980 resultados para 23-221
Resumo:
Obestatin is a peptide produced in the oxyntic mucosa of the stomach and co-localizes with ghrelin on the periphery of pancreatic islets. Several studies demonstrate that obestatin reduces food and water intake, decreases body weight gain, inhibits gastrointestinal motility, and modulates glucose-induced insulin secretion. In this study we evaluated the acute metabolic effects of human obestatin {1-23} and fragment peptides {1-10} or {11-23} in high-fat fed mice, and then investigated their solution structure by NMR spectroscopy and molecular modelling. Obestatins {1-23} and {11-23} significantly reduced food intake (86% and 90% respectively) and lowered glucose responses to feeding, whilst leaving insulin responses unchanged. No metabolic changes could be detected following the administration of obestatin (1-10). In aqueous solution none of the obestatin peptides possessed secondary structural features. However, in a 2,2,2-trifluoroethanol (TFE-d(3))-H2O solvent mixture, the structure of obestatin {1-23} was characterized by an a-helix followed by a single turn helix conformation between residues Pro(4) and Gln(15) and His(19) and Ala(22) respectively. Obestatin {1-10} showed no structural components whereas {11-23} contained an a-helix between residues Val(14) and Ser(20) in a mixed solvent. These studies are the first to elucidate the structure of human obestatin and provide clear evidence that the observed a-helical structures are critical for in vivo activity. Future structure/function studies may facilitate the design of novel therapeutic agents based on the obestatin peptide structure. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Objective: To investigate the association between angiotensin-converting enzyme inhibitors (ACEIs) and angiotensin receptor blockers (ARBs) and disease progression and survival in cancer patients.
Methods: Using terms for cancer and ACEIs/ARBs, MEDLINE, EMBASE and Web of Science were systematically searched for observational/interventional studies that used clinically relevant outcomes for cancer progression and survival.
Results: Ten studies met the inclusion criteria. Two studies showed a significant improvement in overall survival (OS) with ACEI/ARB use among patients with advanced pancreatic (HR 0.52, 95% CI 0.29–0.88) and non-small cell lung cancer (HR 0.56, 95% CI 0.33–0.95). An improvement in progression-free survival (PFS) was also reported for pancreatic cancer patients (HR 0.58, 95% CI 0.34–0.95) and patients with renal cell carcinoma (HR 0.54, p = 0.02). ACEI/ARB use was protective against breast cancer recurrence (HR 0.60, 95% CI 0.37–0.96), colorectal cancer distant metastasis (OR 0.22, 95% CI 0.08–0.65) and prostate specific antigen (PSA) failure in prostate cancer patients (p = 0.034). One study observed a worse OS (HR 2.01, 95% CI 1.00–4.05) and PFS in ACEI users with multiple myeloma (p = 0.085) while another reported an increased risk of breast cancer recurrence (HR = 1.56, 95% CI 1.02–2.39).
Conclusion: There is some evidence to suggest that ACEI or ARB use may be associated with improved outcomes in cancer patients. Larger, more robust studies are required to explore this relationship further.
Optical source model for the 23.2-23.6 nm radiation from the multielement germanium soft X-ray laser
Resumo:
Distributions of source intensity in two dimensions (designated the source model), averaged over a single laser pulse, based on experimental measurements of spatial coherence, are considered for radiation from the unresolved 23.2/23.6 nm spectral lines from the germanium collisional X-ray laser. The model derives from measurements of the visibility of Young slit interference fringes determined by a method based on the Wiener-Khinchin theorem. Output from amplifiers comprising three and four target elements have similar coherence properties in directions within the horizontal plane corresponding to strong plasma refraction effects and fitting the coherence data shows source dimensions (FWHM) are similar to 26 mu m (horizontal), significantly smaller than expected by direct imaging, and similar to 125 mu m (vertical: equivalent to the height of the driver excitation). (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
The spatial coherence of a nanosecond pulsed germanium collisionally excited x-ray laser is measured experimentally for three target configurations. The diagnostic is based on Young's slit interference fringes with a dispersing element to resolve the 23.2- and 23.6-nm spectral lines. Target configurations include a double-slab target, known as the injector, and geometries in which the injector image is image relayed to seed either an additional single-slab target or a second double-slab target. A special feature of this study is the observation of the change in the apparent source size with angle of refraction across the diverging laser beam. Source sizes derived with a Gaussian source model decrease from 44 mu m for the injector target by a variable factor of as much as 2, according to target configuration, for beams leaving the additional amplifiers after strong refraction in the plasma. (C) 1998 Optical Society of America [S0740-3224(98)00810-8].
Resumo:
The time dependence of the spatial coherence of the combined spectral lines at 23.2 and 23.6 nm from the Ge XXIII collisionally pumped soft-x-ray laser with a double-slab target is examined within a single nanosecond pulse by use of Young's interference fringes and a streak camera. High source intensity is linked with low spatial coherence and vice verse. Calculations of the source intensity, size, and position have also been made; these calculations refer to a single-slab source. Comparison between the observed and calculated intensities, and of the source sizes both calculated and derived from the Young's fringes by interpretation with a Gaussian model of source emission, show good agreement in general trends. (C) 1998 Optical Society of America [S0740-3224(98)01905-5].
Resumo:
We have tested soft X-ray lasing in neon-like germanium with cylindrical targets where wave guiding and plasma confinement may affect lasing. An intense soft X-ray laser beam of 0.05 MW peak power and a narrow beam divergence (8 mrad) was produced at 23.6 nm with a 4 cm long straight cylindrical target of 0.72 mm inner diameter. Bending the cylindrical target to form a toroidal shape increased the lasing intensity by a factor of 3 accompanied with reduction of the beam divergence from 8 to 6 mrad.
Resumo:
Amplification of spontaneous emission at 23.6 nm has been studied in a Ge plasma heated by a 1 TW, 1.06 mum wavelength, laser pulse. The exponent of the axial gain reached 21 in a geometry with Fresnel number less-than-or-equal-to 1. Two plasma columns were produced by irradiation of slab targets up to a combined length of 3.6 cm. A narrow band XUV mirror allowed double pass amplification. Saturation of ASE output at 23.6 nm was observed as a change from exponential to linear growth of the output with plasma length. Further evidence of the effect was provided by a decline in the ratio of the output at 23.6 nm to that at 23.2 nm from approximately 1.6: 1 to approximately 0.5: 1, the latter being the theoretically predicted value for saturated operation. The onset of saturation at gL almost-equal-to 15 is consistent with model calculations. The beam divergence was about 8x diffraction limited with a brightness estimated at almost-equal-to 10(14) W/cm2/ster.
Resumo:
Amplification of spontaneous emission (ASE) at 23.6 nm has been studied in a Ge plasma heated by a 1 TW infrared laser pulse. The exponent of the axial gain reached 21 in a geometry with Fresnel number less-than-or-equal-to 1. Two plasma columns of combined length up to 36 mm were used with an extreme ultraviolet mirror giving double-pass amplification. Saturation of the ASE output was observed. The beam divergence was about 8 x diffraction limited with a brightness estimated at 10(14) W cm-2 sr-1. The feedback from the mirror was significantly reduced probably by radiation damage from the plasma.