938 resultados para Analysis software
Resumo:
Background: Burn sepsis is a leading cause of mortality and morbidity in patients with major burns. The use of topical antimicrobial agents has helped improve the survival of these patients. Silvazine (Sigma Pharmaceuticals, Melbourne, Australia) (1% silver sulphadiazine and 0.2% chlorhexidine digluconate) is used exclusively in Australasia, and there is no published study on its cytotoxicity. This study compared the relative cytotoxicity of Silvazine with 1% silver sulphadiazine (Flamazine (Smith & Nephew Healthcare. Hull. UK)) and a silver-based dressing (Acticoat (Smith & Nephew Healthcare, Hull, UK)). Methods: Dressings were applied to the centre of culture plates that were then seeded with keratinocytes at an estimated 25% confluence. The plates were incubated for 72 h and culture medium and dressings then removed. Toluidine blue was added to stain the remaining keratinocytes. Following removal of the dye, the plates were photographed under standard conditions and these digital images were analysed using image analysis software. Data was analysed using Student's t-test. Results: In the present study, Silvazine is the most cytotoxic agent. Seventy-two hour exposure to Silvazine in the present study results in almost no keratinocyte survival at all and a highly statistically significant reduction in cell survival relative to control, Acticoat and Flamazine (P
Resumo:
Background: This paper describes SeqDoC, a simple, web-based tool to carry out direct comparison of ABI sequence chromatograms. This allows the rapid identification of single nucleotide polymorphisms (SNPs) and point mutations without the need to install or learn more complicated analysis software. Results: SeqDoC produces a subtracted trace showing differences between a reference and test chromatogram, and is optimised to emphasise those characteristic of single base changes. It automatically aligns sequences, and produces straightforward graphical output. The use of direct comparison of the sequence chromatograms means that artefacts introduced by automatic base-calling software are avoided. Homozygous and heterozygous substitutions and insertion/deletion events are all readily identified. SeqDoC successfully highlights nucleotide changes missed by the Staden package 'tracediff' program. Conclusion: SeqDoC is ideal for small-scale SNP identification, for identification of changes in random mutagenesis screens, and for verification of PCR amplification fidelity. Differences are highlighted, not interpreted, allowing the investigator to make the ultimate decision on the nature of the change.
Resumo:
Introduction: The vasoconstricting peptide endothelin-1 (ET-1) binds two G-protein-coupled receptor subtypes, the Endothelin A (ETA) and Endothelin B (ETB) receptors. The ETB receptor subtype has been predominantly localised to the arterial and venous endothelial cells both in-vivo and in culture. Stimulation of ET-1 through this receptor subtype can modulate the expression of endothelial nitric oxide and accelerate endothelial cell wound healing. In comparison the ETA receptor is abundantly expressed in medial vascular smooth muscle cells and mediates the vasoconstrictor action of ET-1 and is thought to play a key role in angiogenesis. Aims: To determine the levels of ETA receptor expression and localisation in the internal mammary artery (IMA). Methods: Twenty-four IMA sections were examined from patients undergoing coronary artery bypass (CABG) surgery (5F; 19M; mean age 67 years). And 14 organ donor IMA specimens were used as controls (7M; 7F; mean age 45 years. The tissue was fixed in formalin and processed for histology. Immunohistochemistry was performed on cross-sections of the left distal IMA to assess the areas of ETA receptor staining. The percentage are of ETA receptor staining in the media was calculated using image analysis software connected to an optical microscope and semiquantitative assessment was used to grade staining intensity, that is, mild (+), moderate (++) and strong (+++). Results: ETA receptor staining was significantly elevated in the media of the CABG specimens compared with the donor controls (46.88+/11.52% Vs 18.58+/7.65%, P = .0001). Interestingly, the endothelium (++) of the IMA, as well as the small microvessels in the adventitia (+++) stained positive for ETA receptor expression. Without using a haematoxylin counterstain, the nuclei of the cell stained more intensely (+++) with respect to the cytoplasm in both the medial smooth muscle (++) and endothelial cells (++). Fibroblasts in the medial adventitia junction were also positive for ETA receptor expression (+++). Further, this receptor subtype was also strongly expressed by inflammatory cells (monocytes and macrophages). Conclusions: These results demonstrate that the ETA receptor expression is increased in the medial SMC layer of the CABG IMA specimens and also present in the endothelium, vasa vasorum, fibroblasts and inflammatory cell types. Thus it is possible that in addition to affecting vascular tone, ET-1 may play an important role in IMA remodelling.
