924 resultados para Aeronautical instruments
Resumo:
In order to make best use of the opportunities provided by space missions such as the Radiation Belt Storm Probes, we determine the response of complementary subionospheric radiowave propagation measurements (VLF), riometer absorption measurements (CNA), and GPS-produced total electron content (vTEC) to different energetic electron precipitation (EEP). We model the relative sensitivity and responses of these instruments to idealised monoenergetic beams of precipitating electrons, and more realistic EEP spectra chosen to represent radiation belts and substorm precipitation. In the monoenergetic beam case, we find riometers are more sensitive to the same EEP event occurring during the day than during the night, while subionospheric VLF shows the opposite relationship, and the change in vTEC is independent. In general, the subionospheric VLF measurements are much more sensitive than the other two techniques for EEP over 200 keV, responding to flux magnitudes two-three orders of magnitude smaller than detectable by a riometer. Detectable TEC changes only occur for extreme monoenergetic fluxes. For the radiation belt EEP case, clearly detectable subionospheric VLF responses are produced by daytime fluxes that are ~10 times lower than required for riometers, while nighttime fluxes can be 10,000 times lower. Riometers are likely to respond only to radiation belt fluxes during the largest EEP events and vTEC is unlikely to be significantly disturbed by radiation belt EEP. For the substorm EEP case both the riometer absorption and the subionospheric VLF technique respond significantly, as does the change in vTEC, which is likely to be detectable at ~3-4 TECu.
Resumo:
Two aircraft instruments for the measurement of total odd nitrogen (NOy) were compared side by side aboard a Learjet A35 in April 2003 during a campaign of the AFO2000 project SPURT (Spurengastransport in der Tropopausenregion). The instruments albeit employing the same measurement principle (gold converter and chemiluminescence) had different inlet configurations. The ECO-Physics instrument operated by ETH-Zürich in SPURT had the gold converter mounted outside the aircraft, whereas the instrument operated by FZ-Jülich in the European project MOZAIC III (Measurements of ozone, water vapour, carbon monoxide and nitrogen oxides aboard Airbus A340 in-service aircraft) employed a Rosemount probe with 80 cm of FEP-tubing connecting the inlet to the gold converter. The NOy concentrations during the flight ranged between 0.3 and 3 ppb. The two data sets were compared in a blind fashion and each team followed its normal operating procedures. On average, the measurements agreed within 7%, i.e. within the combined uncertainty of the two instruments. This puts an upper limit on potential losses of HNO3 in the Rosemount inlet of the MOZAIC instrument. Larger transient deviations were observed during periods after calibrations and when the aircraft entered the stratosphere. The time lag of the MOZAIC instrument observed in these instances is in accordance with the time constant of the MOZAIC inlet line determined in the laboratory for HNO3.
Resumo:
Combining SNPs into allele scores provides a more powerful instrument for MR analysis than a single SNP in isolation. Population stratification and the potential for pleiotropic effects need to be considered in MR studies on vitamin D.
Resumo:
We present the first comprehensive intercomparison of currently available satellite ozone climatologies in the upper troposphere/lower stratosphere (UTLS) (300–70 hPa) as part of the Stratosphere-troposphere Processes and their Role in Climate (SPARC) Data Initiative. The Tropospheric Emission Spectrometer (TES) instrument is the only nadir-viewing instrument in this initiative, as well as the only instrument with a focus on tropospheric composition. We apply the TES observational operator to ozone climatologies from the more highly vertically resolved limb-viewing instruments. This minimizes the impact of differences in vertical resolution among the instruments and allows identification of systematic differences in the large-scale structure and variability of UTLS ozone. We find that the climatologies from most of the limb-viewing instruments show positive differences (ranging from 5 to 75%) with respect to TES in the tropical UTLS, and comparison to a “zonal mean” ozonesonde climatology indicates that these differences likely represent a positive bias for p ≤ 100 hPa. In the extratropics, there is good agreement among the climatologies regarding the timing and magnitude of the ozone seasonal cycle (differences in the peak-to-peak amplitude of <15%) when the TES observational operator is applied, as well as very consistent midlatitude interannual variability. The discrepancies in ozone temporal variability are larger in the tropics, with differences between the data sets of up to 55% in the seasonal cycle amplitude. However, the differences among the climatologies are everywhere much smaller than the range produced by current chemistry-climate models, indicating that the multiple-instrument ensemble is useful for quantitatively evaluating these models.
