781 resultados para strain sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the nature of the infiltrating cells in Porphyromonas gingivalis-induced lesions and immunoglobulins in the serum samples of BALB/c (H-2(d)), C57BL6 (H-2(b)), DBA/2J (H-2(d)) and CBA/CaH (H-2(k)) mice. Mice were immunized intraperitoneally with P. gingivalis outer membrane antigens or sham-immunized with phosphate-buffered saline followed by subcutaneous challenge with live organisms 1 week after the final immunization. The resulting skin abscesses were excised 7 days later, cryostat sections cut and an immunoperoxidase method used to detect the presence of CD4(+) and CD8(+) T-cell subsets, CD14(+) macrophages and CD19(+) B cells. Peroxidase positive neutrophils and IgG1- and IgG2a-producing plasma cells were also identified. Anti P. gingivalis IgG1 and IgG2a subclass antibodies were determined in serum obtained by cardiac puncture. Very few CD8(+) T cells and CD19(+) B cells were found in any of the lesions. The percentages of CD4(+) cells, CD14(+) cells and neutrophils were similar in lesions of immunized BALB/c and C57BL6 mice, with a trend towards a higher percentage of CD14(+) cells in sham-immunized mice. The percentage of CD14(+) cells was higher than that of CD4(+) cells in immunized compared with sham-immunized DBA/2J mice. The percentages of CD4(+) and CD14(+) cells predominated in immunized CBA/CaH mice and CD4(+) cells in sham-immunized CBA/CaH mice. The percentage of neutrophils in immunized CBA/CaH mice was significantly lower than that of CD14(+) cells and CD4(+) cells in sham-immunized mice. IgG1(+) plasma cells were more dominant than IgG2a(+) cells in immunized BALB/c, C57BL6 and DBA/2J mice, whereas IgG2a(+) plasma cells were more obvious in sham-immunized mice. IgG2a(+) plasma cells were predominant in immunized and sham-immunized CBA/CaH mice. In the serum, specific anti-P. gingivalis IgG2a antibody levels (Th1 response) were higher than IgG1 levels (Th2 response) in sham-immunized CBA/CaH and DBA/2J mice. In immunized BALB/c mice, IgG2a levels were lower than IgG1 levels, while IgG2a levels were higher in immunized C57BL6 mice. In conclusion, this study has shown differences in the proportion of infiltrating leukocytes and in the subclasses of immunoglobulin produced locally and systemically in response to P. gingivalis in different strains of mice, suggesting a degree of genetic control over the response to P. gingivalis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plasmid DNA directing transcription of the infectious full-length RNA genome of Kunjin (KUN) virus in vivo from a mammalian expression promoter was used to vaccinate mice intramuscularly. The KUN viral cDNA encoded in the plasmid contained the mutation in the NS1 protein (Pro-250 to Leu) previously shown to attenuate KUN virus in weanling mice. KUN virus was isolated from the blood of immunized mice 3-4 days after DNA inoculation, demonstrating that infectious RNA was being transcribed in vivo; however, no symptoms of virus-induced disease were observed. By 19 days postimmunization, neutralizing antibody was detected in the serum of immunized animals. On challenge with lethal doses of the virulent New York strain of West Nile (WN) or wild-type KUN virus intracerebrally or intraperitoneally, mice immunized with as little as 0.1-1 mug of KUN plasmid DNA were solidly protected against disease. This finding correlated with neutralization data in vitro showing that serum from KUN DNA-immunized mice neutralized KUN and WN,viruses with similar efficiencies. The results demonstrate that delivery of an attenuated but replicating KUN virus via a plasmid DNA vector may provide an effective vaccination strategy against virulent strains of WN virus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential applications of macrocycles in chemistry and at its interfaces with biology and physics continue to emerge, one of which is as receptors for small molecules and ions. This review illustrates these applications with examples from the last ten years employing complexation as the binding mechanism; some of the systems presented have already found real-world sensor applications. In any case, the challenges remain to design more selective and sensitive receptors for guests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermoplastic elastomer/carbon nanotube composites are studied for sensor applications due to their excellent mechanical and electrical properties. Piezoresisitive properties of tri-block copolymer styrene-butadiene-styrene (SBS)/ carbon nanotubes (CNT) prepared by solution casting have been investigated. Young modulus of the SBS/CNT composites increases with the amount of CNT filler content present in the samples, without losing the high strain deformation on the polymer matrix (~1500 %). Further, above the percolation threshold these materials are unique for the development of large deformation sensors due to the strong piezoresistive response. Piezoresistive properties evaluated by uniaxial stretching in tensile mode and 4-point bending showed a Gauge Factors up to 120. The excellent linearity obtained between strain and electrical resistance makes these composites interesting for large strain piezoresistive sensors applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymeric materials have become the reference material for high reliability and performance applications. However, their performance in service conditions is difficult to predict, due in large part to their inherent complex morphology, which leads to non-linear and anisotropic behavior, highly dependent on the thermomechanical environment under which it is processed. In this work, a multiscale approach is proposed to investigate the mechanical properties of polymeric-based material under strain. To achieve a better understanding of phenomena occurring at the smaller scales, the coupling of a finite element method (FEM) and molecular dynamics (MD) modeling, in an iterative procedure, was employed, enabling the prediction of the macroscopic constitutive response. As the mechanical response can be related to the local