Resumo:
Microbial transglutaminase (mTGase) is an enzyme that introduces a covalent bond between peptide bound glutamine and lysine residues. Proteins cross-linked in this manner are often more resistant to proteolytic degradation and show increased tensile strength. This study evaluates the effects of mTGase mediated cross-linking of collagen on the cellular morphology, behaviour and viability of murine 3T3 fibroblasts following their seeding into collagen scaffolds. Additionally, cell mediated scaffold contraction, porosity and level of cross-linking of the scaffold has been analysed using image analysis software, scanning electron microscopy (SEM), colorimetric assays, and Fourier transform infrared spectroscopy (FTIR). We demonstrate that the biocompatibility and cellular morphology, when comparing cultures of fibroblasts integrated in mTGase cross-linked collagen scaffolds with the native collagen counterparts, remained unaffected. It has been also elicited that the structural characteristics of collagen have been preserved while introducing enzymatically resistant covalent bonds.
Resumo:
This doctoral research project examines the effects that geographical transience has on Royal Air Force families. The methodology employed in this exploratory and qualitative study consisted largely of open-ended interview questions but also included a series of demographic variables. In total, 29 RAF personnel without families, 33 RAF personnel with families, 33 RAF spouses, and 15 RAF children participated in this research (N = 110). All respondents volunteered to take part in the study and were based in the United Kingdom at the time of data collection. The interviews were transcribed and content coded according to six major relocation themes arising from the literature (change, tasks, support, coping, difficulty, and outcome). QSR NVIVO 2.0, a qualitative data analysis software package, was used to facilitate the process. Through the utilisations of qualitative methodology, the researcher was able to offer various novel and reoccurring variables that appear to play an important role (at least subjectively) in relocation. Additionally, frequencies associated with these factors were presented. The findings were integrated with those from the literature in order to offer an initial comparison and differentiation between civilian and military samples. The main theoretical contributions were the introduction of the concept of mobile mentality, the creation of a novel relocation model that takes familial interaction into account, and the development of a taxonomy for the classification of relocation outcomes. Finally, additional observations, recommendations for future research, and practical implications are reviewed.
Resumo:
The ability to measure ocular surface temperature (OST) with thermal imaging offers potential insight into ocular physiology that has been acknowledged in the literature. The TH7102MX thermo-camera (NEC San-ei, Japan) continuously records dynamic information about OST without sacrificing spatial resolution. Using purpose-designed image analysis software, it was possible to select and quantify the principal components of absolute temperature values and the magnitude plus rate of temperature change that followed blinking. The techniques was examined for repeatability, reproducibility and the effects of extrinsic factors: a suitable experimental protocol was thus developed. The precise source of the measured thermal radiation has previously been subject toe dispute: in this thesis, the results of a study examining the relationships between physical parameters of the anterior eye and OST, confirmed a principal role for the tear film in OST. The dynamic changes in OST were studied in a large group of young subjects: quantifying the post-blink changes in temperature with time also established a role for tear flow dynamics in OST. Using dynamic thermography, the effects of hydrogel contact lens wear on OST were investigated: a model eye for in vivo work, and both neophyte and adapted contact lens wearers for in vivo studies. Significantly greater OST was observed in contact lens wearers, particularly with silicone hydrogel lenses compared to etafilcon A, and tended to be greatest when lenses had been worn continuously. This finding is important to understanding the ocular response to contact lens wear. In a group of normal subjects, dynamic thermography appeared to measure the ocular response to the application of artificial tear drops: this may prove to be a significant research and clinical tool.
Resumo:
This thesis describes an investigation into methods for controlling the mode distribution in multimode optical fibres. The major contributions presented in this thesis are summarised below. Emerging standards for Gigabit Ethernet transmission over multimode optical fibre have led to a resurgence of interest in the precise control, and specification, of modal launch conditions. In particular, commercial LED and OTDR test equipment does not, in general, comply with these standards. There is therefore a need for mode control devices, which can ensure compliance with the standards. A novel device consisting of a point-load mode-scrambler in tandem with a mode-filter is described in this thesis. The device, which has been patented, may be tuned to achieve a wide range of mode distributions and has been implemented in a ruggedised package for field use. Various other techniques for mode control have been described in this work, including the use of Long Period Gratings and air-gap mode-filters. Some of the methods have been applied to other applications, such as speckle suppression and in sensor technology. A novel, self-referencing, sensor comprising two modal groups in the Mode Power Distribution has been designed and tested. The feasibility of a two-channel Mode Group Diversity Multiplexed system has been demonstrated over 985m. A test apparatus for measuring mode distribution has been designed and constructed. The apparatus consists of a purpose-built video microscope, and comprehensive control and analysis software written in Visual Basic. The system may be fitted with a Silicon camera or an InGaAs camera, for measurement in the 850nm and 130nm transmission windows respectively. A limitation of the measurement method, when applied to well-filled fibres, has been identified and an improvement to the method has been proposed, based on modelled Laguerre Gauss field solutions.
