982 resultados para volatile organic content
Resumo:
This work deals with the numerical simulation of air stripping process for the pre-treatment of groundwater used in human consumption. The model established in steady state presents an exponential solution that is used, together with the Tau Method, to get a spectral approach of the solution of the system of partial differential equations associated to the model in transient state.
Resumo:
A prática de exercício físico é considerado condição essencial para a manutenção de uma boa saúde. A faixa etária de frequentadores de ginásios inclui utentes desde os 8 aos 80 anos, incluindo assim os grupos mais sensíveis à poluição do ar interior. Embora exista legislação específica para ginásios, nomeadamente para as condições de implementação, a mesma é reduzida e não contempla a qualidade do ar interior (QAI). O objetivo geral deste estudo consistiu na avaliação da QAI de quatro ginásios existentes na área metropolitana do Porto. O período de amostragem realizou-se entre 2 de Maio e 20 de Junho 2014 e, após a caracterização dos ginásios, foram monitorizados os seguintes parâmetros: partículas ultrafinas (< 100 nm), matéria particulada suspensa no ar de frações PM1, PM2,5, PM4 e PM10, dióxido de carbono, monóxido de carbono, ozono, compostos orgânicos voláteis, formaldeído, temperatura ambiente e humidade relativa durante 24 h/dia em salas com diferentes actividades (sala de musculação e cardiofitness e sala de aulas de grupo). Os resultados da avaliação dos parâmetros físicos e químicos foram comparados com os limiares de proteção e margem de tolerância do Decreto-Lei nº 118/2013 de 20 de Agosto, a Portaria nº 353-A/2013 de 4 de Dezembro e o Diploma que regula a construção, instalação e funcionamento dos ginásios. Os poluentes com maiores níveis de excedência são o dióxido de carbono, compostos orgânicos voláteis e as partículas PM2,5. As excedências devem-se essencialmente à sobrelotação das salas, excesso de atividade física e ventilação insuficiente. A localização da instalação dos ginásios é também um fator de extrema importância, sendo recomendado que este se situe em local pouco influenciado pelo tráfego automóvel, assim como, afastado de locais de possível interferência devido às atividades presentes, como é o caso da restauração existente em centros comerciais.
Resumo:
A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.
Resumo:
RESUMO Tratando-se a asma de uma doença respiratória, desde há várias décadas que tem sido abordada a hipótese de que factores ambientais, nomeadamente os relacionados com a qualidade do ar inalado, possam contribuir para o seu agravamento. Para além dos aeroalergenos, outros factores ambientais como a poluição atmosférica estarão associados às doenças respiratórias. O ar respirado contém uma variedade de poluentes atmosféricos, provenientes quer de fontes naturais quer de origem antropogénica, nomeadamente de actividades industriais, domésticas ou das emissões de veículos. Estes poluentes, tradicionalmente considerados como um problema de foro ambiental, têm sido cada vez mais encarados como um problema de saúde pública. Também a qualidade do ar interior, tem sido associada a queixas respiratórias, não só em termos ocupacionais mas também em exposições domésticas. Dentro dos principais poluentes, encontramos a matéria particulada (como as PM10), o O3, NO2, e os compostos orgânicos voláteis (COVs). Se é verdade que os três primeiros têm como principais fontes de exposição a combustão fóssil associada aos veículos automóveis, já os COVs (como o benzeno, tolueno, xileno, etilbenzeno e formaldeído) são poluentes mais característicos do ar interior. Os mecanismos fisiopatológicos subjacentes à agressão dos poluentes do ar não se encontram convenientemente esclarecidos. Pensa-se que após a sua inalação, induzam um grau crescente de stress oxidativo que será responsável pelo desenvolvimento da inflamação das vias aéreas. A progressão do stress oxidativo e da inflamação, associarse- ão posteriormente a lesão local (pulmonar) e sistémica. Neste trabalho pretendeu-se avaliar os efeitos da exposição individual a diversos poluentes, do ar exterior e interior, sobre as vias aéreas, recorrendo a parâmetros funcionais, inflamatórios e do estudo do stress oxidativo. Neste sentido, desenvolveu-se um estudo de painel na cidade de Viseu, em que foram acompanhadas durante 18 meses, 51 crianças com história de sibilância, identificadas pelo questionário do estudo ISAAC. As crianças foram avaliadas em quatro Visitas (quatro medidas repetidas), através de diversos exames, que incluíram execução de espirometria com broncodilatação, medição ambulatória do PEF, medição de FENO e estudo do pH no condensado brônquico do ar exalado. O estudo dos 8-isoprostanos no condensado brônquico foi efectuado somente em duas Visitas, e o do doseamento de malonaldeído urinário somente na última Visita. Para além da avaliação do grau de infestação de ácaros do pó do colchão, para cada criança foi calculado o valor de exposição individual a PM10, O3, NO2, benzeno, tolueno, xileno, etilbenzeno e formaldeído, através de uma complexa metodologia que envolveu técnicas de modelação associadas a medições directas do ar interior (na casa e escola da criança) e do ar exterior. Para a análise de dados foram utilizadas equações de estimação generalizadas com uma matriz de correlação de trabalho uniforme, com excepção do estudo das associações entre poluentes, 