Resumo:
Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.
Resumo:
We establish a methodology for calculating uncertainties in sea surface temperature estimates from coefficient based satellite retrievals. The uncertainty estimates are derived independently of in-situ data. This enables validation of both the retrieved SSTs and their uncertainty estimate using in-situ data records. The total uncertainty budget is comprised of a number of components, arising from uncorrelated (eg. noise), locally systematic (eg. atmospheric), large scale systematic and sampling effects (for gridded products). The importance of distinguishing these components arises in propagating uncertainty across spatio-temporal scales. We apply the method to SST data retrieved from the Advanced Along Track Scanning Radiometer (AATSR) and validate the results for two different SST retrieval algorithms, both at a per pixel level and for gridded data. We find good agreement between our estimated uncertainties and validation data. This approach to calculating uncertainties in SST retrievals has a wider application to data from other instruments and retrieval of other geophysical variables.
Resumo:
A pilot study consisting of a parent questionnaire, four APD tests and an acceptability questionnaire were presented to normal hearing and cognitively developing children between the ages of 8-12 years. Responses to a standard and modified response format of the APD tests were obtained over two test sessions. Results indicated that the modified response formats of the four APD tests were acceptable, fairly reliable and three out of the four APD tests were valid.
Resumo:
Objective: The aim of this study was to verify the discriminative power of the most widely used pain assessment instruments. Methods: The sample consisted of 279 subjects divided into Fibromyalgia Group (FM- 205 patients with fibromyalgia) and Control Group (CG-74 healthy subjects), mean age 49.29 +/- 10.76 years. Only 9 subjects were male, 6 in FM and 3 in CG. FM were outpatients from the Rheumatology Clinic of the University of Sao Paulo - Hospital das Clinicas (HCFMUSP); the CG included people accompanying patients and hospital staff with similar socio-demographic characteristics. Three instruments were used to assess pain: the McGill Pain Questionnaire (MPQ), the Visual Analog Scale (VAS), and the Dolorimetry, to measure pain threshold on tender points (generating the TP index). In order to assess the discriminative power of the instruments, the measurements obtained were submitted to descriptive analysis and inferential analysis using ROC Curve - sensibility (S), specificity (S I) and area under the curve (AUC) - and Contingence tables with Chi-square Test and odds ratio. Significance level was 0.05. Results: Higher sensibility, specificity and area under the curve was obtained by VAS (80%, 80% and 0.864, respectively), followed by Dolorimetry (S 77%, S177% and AUC 0.851), McGill Sensory (S 72%, S167% and AUC 0.765) and McGill Affective (S 69%, S1 67% and AUC 0.753). Conclusions: VAS presented the higher sensibility, specificity and AUC, showing the greatest discriminative power among the instruments. However, these values are considerably similar to those of Dolorimetry.
Resumo:
The Center for the Study of Free-Reed Instruments Collection is an archival collection at the City University of New York Graduate Center’s Mina Rees Library which contains materials donated by Professor Allan W. Atlas, related to free-reed instruments and the International Concertina Association.
Resumo:
The newly adopted energy efficiency directive (2012/27/EU) highlights the importance of energy efficiency in reaching the Union’s 2020 targets. The directive commits member states to defining national energy efficiency targets (art. 3), achieving yearly energy savings of 1.5% of the annual energy sales through the energy efficiency obligation scheme (art. 7), and providing a long-term strategy for the building sector that aims at a 3% refurbishment rate for public buildings (art. 4+5). Buildings currently account for 40% of energy use in most countries, putting them among the largest end-use sectors. This report takes a closer look at the best practices for implementing increasing energy efficiency in different regions and countries in Europe. The final aim is to identify some policy tools to be suggested to the region of Dalarna (Dalarna having been chosen as the pilot county in Sweden) as a means of implementing energy efficiency in the building sector. The final objective is to give analysts and decision-makers a better analytical foundation to explore future policy development in the area of buildings to be proposed and tested at the regional level in Dalarna and later at the national level in Sweden.
