714 resultados para screw
Resumo:
Cementite dissolution in cold-drawn pearlitic steel (0.8 wt.% carbon) wires has been studied by quantitative X-ray diffraction (XRD) and Mossbauer spectroscopy up to drawing strain 1.4. Quantification of cementite-phase fraction by Rietveld analysis has confirmed more than 50% dissolution of cementite phase at drawing strain 1.4. It is found that the lattice parameter of the ferrite phase determined by Rietveld refinement procedure remains nearly unchanged even after cementite dissolution. This confirms that the carbon atoms released after cementite dissolution do not dissolve in the ferrite lattice as Fe-C interstitial solid solution. Detailed analysis of broadening of XRD line profiles for the ferrite phase shows high density of dislocations (approximate to 10(15)/m(2)) in the ferrite matrix at drawing strain 1.4. The results suggest a dominant role of 111 screw dislocations in the cementite dissolution process. Post-deformation heat treatment leads to partial annihilation of dislocations and restoration of cementite phase. Based on these experimental observations, further supplemented by TEM studies, we have suggested an alternative thermodynamic mechanism of the dissolution process.
Resumo:
Environmental inputs can improve the level of innovation by interconnecting them with traditional inputs regarding the properties of materials and processes as a strategic eco-design procedure. Advanced engineered polymer composites are needed to meet the diverse needs of users for high-performance automotive, construction and commodity products that simultaneously maximize the sustainability of forest resources. In the current work, wood polymer composites (WPC) are studied to promote long-term resource sustainability and to decrease environmental impacts relative to those of existing products. A series of polypropylene wood–fiber composite materials having 20, 30, 40 and 50 wt. % of wood–fibers were prepared using twin-screw extruder and injection molding machine. Tensile and flexural properties of the composites were determined. Polypropylene (PP) as a matrix used in this study is a thermoplastic material, which is recyclable. Suitability of the prepared composites as a sustainable product is discussed.
Resumo:
This paper describes the use of liaison to better integrate product model and assembly process model so as to enable sharing of design and assembly process information in a common integrated form and reason about them. Liaison can be viewed as a set, usually a pair, of features in proximity with which process information can be associated. A liaison is defined as a set of geometric entities on the parts being assembled and relations between these geometric entities. Liaisons have been defined for riveting, welding, bolt fastening, screw fastening, adhesive bonding (gluing) and blind fastening processes. The liaison captures process specific information through attributes associated with it. The attributes are associated with process details at varying levels of abstraction. A data structure for liaison has been developed to cluster the attributes of the liaison based on the level of abstraction. As information about the liaisons is not explicitly available in either the part model or the assembly model, algorithms have been developed for extracting liaisons from the assembly model. The use of liaison is proposed to enable both the construction of process model as the product model is fleshed out, as well as maintaining integrity of both product and process models as the inevitable changes happen to both design and the manufacturing environment during the product lifecycle. Results from aerospace and automotive domains have been provided to illustrate and validate the use of liaisons. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Crystals of Boc-gamma y(4)(R)Val-Val-OH undergo a reversible first-order single crystal to single crystal phase transition at T-c approximate to 205 K from the orthorhombic space group P22(1)2(1) (Z' = 1) to the monoclinic space group P2(1) (Z' = 2) with a hysteresis of similar to 2.1 K. The low-temperature monoclinic form is best described as a nonmerohedral twin with similar to 50% contributions from its two components. The thermal behavior of the dipeptide crystals was characterized by differential scanning calorimetry experiments. Visual changes in birefringence of the sample during heating and cooling cycles on a hot-stage microscope with polarized light supported the phase transition. Variable-temperature unit cell check measurements from 300 to 100 K showed discontinuity in the volume and cell parameters near the transition temperature, supporting the first-order behavior. A detailed comparison of the room-temperature orthorhombic form with the low-temperature (100 K) monoclinic form revealed that the strong hydrogen-bonding motif is retained in both crystal systems, whereas the non-covalent interactions involving side chains of the dipeptide differ significantly, leading to a small change in molecular conformation in the monoclinic form as well as a small reorientation of the molecules along the ac plane. A rigid-body thermal motion analysis (translation, libration, screw; correlation of translation and libration) was performed to study the crystal entropy. The reversible nature of the phase transition is probably the result of an interplay between enthalpy and entropy: the low-temperature monoclinic form is enthalpically favored, whereas the room-temperature orthorhombic form is entropically favored.
