991 resultados para Abdominal computed tomographic scan


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe a case of a focal right ventricular rupture following removal of a rib-associated telangiectatic osteosarcoma (TOS) in a dog. CASE SUMMARY: A 2-year-old spayed female mixed-breed dog, weighing 20 kg, was presented in compensated hypovolemic shock due to active bleeding into the thoracic cavity. The dog was stabilized with appropriate fluid administration. Subsequent computed tomographic examination revealed a large mineralized mass originating from the body of a rib and displacing the heart. Two days after surgical removal of this mass, focal right ventricular rupture occurred and the dog died. The mass was later identified as a TOS. NEW OR UNIQUE INFORMATION PROVIDED: Although hemothorax secondary to TOS has been described previously, this report describes for the first time, spontaneous focal right ventricular rupture as a rare complication of thoracotomy and rib resection for the removal of a rib-associated, intrathoracic TOS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An 11-year-old neutered female domestic shorthair indoor cat was presented to our hospital for treatment of a left-sided rostro-temporal basal meningioma. Focal seizures in the facial muscles had been observed sporadically for 1 year. Two weeks prior to presentation the cat had developed generalised seizures and was treated with symptomatic anticonvulsive treatment. Focal facial seizures, especially on the right side, persisted after medical therapy. From the computed tomography scan, a basal meningioma was suspected by the treating veterinarian. A left-sided suprazygomatical temporobasal approach to the zygomatic arch was chosen because it causes less soft tissue damage. After craniotomy, durotomy and gentle dorsal retraction of the left piriform lobe, the meningioma was removed. Postoperative magnetic resonance imaging confirmed complete excision of the tumour. One day after surgery the cat was alert and a left-sided facial nerve palsy was noticed. Otherwise the neurological examination was normal. Anticonvulsive and eye moistening therapy was continued for 3 months. Six months after surgery the cat was clinically normal without any recurrence of seizures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Early implant placement with simultaneous contour augmentation is documented with short- and medium-term studies. The long-term stability of contour augmentation is uncertain. METHODS In this prospective, cross-sectional study, 41 patients with an implant-borne single crown were examined twice, in 2006 and 2010. Clinical, radiologic, and esthetic parameters were assessed at both examinations. In addition, a cone beam computed tomographic (CBCT) image was obtained during the second examination to assess the dimensions of the facial bone wall. RESULTS All 41 implants demonstrated ankylotic stability without signs of peri-implant infection at both examinations. The clinical parameters remained stable over time. Satisfactory esthetic outcomes were noted, as assessed by the pink and white esthetic score (PES/WES) indices. Overall, the PES scores were slightly higher than the WES scores. None of the implants developed mucosal recession over time, as confirmed by values of the distance between implant shoulder and mucosal margin and cast measurements. The periapical radiographs yielded stable peri-implant bone levels, with a mean distance between implant shoulder and first visible bone-implant contact value of 2.18 mm. The CBCT analysis demonstrated a mean thickness of the facial bone wall ≈2.2 mm. In two implants (4.9%) no facial bone wall was detectable radiographically. CONCLUSIONS This prospective cross-sectional study demonstrates stable peri-implant hard and soft tissues for all 41 implants examined and satisfactory esthetic outcomes overall. The follow-up of 5 to 9 years confirmed again that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration was able to establish and maintain a facial bone wall in 95% of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES This study prospectively evaluated the role of a novel 3-dimensional, noninvasive, beat-by-beat mapping system, Electrocardiographic Mapping (ECM), in facilitating the diagnosis of atrial tachycardias (AT). BACKGROUND Conventional 12-lead electrocardiogram, a widely used noninvasive tool in clinical arrhythmia practice, has diagnostic limitations. METHODS Various AT (de novo and post-atrial fibrillation ablation) were mapped using ECM followed by standard-of-care electrophysiological mapping and ablation in 52 patients. The ECM consisted of recording body surface electrograms from a 252-electrode-vest placed on the torso combined with computed tomography-scan-based biatrial anatomy (CardioInsight Inc., Cleveland, Ohio). We evaluated the feasibility of this system in defining the mechanism of AT-macro-re-entrant (perimitral, cavotricuspid isthmus-dependent, and roof-dependent circuits) versus centrifugal (focal-source) activation-and the location of arrhythmia in centrifugal AT. The accuracy of the noninvasive diagnosis and detection of ablation targets was evaluated vis-à-vis subsequent invasive mapping and successful ablation. RESULTS Comparison between ECM and electrophysiological diagnosis could be accomplished in 48 patients (48 AT) but was not possible in 4 patients where the AT mechanism changed to another AT (n = 1), atrial fibrillation (n = 1), or sinus rhythm (n = 2) during the electrophysiological procedure. ECM correctly diagnosed AT mechanisms in 44 of 48 (92%) AT: macro-re-entry in 23 of 27; and focal-onset with centrifugal activation in 21 of 21. The region of interest for focal AT perfectly matched in 21 of 21 (100%) AT. The 2:1 ventricular conduction and low-amplitude P waves challenged the diagnosis of 4 of 27 macro-re-entrant (perimitral) AT that can be overcome by injecting atrioventricular node blockers and signal averaging, respectively. CONCLUSIONS This prospective multicenter series shows a high success rate of ECM in accurately diagnosing the mechanism of AT and the location of focal arrhythmia. Intraprocedural use of the system and its application to atrial fibrillation mapping is under way.