407 resultados para 1262
Resumo:
Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Foram estimados na raça Nelore a variabilidade genética e os valores de determinação de paternidade usando-se 11 marcadores microssatélites do painel ISAG/FAO. Estes foram organizados em quatro conjuntos de amplificação para genotipagem semi-automática por fluorescência. Todos os marcadores apresentaram-se altamente polimórficos, com média de 8,2 alelos por loco. A heterozigosidade observada, com média de 0,48, foi menor que a esperada em 10 locos. Foram observadas deficiências de heterozigotos em nove locos, o que resultou no desequilíbrio de Hardy-Weinberg para a população estudada. O conteúdo polimórfico informativo foi superior a 0,5 em 10 locos. O poder de discriminação foi >0,999 e as probabilidades de exclusão de paternidade quando são conhecidos os genótipos de um bezerro, sua mãe e um pai alegado, ou quando um ou outro genótipo parental não está disponível, para o conjunto de marcadores foram >0,999 e >0,989, respectivamente. O conjunto de 11 marcadores constitui método eficiente para a determinação de paternidade na raça Nelore.
Resumo:
Belém, Pára, Brasil, apresenta taxas de mortalidade por câncer de colo uterino bastante elevadas, justificando-se a análise da confiabilidade e validade da causa básica do óbito declarada. Selecionou-se declarações de óbito de residentes de Belém, de 1998-1999, com causa básica de morte neoplasia do colo, corpo e porção não especificada do útero e aquelas que mencionavam essas neoplasias em qualquer linha do atestado, totalizando 188 declarações de óbito. Efetuou-se nova codificação para análise da confiabilidade, aferida pela concordância simples e pela estatística kappa. A causa básica do óbito, após revisão de prontuários médicos e/ou laudos histopatológicos, foi considerada como padrão-ouro para análise da validade de critério, através do valor preditivo positivo. Observou-se concordância simples de 94,0% e kappa de 0,87, sugerindo alta confiabilidade na codificação da causa básica câncer de útero no sistema oficial. Na análise da validade, confirmou-se 120 das 127 originais como colo de útero, três das quatro codificadas como corpo de útero e 18 das 48 classificadas como porção não especificada. Registrou-se aumento de 11,2 % nas neoplasias de colo uterino e redução de 62,5% nos óbitos de porção não especificada do útero.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Endodontically treated teeth have necessary use of intracanal posts. Due to the constant need and search for esthetic materials with properties similar to tooth structure remaining fi berglass posts esthetic came good these shortcomings and are increasingly used as a fi rst option for prosthetic rehabilitation. In this case report is described step by step how to perform the cementation of a nonmetallic post and core construction for making a piece prosthetic onlay in a simplifi ed way, by choosing the self-etching cementation technique.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The paleoclimatic and paleoceanographic history of the Middle and Late Miocene marginal eastern North Pacific as been studied in a north-to-south transect encompassing DSDP Site 173, the Newport Beach surface section, and DSDP Site 470, based on quantitative diatom and planktic foraminiferal analyses. Fourteen cold and 12 warm events that show close agreement with other microfossil studies as well as oxygen isotope records from low-latitude Pacific sites have been identified. Hiatuses are recognized at 7 to 6.5 Ma. 9.8 to 8.5 Ma, and 12 to 11 Ma at the three reference localities, and they correspond to widely recognized deep-sea hiatuses in the World Ocean.
Resumo:
Snake venom proteomes/peptidomes are highly complex and maintenance of their integrity within the gland lumen is crucial for the expression of toxin activities. There has been considerable progress in the field of venom proteomics, however, peptidomics does not progress as fast, because of the lack of comprehensive venom sequence databases for analysis of MS data. Therefore, in many cases venom peptides have to be sequenced manually by MS/MS analysis or Edman degradation. This is critical for rare snake species, as is the case of Bothrops cotiara (BC) and B. fonsecai (BF), which are regarded as near threatened with extinction. In this study we conducted a comprehensive analysis of the venom peptidomes of BC, BF, and B. jararaca (BJ) using a combination of solid-phase extraction and reversed-phase HPLC to fractionate the peptides, followed by nano-liquid chromatography-tandem MS (LC-MS/MS) or direct infusion electrospray ionization-(ESI)-MS/MS or MALDI-MS/MS analyses. We detected marked differences in the venom peptidomes and identified peptides ranging from 7 to 39 residues in length by de novo sequencing. Forty-four unique sequences were manually identified, out of which 30 are new peptides, including 17 bradykinin-potentiating peptides, three poly-histidine-poly-glycine peptides and interestingly, 10 L-amino acid oxidase fragments. Some of the new bradykinin-potentiating peptides display significant bradykinin potentiating activity. Automated database search revealed fragments from several toxins in the peptidomes, mainly from L-amino acid oxidase, and allowed the determination of the peptide bond specificity of proteinases and amino acid occurrences for the P4-P4' sites. We also demonstrate that the venom lyophilization/resolubilization process greatly increases the complexity of the peptidome because of the imbalance caused to the venom proteome and the consequent activity of proteinases on venom components. The use of proteinase inhibitors clearly showed different outcomes in the peptidome characterization and suggested that degradomic-peptidomic analysis of snake venoms is highly sensitive to the conditions of sampling procedures. Molecular & Cellular Proteomics 11: 10.1074/mcp.M112.019331, 1245-1262, 2012.