Resumo:
This paper investigates the instantaneous spatial higher pair to lower pair substitute-connection which is kinematically equivalent up to acceleration analysis for two smooth surfaces in point contact. The existing first-order equivalent substitute-connection consisting of a Hooke's joint (U-joint) and a spherical joint (S-joint) connected by an additional link is extended up to second-order. A two step procedure is chalked out for achieving this equivalence. First, the existing method is employed for velocity equivalence. In the second step, the two centers of substitution are obtained as a conjugate relationship involving the principal normal curvatures of the surfaces at the contact point and the screw coordinates of the instantaneous screw axis (ISA) of the first-order relative motion. Unlike the classical planar replacement, this particular substitution cannot be done by merely examining the profiles of the contacting surfaces. An illustrative example of a three-link direct-contact mechanism is presented. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
This work deals with the transient analysis of flexible multibody systems within a hybrid finite element framework. Hybrid finite elements are based on a two-field variational formulation in which the displacements and stresses are interpolated separately yielding very good coarse mesh accuracy. Most of the literature on flexible multibody systems uses beam-theory-based formulations. In contrast, the use of hybrid finite elements uses continuum-based elements, thus avoiding the problems associated with rotational degrees of freedom. In particular, any given three-dimensional constitutive relations can be directly used within the framework of this formulation. Since the coarse mesh accuracy as compared to a conventional displacement-based formulation is very high, the scheme is cost effective as well. A general formulation is developed for the constrained motion of a given point on a line manifold, using a total Lagrangian method. The multipoint constraint equations are implemented using Lagrange multipliers. Various kinds of joints such as cylindrical, prismatic, and screw joints are implemented within this general framework. Hinge joints such as spherical, universal, and revolute joints are obtained simply by using shared nodes between the bodies. In addition to joints, the formulation and implementation details for a DC motor actuator and for prescribed relative rotation are also presented. Several example problems illustrate the efficacy of the developed formulation.
Resumo:
A full-scale experimental study on the structural performance of load-bearing wall panels made of cold-formed steel frames and boards is presented. Six different types of C-channel stud, a total of 20 panels with one middle stud and 10 panels with two middle studs were tested under vertical compression until failure. For panels, the main variables considered are screw spacing (300 mm, 400 mm, or 600 mm) in the middle stud, board type (oriented strand board - OSB, cement particle board - CPB, or calcium silicate board - CSB), board number (no sheathing, one-side sheathing, or two-side sheathing), and loading type (1, 3, or 4-point loading). The measured load capacity of studs and panels agrees well with analytical prediction. Due to the restraint by rivet connections between stud and track, the effective length factor for the middle stud and the side stud in a frame (unsheathed panel) is reduced to 0.90 and 0.84, respectively. The load carrying capacity of a stud increases significantly whenever one- or two-side sheathing is used, although the latter is significantly more effective. It is also dependent upon the type of board used. Whereas panels with either OSB or CPB boards have nearly identical load carrying capacity, panels with CSB boards are considerably weaker. Screw spacing affects the load carrying capacity of a stud. When the screw spacing on the middle stud in panels with one-side sheathing is reduced from 600 mm to 300 mm, its load carrying capacity increases by 14.5 %, 20.6% and 94.2% for OSB, CPB and CSB, respectively.
Resumo:
Results of tensile and compression tests on a short-glass-fiber-reinforced thermotropic liquid crystalline polymer are presented. The effect of strain rate on the compression stress-strain characteristics has been investigated over a wide range of strain rates epsilon between 10(-4) and 350 s-1. The low-strain-rate tests were conducted using a screw-driven universal tensile tester, while the high-strain-rate tests were carried out using the split Hopkinson pressure bar technique. The compression modulus was shown to vary with log10 (epsilon) in a bilinear manner. The compression modulus is insensitive to strain rate in the low-strain-rate regime (epsilon = 10(-4) - 10(-2) s-1), but it increases more rapidly with epsilon at higher epsilon. The compression strength changes linearly with log10 (epsilon) over the entire strain-rate range. The fracture surfaces were examined by scanning electron microscopy.