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

HYPOTHESIS Facial nerve monitoring can be used synchronous with a high-precision robotic tool as a functional warning to prevent of a collision of the drill bit with the facial nerve during direct cochlear access (DCA). BACKGROUND Minimally invasive direct cochlear access (DCA) aims to eliminate the need for a mastoidectomy by drilling a small tunnel through the facial recess to the cochlea with the aid of stereotactic tool guidance. Because the procedure is performed in a blind manner, structures such as the facial nerve are at risk. Neuromonitoring is a commonly used tool to help surgeons identify the facial nerve (FN) during routine surgical procedures in the mastoid. Recently, neuromonitoring technology was integrated into a commercially available drill system enabling real-time monitoring of the FN. The objective of this study was to determine if this drilling system could be used to warn of an impending collision with the FN during robot-assisted DCA. MATERIALS AND METHODS The sheep was chosen as a suitable model for this study because of its similarity to the human ear anatomy. The same surgical workflow applicable to human patients was performed in the animal model. Bone screws, serving as reference fiducials, were placed in the skull near the ear canal. The sheep head was imaged using a computed tomographic scanner and segmentation of FN, mastoid, and other relevant structures as well as planning of drilling trajectories was carried out using a dedicated software tool. During the actual procedure, a surgical drill system was connected to a nerve monitor and guided by a custom built robot system. As the planned trajectories were drilled, stimulation and EMG response signals were recorded. A postoperative analysis was achieved after each surgery to determine the actual drilled positions. RESULTS Using the calibrated pose synchronized with the EMG signals, the precise relationship between distance to FN and EMG with 3 different stimulation intensities could be determined for 11 different tunnels drilled in 3 different subjects. CONCLUSION From the results, it was determined that the current implementation of the neuromonitoring system lacks sensitivity and repeatability necessary to be used as a warning device in robotic DCA. We hypothesize that this is primarily because of the stimulation pattern achieved using a noninsulated drill as a stimulating probe. Further work is necessary to determine whether specific changes to the design can improve the sensitivity and specificity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine whether a 3-mm isotropic target margin adequately covers the prostate and seminal vesicles (SVs) during administration of an intensity-modulated radiation therapy (IMRT) treatment fraction, assuming that daily image-guided setup is performed just before each fraction. MATERIALS AND METHODS: In-room computed tomographic (CT) scans were acquired immediately before and after a daily treatment fraction in 46 patients with prostate cancer. An eight-field IMRT plan was designed using the pre-fraction CT with a 3-mm margin and subsequently recalculated on the post-fraction CT. For convenience of comparison, dose plans were scaled to full course of treatment (75.6 Gy). Dose coverage was assessed on the post-treatment CT image set. RESULTS: During one treatment fraction (21.4+/-5.5 min), there were reductions in the volumes of the prostate and SVs receiving the prescribed dose (median reduction 0.1% and 1.0%, respectively, p<0.001) and in the minimum dose to 0.1 cm(3) of their volumes (median reduction 0.5 and 1.5 Gy, p<0.001). Of the 46 patients, three patients' prostates and eight patients' SVs did not maintain dose coverage above 70 Gy. Rectal filling correlated with decreased percentage-volume of SV receiving 75.6, 70, and 60 Gy (p<0.02). CONCLUSIONS: The 3-mm intrafractional margin was adequate for prostate dose coverage. However, a significant subset of patients lost SV dose coverage. The rectal volume change significantly affected SV dose coverage. For advanced-stage prostate cancers, we recommend to use larger margins or improve organ immobilization (such as with a rectal balloon) to ensure SV coverage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Given the fragmentation of outpatient care, timely follow-up of abnormal diagnostic imaging results remains a challenge. We hypothesized that an electronic medical record (EMR) that facilitates the transmission and availability of critical imaging results through either automated notification (alerting) or direct access to the primary report would eliminate this problem. METHODS: We studied critical imaging alert notifications in the outpatient setting of a tertiary care Department of Veterans Affairs facility from November 2007 to June 2008. Tracking software determined whether the alert was acknowledged (ie, health care practitioner/provider [HCP] opened the message for viewing) within 2 weeks of transmission; acknowledged alerts were considered read. We reviewed medical records and contacted HCPs to determine timely follow-up actions (eg, ordering a follow-up test or consultation) within 4 weeks of transmission. Multivariable logistic regression models accounting for clustering effect by HCPs analyzed predictors for 2 outcomes: lack of acknowledgment and lack of timely follow-up. RESULTS: Of 123 638 studies (including radiographs, computed tomographic scans, ultrasonograms, magnetic resonance images, and mammograms), 1196 images (0.97%) generated alerts; 217 (18.1%) of these were unacknowledged. Alerts had a higher risk of being unacknowledged when the ordering HCPs were trainees (odds ratio [OR], 5.58; 95% confidence interval [CI], 2.86-10.89) and when dual-alert (>1 HCP alerted) as opposed to single-alert communication was used (OR, 2.02; 95% CI, 1.22-3.36). Timely follow-up was lacking in 92 (7.7% of all alerts) and was similar for acknowledged and unacknowledged alerts (7.3% vs 9.7%; P = .22). Risk for lack of timely follow-up was higher with dual-alert communication (OR, 1.99; 95% CI, 1.06-3.48) but lower when additional verbal communication was used by the radiologist (OR, 0.12; 95% CI, 0.04-0.38). Nearly all abnormal results lacking timely follow-up at 4 weeks were eventually found to have measurable clinical impact in terms of further diagnostic testing or treatment. CONCLUSIONS: Critical imaging results may not receive timely follow-up actions even when HCPs receive and read results in an advanced, integrated electronic medical record system. A multidisciplinary approach is needed to improve patient safety in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An exponential increase in the use of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis has been witnessed over the recent years. The current article reviews different areas of uncertainty related to patient selection. The use and limitations of risk scores are addressed, followed by an extensive discussion on the value of three-dimensional imaging for prosthesis sizing and the assessment of complex valve anatomy such as degenerated bicuspid valves. The uncertainty about valvular stenosis severity in patients with a mismatch between the transvalvular gradient and the aortic valve area, and how integrated use of echocardiography and computed tomographic imaging may help, is also addressed. Finally, patients referred for TAVI may have concomitant mitral regurgitation and/or coronary artery disease and the management of these patients is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Endovascular aortic repair (EVAR) necessitates lifelong surveillance for the patient, in order to detect complications timely. Endoleaks (ELs) are among the most common complications of EVAR. Especially type II ELs can have a very unpredictable clinical course and this can range from spontaneous sealing to aortic rupture. Subgroups of this type of EL need to be identified in order to make a proper risk stratification. Aim of this review is to describe the existing imaging techniques, including their advantages and disadvantages in the context of post-EVAR surveillance with a particular emphasis on low-flow ELs. Low flow ELs cause pressurization of the aortic aneurysm sac with a low velocity filling, leading to difficulty of detection by routine imaging protocols for EVAR surveillance, e.g. bi- or triphasic multislice computed tomographic angiography, magnetic resonance imaging and contrast enhanced ultrasound. In this article, we review the imaging possibilities of ELs and discuss the different imaging strategies available for depicting low flow ELs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The results of Interventional Management of Stroke (IMS) III, Magnetic Resonance and REcanalization of Stroke Clots Using Embolectomy (MR RESCUE), and SYNTHESIS EXPANSION trials are expected to affect the practice of endovascular treatment for acute ischemic stroke. The purpose of this report is to review the components of the designs and methods of these trials and to describe the influence of those components on the interpretation of trial results. METHODS A critical review of trial design and conduct of IMS III, MR RESCUE, and SYNTHESIS EXPANSION is performed with emphasis on patient selection, shortcomings in procedural aspects, and methodology of data ascertainment and analysis. The influence of each component is estimated based on published literature including multicenter clinical trials reporting on endovascular treatment for acute ischemic stroke and myocardial infarction. RESULTS We critically examined the time interval between symptom onset and treatment and rates of angiographic recanalization to differentiate between "endovascular treatment" and "parameter optimized endovascular treatment" as it relates to the IMS III, MR RESCUE, and SYNTHESIS EXPANSION trials. All the three trials failed to effectively test "parameter optimized endovascular treatment" due to the delay between symptom onset and treatment and less than optimal rates of recanalization. In all the three trials, the magnitude of benefit with