988 resultados para welding procedure test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Padding materials are commonly used in fruit packing lines with the objective of diminishing impact damage in postharvest handling. Two sensors, instrumented sphere IS 100 and impact tester, have been compared to analyze the performance of six different padding materials used in Spanish fruit packing lines. Padding materials tested have been classified according to their capability to decrease impact intensities inflicted to fruit in packing lines. A procedure to test padding materials has been developed for "Golden" apples. Its basis is a logistic regression to predict bruise probability in fruit. The model combines two kinds of parameters: padding material parameters measured with IS, and fruit properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the consolidation of the new solid state lighting LEOs devices, te5t1n9 the compliance 01 lamps based on this technology lor Solar Home Systems (SHS) have been analyzed. The definition of the laboratory procedures to be used with final products 15 a necessary step in arder to be able to assure the quality of the lamps prior to be installed [1]. As well as with CFL technology. particular attention has been given to simplicity and technical affordability in arder to facilitate the implementation of the test with basie and simple laboratory too15 even on the same SHS electrification program locations. The block of test procedures has been applied to a set of 14 low-cost lamps. They apply to lamp resistance, reliability and performance under normal, extreme and abnormal operating conditions as a simple but complete quality meter tool 01 any LEO bulb.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The definition of technical specifications and the corresponding laboratory procedures are necessary steps in order to assure the quality of the devices prior to be installed in Solar Home Systems (SHS). To clarify and unify criteria a European project supported the development of the Universal Technical Standard for Solar Home Systems (UTSfSHS). Its principles were to generate simple and affordable technical requirements to be optimized in order to facilitate the implementation of tests with basic and simple laboratory tools even on the same SHS electrification program countries. These requirements cover the main aspects of this type of installations and its lighting chapter was developed based on the most used technology at that time: fluorescent tubes and CFLs. However, with the consolidation of the new LED solid state lighting devices, particular attention is being given to this matter and new procedures are required. In this work we develop a complete set of technical specifications and test procedures that have been designed within the frame of the UTSfSHS, based on an intense review of the scientific and technical publications related to LED lighting and their practical application. They apply to lamp reliability, performance and safety under normal, extreme and abnormal operating conditions as a simple but complete quality meter tool for any LED bulb.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plant surfaces have been found to have a major chemical and physical heterogeneity and play a key protecting role against multiple stress factors. During the last decade, there is a raising interest in examining plant surface properties for the development of biomimetic materials. Contact angle measurement of different liquids is a common tool for characterizing synthetic materials, which is just beginning to be applied to plant surfaces. However, some studies performed with polymers and other materials showed that for the same surface, different surface free energy values may be obtained depending on the number and nature of the test liquids analyzed, materials' properties, and surface free energy calculation methods employed. For 3 rough and 3 rather smooth plant materials, we calculated their surface free energy using 2 or 3 test liquids and 3 different calculation methods. Regardless of the degree of surface roughness, the methods based on 2 test liquids often led to the under- or over-estimation of surface free energies as compared to the results derived from the 3-Liquids method. Given the major chemical and structural diversity of plant surfaces, it is concluded that 3 different liquids must be considered for characterizing materials of unknown physico-chemical properties, which may significantly differ in terms of polar and dispersive interactions. Since there are just few surface free energy data of plant surfaces with the aim of standardizing the calculation procedure and interpretation of the results among for instance, different species, organs, or phenological states, we suggest the use of 3 liquids and the mean surface tension values provided in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the change-point problem for a general parametric, univariate or multivariate family of distributions. An information theoretic procedure is developed which is based on general divergence measures for testing the hypothesis of the existence of a change. For comparing the exact sizes of the new test-statistic using the criterion proposed in Dale (J R Stat Soc B 48–59, 1986), a simulation study is performed for the special case of exponentially distributed random variables. A complete study of powers of the test-statistics and their corresponding relative local efficiencies, is also considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present a simple algorithm for assessing the validity of the RVoG model for PolInSAR-based inversion techniques. This approach makes use of two important features characterizing a homogeneous random volume over a ground surface, i.e., the independence on polarization states of wave propagation through the volume and the structure of the polarimetric interferometric coherency matrix. These two features have led to two different methods proposed in the literature for retrieving the topographic phase within natural covers, i.e., the well-known line fitting procedure and the observation of the (1, 2) element of the polarimetric interferometric coherency matrix. We show that differences between outputs from both approaches can be interpreted in terms of the PolInSAR modeling based on the Freeman-Durden concept, and this leads to the definition of a RVoG/non-RVoG test. The algorithm is tested with both indoor and airborne data over agricultural and tropical forest areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two different slug test field methods are conducted in wells completed in a Puget Lowland aquifer and are examined for systematic error resulting from water column displacement techniques. Slug tests using the standard slug rod and the pneumatic method were repeated on the same wells and hydraulic conductivity estimates were calculated according to Bouwer & Rice and Hvorslev before using a non-parametric statistical test for analysis. Practical considerations of performing the tests in real life settings are also considered in the method comparison. Statistical analysis indicates that the slug rod method results in up to 90% larger hydraulic conductivity values than the pneumatic method, with at least a 95% certainty that the error is method related. This confirms the existence of a slug-rod bias in a real world scenario which has previously been demonstrated by others in synthetic aquifers. In addition to more accurate values, the pneumatic method requires less field labor, less decontamination, and provides the ability to control the magnitudes of the initial displacement, making it the superior slug test procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To account for the preponderance of zero counts and simultaneous correlation of observations, a class of zero-inflated Poisson mixed regression models is applicable for accommodating the within-cluster dependence. In this paper, a score test for zero-inflation is developed for assessing correlated count data with excess zeros. The sampling distribution and the power of the test statistic are evaluated by simulation studies. The results show that the test statistic performs satisfactorily under a wide range of conditions. The test procedure is further illustrated using a data set on recurrent urinary tract infections. Copyright (c) 2005 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of variation in weld crack susceptibility caused by small variations in alloy and impurity elements for the 70-30 cupro-nickel alloy has been investigated. Both wrought and cast versions of the alloy have been studied, the main techniques employed being the Varestraint test and weld thermal simulation. In the wrought alloys, cracking has been found to occur mainly in the weld metal, whilst in the cast alloys cracking is extensive in both weld metal and heat affected zone. The previously reported effects of certain impurities (P,S,Si) in increasing cracking have been confirmed, and it has also been shown that Ti and Zr may both have a crack promoting effect at levels commonly found in cupro-nickels, whilst C can interact with several of the other elements investigated to produce a beneficial effect. The testing carried out using the weld thermal simulator has shown that a relationship does exist between hot ductility and weld cracking. In particular, the absence of the peak in ductility in the range 1100°C-900°C on cooling from a temperature near to the solidus is indicative of a highly crack susceptible alloy. Principal practical implications of the investigation concern the relationship of weld metal cracking to alloy composition, especially the level of certain impurities. It would appear that the upper limits permitted by the alloy specifications are unrealistically high. The introduction of lower impurity limits would alleviate the current problems of variability in resistance to cracking during welding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Product reliability and its environmental performance have become critical elements within a product's specification and design. To obtain a high level of confidence in the reliability of the design it is customary to test the design under realistic conditions in a laboratory. The objective of the work is to examine the feasibility of designing mechanical test rigs which exhibit prescribed dynamical characteristics. The design is then attached to the rig and excitation is applied to the rig, which then transmits representative vibration levels into the product. The philosophical considerations made at the outset of the project are discussed as they form the basis for the resulting design methodologies. It is attempted to directly identify the parameters of a test rig from the spatial model derived during the system identification process. It is shown to be impossible to identify a feasible test rig design using this technique. A finite dimensional optimal design methodology is developed