986 resultados para ASSISTED THORACIC-SURGERY


Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is a frequent arrhythmia after conventional coronary artery bypass grafting. With the advent of minimally invasive technique for left internal mammary artery-left anterior descending coronary artery (LIMA-LAD) grafting, we analyzed the incidence and the risk factors of postoperative AF in this patient population. This prospective study involves all patients undergoing isolated LIMA-LAD grafting with minimally invasive technique between January 1994 and June 2000. Twenty-four possible risk factors for postoperative AF were entered into univariate and multivariate logistic regression analyses. Postoperative AF occurred in 21 of the 90 patients (23.3%) analyzed. Double- or triple-vessel disease was present in 12/90 patients (13.3%). On univariate analysis, right coronary artery disease (p <0.01), age (p = 0.01), and diabetes (p = 0.04) were found to be risk factors for AF. On multivariate analysis, right coronary artery disease was identified as the sole significant risk factor (p = 0.02). In this patient population, the incidence of AF after minimally invasive coronary artery bypass is in the range of that reported for conventional coronary artery bypass grafting. Right coronary artery disease was found to be an independent predictor, and this may be related to the fact that in this patient population the diseased right coronary artery was not revascularized at the time of the surgical procedure. For the same reason, this risk factor may find a broader application to noncardiac thoracic surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Sleep disordered breathing with central apnea or hypopnea frequently occurs during sleep at high altitude. The aim of this study was to assess the effects of added dead space (DS) on sleep disordered breathing and transcutaneous CO2 (PtcCO2) level during sleep at high altitude. Methods: Full night sleep recordings were obtained on 12 unacclimatized mountaineers (11 males, 1 female, mean age 39 ± 12 y.o.) during one of the first 4 nights after arrival in Leh, Ladakh (3500 m). In random order, half of the night was spent with a 500 ml increase in dead space through a custom designed full face mask and the other half without it. PtcCO2 was measured in 3 participants. Results: Baseline recordings reveled two clearly distinct groups: one with severe sleep disordered breathing (n = 5) and the other with mild or no disordered breathing (n = 7). Added dead space markedly improved breathing in the first group (baseline vs DS): apnea hypopnea index (AHI) 70.3 ± 25.8 vs 29.4 ± 6.9 (p = 0.013), oxygen desaturation index (ODI): 72.9 ± 24.1/h vs 42.5 ± 14.4 (p = 0.031), whereas it had no significant effect in the second group. Added dead space did not have a significant effect on mean oxygen saturation level. Respiratory events were almost exclusively central apnea or hypopnea except for one subject. Only a minor increase in mean PtcCO2 (n = 3) was observed: 33.6 ± 1.8 mm Hg at baseline and 35.0 ± 2.62 mm Hg with DS. Sleep quality was preserved under dead space condition, since the microarousal rate remained unchanged (16.8 ± 8.7/h vs 19.4 ± 18.6/h (p = 0.51). Conclusion: In mountaineers with severe sleep disordered breathing at high altitude, a 500 ml increase in dead space through a fitted mask significantly improves nocturnal breathing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Use of cardiopulmonary bypass for emergency resuscitation is not new. In fact, John Gibbon proposed this concept for the treatment of severe pulmonary embolism in 1937. Significant progress has been made since, and two main concepts for cardiac assist based on cardiopulmonary bypass have emerged: cardiopulmonary support (CPS) and extracorporeal membrane oxygenation (ECMO). The objective of this review is to summarize the state of the art in these two technologies. METHODS: Configuration of CPS is now fairly standard. A mobile cart with relatively large wheels allowing for easy transportation carries a centrifugal pump, a back-up battery with a charger, an oxygen cylinder, and a small heating system. Percutaneous cannulation, pump-driven venous return, rapid availability, and transportability are the main characteristics of a CPS system. Cardiocirculatory arrest is a major predictor of mortality despite the use of CPS. In contrast, CPS appears to be a powerful tool for patients in cardiogenic shock before cardiocirculatory arrest, requiring some type of therapeutic procedures, especially repair of anatomically correctable problems or bridging to other mechanical circulatory support systems such as ventricular assist devices. CPS is in general not suitable for long-term applications because of the small-bore cannulas, resulting in significant pressure gradients and eventually hemolysis. RESULTS: In contrast, ECMO can be designed for longer-term circulatory support. This requires large-bore cannulas and specifically designed oxygenators. The latter are either plasma leakage resistent (true membranes) or relatively thrombo-resistant (heparin coated). Both technologies require oxygenator changeovers although the main reason for this is different (clotting for the former, plasma leakage for the latter). Likewise, the tubing within a roller pump has to be displaced and centrifugal pump heads have to be replaced over time. ECMO is certainly the first choice for a circulatory support system in the neonatal and pediatric age groups, where the other assist systems are too bulky. ECMO is also indicated for patients improving on CPS. Septic conditions are, in general, considered as contraindications for ECMO. CONCLUSIONS: Ease of availability and moderate cost of cardiopulmonary bypass-based cardiac support technologies have to be balanced against the significant immobilization of human resources, which is required to make them successful.