances the error resilience of a state-of-the-art H.264/AVC predictive video codec using DSC principles and perceptual considerations. To increase the H.264/AVC error resilience performance, the main technical novelties brought by the proposed video coding solution are: (i) design of an improved compressed domain perceptual classification mechanism; (ii) design of an improved transcoding tool for the DSC-based protection mechanism; and (iii) integration of a perceptual classification mechanism in an H.264/AVC compliant codec with a DSC-based error protection mechanism. The performance results obtained show that the proposed PDEP video codec provides a better performing alternative to traditional error protection video coding schemes, notably Forward Error Correction (FEC)-based schemes. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No literature data above atmospheric pressure could be found for the viscosity of TOTIVI. As a consequence, the present viscosity results could only be compared upon extrapolation of the vibrating wire data to 0.1 MPa. Independent viscosity measurements were performed, at atmospheric pressure, using an Ubbelohde capillary in order to compare with the vibrating wire results, extrapolated by means of the above mentioned correlation. The two data sets agree within +/- 1%, which is commensurate with the mutual uncertainty of the experimental methods. Comparisons of the literature data obtained at atmospheric pressure with the present extrapolated vibrating-wire viscosity measurements have shown an agreement within +/- 2% for temperatures up to 339 K and within +/- 3.3% for temperatures up to 368 K. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O VI par craniano, é responsável pela inervação do músculo recto externo. Uma lesão que afecta o VI par irá resultar numa limitação da abdução. A Síndrome de Duane, do tipo I, caracteriza-se por limitação da abdução unilateral, em que o olho afectado não passa da linha média, por retração do globo ocular e estreitamento da fenda palpebral, em adução. O diagnóstico diferencial é de extrema importância para se proceder a um prognóstico correcto e respectivo plano terapêutico. Objectivos: Esquematizar as diversas características motoras e sensoriais da paralisia do VI par craniano comparando-as com as da Síndrome de Duane Tipo I, designando os testes de ortóptica respectivos. Identificar os testes de diagnóstico diferencial entre as duas entidades e as suas características principais, nomeadamente os exames coordimétricos e o teste das ducções forçadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we calibrate the Vasicek interest rate model under the risk neutral measure by learning the model parameters using Gaussian processes for machine learning regression. The calibration is done by maximizing the likelihood of zero coupon bond log prices, using mean and covariance functions computed analytically, as well as likelihood derivatives with respect to the parameters. The maximization method used is the conjugate gradients. The only prices needed for calibration are zero coupon bond prices and the parameters are directly obtained in the arbitrage free risk neutral measure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronics Letters Vol.38, nº 19

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presença da Desnutrição Protéico-Calórica tem sido expressiva no país, retratando diferenças sociais e econômicas das distintas regiões. Como parte da Pesquisa Diagnóstico em Saúde Polonoroeste/1985, realizou-se um estudo antropométrico de peso e altura, em uma amostra de 405 crianças, menores de 6 anos de idade, em Cáceres/MT. Segundo os critérios de GOMEZ, a prevalência da desnutrição foi de 33%, 40% de desnutridos moderados e não sendo registrada a forma grave. A Classificação de WATERLOW indicou a desnutrição pregressa (36%) como a de maior prevalência, sendo os déficits de estatura mais acentuados nas faixas etárias menores de 2 anos, indicando que os programas de saúde à criança, nesta área, devam priorizar os aspectos nutricionais deste grupo etário.