In Russian there are more than twenty thousand primary substations 35/110 kV and 10/110 kV. According to the Government Plan of Power Industry Development until 2020 year more than hundred new substations will e installed every year and even more renewed. The goal of this Thesis is to find out in this business environment what are the technology opportunities of prefabricated substation modules in new substation or in modernization of old substations in Russia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulsed dielectric barrier discharge (PDBD) and pulsed corona discharge (PCD) were compared for their efficiency to degrade phenol in water solution. Results show that PCD has higher efficiency than PDBD to degrade phenol. When initial pH of water solution was elevated, phenol degradation in the PCD reactor was significantly enhanced, although no considerable effect was seen in the PDBD reactor. The PCD reactor was also able to degrade lignin significantly, both in synthetically prepared solution and in pulp and paper mill wastewater. Water temperature did not affect phenol degradation; however, lignin was better oxidized at lower temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work aims to analyze the possibilities of utilizing old crane driving AC induction motors in modern pulse-width-modulated variable frequency drives. Bearing currents and voltage stresses are the two main problems associated with modern IGBT inverters, and they may cause premature failure of an old induction motor. The origins of these two problems are studied. An analysis of the mechanism of bearing failure is proposed. Certain types of bearing currents are considered in detail. The most effective and economical means are chosen for bearing currents mitigation. Transient phenomena of cables and mechanism of over voltages occurring at motor terminals are studied in the work. The weakest places of the stator winding insulation system are shown and recommendations are given considering the mitigation of voltage stresses. Only the most appropriate and cost effective preventative methods are chosen for old motor drives. Rewinding of old motors is also considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nykyiset IGB-transistorit voivat tuottaa jopa 30 ns nousureunoja, jolloin jänniterasitus jakautuu hyvin epätasaisesti käämien ja kierrosten kesken. Tämä ja eristeissä esiintyvät ilmataskut asettavat käämikierrosten välisten eristeiden jännitekestävyyden koetukselle, ja aiheuttavat riskin osittaispurkaukselle. Urassa hajavuon epätasaisen jakauman aiheuttama virranahto on yleensä ollut esillä suurissa koneissa, jotka toimivat 50 Hz:llä. Nykyään taajuusmuuttajien soveltaminen on mahdollistanut nimellistaajuudeltaan satojen hertsien suurnopeuskoneiden käämitysten valmistamisen pyörölangasta, jolloin virranahto tulee merkittäväksi, koska kierroksia on muutama urassa. Työssä mitattiin jännitteen jakautumista 3.5 MW:n tuulivoimageneraattorin segmentissä käyttäen käämitysten syöttöön erilaisia jännitteen nousuaikoja, ja pyrittiin arvioimaan onko kyseinen kone vaarassa kokea osittaispurkauksia elinikänsä aikana. Työssä on myös käsitelty virranahtoa käyttäen finiittielementtimenetelmää simuloimaan ja vertaamaan erilaisia tilanteita käämitystavoissa pyörölankakoneessa. Tämä on myös osittain sovellettavissa muotokuparilla käämittyihin koneisiin. Käämivyyhdin vyyhdenpään alueella tehdyn johdinnipun 180 asteen kierron vaikutusta simuloitiin ja sen aiheuttamaa parannusta varmennettiin käytännön mittauksilla.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under pathological conditions, microglia, the resident CNS immune cells, become reactive and release pro-inflammatory cytokines and neurotoxic factors. We investigated whether this phenotypic switch includes changes in the expression of the L-type voltage-gated calcium channel (VGCC) in a rat model of N-methyl-d-aspartate-induced hippocampal neurodegeneration. Double immunohistochemistry and confocal microscopy evidenced that activated microglia express the L-type VGCC. We then analyzed whether BV2 microglia express functional L-type VGCC, and investigated the latter's role in microglial cytokine release and phagocytic capacity. Activated BV2 microglia express the CaV1.2 and CaV1.3 subunits of the L-type VGCC determined by reverse transcription-polymerase chain reaction, Western blot and immunocytochemistry. Depolarization with KCl induced a Ca2+ entry facilitated by Bay k8644 and partially blocked with nifedipine, which also reduced TNF-α and NO release by 40%. However, no nifedipine effect on BV2 microglia viability or phagocytic capacity was observed. Our results suggest that in CNS inflammatory processes, the L-type VGCC plays a specific role in the control of microglial secretory activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advancements in power electronic semiconductor switching devices have lead to significantly faster switching times. In motor and generator applications, the fast switching times of pulse width modulated (PWM) inverters lead to overvoltages caused by voltage reflections with shorter and shorter cables. These excessive overvoltages may lead to a failure of the electrical machine in a matter of months. In this thesis, the causes behind the overvoltage phenomenon as well as its different mitigation techniques are studied. The most suitable techniques for mitigating the overvoltage phenomenon in wind power generator applications are chosen based on both simulations and actual measurements performed on a prototype. An RC filter at the terminals of the electrical machine and an inverter output filter designed to reduce the rise and fall times of voltage pulses are presented as a solution to the overvoltage problem. The performance and losses of both filter types are analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distribution companies are facing numerous challenges in the near future. Regulation defines correlation between power quality and revenue cap. Companies have to take measures for reliability increase to successfully compete in modern