Resumo:
Nanoindentation has become a common technique for measuring the hardness and elastic-plastic properties of materials, including coatings and thin films. In recent years, different nanoindenter instruments have been commercialised and used for this purpose. Each instrument is equipped with its own analysis software for the derivation of the hardness and reduced Young's modulus from the raw data. These data are mostly analysed through the Oliver and Pharr method. In all cases, the calibration of compliance and area function is mandatory. The present work illustrates and describes a calibration procedure and an approach to raw data analysis carried out for six different nanoindentation instruments through several round-robin experiments. Three different indenters were used, Berkovich, cube corner, spherical, and three standardised reference samples were chosen, hard fused quartz, soft polycarbonate, and sapphire. It was clearly shown that the use of these common procedures consistently limited the hardness and reduced the Young's modulus data spread compared to the same measurements performed using instrument-specific procedures. The following recommendations for nanoindentation calibration must be followed: (a) use only sharp indenters, (b) set an upper cut-off value for the penetration depth below which measurements must be considered unreliable, (c) perform nanoindentation measurements with limited thermal drift, (d) ensure that the load-displacement curves are as smooth as possible, (e) perform stiffness measurements specific to each instrument/indenter couple, (f) use Fq and Sa as calibration reference samples for stiffness and area function determination, (g) use a function, rather than a single value, for the stiffness and (h) adopt a unique protocol and software for raw data analysis in order to limit the data spread related to the instruments (i.e. the level of drift or noise, defects of a given probe) and to make the H and E r data intercomparable. © 2011 Elsevier Ltd.
Resumo:
2000 Mathematics Subject Classification: 62H30
Resumo:
In 2010, the American Association of State Highway and Transportation Officials (AASHTO) released a safety analysis software system known as SafetyAnalyst. SafetyAnalyst implements the empirical Bayes (EB) method, which requires the use of Safety Performance Functions (SPFs). The system is equipped with a set of national default SPFs, and the software calibrates the default SPFs to represent the agency's safety performance. However, it is recommended that agencies generate agency-specific SPFs whenever possible. Many investigators support the view that the agency-specific SPFs represent the agency data better than the national default SPFs calibrated to agency data. Furthermore, it is believed that the crash trends in Florida are different from the states whose data were used to develop the national default SPFs. In this dissertation, Florida-specific SPFs were developed using the 2008 Roadway Characteristics Inventory (RCI) data and crash and traffic data from 2007-2010 for both total and fatal and injury (FI) crashes. The data were randomly divided into two sets, one for calibration (70% of the data) and another for validation (30% of the data). The negative binomial (NB) model was used to develop the Florida-specific SPFs for each of the subtypes of roadway segments, intersections and ramps, using the calibration data. Statistical goodness-of-fit tests were performed on the calibrated models, which were then validated using the validation data set. The results were compared in order to assess the transferability of the Florida-specific SPF models. The default SafetyAnalyst SPFs were calibrated to Florida data by adjusting the national default SPFs with local calibration factors. The performance of the Florida-specific SPFs and SafetyAnalyst default SPFs calibrated to Florida data were then compared using a number of methods, including visual plots and statistical goodness-of-fit tests. The plots of SPFs against the observed crash data were used to compare the prediction performance of the two models. Three goodness-of-fit tests, represented by the mean absolute deviance (MAD), the mean square prediction error (MSPE), and Freeman-Tukey R2 (R2FT), were also used for comparison in order to identify the better-fitting model. The results showed that Florida-specific SPFs yielded better prediction performance than the national default SPFs calibrated to Florida data. The performance of Florida-specific SPFs was further compared with that of the full SPFs, which include both traffic and geometric variables, in two major applications of SPFs, i.e., crash prediction and identification of high crash locations. The results showed that both SPF models yielded very similar performance in both applications. These empirical results support the use of the flow-only SPF models adopted in SafetyAnalyst, which require much less effort to develop compared to full SPFs.
