934 resultados para AC to AC converter


Relevância:

50.00% 50.00%

Publicador:

Resumo:

The higher harmonic components available from large-amplitude Fourier-transformed alternating current (FT-ac) voltammetry enable the surface active state of a copper electrode in basic media to be probed in much more detail than possible with previously used dc methods. In particular, the absence of capacitance background current allows low-level Faradaic current contributions of fast electron-transfer processes to be detected; these are usually completely undetectable under conditions of dc cyclic voltammetry. Under high harmonic FT-ac voltammetric conditions, copper electrodes exhibit well-defined and reversible premonolayer oxidation responses at potentials within the double layer region in basic 1.0 M NaOH media. This process is attributed to oxidation of copper adatoms (Cu*) of low bulk metal lattice coordination numbers to surface-bonded, reactive hydrated oxide species. Of further interest is the observation that cathodic polarization in 1.0 M NaOH significantly enhances the current detected in each of the fundamental to sixth FT-ac harmonic components in the Cu*/Cu hydrous oxide electron-transfer process which enables the underlying electron transfer processes in the higher harmonics to be studied under conditions where the dc capacitance response is suppressed; the results support the incipient hydrous oxide adatom mediator (IHOAM) model of electrocatalysis. The underlying quasi-reversible interfacial Cu*/Cu hydrous oxide process present under these conditions is shown to mediate the reduction of nitrate at a copper electrode, while the mediator for the hydrazine oxidation reaction appears to involve a different mediator or active state redox couple. Use of FT-ac voltammetry offers prospects for new insights into the nature of active sites and electrocatalysis at the electrode/solution interface of Group 11 metals in aqueous media.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

When, in 1977, the Australian electorate provided a double majority to effect a change of section 72 of the Commonwealth Constitution requiring judges of the High Court of Australia to retire at the age of 70 years old, I doubt we understood the continuing capacity of these esteemed members of the judiciary. For the opportunity to sit and talk with Ian Callinan AC who, in compliance with that amendment, retired from the High Court in September 2007, I needed to wait until he returned from The Hague where he was sitting as a Judge ad hoc on the International Court of Justice. Although a native of Casino, New South Wales, Mr Callinan is regarded as a Queenslander. Indeed, he grew up in Brisbane, finished high school at Brisbane Grammar and graduated in law at The University of Queensland. Appointed in 1978 as a Queen’s Counsel, Mr Callinan enjoyed this period of his legal career and we discussed an aspect of the Christopher Skase case, which reinforced my belief that Mr Callinan is an incredibly skilful advocate. On 14 September 1998, ABC Four Corners broadcasted the views of some prominent Australians on the appointment of Mr Callinan to the High Court. In assessing the type of person Mr Callinan is, Tony Morris QC said: “Ian Callinan isn't a coward”, while former Commonwealth Attorney-General, Michael Lavarch, said: “He was regarded as an absolutely outstanding criminal lawyer within the Queensland legal profession, I mean really a top-notch advocate”. I was not interested in raising any of the controversial issues that Mr Callinan has encountered as an advocate in high profile matters. I wanted to know how he felt about his time on the High Court, what his thoughts are on the operation of the High Court, the IP cases he decided, the real life issues that he feels impact on counsel who are appearing before the High Court and the people he regarded as role models. During our conversation, Mr Callinan laughed often and when he did his eyes lit up, revealing his passion for life. He is an incredibly genuine Australian who loved his time as a barrister, enjoyed his role on the High Court, enjoys his current job as mediator, loves writing novels, has a great desire for continual improvement in the quality of legal education and legal advocacy and sees a need for change in IP law. When I asked: “So, what might the future hold for you?”, he laughed and said: “Well, at my age I don’t have a long horizon time”. I said: “Just enjoy the journey?”, to which Mr Callinan responded: “Exactly”.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