8-isoprostanos e malonaldeído. Verificou-se na análise multivariável a existência de uma associação entre o agravamento dos parâmetros espirométricos e a exposição aumentada a PM10, NO2, benzeno, tolueno e etilbenzeno. Foram também encontradas associações entre diminuição do pH do EBC e exposição crescente a PM10, NO2, benzeno e etilbenzeno e associações entre valores aumentados de FENO e exposição a etilbenzeno e tolueno. O benzeno, o tolueno e o etilbenzeno foram associados com maior recurso a broncodilatador nos 6 meses anteriores à Visita e o tolueno com deslocações ao serviço de urgência. Os resultados dos modelos de regressão que incluíram o efeito do poluente ajustado para o grau de infestação de ácaros do pó foram, de uma forma geral, idênticos ao da análise multivariável anterior, com excepção das associações para com o FENO. Nos modelos de exposição com dois poluentes, com o FEV1 como variável resposta, somente o benzeno persistiu com significado estatístico. No modelo com dois poluentes tendo o pH do EBC como variável resposta, somente persistiram as PM10. Os 8-isoprostanos correlacionaram-se com alguns COVs, designadamente etilbenzeno, xileno, tolueno e benzeno. Os valores de malonaldeído urinário não se correlacionaram com os valores de poluentes. Verificou-se no entanto que de uma forma geral, e em particular mais uma vez para os COVs, as crianças mais expostas a poluentes, apresentaram valores superiores de malonaldeído na urina. Verificou-se que os poluentes do ar em geral, e os COVs em particular, se associaram com uma deterioração das vias aéreas. A exposição crescente a poluentes associou-se não só com obstrução brônquica, mas também com FENO aumentado e maior acidez das vias aéreas. A exposição crescente a COVs correlacionou-se com um maior stress oxidativo das vias aéreas (medido pelos 8-isoprostanos). As crianças com exposição superior a COVs apresentaram maiores valores de malonaldeído urinário. Este trabalho sugere uma associação entre exposição a poluentes, inflamação das vias aéreas e stress oxidativo. Vem reforçar o interesse dos poluentes do ar, nomeadamente os associados a ambientes interiores, frequentemente esquecidos e que poderão ser explicativos do agravamento duma criança com sibilância.-----------ABSTRACT: Asthma is a chronic respiratory disease that could be influenced by environmental factors, as allergens and air pollutants. The air breathed contains a diversity of air pollutants, both from natural or anthropogenic sources. Atmospheric pollution, traditionally considered an environmental problem, is nowadays looked as an important public health problem. Indoor air pollutants are also related with respiratory diseases, not only in terms of occupational exposures but also in domestic activities. Particulate matter (such as PM10), O3, NO2 and volatile organic compounds (VOCs) are the main air pollutants. The main source for PM10, O3, NO2 exposure is traffic exhaust while for VOCs (such as benzene, toluene, xylene, ethylbenzene and phormaldehyde) the main sources for exposure are located in indoor environments. The pathophysiologic mechanisms underlying the aggression of air pollutants are not properly understood. It is thought that after inhalation, air pollutants could induce oxidative stress, which would be responsible for airways inflammation. The progression of oxidative stress and airways inflammation, would contribute for the local and systemic effects of the air pollutants. The present study aimed to evaluate the effects of individual exposure to various pollutants over the airways, through lung function tests, inflammatory and oxidative stress biomarkers. In this sense, we developed a panel study in the city of Viseu, that included 51 children with a history of wheezing. Those children that were identified by the ISAAC questionnaire, were followed for 18 months. Children were assessed four times (four repeated measures) through the following tests: spirometry with bronchodilation test, PEF study, FENO evaluation and exhaled breath condensate pH measurement. 8-isoprostane in the exhaled breath condensate were also measured but only in two visits. Urinary malonaldehyde measurement was performed only in the last visit. Besides the assessment of the house dust mite infestation, we calculated for each child the value of individual exposure to a wide range of pollutants: PM10, O3, NO2, benzene, toluene, xylene, ethyl benzene and formaldehyde. This strategy used a complex methodology that included air pollution modelling techniques and direct measurements indoors (homes and schools) and outdoors. Generalized estimating equations with an exchangeable working correlation matrix were used for the analysis of the data. Exceptions were for the study of associations between air pollutants, malonaldehyde and 8-isoprostanes. In the multivariate analysis we found an association between worsening of spirometric outcomes and increased exposure to PM10, NO2, benzene, toluene and ethylbenzene. In the multivariate analysis we found also negative associations between EBC pH and exposure to PM10, NO2, benzene, ethylbenzene and positive associations between FENO and exposure to ethylbenzene and toluene. Benzene, toluene and ethylbenzene were associated with increased use of bronchodilator in the 6 months prior to the visit and toluene with emergency department visits. Results of the regression models that included also the effect of the pollutant adjusted for the degree of infestation to house dust mites, were identical to the previous models. Exceptions were for FENO associations. In the two-pollutant models, with the FEV1 as dependent variable, only benzene persisted with statistical significance. In the two pollutant model with pH of EBC as dependent variable, only PM10 persisted. 