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Benign mature teratomas are the most common type of germ cell tumors that arise in the anterior mediastinum. Intrapericardial teratomas are a rare manifestation of this tumor type, which are generally diagnosed during infancy because of the heart compression symptoms they produce. Here we report a rare case of intrapericardial mature teratoma that was incidentally discovered in an asymptomatic 51-year-old woman.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study is to create a standard test to approve the efficacy of a surgical sealant. An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives. METHODS: Samples were composed of two circular layers of equine pericardium glued by the surgical sealant studied. The sample was fixed to a support with an industrial glue. The support and the bottom layer were perforated in the centre to allow injection of pressurised water. Water was progressively introduced through the hole in the support and the bottom layer to create a blister with constant radius, increasing height and internal pressure during this first step. At a critical pressure, delamination started, the radius and height of the blister increased and the pressure decreased. At this point, the adhesion energy could be determined. The experimental parameters were measured with a pressure sensor and an optical profilometry device for deflection. RESULTS: Adhesion testing was carried out in eight paired equine pericardium samples bonded with a Dermabond cyanoacrylate glue. The average value of the practical adhesion energy is 2.3 Jm(-2) with a standard deviation of 1.5 Jm(-2). CONCLUSION: Application of the bulge-and-blister test to the surgical field was achieved and allowed a quantification of adhesion of a surgical glue. Such information is essential to compare the different surgical glues presently available. The study of the impact of bonding conditions such as pressure, hygrometry or setting conditions will provide a better understanding of the characteristics of adhesion in the surgical field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging. METHODS: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients. RESULTS: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed. CONCLUSIONS: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Exposure to environmental tobacco smoke (ETS) is a major environmental risk factor. Indoor contaminants come from a variety of sources, which can include inadequate ventilation, volatile organic compounds (VOCs), biological agents, combustion products, and ETS. Because ETS is one of the most frequent causes of IAQ complaints as well as the high mortality of passive smoking, in June 2004 the University of Geneva made the decision to ban smoking inside the so called "Uni-Mail" building, the biggest Swiss University human science building of recent construction, and the ordinance was applied beginning in October 2004. This report presents the finding related to the IAQ of the "Uni-Mail" building before and after smoking bans using nicotine, suspended dust, condensate and PAHs level in air as tracers to perform an assessment of passive tobacco exposure for non-smokers inside the building. Methods: Respirable particles (RSP) A real time aerosol monitor (model DataRAM)was place at sampling post 1, level ground floor. Condensate It consists in extracting any organic matter taken on the glass fibre filters by MeOH, and then measuring the total absorbent of the MeOH extract to the UV wavelength of 447 nm. Nicotine Nicotine was taken by means of cartridges containing of XAD-4 to the fixed flow of 0.5 L/min. The analytical method used for the determination of nicotine is based on gas chromatography with Nitrogen selective detector GC-NPD. Results: Figure 1 shows the box plot density display of 3 parameters before and after smoking bans for all 7 sampling posts: dust, condensate and nicotine in air in μg/m3. Conclusion: Before the smoking ban, the level of the concentrations of respirable particles (RSP) is raised more, average of the day 320 μg/m3, with peaks of more than 1000 μg/m3, compared with the values of the surrounding air between 22 and 30 μg/m3. The nicotine level is definitely more important (average 5.53 μg/m3, field 1.5 to 17.9 μg/m3). Once the smoking bans inside the building were applied, one notes a clear improvement in terms of concentrations of pollutants. For dust, the concentration fell by 3 times (average: 130 μg/m3, range: 40 to 160 μg/m3) and that of nicotine by 10 times (average: 0.53 μg/m3, range: 0 to 1.69 μg/m3) compared to that found before smoking bans. The outdoor air RSP concentration was 22 μg/m3 or 10 times lower. Nicotine seems to be the best tracer for ETS free of interference, independent of location or season.