Resumo:
This dissertation deals with the problem of making inference when there is weak identification in models of instrumental variables regression. More specifically we are interested in one-sided hypothesis testing for the coefficient of the endogenous variable when the instruments are weak. The focus is on the conditional tests based on likelihood ratio, score and Wald statistics. Theoretical and numerical work shows that the conditional t-test based on the two-stage least square (2SLS) estimator performs well even when instruments are weakly correlated with the endogenous variable. The conditional approach correct uniformly its size and when the population F-statistic is as small as two, its power is near the power envelopes for similar and non-similar tests. This finding is surprising considering the bad performance of the two-sided conditional t-tests found in Andrews, Moreira and Stock (2007). Given this counter intuitive result, we propose novel two-sided t-tests which are approximately unbiased and can perform as well as the conditional likelihood ratio (CLR) test of Moreira (2003).
The distortion of currencies misalignments on trade Instruments: or why currencies wars are not over
Resumo:
The negotiations of mega agreements between the US and the Pacific countries (TPP) and between the US and the EU (TTIP) are raising the attention of experts on international trade law and economics. TPP and TTIP are proclaimed to be the designers of the rules for the XXI Century. Old trade instruments such as tariffs are said to be no more important for TTIP because tariffs are negligible among those partners but significant to for TPP. Another relevant agreement in negotiation is between the EU and Mercosul, where tariffs are the most important issue in discussion. The main purpose of this paper is to shows that tariff are important for all these agreements, not because of its nominal value, but because the impacts of exchange rate misalignments on tariffs are so significant that all concessions can be distorted by overvalued and by devaluated currencies. The article is divided into several sections: the first gives an introduction to the issue; the second explains the methodologies used to determine exchange rate misalignments and also presents some results for Brazil, US and China; the third summarizes the methodology applied to calculate the impacts of exchange rate misalignments on the level of tariff protection through an exercise of “misalignment tariffication” and examines the effects of exchange rate variations on tariffs and their consequences for the multilateral trading system; the fourth creates a methodology to estimate exchange rates against a basket of currencies (a virtual currency of the World) and a proposal to deal with persistent and significant misalignments related to trade rules. The fifth presents some estimates for the main PTAs. The conclusions are present in the last section
Resumo:
Internal residual stresses significantly influence the fatigue strength of coated materials. It is well known that chromium plating is the most used electrodeposited coating for important industrial applications. However, pressure to identify alternatives or to improve the chromium electroplating process have increased in recent years, related to the reduction in fatigue strength of the base material and to environmental requirements. The high efficiency and fluoride free hard chromium electroplating there called accelerated) is an improvement to the conventional process. One environmentally safer and cleaner alternative to hard chromium plating is tungsten carbide thermal spray coating applied by the High Velocity Oxy-Fuel (HVOF) process. To increase the fatigue strength of chromium plated materials, coating thickness and microcracks density are important parameters to be controlled. Techniques as compressive residual stresses induced by shot peening and multilayers, are also used. The aim of this study was to analyse the effects on AISI 4340 steel, in the rotating bending fatigue behaviour, of the: tungsten carbide thermal spray coating applied by HP/HVOF process; chemical nickel underplate, and shot peening process applied before coating deposition, in comparison to hard chromium electroplatings. Rotating bending fatigue test results indicate better performance for the conventional hard chromium plating in relation to the accelerated hard chromium electroplating. Tungsten carbide thermal spray coating and accelerated hard chromium plate over nickel resulted in higher fatigue strength when compared to samples conventional or accelerated hard chromium plated. Shot peening showed to be an excellent alternative to increase fatigue strength of AISI 4340 steel hard chromium electroplated. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
The aim of this study was to analyze the effect of successive TIG (tungsten inert gas) welding repairs on the reverse bending fatigue strength of AISI 4130 steel, which is widely used in components critical to the flight-safety. In order to simulate the abrupt maneuvers, wind bursts, motor vibration and helixes efforts, which generate cyclic bending loadings at the welded joints of a specific aircraft component called motor cradle, experimental reverse bending fatigue tests were carried out on specimens made from hot-rolled steel plate, 1.10 mm (0.043 in) thick, by mean of a SCHENK PWS equipment, with load ratio R = -1, under constant amplitude, at 30 Hz frequency and room temperature. It was observed that the bending fatigue strength decreases after the TIG (Tungsten Inert Gas) welding process application on AISI 4130 steel, with subsequent decrease due to re-welding sequence as well. Microstructural analyses and microhardness measurements on the base material, heat-affected zone (HAZ) and weld metal, as well as the effects of the weld bead geometry on the obtained results, have complemented this study.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)