which identifies the parameters of a discrete spring/mass system which is dynamically similar to a point coordinate on a continuous structure. This design methodology is incorporated within another procedure which derives a structure comprising a continuous element and a discrete system. This methodology is used to obtain point coordinate similarity for two planes of motion, which is validated by experimental tests. A limitation of this approach is that it is impossible to achieve multi-coordinate similarity due to an interaction of the discrete system and the continuous element at points away from the coordinate of interest. During the work the importance of the continuous element is highlighted and a design methodology is developed for continuous structures. The design methodology is based upon distributed parameter optimal design techniques and allows an initial poor design estimate to be moved in a feasible direction towards an acceptable design solution. Cumulative damage theory is used to provide a quantitative method of assessing the quality of dynamic similarity. It is shown that the combination of modal analysis techniques and cumulative damage theory provides a feasible design synthesis methodology for representative test rigs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A description of the background to testing friction materials for automotive brakes explains the need for a rapid, inexpensive means of assessing their behaviour in a way which is both accurate and meaningful. Various methods of controlling inertia dynamometers to simulate road vehicles are rejected in favour of programming by means of a commercially available XY plotter. Investigation of brake service conditions is used to set up test schedules, and a dynamometer programming unit built to enable service conditions on vehicles to be simulated on a full scale dynamometer. A technique is developed by which accelerated testing can be achieved without operating under overload conditions, saving time and cost without sacrificing validity. The development of programming by XY plotter is described, with a method of operating one XY plotter to programme the machine, monitor its own behaviour, and plot its own results in logical sequence. Commissioning trials are described and the generation of reproducible results in frictional behaviour and material durability is discussed. Teclmiques are developed to cross check the operation of the machine in retrospect, and retrospectively correct results in the event of malfunctions. Sensitivity errors in the measuring circuits are displayed between calibrations, whilst leaving the recorded results almost unaffected by error. Typical results of brake lining tests are used to demonstrate the range of performance parameters which can be studied by use of the machine. Successful test investigations completed on the machine are reported, including comments on behaviour of cast iron drums and discs. The machine shows that materials can repeat their complex friction/ temperature/speed/pressure relationships at a reproducibility of the order of +-0.003u and +~ 0.0002 in. thickness loss during wear tests. Discussion of practical and academic implications completes the report with recommendations for further work in both fields.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The inverse problem of determining a spacewise dependent heat source, together with the initial temperature for the parabolic heat equation, using the usual conditions of the direct problem and information from two supplementary temperature measurements at different instants of time is studied. These spacewise dependent temperature measurements ensure that this inverse problem has a unique solution, despite the solution being unstable, hence the problem is ill-posed. We propose an iterative algorithm for the stable reconstruction of both the initial data and the source based on a sequence of well-posed direct problems for the parabolic heat equation, which are solved at each iteration step using the boundary element method. The instability is overcome by stopping the iterations at the first iteration for which the discrepancy principle is satisfied. Numerical results are presented for a typical benchmark test example, which has the input measured data perturbed by increasing amounts of random noise. The numerical results show that the proposed procedure gives accurate numerical approximations in relatively few iterations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report an extension of the procedure devised by Weinstein and Shanks (Memory & Cognition 36:1415-1428, 2008) to study false recognition and priming of pictures. Participants viewed scenes with multiple embedded objects (seen items), then studied the names of these objects and the names of other objects (read items). Finally, participants completed a combined direct (recognition) and indirect (identification) memory test that included seen items, read items, and new items. In the direct test, participants recognized pictures of seen and read items more often than new pictures. In the indirect test, participants' speed at identifying those same pictures was improved for pictures that they had actually studied, and also for falsely recognized pictures whose names they had read. These data provide new evidence that a false-memory induction procedure can elicit memory-like representations that are difficult to distinguish from "true" memories of studied pictures. © 2012 Psychonomic Society, Inc.