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Respiratory care is universally recognised as useful, but its indications and practice vary markedly. In order to improve appropriateness of respiratory care in our hospital, we developed evidence-based local guidelines in a collaborative effort involving physiotherapists, physicians, and health services researchers. Methods: Recommendations were developed using the standardised RAND appropriateness method. A literature search was performed for the period between 1995 and 2008 based on terms associated with guidelines and with respiratory care. Publications were assessed according to the Oxford classification of quality of evidence. A working group prepared proposals for recommendations which were then independently rated by a multidisciplinary expert panel. All recommendations were then discussed in common and indications for procedures were rated confidentially a second time by the experts. Each indication for respiratory care was classified as appropriate, uncertain, or inappropriate, based on the panel median rating and the degree of intra-panel agreement. Results: Recommendations were formulated for the following procedures: non-invasive ventilation, continuous positive airway pressure, intermittent positive pressure breathing, intrapulmonary percussive ventilation, mechanical insufflation-exsufflation, incentive spirometry, positive expiratory pressure, nasotracheal suctioning, noninstrumental airway clearance techniques. Each recommendation referred to a particular medical condition, and was assigned to a hierarchical category based on the quality of evidence from literature supporting the recommendation and on the consensus of experts. Conclusion: Despite a marked heterogeneity of scientific evidence, the method used allowed us to develop commonly agreed local guidelines for respiratory care. In addition, this work fostered a closer relationship between physiotherapists and physicians in our institution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Assess the performance of self-expanding venous cannulas for routine use in open-heart surgery. METHODS: Prospective study in 100 unselected consecutive patients undergoing open-heart surgery with either remote or central smart venous cannulation. RESULTS: The study focuses on the 76 consecutive adult patients (mean age 59.2+/-17.3 years; 60 males, 16 females) undergoing surgical procedures with total cardiopulmonary bypass for either valve procedures (42/76 patients=55.3%), ascending aorta and arch repair (20/76 patients=26.3%), coronary artery revascularization (13/76 patients=17.1%) or other procedures (11/76 patients=14.5%) with 14/76 patients (18.4%) undergoing redo surgery and 6/76 patients (7.9%) undergoing small access surgery. The mean pump flow achieved by gravity drainage alone accounted for 5.0+/-0.6l/min (=114% of target) in the entire study population (n=76) as compared to the calculated, theoretical pump flow of 4.4+/-0.5l/min (p<0.0001). For the femoral cannulation sub-group (n=35) pump flow achieved by gravity drainage alone accounted for 4.9+/-0.6l/min (=114% of target) as compared to the calculated theoretical pump flow of 4.3+/-0.4l/min (p<0.0001). The corresponding numbers for trans-subclavian cannulation (n=7) are 5.2+/-0.5l/min (111%) for the pump flow achieved by gravity drainage as compared to the theoretical target flow of 4.7+/-0.4l/min. For the central cannulation sub-group (n=34) mean flow achieved by gravity drainage with a self-expanding venous cannula accounted for 5.1+/-0.7l/min (=116% of target) as compared to the calculated theoretical flow of 4.4+/-0.6l/min (p<0.0001). CONCLUSION: Full or more than target flow was achieved in 97% of the patients studied undergoing CPB with self-expanding venous cannulas and gravity drainage. Remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. Augmentation of venous return is no longer necessary.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Prospective assessment of pedicled extrathoracic muscle flaps for the closure of large intrathoracic airway defects after noncircumferential resection in situations where an end-to-end reconstruction seemed risky (defects of > 4-cm length, desmoplastic reactions after previous infection or radiochemotherapy). METHODS: From 1996 to 2001, 13 intrathoracic muscle transpositions (6 latissimus dorsi and 7 serratus anterior muscle flaps) were performed to close defects of the intrathoracic airways after noncircumferential resection for tumor (n = 5), large tracheoesophageal fistula (n = 2), delayed tracheal injury (n = 1) and bronchopleural fistula (n = 5). In 2 patients, the extent of the tracheal defect required reinforcement of the reconstruction by use of a rib segment embedded into the muscle flap followed by temporary tracheal stenting. Patient follow-up was by clinical examination bronchoscopy and biopsy, pulmonary function tests, and dynamic virtual bronchoscopy by computed tomographic (CT) scan during inspiration and expiration. RESULTS: The airway defects ranged from 2 x 1 cm to 8 x 4 cm and involved up to 50% of the airway circumference. They were all successfully closed using muscle flaps with no mortality and all patients were extubated within 24 hours. Bronchoscopy revealed epithelialization of the reconstructions without dehiscence, stenosis, or recurrence of fistulas. The flow-volume loop was preserved in all patients and dynamic virtual bronchoscopy revealed no significant difference in the endoluminal cross surface areas of the airway between inspiration and expiration above (45 +/- 21 mm(2)), at the site (76 +/- 23 mm(2)) and below the reconstruction (65 +/- 40 mm(2)). CONCLUSIONS: Intrathoracic airway defects of up to 50% of the circumference may be repaired using extrathoracic muscle flaps when an end-to-end reconstruction is not feasible.