microstructure, which in turn depends on the nano-scale structure, this multiscale approach computes the stress-strain relationship at every analysis point of the macro-structure by detailed modeling of the underlying micro- and meso-scale deformation phenomena. The proposed multiscale approach can enable prediction of properties at the macroscale while taking into consideration phenomena that occur at the mesoscale, thus offering an increased potential accuracy compared to traditional methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reaction of nine vector species of Chagas' disease to infection by seven different Trypanosoma cruzi strains; Berenice, Y, FL, CL, S. Felipe, Colombiana and Gávea, are examined and compared. On the basis of the insects' ability to establish and maintain the infection, vector species could be divided into two distinct groups which differ in their reaction to an acute infection by T. cruzi. While the proportion of positive bugs was found to be low in Triatoma infestans and Triatoma dimidiata it was high, ranging from 96.9% to 100% in the group of wild (Rhodnius neglectus, Triatoma rubrovaria)and essentially sylvatic vectors in process of adaptation to human dwellings, maintained under control following successful insecticidal elimination of Triatoma infestans (Panstrongylus megistus, Triatoma sordida and Triatoma pseudomaculata). An intermediate position is held by Triatoma brasiliensis and Rhodnius prolixus. This latter has been found to interchange between domestic and sylvatic environments. The most important finding is the strikingly good reaction between each species of the sylvatic bugs and practically all T. cruzi strains herein studied, thus indicating that the factors responsible for the excellent reaction of P.megistus to infection by Y strain, as previously reported also come into operation in the reaction of the same vector species to acute infections by five of the remaining T.cruzi strains. Comparison or data reported by other investigators with those herein described form the basis of the discussion of Dipetalogaster maximus as regards its superiority as a xenodiagnostic agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present an amorphous silicon device that can be used in two operation modes to measure the concentration of ions in solution. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use, for example, in the food industry. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the device can be operated in a light-assisted mode, where changes in the pH produce changes on the measured ac photocurrent. In alternative the device can be operated as a conventional ion selective field effect device where changes in the pH induce changes in the transistor's threshold voltage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Analyze the infectivity and storage resistance of cysts of the ME-49 strain of Toxoplasma gondii in artificially infected bovine milk and homemade fresh cheese. METHODS: Pasteurized bovine milk was infected with 10 cysts/ml of the ME-49 strain of T.gondii and inoculated in different groups of mice, immediately or after storage at 4ºC for 5, 10 and 20 days. Homemade fresh cheese was prepared with artificially infected milk, and also tested in groups of mice, using the same storage process. Infection was identified by the presence of cysts in the brain or serological testing in challenged mice after 5 weeks, confirmed by Western Blot and histology. RESULTS: The infectivity of cysts of the ME-49 strain of T.gondii was maintained in the milk even after storage for 20 days at refrigerator temperatures. Cysts were also able to survive the production process of homemade fresh cheese and storage for a period of 10 days in the same conditions. CONCLUSIONS: These data demonstrated that milk and dairy products could be an important source of T.gondii in human contamination, reinforcing the importance of milk pasteurization before any processing or ingestion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solubility of ethene in water and in the fermentation medium of Xanthobacter Py(2) was determined with a Ben-Naim-Baer type apparatus. The solubility measurements were carried out in the temperature range of (293.15 to 323.15) K and at atmospheric pressure with a precision of about +/- 0.3 %. The Ostwald coefficients, the mole fractions of the dissolved ethene, at the gas partial pressure of 101.325 kPa, and the Henry coefficients, at the water vapor pressure, were calculated using accurate thermodynamic relations. A comparison between the solubility of ethene in water and in the cultivation medium has shown that this gas is about 2.4 % more soluble in pure water. On the other hand, from the solubility temperature dependence, the Gibbs energy, enthalpy, and entropy changes for the process of transferring the solute from the gaseous phase to the liquid solutions were also determined. Moreover, the perturbed-chain statistical associating fluid theory equation of state (PC-SAFT EOS) model was used for the prediction of the solubility of ethene in water. New parameters, k(ij), are proposed for this system, and it was found that using a ky temperature-dependent PC-SAFT EOS describes more accurately the behavior solubilities of ethene in water at 101.325 kPa, improving the deviations to 1 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Ultrassonografia Cardiovascular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O VVI-Speckle Tracking é um método visual e quantitativo de avaliação dos parâmetros de deformação miocárdica utilizando a imagem bidimensional. Tem com principal vantagem em relação a outras metodologias a sua facilidade de execução. O SGL apresenta-se como o parâmetro de deformação miocárdica que mais precocemente deteta a alteração da função contrátil. Objectivo do estudo: determinar os valores do Strain Global Longitudinal (SGL), numa população de indivíduos normais utilizando a mais recente versão desta tecnologia e compará-los com outos valores já publicados, assim como a sua eventual variação com alguns parâmetros demográficos, como seja o género, idade e IMC.