Resumo:
During the past three decades, the use of roundabouts has increased throughout the world due to their greater benefits in comparison with intersections controlled by traditional means. Roundabouts are often chosen because they are widely associated with low accident rates, lower construction and operating costs, and reasonable capacities and delay. ^ In the planning and design of roundabouts, special attention should be given to the movement of pedestrians and bicycles. As a result, there are several guidelines for the design of pedestrian and bicycle treatments at roundabouts that increase the safety of both pedestrians and bicyclists at existing and proposed roundabout locations. Different design guidelines have differing criteria for handling pedestrians and bicyclists at roundabout locations. Although all of the investigated guidelines provide better safety (depending on the traffic conditions at a specific location), their effects on the performance of the roundabout have not been examined yet. ^ Existing roundabout analysis software packages provide estimates of capacity and performance characteristics. This includes characteristics such as delay, queue lengths, stop rates, effects of heavy vehicles, crash frequencies, and geometric delays, as well as fuel consumption, pollutant emissions and operating costs for roundabouts. None of these software packages, however, are capable of determining the effects of various pedestrian crossing locations, nor the effect of different bicycle treatments on the performance of roundabouts. ^ The objective of this research is to develop simulation models capable of determining the effect of various pedestrian and bicycle treatments at single-lane roundabouts. To achieve this, four models were developed. The first model simulates a single-lane roundabout without bicycle and pedestrian traffic. The second model simulates a single-lane roundabout with a pedestrian crossing and mixed flow bicyclists. The third model simulates a single-lane roundabout with a combined pedestrian and bicycle crossing, while the fourth model simulates a single-lane roundabout with a pedestrian crossing and a bicycle lane at the outer perimeter of the roundabout for the bicycles. Traffic data was collected at a modern roundabout in Boca Raton, Florida. ^ The results of this effort show that installing a pedestrian crossing on the roundabout approach will have a negative impact on the entry flow, while the downstream approach will benefit from the newly created gaps by pedestrians. Also, it was concluded that a bicycle lane configuration is more beneficial for all users of the roundabout instead of the mixed flow or combined crossing. Installing the pedestrian crossing at one-car length is more beneficial for pedestrians than two- and three-car lengths. Finally, it was concluded that the effect of the pedestrian crossing on the vehicle queues diminishes as the distance between the crossing and the roundabout increases. ^
Resumo:
This study examined the motivation of college and university faculty to implement service-learning into their traditional courses. The benefits derived by faculty, as well as those issues of maintenance, including supports and/or obstacles, were also investigated in relation to their impact on motivation. The focus was on generating theory from the emerging data. ^ Data were collected from interviews with 17 faculty teaching courses that included a component of service-learning. A maximum variation sampling of participants from six South Florida colleges and universities was utilized. Faculty participants represented a wide range of academic disciplines, faculty ranks, years of experience in teaching and using service-learning as well as gender and ethnic diversity. For data triangulation, a focus group with eight additional college faculty was conducted and documents, including course syllabi and institutional service-learning handbooks, collected during the interviews were examined. The interviews were transcribed and coded using traditional methods as well as with the assistance of the computerized assisted qualitative data analysis software, Atlas.ti. The data were organized into five major categories with themes and sub-themes emerging for each. ^ While intrinsic or personal factors along with extrinsic factors all serve to influence faculty motivation, the study's findings revealed that the primary factors influencing faculty motivation to adopt service-learning were those that were intrinsic or personal in nature. These factors included: (a) past experiences, (b) personal characteristics including the value of serving, (c) involvement with community service, (d) interactions and relationships with peers, (e) benefits to students, (f) benefits to teaching, and (g) perceived career benefits. Implications and recommendations from the study encompass suggestions for administrators in higher education institutions for supporting and encouraging faculty adoption of service-learning including a well developed infrastructure as well as incentives, particularly during the initial implementation period, rewards providing recognition for the academic nature of service-learning and support for the development of peer relationships among service-learning faculty. ^
Resumo:
The aim of this work is to present a methodology to develop cost-effective thermal management solutions for microelectronic devices, capable of removing maximum amount of heat and delivering maximally uniform temperature distributions. The topological and geometrical characteristics of multiple-story three-dimensional branching networks of microchannels were developed using multi-objective optimization. A conjugate heat transfer analysis software package and an automatic 3D microchannel network generator were developed and coupled with a modified version of a particle-swarm optimization algorithm with a goal of creating a design tool for 3D networks of optimized coolant flow passages. Numerical algorithms in the conjugate heat transfer solution package include a quasi-ID thermo-fluid solver and a steady heat diffusion solver, which were validated against results from high-fidelity Navier-Stokes equations solver and analytical solutions for basic fluid dynamics test cases. Pareto-optimal solutions demonstrate that thermal loads of up to 500 W/cm2 can be managed with 3D microchannel networks, with pumping power requirements up to 50% lower with respect to currently used high-performance cooling technologies.