Resumo:
A number of cell-cell interactions in the nervous system are mediated by immunoglobulin gene superfamily members. For example, neuroglian, a homophilic neural cell adhesion molecule in Drosophila, has an extracellular portion comprising six C- 2 type immunoglobulin-like domains followed by five fibronectin type III (FnIII) repeats. Neuroglian shares this domain organization and significant sequence identity with Ll, a murine neural adhesion molecule that could be a functional homologue. Here I report the crystal structure of a proteolytic fragment containing the first two FnIII repeats of neuroglian (NgFn 1,2) at 2.0Å. The interpretation of photomicrographs of rotary shadowed Ng, the entire extracellular portion of neuroglian, and NgFnl-5, the five neuroglian Fn III domains, is also discussed.
The structure of NgFn 1,2 consists of two roughly cylindrical β-barrel structural motifs arranged in a head-to-tail fashion with the domains meeting at an angle of ~120, as defined by the cylinder axes. The folding topology of each domain is identical to that previously observed for single FnIII domains from tenascin and fibronectin. The domains of NgFn1,2 are related by an approximate two fold screw axis that is nearly parallel to the longest dimension of the fragment. Assuming this relative orientation is a general property of tandem FnIII repeats, the multiple tandem FnIII domains in neuroglian and other proteins are modeled as thin straight rods with two domain zig-zag repeats. When combined with the dimensions of pairs of tandem immunoglobulin-like domains from CD4 and CD2, this model suggests that neuroglian is a long narrow molecule (20 - 30 Å in diameter) that extends up to 370Å from the cell surface.
In photomicrographs, rotary shadowed Ng and NgFn1-5 appear to be highly flexible rod-like molecules. NgFn 1-5 is observed to bend in at least two positions and has a mean total length consistent with models generated from the NgFn1,2 structure. Ng molecules have up to four bends and a mean total length of 392 Å, consistent with a head-to-tail packing of neuroglian's C2-type domains.
Resumo:
The dynamic properties of a structure are a function of its physical properties, and changes in the physical properties of the structure, including the introduction of structural damage, can cause changes in its dynamic behavior. Structural health monitoring (SHM) and damage detection methods provide a means to assess the structural integrity and safety of a civil structure using measurements of its dynamic properties. In particular, these techniques enable a quick damage assessment following a seismic event. In this thesis, the application of high-frequency seismograms to damage detection in civil structures is investigated.
Two novel methods for SHM are developed and validated using small-scale experimental testing, existing structures in situ, and numerical testing. The first method is developed for pre-Northridge steel-moment-resisting frame buildings that are susceptible to weld fracture at beam-column connections. The method is based on using the response of a structure to a nondestructive force (i.e., a hammer blow) to approximate the response of the structure to a damage event (i.e., weld fracture). The method is applied to a small-scale experimental frame, where the impulse response functions of the frame are generated during an impact hammer test. The method is also applied to a numerical model of a steel frame, in which weld fracture is modeled as the tensile opening of a Mode I crack. Impulse response functions are experimentally obtained for a steel moment-resisting frame building in situ. Results indicate that while acceleration and velocity records generated by a damage event are best approximated by the acceleration and velocity records generated by a colocated hammer blow, the method may not be robust to noise. The method seems to be better suited for damage localization, where information such as arrival times and peak accelerations can also provide indication of the damage location. This is of significance for sparsely-instrumented civil structures.
The second SHM method is designed to extract features from high-frequency acceleration records that may indicate the presence of damage. As short-duration high-frequency signals (i.e., pulses) can be indicative of damage, this method relies on the identification and classification of pulses in the acceleration records. It is recommended that, in practice, the method be combined with a vibration-based method that can be used to estimate the loss of stiffness. Briefly, pulses observed in the acceleration time series when the structure is known to be in an undamaged state are compared with pulses observed when the structure is in a potentially damaged state. By comparing the pulse signatures from these two situations, changes in the high-frequency dynamic behavior of the structure can be identified, and damage signals can be extracted and subjected to further analysis. The method is successfully applied to a small-scale experimental shear beam that is dynamically excited at its base using a shake table and damaged by loosening a screw to create a moving part. Although the damage is aperiodic and nonlinear in nature, the damage signals are accurately identified, and the location of damage is determined using the amplitudes and arrival times of the damage signal. The method is also successfully applied to detect the occurrence of damage in a test bed data set provided by the Los Alamos National Laboratory, in which nonlinear damage is introduced into a small-scale steel frame by installing a bumper mechanism that inhibits the amount of motion between two floors. The method is successfully applied and is robust despite a low sampling rate, though false negatives (undetected damage signals) begin to occur at high levels of damage when the frequency of damage events increases. The method is also applied to acceleration data recorded on a damaged cable-stayed bridge in China, provided by the Center of Structural Monitoring and Control at the Harbin Institute of Technology. Acceleration records recorded after the date of damage show a clear increase in high-frequency short-duration pulses compared to those previously recorded. One undamage pulse and two damage pulses are identified from the data. The occurrence of the detected damage pulses is consistent with a progression of damage and matches the known chronology of damage.
Resumo:
The lateral migration of neutrally buoyant rigid spheres in two-dimensional unidirectional flows was studied theoretically. The cases of both inertia-induced migration in a Newtonian fluid and normal stress-induced migration in a second-order fluid were considered. Analytical results for the lateral velocities were obtained, and the equilibrium positions and trajectories of the spheres compared favorably with the experimental data available in the literature. The effective viscosity was obtained for a dilute suspension of spheres which were simultaneously undergoing inertia-induced migration and translational Brownian motion in a plane Poiseuille flow. The migration of spheres suspended in a second-order fluid inside a screw extruder was also considered.
The creeping motion of neutrally buoyant concentrically located Newtonian drops through a circular tube was studied experimentally for drops which have an undeformed radius comparable to that of the tube. Both a Newtonian and a viscoelastic suspending fluid were used in order to determine the influence of viscoelasticity. The extra pressure drop due to the presence of the suspended drops, the shape and velocity of the drops, and the streamlines of the flow were obtained for various viscosity ratios, total flow rates, and drop sizes. The results were compared with existing theoretical and experimental data.
Resumo:
[ES]En este trabajo se expone un estudio experimental del proceso de taladrado por fricción, más conocido como Friction Drilling y posterior roscado por laminación, en uniones de chapas de acero y aluminio, muy utilizadas en multitud de sectores, que se caracteriza por la ausencia de tuercas. La base de esta técnica es el calor producido por el rozamiento al entrar en contacto la herramienta rotativa con el material, causando el reblandecimiento del material, la fluencia y la deformación de éste. De este modo, se generará una copa cónica, que se roscará por laminación. En este trabajo se va a estudiar la viabilidad del proceso experimentalmente, obteniendo variables de entrada del proceso óptimas que generen una unión de calidad, atendiendo a diferentes aspectos. Sin embargo, se centra sobre todo en analizar la calidad de la unión en lo que se refiere a la compatibilidad de los materiales. Se estudiará la corrosión galvánica por una parte entre acero y aluminio y, por otra parte, entre acero, aluminio y el material del tornillo. Una vez concluido el trabajo, se espera obtener un proceso de unión de materiales disímiles sin tuerca, ofreciendo una mayor calidad que los procesos implementados actualmente.
Resumo:
During the 1950s and 1960s, F.J.H. Mackereth developed and published plans for a series of pneumatic samplers for lake sediments. Unfortunately, as the equipment was continually evolving during ensuing research, no user manuals, beyond the original publication, had been produced. Over the last few years there have been a few potentially very serious accidents with the 1-metre corer, which has prompted the authors to carry out a risk assessment. This highlighted two weaknesses in the design and its later developments. They can be corrected simply by checking for screw threads that may have been added to the exhaust port on the mini-corer, and by changing the operating procedure. An A4 nine-page user manual is now available from the authors. A small charge ( pound sterling 10 in 1998) will be made to cover handling costs and postage.