With ever-increasing share of power electronic loads constant power instability is becoming a significant issue in microgrids, especially when they operate in the islanding mode. Transient conditions like resistive load-shedding or sudden increase of constant power loads (CPL) might destabilize the whole system. Modeling and stability analysis of AC microgrids with CPLs have already been discussed in literature. However, no effective solutions are provided to stabilize this kind of system. Therefore, this paper proposes a virtual resistance based active damping method to eliminate constant power instability in AC microgrids. Advantages and limitations of the proposed method are also discussed in detail. Simulation results are presented to validate the proposed active damping solution.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A Z-source inverter based grid-interface for a variable-speed wind turbine connected to a permanent magnet synchronous generator is proposed. A control system is designed to harvest maximum wind energy under varied wind conditions with the use of the permanent magnet synchronous generator, diode-rectifier and Z-source inverter. Control systems for speed regulation of the generator and for DC- and AC- sides of the Z-source inverter are investigated using computer simulations and laboratory experiments. Simulation and experimental results verify the efficacy of the proposed approach.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A pulsewidth modulation (PWM) technique is proposed for minimizing the rms torque ripple in inverter-fed induction motor drives subject to a given average switching frequency of the inverter. The proposed PWM technique is a combination of optimal continuous modulation and discontinuous modulation. The proposed technique is evaluated both theoretically as well as experimentally and is compared with well-known PWM techniques. It is shown that the proposed method reduces the rms torque ripple by about 30% at the rated speed of the motor drive, compared to conventional space vector PWM.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper presents the modeling and analysis of a voltage source converter (VSC) based back-to-back (BTB) HVDC link. The case study considers the response to changes in the active and reactive power and disturbance caused by single line to ground (SLG) fault. The controllers at each terminal are designed to inject a variable (magnitude and phase angle) sinusoidal, balanced set of voltages to regulate/control the active and reactive power. It is also possible to regulate the converter bus (AC) voltage by controlling the injected reactive power. The analysis is carried out using both d-q model (neglecting the harmonics in the output voltages of VSC) and three phase detailed model of VSC. While the eigenvalue analysis and controller design is based on the d-q model, the transient simulation considers both models.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Thyristor forced commutated AC/DC convertors are useful for improving the power factor and waveform of AC-side line current. These are controlled through pulse-width modulation schemes for best performance. However, the 3-phase versions impose restrictions on the PWM strategies that can be implemented for excellent harmonic rejection. This paper presents new PWM control strategies for the 3-phase converters and compares them along with the conventional 4-pulse PWM strategy for harmonic elimination. Finally, two new PWM strategies are shown to be the best, for which oscillograms are presented from actual implementation.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We report a versatile but easy to make AC mutual inductance bridge. The bridge has been used over the temperature range 4-300 K and with applied magnetic fields up to 7 T. Representative data obtained on various types of magnetic systems are shown.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

ac susceptibility and electrical resistivity studies on polycrystalline Fe80-xNixCr20 (21 \leq x \leq 30) alloys, with x=21, 23, 26, and 30, between 4.2 and 80 K, are reported. A previous dc magnetization study indicated the presence of ferro-spin-glass mixed-phase behavior in x=23 and 26 alloys while the alloys with x=21 and 30 were found to be spin-glass and ferromagnetic, respectively. The present ac susceptibility results support the above picture. In the electrical resistivity study, a low-temperature minimum in the resistivity-temperature curve is observed in all the alloys except the ferromagnetic one.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