conditions. Most of the failures seen by customers originate in medium voltage networks. Implementation of network automation is the very effective measure to reduce duration and number of outages, and consequently, outage costs. Topic of this diploma work is study of automation investments effect on outage costs and other reliability indices. Calculation model have been made to perform needed reliability calculations. Theoretical study of different automation scenarios has been done. Case feeder from actual distribution company has been studied and various renovation plans have been suggested. Network automation proved to be effective measure for increasing medium voltage network reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power transformer is the most expensive equipment on a substation. It is always necessary to get needed benefit with the lowest expenses. Producing of power transformers with reduced insulation strength is one of the possible ways to reduce expenses. Exploitation of such transformers was begun in the end of 70-th in the last century. Protection from overvoltages was done with valve-type magnetic combined surge arresters with increased blanking voltage during switching overvoltages. Nowadays there is the necessity of replacement of those devices. That’s why modernized nonlinear surge arrester was invented. This master’s thesis is focused on the use research of that modernized device in comparison with usual nonlinear surge arresters. The goal is to show the lightning overvoltages level using different types of nonlinear surge arresters and then calculations of the lightning protection reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical analysis of Low Voltage Direct Current (LVDC) distribution systems shows that in LVDC transmission the customer voltage quality is higher. One of the problems in LVDC distribution networks that converters both ends of the DC line are required. Because of the converters produce not pure DC voltage, but some fluctuations as well, the huge electrolytic capacitors are required to reduce voltage distortions in the DC-side. This thesis master’s thesis is focused on calculating required DC-link capacitance for LVDC transmission and estimation of the influence of different parameters on the voltage quality. The goal is to investigate the methods of the DC-link capacitance estimation and location in the transmission line.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron transport in a self-consistent potential along a ballistic two-terminal conductor has been investigated. We have derived general formulas which describe the nonlinear current-voltage characteristics, differential conductance, and low-frequency current and voltage noise assuming an arbitrary distribution function and correlation properties of injected electrons. The analytical results have been obtained for a wide range of biases: from equilibrium to high values beyond the linear-response regime. The particular case of a three-dimensional Fermi-Dirac injection has been analyzed. We show that the Coulomb correlations are manifested in the negative excess voltage noise, i.e., the voltage fluctuations under high-field transport conditions can be less than in equilibrium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis is to investigate the thermal loading of medium voltage three-level NPC inverter’s semiconductor IGCT switches in different operation points. The objective is to reach both a fairly accurate off-line simulation program and also so simple a simulation model that its implementation into an embedded system could be reasonable in practice and a real time use should become feasible. Active loading limitation of the inverter can be realized with a thermal model which is practical in a real time use. Determining of the component heating has been divided into two parts; defining of component losses and establishing the structure of a thermal network. Basics of both parts are clarified. The simulation environment is Matlab-Simulink. Two different models are constructed – a more accurate one and a simplified one. Potential simplifications are clarified with the help of the first one. Simplifications are included in the latter model and the functionalities of both models are compared. When increasing the calculation time step a decreased number of considered components and time constants of the thermal network can be used in the simplified model. Heating of a switching component is dependent on its topological position and inverter’s operation point. The output frequency of the converter defines mainly which one of the switching components is – because of its losses and heating – the performance limiting component of the converter. Comparison of results given by different thermal models demonstrates that with larger time steps, describing of fast occurring switching losses becomes difficult. Generally articles and papers dealing with this subject are written for two-level inverters. Also inverters which apply direct torque control (DTC) are investigated rarely from the heating point of view. Hence, this thesis completes the former material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for electricity is constantly growing in contemporary world and, in the same time, quality and reliability requirements are becoming more rigid. In addition, renewable sources of energy have been widely introduced for power generation, and they create specific challenges for the network. Consequently, new solution for distribution system is required, and Low Voltage Direct Current (LVDC) system is the proposed one. This thesis focuses on the investigation of specific cable features for low voltage direct current (LVDC) distribution system. The LVDC system is public ±750 VDC distribution system, which is currently being developed at Lappeen-ranta University of Technology. The aspects, considered in the thesis, are reliable and economic power transmission in distribution networks and possible power line communication in the LVDC cable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.