8-isoprostanes were well correlated with some VOCs, namely with ethylbenzene, xylene, toluene and benzene. Urinary malonaldehyde did not present any correlation with air pollutants exposure. However, those children more exposed to air pollutants (namely to VOCs), presented higher values of malonaldehyde. It was found that air pollutants in general, and namely VOCs, were associated with deterioration of the airways. The increased exposure to air pollutants was associated not only with airways obstruction, but also with increased FENO and higher acidity of the airways. The increased exposure to VOCs was correlated with increased airways oxidative stress (measured by 8-isoprostane). Children with higher levels of exposure to VOCs had higher values of urinary malonaldehyde. This study suggests a relation between air pollution, airways inflammation and oxidative stress. It suggests also that attention should be dedicated to air quality as air pollutants could cause airways deterioration.
Resumo:
O presente trabalho teve como objetivo a realização de um plano de gestão de solventes e sua análise para propor melhorias no cumprimento dos valores legalmente impostos. Foram realizados dois planos distintos, um referente à indústria de revestimento e outro à indústria de formulação de tintas. As abordagens na realização e análise de resolução de problemas são distintas, uma vez que os limites legais são diferentes em ambos os casos. Os componentes que apresentam uma maior expressão face ao plano de gestão de solventes são os compostos orgânicos voláteis (COVs), e é a partir destes componentes que se efetuou toda a análise. Inicialmente foi necessário conhecer todo o funcionamento de cada empresa, os procedimentos adotados, a utilização dos produtos e as técnicas operacionais. Determinaram-se os pontos críticos na avaliação dos problemas que se verificaram nos planos de gestão de solventes e analisaram-se as possibilidades técnicas e tecnológicas passiveis de utilização para a resolução ou minimização desses problemas principalmente na empresa A que excede o limite legalmente imposto. As possibilidades centram-se a nível tecnológico de equipamentos e em produtos utilizados em ambos os casos.
Resumo:
Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods --- study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A children’s respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and children’s health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil de Gestão de Sistemas Ambientais
Resumo:
International Journal of Architectural Heritage, 8: 185–212, 2014
Resumo:
Ion Mobility Spectrometry coupled with Multi Capillary Columns (MCC -IMS) is a fast analytical technique working at atmospheric pressure with high sensitivity and selectivity making it suitable for the analysis of complex biological matrices. MCC-IMS analysis generates its information through a 3D spectrum with peaks, corresponding to each of the substances detected, providing quantitative and qualitative information. Sometimes peaks of different substances overlap, making the quantification of substances present in the biological matrices a difficult process. In the present work we use peaks of isoprene and acetone as a model for this problem. These two volatile organic compounds (VOCs) that when detected by MCC-IMS produce two overlapping peaks. In this work it’s proposed an algorithm to identify and quantify these two peaks. This algorithm uses image processing techniques to treat the spectra and to detect the position of the peaks, and then fits the data to a custom model in order to separate the peaks. Once the peaks are separated it calculates the contribution of each peak to the data.
Resumo:
Dissertação de mestrado em Propriedades e Tecnologias de Polímeros
Resumo:
Anaerobic digestion (AD) is a well-established technology used for the treatment of wastes and wastewaters with high organic content. During AD organic matter is converted stepwise to methane-containing biogasa renewable energy carrier. Methane production occurs in the last AD step and relies on methanogens, which are rather sensitive to some contaminants commonly found in wastewaters (e.g. heavy metals), or easily outcompeted by other groups of microorganisms (e.g. sulphate reducing bacteria, SRB). This review gives an overview of previous research and pilot-scale studies that shed some light on the effects of sulphate and heavy metals on methanogenesis. Despite the numerous studies on this subject, comparison is not always possible due to differences in the experimental conditions used and parameters explained. An overview of the possible benefits of methanogens and SRB co-habitation is also covered. Small amounts of sulphide produced by SRB can precipitate with metals, neutralising the negative effects of sulphide accumulation and free heavy metals on methanogenesis. Knowledge on how to untangle and balance sulphate reduction and methanogenesis is crucial to take advantage of the potential for the utilisation of biogenic sulphide as a metal detoxification agent with minimal loss in methane production in anaerobic digesters.
