984 resultados para Analysis of electromyographic signal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of adsorptive stripping potentiometry to the reductive detection of nucleic acids at mercury electrodes is reported. Compared to analogous voltammetric stripping modes, constant current potentiometric stripping analysis (PSA) effectively addresses the hydrogen discharge background problem, and hence greatly improves the characteristics of the superimposed cytosine/adenine (CA) reduction peak. Compared to earlier schemes for trace measurements of nucleic acids at mercury or carbon electrodes that rely on anodic signals arising from the guanine residue, convenient quantitation can now be carried out in connection with the cytosine and adenine residues. Variables influencing the adsorptive PSA response are explored and optimized. With five minute accumulation, the detection limits for tRNA, ssDNA and dsDNA are 30 mu g l(-1), 60 mu g l(-1) and 2 mg l(-1), respectively. Such different values reflect the strong dependence of the PSA CA signal upon the nucleic-acid structure. This allows the quantitation of ssDNA or tRNA in the presence of dsDNA, and offers new possibilities for electrochemical studies of DNA structure and interactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper provides an insight to the trade-off between settling time and power consumption in regulated current mirrors as building parts in micropower current-switching D/A converters. The regulation-loop frequency characteristic is obtained and difficulties to impose a dominant-pole condition to the resulting 2nd-order system are evaluated. Raising pole frequencies in micropower circuits, while meeting consumption requirements, is basically limited by parasitic capacitances. For such cases, an alternative is to impose a twin-pole condition in which design constraints are somewhat relieved and settling slightly improved. Relationships between pole frequencies, transistor geometry and bias are established and design guidelines for regulated current mirrors founded. By placing loop-transistors in either weak or strong inversion, small (W/L) ratios are allowed and stray capacitances reduced. Simulated waveforms suggest a good agreement with theory. The proposed approach applied to the design of a micropower current-mode D/A converter improves both simulated and experimental settling performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A computer-assisted method for analysing photoacoustic spectra has been developed in the Windows(TM) environment with the use of an easy graphical interface, the computer simulation was carried out with the aim of using the entire expression of the Rosencwaig-Gersho theory, thus permitting multiple applications. The simulation was applied to a system that mimics the electron transfer process in which the concentration of octaethylporphin donor molecules was constant whereas the concentration of duroquinone and 2,3-dichloro-5,6-dicyano-1, l-benzoquinone acceptor molecules varied. The increment of the acceptor concentration influenced the photoacoustic amplitude and phase signals. In the phase signal a significant shift to smaller values was observed, denoting a faster heat generation. The analysis of the photoacoustic signal enabled the determination of the thermal diffusivity, the result obtained through the simulation was about (7 +/- 1) x 10(-7) m(2) s(-1) indicating that changes in the photoacoustic phase signals were due to the electron transfer process rather than changes in the thermal properties of the sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Turnera diffusa Willd. var. afrodisiaca (Ward) Urb. (syn. T. aphrodisiaca) belongs to the family of Turneraceae and is an aromatic plant growing wild in the subtropical regions of America and Africa. It is widely used in the traditional medicine as e.g. anti-cough, diuretic, and aphrodisiac agent. This work presents a 3 min chromatographic analysis using low-pressure (LP) gas chromatography (GC)-ion-trap (IT) mass spectrometry (MS). The combination of a deactivated 0.6 m x 0.10 mm i.d., restrictor with a wide-bore CP-Wax 52 capillary column (10 m x 0.53 mm i.d., 1 mum) reduces the analysis time by a factor of 3-7 in comparison to the use of a conventional narrow bore column. Chromatographic conditions have been optimized to achieve the fastest separation with the highest signal/noise ratio in MS detection. These results allow fast and reliable quality control of the essential oil to be achieved. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a thermoeconomic analysis method based on the First and the Second Law of Thermodynamics and applied to analyse the replacement of an equipment of a cogeneration system is presented. The cogeneration system consists of a gas turbine linked to a waste boiler. The electrical demand of the campus is approximately 9 MW but the cogen system generates approximately one third of the university requirement as well as 1.764 kg/s of saturated steam (at 0.861 MPa), approximately, from a single fuel source. The energy-economic study showed that the best system, based on pay-back period and based on the maximum savings (in 10 years), was the system that used the gas turbine M1T-06 of Kawasaki Heavy Industries and the system that used the gas turbine CCS7 of Hitachi Zosen, respectively. The exergy-economic study showed that the best system, which has the lowest EMC, was the system that used the gas turbine ASE50 of Allied Signal. © 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To carry out a retrospective study to determine whether human papillomavirus (HPV) infection and immunohistochemical expression of p53 and proliferating cell nuclear antigen (PCNA) are related to the risk of oral cancer. STUDY DESIGN: Fifty-seven oral biopsies, consisting of 30 oral squamous papillomas (OSPs) and 27 oral squamous cell carcinomas (OSCCs) were tested for the presence of HPV 6/11 and 16/18 by in situ hybridization using catalyzed signal amplification and in situ hybridization. p53 And PCNA expression was analyzed by immunohistochemistry and evaluated quantitatively by image analysis. RESULTS: Nineteen of the 57 oral lesions (33.3%) were positive for HPV. HPV 6/11 was found in 6 of 30 (20%) OSPs and 1 of 27 (3.7%) OSCCs. HPV 16/18 was found in 10 of 27 (37%) OSCCs and 2 of 30 (6.7%) OSPs. Sixteen