Resumo:
The programs of conditional cash transfer are widespread in developing countries in Latin America with emphasis on Brazil as a new paradigm in social p olicies for poverty eradication . Consist of transferring monetary funds from the government directly to poor families by fulfilling the condition alities on education and health . In health, even wi th variations between countries , conditionality targeting public pregnant women and children with a view to improving health indic ators maternoinfantil as growth , infant mortality and prenatal care. The objectives of this study are to compare the transfer progr am conditional Brazilian income , the Family and similar programs in Latin A merica in relation to it s effects on growth in children , and to evaluate the effect of Bolsa Família in the prevalence of use of services ( conditionalities ) of prenatal care in Brazilian health services whose teams joined the Programa de Acesso e Melhoria da Qualidade da Atenção Básica (PMAQ - AB) . For the first objective a systematic review , we selec ted ten articles between 1007 ( one thousand and seven ) found in the databases Embase , PubMed, Scopus , Scielo and Lilacs databases was performed . Articles are ob servational epidemiological studies of transverse descriptive and analytical types of cohort and case - co ntrol. For the second objective, for it is a prevalence study , a statistical analysis using Poisson regression with robust variance was performed to i nvestigate how the prevalence of compliance with conditionalities on health was influenced b y various explanatory variables . Ratios , crude and adjusted prevalence , with their respective confidence i ntervals of 95 % were estimated . The family joined the sch olarship program was considered as the main expo sure variable . Confounding variables were: maternal age , race / color, paid employment , marital status and region of residence . In d ata analysis software R 3.0.1 (RDevelopment Core Team 2013 ) was used . Rega rding the comparison of the Bolsa Família with other programs in Latin America , the review found similar results regarding the positive effect of income transfer in the nutritional status o f beneficiary children programs , and these effects are more evident in children under two years old and belonging to familie s of lower socioeconomic status . For the prevalence of conditionalities entres different groups of users of the Bolsa Família and nonusers results showed no statistically significant difference betwe en respondents (with children under two years ) registered and not registered in PBF on issues relating to: me et at least six prenatal visits , meet and participate in health education activities . It follows from side to increase minimum income for families in extreme poverty showed positive impact on children's health in Brazil and Latin America. The o ther is not confirmed in Brazil , an increase in conditionality expressed in use of primary care by the user s of the Bolsa Família services.
Resumo:
The work described in this thesis was conducted with the aim of: 1) investigating the binding capabilities of calix[4]arene-functionalized microcantilevers towards specific metal ions and 2) developing a new16-microcantilever array sensing system for the rapid, and simultaneous detection of metal ions in fresh water. Part I of this thesis reports on the use of three new bimodal calix[4]arenes (methoxy, ethoxy and crown) as potential host/guest sensing layers for detecting selected ions in dilute aqueous solutions using single microcantilever experimental system. In this work it was shown that modifying the upper rim of the calix[4]arenes with a thioacetate end group allow calix[4]arenes to self-assemble on Au(111) forming complete highly ordered monolayers. It was also found that incubating the microcantilevers coated with 5 nm of Inconel and 40 nm of Au for 1 h in a 1.0 M solution of calix[4]arene produced the highest sensitivity. Methoxy-functionalized microcantilevers showed a definite preference for Ca²⁺ ions over other cationic guests and were able to detect trace concentration as low as 10⁻¹² M in aqueous solutions. Microcantilevers modified with ethoxy calix[4]arene displayed their highest sensitivity towards Sr²⁺ and to a lesser extent Ca²⁺ ions. Crown calix[4]arene-modified microcantilevers were however found to bind selectively towards Cs⁺ ions. In addition, the counter anion was also found to contribute to the deflection. For example methoxy calix[4]arene-modified microcantilever was found to be more sensitive to CaCl₂ over other water-soluble calcium salts such as Ca(NO₃)₂ , CaBr₂ and CaI₂. These findings suggest that the response of calix[4]arene-modified microcantilevers should be attributed to the target ionic species as a whole instead of only considering the specific cation and/or anion. Part II presents the development of a 16-microcantilever sensor setup. The implementation of this system involved the creation of data analysis software that incorporates data from the motorized actuator and a two-axis photosensitive detector to obtain the deflection signal originating from each individual microcantilever in the array. The system was shown to be capable of simultaneous measurements of multiple microcantilevers with different coatings. A functionalization unit was also developed that allows four microcantilevers in the array to be coated with an individual sensing layer one at the time. Because of the variability of the spring constants of different cantilevers within the array, results presented were quoted in units of surface stress unit in order to compare values between the microcantilevers in the array.