Resumo:
Isoprene emission from plants accounts for about one third of annual global volatile organic compound emissions. The largest source of isoprene for the global atmosphere is the Amazon Basin. This study aimed to identify and quantify the isoprene emission and photosynthesis at different levels of light intensity and leaf temperature, in three phenological phases (young mature leaf, old mature leaf and senescent leaf) of Eschweilera coriacea (Matamatá verdadeira), the species with the widest distribution in the central Amazon. In situ photosynthesis and isoprene emission measurements showed that young mature leaf had the highest rates at all light intensities and leaf temperatures. Additionally, it was observed that isoprene emission capacity (Es) changed considerably over different leaf ages. This suggests that aging leads to a reduction of both leaf photosynthetic activity and isoprene production and emission. The algorithm of Guenther et al. (1999) provided good fits to the data when incident light was varied, however differences among E S of all leaf ages influenced on quantic yield predicted by model. When leaf temperature was varied, algorithm prediction was not satisfactory for temperature higher than ~40 °C; this could be because our data did not show isoprene temperature optimum up to 45 °C. Our results are consistent with the hypothesis of the isoprene functional role in protecting plants from high temperatures and highlight the need to include leaf phenology effects in isoprene emission models.
Resumo:
Dissertação de mestrado em Técnicas de Caracterização e Análise Química
Resumo:
Dissecting drivers of plant defence investment remains central for understanding the assemblage of communities across different habitats. There is increasing evidence that direct defence strategies against herbivores, including secondary metabolites production, differ along ecological gradients in response to variation in biotic and abiotic conditions. In contrast, intraspecific variation in indirect defences remains unexplored. Here, we investigated variation in herbivory rate, resistance to herbivores, and indirect defences in ant-attracting Vicia species along the elevation gradient of the Alps. Specifically, we compared volatile organic compounds (VOCs) and ant attraction in high and low elevation ecotypes. Consistent with adaptation to the lower herbivory conditions that we detected at higher elevations in the field, high elevation plants were visited by fewer ants and were more susceptible to herbivore attack. In parallel, constitutive volatile organic compound production and subsequent ant attraction were lower in the high elevation ecotypes. We observed an elevation-driven trade-off between constitutive and inducible production of VOCs and ant attraction along the environmental cline. At higher elevations, inducible defences increased, while constitutive defence decreased, suggesting that the high elevation ecotypes compensate for lower indirect constitutive defences only after herbivore attack. Synthesis. Overall, direct and indirect defences of plants vary along elevation gradients. Our findings show that plant allocation to defences are subject to trade-offs depending on local conditions, and point to a feedback mechanism linking local herbivore pressure, predator abundance and the defence investment of plants.
Multimodel inference and multimodel averaging in empirical modeling of occupational exposure levels.
Resumo:
Empirical modeling of exposure levels has been popular for identifying exposure determinants in occupational hygiene. Traditional data-driven methods used to choose a model on which to base inferences have typically not accounted for the uncertainty linked to the process of selecting the final model. Several new approaches propose making statistical inferences from a set of plausible models rather than from a single model regarded as 'best'. This paper introduces the multimodel averaging approach described in the monograph by Burnham and Anderson. In their approach, a set of plausible models are defined a priori by taking into account the sample size and previous knowledge of variables influent on exposure levels. The Akaike information criterion is then calculated to evaluate the relative support of the data for each model, expressed as Akaike weight, to be interpreted as the probability of the model being the best approximating model given the model set. The model weights can then be used to rank models, quantify the evidence favoring one over another, perform multimodel prediction, estimate the relative influence of the potential predictors and estimate multimodel-averaged effects of determinants. The whole approach is illustrated with the analysis of a data set of 1500 volatile organic compound exposure levels collected by the Institute for work and health (Lausanne, Switzerland) over 20 years, each concentration having been divided by the relevant Swiss occupational exposure limit and log-transformed before analysis. Multimodel inference represents a promising procedure for modeling exposure levels that incorporates the notion that several models can be supported by the data and permits to evaluate to a certain extent model selection uncertainty, which is seldom mentioned in current practice.