An apolar helical decapeptide with different end groups, Boc- or Ac-, crystallizes in a completely parallel fashion for the Boc-analog and in an antiparallel fashion for the Ac-analog. In both crystals, the packing motif consists of rows of parallel molecules. In the Boc-crystals, adjacent rows assemble with the helix axes pointed in the same direction. In the Ac-crystals, adjacent rows assemble with the helix axes pointed in opposite directions. The conformations of the molecules in both crystals are quite similar, predominantly alpha-helical, except for the tryptophanyl side chain where chi 1 congruent to 60 degrees in the Boc- analog and congruent to 180 degrees in the Ac-analog. As a result, there is one lateral hydrogen bond between helices, N(1 epsilon)...O(7), in the Ac-analog. The structures do not provide a ready rationalization of packing preference in terms of side-chain interactions and do not support a major role for helix dipole interactions in determining helix orientation in crystals. The crystal parameters are as follow. Boc-analog: C60H97N11O13.C3H7OH, space group Pl with a = 10.250(3) A, b = 12.451(4) A, c = 15.077(6) A, alpha = 96.55(3) degrees, beta = 92.31(3) degrees, gamma = 106.37(3) degrees, Z = 1, R = 5.5% for 5581 data ([F] greater than 3.0 sigma(F)), resolution 0.89 A. Ac-analog: C57H91N11O12, space group P2(1) with a = 9.965(1) A, b = 19.707(3) A, c = 16.648(3) A, beta = 94.08(1), Z = 2, R = 7.2% for 2530 data ([F] greater than 3.0 sigma(F)), resolution 1.00 A.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The structure of the peptide Boc-Ala-Leu-Ac(7)c-Ala-Leu-Ac(7)c-OMe (Ac(7)c,1-aminocycloheptane-1-carboxylic acid) is described in crystals. The presence of two Ac(7)c residues was expected to stabilize a 3(10)-helical fold. Contrary to expectation the structural analysis revealed an unfolded amino terminus, with Ala(1) adopting an extended beta-conformation (phi = -93degrees,psi = 112degrees). Residues 2-5 form a 3(10)-helix, stabilized by three successive intramolecular hydrogen bonds. Notably, two NH groups Ala(1) and Ac(7)c(3) do not form any hydrogen bonds in the crystal. Peptide assembly appears to be dominated by packing of the cycloheptane rings that stack against one another within the molecule and also throughout the crystal in columns.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Design of high-frequency inductors for purposes like Active Front End (AFE) converter filters involves analytical calculations based on methods like area product approach and accurate graphical methods. Once a core with an area product is selected the subsequent calculations of inductance and peak operating flux requires the estimation of reluctance of the magnetic circuit. This in turn demands an estimate of the fringing that will happen in the air gap of the inductor. In this paper we have looked at analytical methods for evaluating fringing flux and compared it with results from finite element method. Different levels of details of modelling the inductor is first considered for this purpose. The end results are compared with experimental measurements of inductance. It is shown that simple fringing flux model can provide accurate models for the inductor design.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

An algorithm for optimal allocation of reactive power in AC/DC system using FACTs devices, with an objective of improving the voltage profile and also voltage stability of the system has been presented. The technique attempts to utilize fully the reactive power sources in the system to improve the voltage stability and profile as well as meeting the reactive power requirements at the AC-DC terminals to facilitate the smooth operation of DC links. The method involves successive solution of steady-state power flows and optimization of reactive power control variables with Unified Power Flow Controller (UPFC) using linear programming technique. The proposed method has been tested on a real life equivalent 96-bus AC and a two terminal DC system under normal and contingency conditions.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The electrochemical properties of the film-covered anode/solution interface in the magnesium/ manganese dioxide dry cell have been evaluated. The most plausible electrical equivalent circuit description of the Mg/solution interface with the passive film intact, has been identified. These results are based on the analysis of ac impedance and voltage transient measurements made on the dry cell under conditions which cause no damage to the protective passive film on the anode. The study demonstrates the complementary character of impedance and transient measurements when widely different frequency ranges are sampled in each type of investigation. The values and temperature dependence of the anode-film resistance, film capacitance, double-layer capacitance and charge-transfer resistance of the film-covered magnesium/solution interface have been determined. The magnitude of these values and its implications in understanding the important performance aspects of the magnesium/manganese dioxide dry cell are discussed. The study may be extended, in principle, to Li, Al and Ca batteries.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The electrochemical properties of the film-covered anode/solution interface in the magnesium/ manganese dioxide dry cell have been evaluated. The most plausible electrical equivalent circuit description of the Mg/solution interface with the passive film intact, has been identified. These results are based on the analysis of ac impedance and voltage transient measurements made on the dry cell under conditions which cause no damage to the protective passive film on the anode. The study demonstrates the complementary character of impedance and transient measurements when widely different frequency ranges are sampled in each type of investigation. The values and temperature dependence of the anode-film resistance, film capacitance, double-layer capacitance and charge-transfer resistance of the film-covered magnesium/solution interface have been determined. The magnitude of these values and its implications in understanding the important performance aspects of the magnesium/manganese dioxide dry cell are discussed. The study may be extended, in principle, to Li, Al and Ca batteries.