901 resultados para screen cylinder
Resumo:
The flow around circular smooth fixed cylinder in a large range of Reynolds numbers is considered in this paper. In order to investigate this canonical case, we perform CFD calculations and apply verification & validation (V&V) procedures to draw conclusions regarding numerical error and, afterwards, assess the modeling errors and capabilities of this (U)RANS method to solve the problem. Eight Reynolds numbers between Re = 10 and Re 5 x 10(5) will be presented with, at least, four geometrically similar grids and five discretization in time for each case (when unsteady), together with strict control of iterative and round-off errors, allowing a consistent verification analysis with uncertainty estimation. Two-dimensional RANS, steady or unsteady, laminar or turbulent calculations are performed. The original 1994 k - omega SST turbulence model by Menter is used to model turbulence. The validation procedure is performed by comparing the numerical results with an extensive set of experimental results compiled from the literature. [DOI: 10.1115/1.4007571]
Resumo:
The present study investigated whether postural responses are influenced by the stability constraint of a voluntary, manual task. We also examined how task constraint and first experience (the condition with which the participants started the experiment) influence the kinematic strategies used to simultaneously accomplish a postural response and a voluntary task. Twelve healthy, older adults were perturbed during standing, while holding a tray with a cylinder placed with the flat side down (low constraint, LC) or with the rolling, round side down (high constraint, HC). Central set changed according to the task constraint, as shown by a higher magnitude of both the gastrocnemius and tibialis anterior muscle activation bursts in the HC than in the LC condition. This increase in muscle activation was not reflected, however, in changes in the center of pressure or center of mass displacement. Task constraint influenced the peak shoulder flexion for the voluntary tray task but not the peak hip flexion for the postural task. In contrast, first experience influenced the peak hip flexion but not the peak shoulder flexion. These results suggest an interaction between two separate control mechanisms for automatic postural responses and voluntary stabilization tasks.
Resumo:
The congenital transmission of Trypanosoma cruzi has gained epidemiological importance because it is partially responsible for the spread of Chagas disease worldwide. The feasibility of a cure when infected children are treated early makes the detection of congenital infection a valuable goal toward the control of the disease. Here, the authors review and discuss the findings of Bua et al., who quantified the parasitemia of infected women and their newborns by quantitative PCR. The authors demonstrate that the maternal parasite burden is directly related to the risk of neonatal infection. This study points out the importance of a quantitative screen for T. cruzi in pregnant women who live in, or have traveled to, endemic areas for improving the diagnosis of infected newborns and providing prompt treatment.
Resumo:
Background Calstabins 1 and 2 bind to Ryanodine receptors regulating muscle excitation-contraction coupling. Mutations in Ryanodine receptors affecting their interaction with calstabins lead to different cardiac pathologies. Animal studies suggest the involvement of calstabins with dilated cardiomyopathy. Results We tested the hypothesis that calstabins mutations may cause dilated cardiomyopathy in humans screening 186 patients with idiopathic dilated cardiomyopathy for genetic alterations in calstabins 1 and 2 genes (FKBP12 and FKBP12.6). No missense variant was found. Five no-coding variations were found but not related to the disease. Conclusions These data corroborate other studies suggesting that mutations in FKBP12 and FKBP12.6 genes are not commonly related to cardiac diseases.
Resumo:
OBJECTIVE: The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. METHODS: To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. RESULTS: A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. CONCLUSION: The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.
Resumo:
In this work, we considered the flow around two circular cylinders of equal diameter placed in tandem with respect to the incident uniform flow. The upstream cylinder was fixed and the downstream cylinder was completely free to move in the cross-stream direction, with no spring or damper attached to it. The centre-to-centre distance between the cylinders was four diameters, and the Reynolds number was varied from 100 to 645. We performed two- and three-dimensional simulations of this flow using a Spectral/hp element method to discretise the flow equations, coupled to a simple Newmark integration routine that solves the equation of the dynamics of the cylinder. The differences of the behaviours observed in the two- and three-dimensional simulations are highlighted and the data is analysed under the light of previously published experimental results obtained for higher Reynolds numbers.