endovascular treatment required to reject the null hypothesis was larger than could be expected based on previous studies. The IMS III and SYNTHESIS EXPANSION trials demonstrated that rates of symptomatic intracerebral hemorrhages subsequent to treatment are similar between IV thrombolytics and endovascular treatment in matched acute ischemic stroke patients. The trials also indirectly validated the superiority/equivalence of IV thrombolytics (compared with endovascular treatment) in patients with minor neurological deficits and those without large vessel occlusion on computed tomographic/magnetic resonance angiography. CONCLUSIONS The results do not support a large magnitude benefit of endovascular treatment in subjects randomized in all the three trials. The possibility that benefits of a smaller magnitude exist in certain patient populations cannot be excluded. Large magnitude benefits can be expected with implementation of "parameter optimized endovascular treatment" in patients with ischemic stroke who are candidates for IV thrombolytics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. MATERIALS AND METHODS A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. RESULTS 53 questionnaires (30 %) were assessable, corresponding to more than 72 % of the patients referred. Of the referring physicians who responded, 94 % saw a concrete advantage of CCTA in the treatment of patients, whereby 87 % were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1 - 5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42 % of the referring physicians. 90 % of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87 % of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CONCLUSION CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many end-stage heart failure patients are not eligible to undergo heart transplantation due to organ shortage, and even those under consideration for transplantation might suffer long waiting periods. A better understanding of the hemodynamic impact of left ventricular assist devices (LVAD) on the cardiovascular system is therefore of great interest. Computational fluid dynamics (CFD) simulations give the opportunity to study the hemodynamics in this patient population using clinical imaging data such as computed tomographic angiography. This article reviews a recent study series involving patients with pulsatile and constant-flow LVAD devices in which CFD simulations were used to qualitatively and quantitatively assess blood flow dynamics in the thoracic aorta, demonstrating its potential to enhance the information available from medical imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The aim of this study was to evaluate the concordance of 2- and 3-dimensional radiography and histopathology in the diagnosis of periapical lesions. METHODS Patients were consecutively enrolled in this study provided that preoperative periapical radiography (PR) and cone-beam computed tomographic imaging of the tooth to be treated with apical surgery were performed. The periapical lesional tissue was histologically analyzed by 2 blinded examiners. The final histologic diagnosis was compared with the radiographic assessments of 4 blinded observers. The initial study material included 62 teeth in the same number of patients. RESULTS Four lesions had to be excluded during processing, resulting in a final number of 58 evaluated cases (31 women and 27 men, mean age = 55 years). The final histologic diagnosis of the periapical lesions included 55 granulomas (94.8%) and 3 cysts (5.2%). Histologic analysis of the tissue samples from the apical lesions exhibited an almost perfect agreement between the 2 experienced investigators with an overall agreement of 94.83% (kappa = 0.8011). Radiographic assessment overestimated cysts by 28.4% (cone-beam computed tomographic imaging) and 20.7% (periapical radiography), respectively. Comparing the correlation of the radiographic diagnosis of 4 observers with the final histologic diagnosis, 2-dimensional (kappa = 0.104) and 3-dimensional imaging (kappa = 0.111) provided only minimum agreement. CONCLUSIONS To establish a final diagnosis of an apical radiolucency, the tissue specimen should be evaluated histologically and specified as a granuloma (with/without epithelium) or a cyst. Analysis of 2-dimensional and 3-dimensional radiographic images alike results only in a tentative diagnosis that should be confirmed with biopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To report clinical signs, diagnostic imaging findings, and outcome in a dog with traumatic myositis ossificans of the origin of the extensor carpi radialis muscle. STUDY DESIGN Clinical report. ANIMALS An 8-month-old intact female Irish Setter Dog. METHODS After radiographic and computed tomographic evaluation of an osseous proliferation arising from the cranial cortex of the right distal humeral diaphysis, the protruding bone was surgically removed and evaluated by histopathology. RESULTS Traumatic myositis ossificans was successfully treated with surgical removal of the osseous proliferation resulting in improved postoperative range of motion of the right elbow joint. There was no evidence of lameness or abnormal bone regrowth associated with the surgical site radiographically at follow up. CONCLUSION Surgical removal of a traumatic myositis ossificans lesion resulted in full return to function in a young, competitive show dog.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.