Resumo:
O afrouxamento dos parafusos protéticos é descrito na literatura como uma das complicações mais frequentes das próteses sobre implantes. Durante sua confecção, os profissionais sentem necessidade de remover várias vezes as próteses e/ou componentes protéticos, soltando e re-apertando os parafusos repetidamente. O principal objetivo deste trabalho foi avaliar a variação do torque de remoção de parafusos de fixação de pilares protéticos a implantes osteointegráveis após sucessivos ciclos de parafusamento e desparafusamento. Outro objetivo foi avaliar a influência do hexágono da base do pilar no torque de remoção dos parafusos. Para isso, foram utilizados 20 implantes de plataforma regular com hexágono externo e 20 pilares protéticos sextavados, que foram parafusados aos implantes com um parafuso de titânio, aplicando-se a este um torque de 32Ncm, por meio de um torquímetro digital. Os conjuntos implante/pilar/parafuso foram divididos em dois grupos: (1) pilares cujo hexágono da base foram removidos e (2) pilares convencionais, com hexágono na base. Cada conjunto recebeu uma restauração provisória e foi submetido a ciclagem mecânica por 15 minutos. Depois, os parafusos foram removidos, medindo-se o torque de remoção. Esta sequência foi repetida dez vezes e então o parafuso foi trocado por outro sem uso, e mais um ciclo foi realizado. Uma análise de regressão linear demonstrou nos dois grupos uma queda do torque de remoção do parafuso ao longo dos repetidos ciclos de inserção/remoção. A comparação entre os coeficientes da regressão nos dois grupos não revelou diferença entre eles. Também não houve diferença entre as médias das 5 últimas repetições e o 11 ciclo, com o parafuso novo. Concluiu-se que (1) repetidos parafusamentos e desparafusamentos promoveram a diminuição progressiva do torque de remoção dos parafusos, (2) a troca do parafuso por outro sem uso após dez ciclos de inserção/remoção não aumentou sua resistência ao afrouxamento, e (3) a remoção do hexágono da base do pilar protético não exerceu nenhum efeito sobre o torque de remoção do parafuso.
Resumo:
Os implantes osteointegráveis assumiram condição prioritária na reabilitação da perda dentária unitária ou múltipla em função das elevadas taxas de sucesso e previsibilidade no tratamento e vêm sendo cada vez mais utilizados por especialistas e clínicos. Atualmente existe a preocupação com a manutenção dos tecidos moles periimplantares, principalmente em áreas estéticas. De modo geral, um ano após a instalação dos implantes osteointegráveis ocorre uma perda óssea proximal de 1,5 mm e em média 0,1 mm durante os anos subsequentes. Nos últimos anos, achados clínicos evidenciaram menor perda óssea inicial associada a intermediários de diâmetro reduzido em relação à plataforma dos implantes. Com o objetivo de comparar, por meio de imagens radiográficas o comportamento ósseo proximal ao redor de implantes osteointegráveis com plataformas convencionais e plataformas de diâmetro intermediário reduzido, foi estabelecido o seguinte desenho de estudo clínico prospectivo: em 08 pacientes totalmente edentados, foram instalados 40 implantes, 5 implantes mandibulares por paciente. Cada paciente recebeu 3 implantes com plataforma convencional e 2 com plataforma associada aos intermediários de diâmetro reduzido (cone morse). Foram confeccionadas próteses em resina acrílica e fixadas precocemente aos implantes por intermédio de parafusos, seguindo o modelo protocolo Bränemark. Foram feitas radiografias periapicais padronizadas em intervalos de 21 dias, 3, 6 e 12 meses, após a instalação dos implantes. As imagens radiográficas foram digitalizadas e realizada a subtração radiográfica digital pelo programa emago, sendo comparadas com a radiografia inicial. Os resultados obtidos neste estudo mostraram uma regularidade no remodelamento ósseo ao longo do tempo para todos os implantes, não tendo sido encontradas diferenças significativas entre os diferentes implantes analisados.