The role of wake stiffness on the wake-induced vibration of the downstream cylinder of a tandem pair
Resumo:
When a pair of tandem cylinders is immersed in a flow the downstream cylinder can be excited into wake-induced vibrations (WIV) due to the interaction with vortices coming from the upstream cylinder. Assi, Bearman & Meneghini ( J. Fluid Mech. , vol. 661, 2010, pp. 365–401) concluded that the WIV excitation mechanism has its origin in the unsteady vortex–structure interaction encountered by the cylinder as it oscillates across the wake. In the present paper we investigate how the cylinder responds to that excitation, characterising the amplitude and frequency of response and its dependency on other parameters of the system. We introduce the concept of wake stiffness , a fluid dynamic effect that can be associated, to a first approximation, with a linear spring with stiffness proportional to Re and to the steady lift force occurring for staggered cylinders. By a series of experiments with a cylinder mounted on a base without springs we verify that such wake stiffness is not only strong enough to sustain oscillatory motion, but can also dominate over the structural stiffness of the system. We conclude that while unsteady vortex–structure interactions provide the energy input to sustain the vibrations, it is the wake stiffness phenomenon that defines the character of the WIV response
Resumo:
The present study aims at analyzing how dark humour as a cinematic genre travels cross-culturally through a specific mode of audiovisual translation, i.e. dubbing. In particular, it takes into consideration the processes involved in dubbing humour from English into Italian as observed in the English- and Italian-language versions of ten British and American dark comedies from the 1940s to the 2000s. In an attempt to identify some of the main mechanisms of the dark humour genre, the humorous content of the films was analyzed in terms of the elements on which specific scenes are based, mainly the non-verbal and verbal components. In the cases in which verbal elements were involved, i.e. the examples of verbally expressed humour, the analysis was concerned with whether they were adapted into Italian and to what effect. Quantification of the different kinds of dark humour revealed that in the sample of dark comedies verbal dark humour had a higher frequency (85.3%) than non-verbal dark humour (14.7%), which partially disconfirmed the first part of the research hypothesis. However, the significance of contextual elements in the conveying of dark humour, both in the form of Nsp VEH (54.31%) and V-V (V+VE) (21.68%), provided support for the hypothesis that, even when expressed verbally, dark humour is more closely linked to context-based rather than purely linguistic humour (4.9%). The second part of the analysis was concerned with an investigation of the strategies adopted for the translation of verbal dark humour elements from the SL (English) into the TL (Italian) through the filter of dubbing. Four translational strategies were identified as far as the rendering of verbal dark humour is concerned: i) complete omission; ii) weakening; iii) close rendering; and iv) increased effect. Complete omission was found to be the most common among these strategies, with 80.9% of dark humour examples being transposed in a way that kept the ST’s function substantially intact. Weakening of darkly humorous lines was applied in 12% of cases, whereas increased effect accounted for 4.6% and complete omission for 2.5%. The fact that for most examples of Nsp VEH (84.9%) and V-AC (V+VE) (91.4%) a close rendering effect was observed and that 12 out of 21 examples of V-AC (PL) (a combined 57%) were either omitted or weakened seemed to confirm, on the one hand, the complexity of the translation process required by cases of V-AC (PL) and V-AC (CS). On the other hand, as suggested in the second part of the research hypothesis, the data might be interpreted as indicating that lesser effort on the translator/adaptor’s part is involved in the adaptation of V-AC (Nsp VEH) and V-V (V+VE). The issue of the possible censorial intervention undergone by examples of verbal dark humour in the sample still remains unclear.
Resumo:
PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.
Resumo:
We present an experimental and numerical study examining the dynamics of a gravity-driven contact line of a thin viscous film traveling down the outside of a vertical cylinder of radius R. Experiments on cylinders with radii ranging between 0.159 and 3.81 cm show that the contact line is unstable to a fingering pattern for two fluids with differing viscosities, surface tensions, and wetting properties. The dynamics of the contact line is studied and results are compared to previous studies of inclined plane experiments in order to understand the influence substrate curvature plays on the fingering pattern. A lubrication model is derived for the film height in the limit that ε = H/R≪1, where H is the upstream film thickness, and in terms of a Bond number ρgR3/(γH), and the linear stability of the contact line is analyzed using traveling wave solutions. Curvature controls the capillary ridge height of the traveling wave and the range of unstable wavelength when ε = O(10-1), whereas the shape and stability of the contact line converge to the behavior one observes on a vertical plane when ε ≤ O(10-2). The most unstable wave mode, cutoff wave mode for neutral stability, and maximum growth rate scale as 0.45 where = ρgR2/γ ≥ 1.3, and the contact line is unstable to fingering when ≥ 0.56. Using the experimental data to extrapolate outside the range of validity of the thin film model, we estimate the contact line is stable when <0.56. Agreement is excellent between the model and the experimental data for the wave number (i.e., number of fingers) and wavelength of the fingering pattern that forms along the contact line.
Resumo:
Medulloblastoma is the most common malignant brain tumor in children and is associated with a poor outcome. We were interested in gaining further insight into the potential of targeting the human kinome as a novel approach to sensitize medulloblastoma to chemotherapeutic agents. A library of small interfering RNA (siRNA) was used to downregulate the known human protein and lipid kinases in medulloblastoma cell lines. The analysis of cell proliferation, in the presence or absence of a low dose of cisplatin after siRNA transfection, identified new protein and lipid kinases involved in medulloblastoma chemoresistance. PLK1 (polo-like kinase 1) was identified as a kinase involved in proliferation in medulloblastoma cell lines. Moreover, a set of 6 genes comprising ATR, LYK5, MPP2, PIK3CG, PIK4CA, and WNK4 were identified as contributing to both cell proliferation and resistance to cisplatin treatment in medulloblastoma cells. An analysis of the expression of the 6 target genes in primary medulloblastoma tumor samples and cell lines revealed overexpression of LYK5 and PIK3CG. The results of the siRNA screen were validated by target inhibition with specific pharmacological inhibitors. A pharmacological inhibitor of p110γ (encoded by PIK3CG) impaired cell proliferation in medulloblastoma cell lines and sensitized the cells to cisplatin treatment. Together, our data show that the p110γ phosphoinositide 3-kinase isoform is a novel target for combinatorial therapies in medulloblastoma.
Resumo:
Subclinical hypothyroidism, defined as an elevated thyroid stimulating hormone and normal thyroxine level, is common with aging, particularly after 65 years old. This condition is potentially associated with important consequences, such as cardiovascular diseases and cognitive disorders. So far, indications for screening and thyroxine replacement therapy are still controversial. In this review, we examine the data on those risks and the potential benefits of the treatment. We also present a large European randomized clinical trial that should clarify this controversy, in order to improve clinical care of patients with subclinical hypothyroidism and to give reliable data on maintaining good health among the elderly.
Resumo:
Pneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs.