978 resultados para Aortic rupture
Resumo:
This inaugural annual report for the Northern Ireland Abdominal Aortic Aneurysm (AAA) Screening Programme (produced jointly by the Public Health Agency and the Belfast Health and Social Care Trust) looks back on a successful first year for the programme. The Public Health Agency (PHA) is responsible for commissioning and quality assuring the programme. The Belfast Health and Social Care Trust is responsible for providing and managing the programme.Following significant planning, AAA screening was introduced on time in June 2012, as required by the Government's 'Priorities for Action' target. There is no doubt that this was due to sustained partnership working across a wide range of health and social care services within Northern Ireland.
Resumo:
This information leaflet is for all men invited to take part in the Northern Ireland Abdominal Aortic Aneurysm (AAA) Screening Programme. Men will automatically be invited for screening in their 65th year, while men aged over 65 can request a scan through the central screening office.
Resumo:
Objectif: Déterminer la prévalence de la dysfonction de la valve aortique, de la dilatation de l'aorte proximale et des interventions au niveau de la valve aortique et de l'aorte ascendante chez les adultes avec une coarctation de l'aorte. Contexte: La dysfonction de la valve aortique et la dilatation de l'aorte proximale sont rares chez les enfants et les adolescents avec une coarctation de l'aorte. A long terme, les adultes pourraient être plus à risque de développer ce type de pathologie. Méthode: Nous avons rétrospectivement passé en revue tous les adultes avec une coarctation de l'aorte corrigée ou pas suivis au « Boston Children's Hospital » entre 2004 et 2010. Résultats: 216 adultes (56 % d'hommes) avec une coarctation ont été identifiés. L'âge médian à la dernière évaluation était de 28 (de 18 à 75) ans. Une bicuspidie aortique était présente dans 66% des cas. Au dernier contrôle, 3% avaient une sténose aortique modérée ou sévère et 4% avaient une insuffisance aortique modérée à sévère. Une dilatation de la racine de l'aorte ou de l'aorte ascendante était présente dans 28%, respectivement 42% des patients. Une dilatation au moins modérée de la racine de l'aorte ou de l'aorte ascendante (score Z > 4) était présente dans 8%, respectivement 14%. Les patients avec une bicuspidie aortique étaient plus sujets à avoir une dilatation au moins modérée de la racine de l'aorte ou de l'aorte ascendante comparés à ceux sans bicuspidie (20% contre 0%; p<0.001). L'âge était associé à une dilatation de l'aorte ascendante (p=0.04). Au dernier suivi, 6% avait nécessité une intervention au niveau de la valve aortique et 3% un remplacement de la racine de l'aorte ou de l'aorte ascendante.
Resumo:
Transcatheter aortic valve implantation is an expanding procedure thus far restricted to a target population of old and high-comorbidity patients with symptomatic aortic stenosis. The need for bulky devices (up to 24F) combined with the high prevalence of peripheral vascular disease in these patients explains the increased risk of vascular complications in transfemoral Edwards Sapien (Edwards Lifesciences, Irvine, Calif) transcatheter aortic valve implantation procedures, with a rate of 20% for the transfemoral arm of either the Placement of AoRTic traNscathetER valves in the European Union (PARTNER EU) trial or the SOURCE Registry.1,2
Resumo:
Closed rupture of the tibialis anterior tendon is a rare injury, and it usually affects individuals older than 50 years of age. This rare injury tends to occur spontaneously, and this often delays diagnosis and adequate treatment. Although direct surgical repair of the ruptured tibialis anterior tendon is generally considered the treatment of choice, nonanatomic repair, tendon lengthening, or tendon transfer might be necessary in cases where shortening of the muscle-tendon unit has taken place. In this report, we describe 2 cases that involved the surgical repair of closed ruptures of the tibialis anterior tendon. In the first case, direct repair was undertaken at approximately 6 months after the onset of symptoms, and in the second case repair of the tibialis anterior tendon required augmentation tenodesis with the extensor retinaculum. Level of Clinical Evidence: 4.
Resumo:
In obstetrics, premature rupture of the membranes (PROM) is a frequent observation which is responsible for many premature deliveries. PROM is also associated with an increased risk of fetal and maternal infections. Early diagnosis is mandatory in order to decrease such complications. Despite that current biological tests allowing the diagnosis of PROM are both sensitive and specific, contamination of the samples by maternal blood can induce false positive results. Therefore, in order to identify new potential markers of PROM (present only in amniotic blood, and absent in maternal blood), proteomic studies were undertaken on samples collected from six women at terms (pairs of maternal plasma and amniotic fluid) as well as on four samples of amniotic fluid collected from other women at the 17(th) week of gestation. All samples (N = 16) were analyzed by two-dimensional (2-D) high-resolution electrophoresis, followed by sensitive silver staining. The gel images were studied using bioinformatic tools. Analyses were focused on regions corresponding to pI between 4.5 and 7 and to molecular masses between 20 and 50 kDa. In this area, 646 +/- 113 spots were detected, and 27 spots appeared to be present on the gels of amniotic fluid, but were absent on those of maternal plasma. Nine out of these 27 spots were also observed on the gels of the four samples of amniotic fluids collected at the 17(th) week of pregnancy. Five of these 9 spots were unambiguously detected on preparative 2-D gels stained by Coomassie blue, and were identified by mass spectrometry analyses. Three spots corresponded to fragments of plasma proteins, and 2 appeared to be fragments of proteins not known to be present in plasma. These 2 proteins were agrin (SWISS-PROT: O00468) and perlecan (SWISS-PROT: P98160). Our results show that proteomics is a valuable approach to identify new potential biological markers for future PROM diagnosis.
Resumo:
BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
Hypertension and congenital aortic valve malformations are frequent causes of ascending aortic aneurysms. The molecular mechanisms of aneurysm formation under these circumstances are not well understood. Reference genes for gene activity studies in aortic tissue that are not influenced by aortic valve morphology and its hemodynamic consequences, aortic dilatation, hypertension, or antihypertensive medication are not available so far. This study determines genes in ascending aortic tissue that are independent of these parameters. Tissue specimens from dilated and undilated ascending aortas were obtained from 60 patients (age ≤70 years) with different morphologies of the aortic valve (tricuspid undilated n = 24, dilated n = 11; bicuspid undilated n = 6, dilated n = 15; unicuspid dilated n = 4). Of the studied individuals, 36 had hypertension, and 31 received ACE inhibitors or AT1 receptor antagonists. The specimens were obtained intraoperatively from the wall of the ascending aorta. We analyzed the expression levels of 32 candidate reference genes by quantitative RT-PCR (RT-qPCR). Differential expression levels were assessed by parametric statistics. The expression analysis of these 32 genes by RT-qPCR showed that EIF2B1, ELF1, and PPIA remained constant in their expression levels in the different specimen groups, thus being insensitive to aortic valve morphology, aortic dilatation, hypertension, and medication with ACE inhibitors or AT1 receptor antagonists. Unlike many other commonly used reference genes, the genes EIF2B1, ELF1, and PPIA are neither confounded by aortic comorbidities nor by antihypertensive medication and therefore are most suitable for gene expression analysis of ascending aortic tissue.
Resumo:
OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.
Resumo:
Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien? XT stent-valve implantation through the fibrotic thin akinetic apical wall.
Resumo:
Trans-apical aortic valve replacement (AVR) is a new and rapidly growing therapy. However, there are only few training opportunities. The objective of our work is to build an appropriate artificial model of the heart that can replace the use of animals for surgical training in trans-apical AVR procedures. To reduce the necessity for fluoroscopy, we pursued the goal of building a translucent model of the heart that has nature-like dimensions. A simplified 3D model of a human heart with its aortic root was created in silico using the SolidWorks Computer-Aided Design (CAD) program. This heart model was printed using a rapid prototyping system developed by the Fab@Home project and dip-coated two times with dispersion silicone. The translucency of the heart model allows the perception of the deployment area of the valved-stent without using heavy imaging support. The final model was then placed in a human manikin for surgical training on trans-apical AVR procedure. Trans-apical AVR with all the necessary steps (puncture, wiring, catheterization, ballooning etc.) can be realized repeatedly in this setting.