of the 19 HPV-positive cases (84.2%) were p53 negative; 5 (9%) were HPV 6/11 and 11 (19%) HPV 16/18, with an inverse correlation between the presence of HPV DNA and p53 expression (P=.017, P < .05). PCNA expression appeared in 18 (94.7%) of HPV positive cases, showing that HPV 16/18 was associated with intensity of PCNA expression and with OSCCs (P=.037, P < .05). CONCLUSION: Quantitative evaluation of p53 by image analysis showed an inverse correlation between p53 expression and HPV presence, suggesting protein degradation. Image analysis also demonstrated that PCNA expression was more intense in HPV DNA 16/18 OSCCs. These findings suggest involvement of high-risk HPV types in oral carcinogenesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Piezoelectric actuators are widely used in positioning systems which demand high resolution such as scanning microscopy, fast mirror scanners, vibration cancellation, cell manipulation, etc. In this work a piezoelectric flextensional actuator (PFA), designed with the topology optimization method, is experimentally characterized by the measurement of its nanometric displacements using a Michelson interferometer. Because this detection process is non-linear, adequate techniques must be applied to obtain a linear relationship between an output electrical signal and the induced optical phase shift. Ideally, the bias phase shift in the interferometer should remain constant, but in practice it suffers from fading. The J1-J4 spectral analysis method provides a linear and direct measurement of dynamic phase shift in a no-feedback and no-phase bias optical homodyne interferometer. PFA application such as micromanipulation in biotechnology demands fast and precise movements. So, in order to operate with arbitrary control signals the PFA must have frequency bandwidth of several kHz. However as the natural frequencies of the PFA are low, unwanted dynamics of the structure are often a problem, especially for scanning motion, but also if trajectories have to be followed with high velocities, because of the tracking error phenomenon. So the PFA must be designed in such a manner that the first mechanical resonance occurs far beyond this band. Thus it is important to know all the PFA resonance frequencies. In this work the linearity and frequency response of the PFA are evaluated up to 50 kHz using optical interferometry and the J1-J4 method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a tool box developed to read files describing a SIMULINK® model and translates it into a structural VHDL-AMS description. In translation process, all files and directory structures to simulate the translated model on SystemVision™ environment is generate. The tool box named MS2SV was tested by three models of commercially available digital-to-analogue converters. All models use the R2R ladder network to conversion, but the functionality of these three components is different. The methodology of conversion of the model is presents together with sort theory about R-2R ladder network. In the evaluation of the translated models, we used a sine waveform input signal and the waveform generated by D/A conversion process was compared by FFT analysis. The results show the viability of this type of approach. This work considers some of challenges set by the electronic industry for the further development of simulation methodologies and tools in the field of mixed-signal technology. © 2007 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ResumoThe main idea of this work is based on the analysis of the electric torque through the acting of the PS in the power system, provided of a control for the compensation degree (PSC). A linear model of the single machine-infinite bus system is used with a PS installed (SMIB/PS system). The variable that represents the presence of PS in the net is associated to the phase displacement introduced in the terminal voltage of the synchronous machine by PS. For the input signals of the PSC are evaluated variations of the angular speed of the rotor, the current magnitude and the active power through the line where the PS is located. The simulations are accomplished to analyze the influence of the PS in the torque formation (synchronizing and damping), of the SMIB/PS system. The analysis are developed in the time and frequency domain.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers the importance of using a top-down methodology and suitable CAD tools in the development of electronic circuits. The paper presents an evaluation of the methodology used in a computational tool created to support the synthesis of digital to analog converter models by translating between different tools used in a wide variety of applications. This tool is named MS 2SV and works directly with the following two commercial tools: MATLAB/Simulink and SystemVision. Model translation of an electronic circuit is achieved by translating a mixed-signal block diagram developed in Simulink into a lower level of abstraction in VHDL-AMS and the simulation project support structure in SystemVision. The method validation was performed by analyzing the power spectral of the signal obtained by the discrete Fourier transform of a digital to analog converter simulation model. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a simple, environmentally friendly and rapid quantitative spot test procedure for the determination of captopril (CPT) in bulk drug and in pharmaceutical formulations by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound (λ max 490 nm) produced by the spot test reaction between CPT and p-chloranil (CL). Under optimal conditions, calibration curves were obtained for CPT by plotting the optical density of the reflectance signal (A R) vs. the log of the mol L -1 concentration, from 6.91×10 -3 to 1.17×10 -1, with a good coefficient of determination (R 2 = 0.9992). The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine CPT in commercial pharmaceutical formulations. The results obtained by the proposed method are compared favorably with those obtained by an official procedure at 95% confidence level. The method validation results showed that the sensitivity and selectivity of the methods were adequated for drug monitoring in industrial quality control laboratories. © 2011 Moment Publication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)