973 resultados para rectangular aquarium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present a technique for the shaping of short pulses based on the use of superstructured fiber Bragg gratings (SSFBGs), We apply this technique to demonstrate the generation of 20-ps rectangular pulses by phase and amplitude profiling of 2.5-ps soliton pulses. Numerical calculations validate our experimental findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a new nonlinear optical loop mirror based configuration capable of regenerating regular rectangular quadrature amplitude modulated (QAM) signals. The scheme achieves suppression of noise distortion on both signal quadratures through the realization of two orthogonal regenerative Fourier transformations. Numerical simulations show the performance of the scheme for high constellation complexities (including 256-QAM formats).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a theoretical model on the vibration analysis of micro scale fluid-loaded rectangular isotropic plates, based on the Lamb's assumption of fluid-structure interaction and the Rayleigh-Ritz energy method. An analytical solution for this model is proposed, which can be applied to most cases of boundary conditions. The dynamical experimental data of a series of microfabricated silicon plates are obtained using a base-excitation dynamic testing facility. The natural frequencies and mode shapes in the experimental results are in good agreement with the theoretical simulations for the lower order modes. The presented theoretical and experimental investigations on the vibration characteristics of the micro scale plates are of particular interest in the design of microplate based biosensing devices. Copyright © 2009 by ASME.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new wideband transition between substrate integrated waveguide (SIW) and rectangular waveguide (RWG) that resembles a right angle waveguide E-bend at Ku/K band is presented. The transition has removable but stable mounting, requires only PCB fabrication and has adaptable quality and bandwidth characteristics depending on the number of substrate layers used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coral diseases are a major factor in the decline of coral reefs worldwide, and a large proportion of studies focusing on disease causation use aquaria to control variables that affect disease occurrence and development. Public aquaria can therefore provide an invaluable resource to study the factors contributing to health and disease. In November 2010 the corals within the main display tank at the Horniman Museum and Gardens, London, UK, underwent a severe stress event due to reduced water quality, which resulted in death of a large number of coral colonies. Three separate colonies of two species of reef coral, Seritopora hystrix and Montipora capricornis showing signs of stress and acute tissue loss were removed from the display tank and placed in a research tank with improved water quality. Both coral species showed a significant difference in 16S rRNA gene bacterial diversity between healthy and stressed states (S. hystrix; ANOSIM, R=0.44, p=0.02 and M. capricornis; ANOSIM, R=0.33, p=0.01), and between the stressed state and the recovering corals. After four months the bacterial communities had returned to a similar state to that seen in healthy corals of the same species. The bacterial communities associated with the two coral species were distinct, despite them
being reared under identical environmental conditions. Despite the environmental perturbation being identical different visual signs were seen in each species and distinctly different bacterial communities associated with the stressed state occurred within them. Recovery of the visually healthy state was associated with a return of the bacterial community, within two months, to the pre-disturbance state. These observations suggest that coral-associated microbial communities are remarkably resilient and return to a very similar stable state following disturbance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently gap waveguides have been shown as a potential alternative to conventional waveguides in the millimeter-wave band. Groove Gap Waveguide (GGW) has until now been studied though direct correspondence with rectangular waveguide with the same propagation channel dimensions. However there have been observed differences in the above cutoff propagation characteristics between these waveguide types. Furthermore, the behaviour of GGW below cutoff remains unknown. This work presents a discussion of below and above cutoff propagation characteristics, and introduces a simple model that explains observed GGW behavior and establishes its propagation characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous studies of the dual-mode scramjet isolator, a critical component in preventing inlet unstart and/or vehicle loss by containing a collection of flow disturbances called a shock train, have been performed since the dual-mode propulsion cycle was introduced in the 1960s. Low momentum corner flow and other three-dimensional effects inherent to rectangular isolators have, however, been largely ignored in experimental studies of the boundary layer separation driven isolator shock train dynamics. Furthermore, the use of two dimensional diagnostic techniques in past works, be it single-perspective line-of-sight schlieren/shadowgraphy or single axis wall pressure measurements, have been unable to resolve the three-dimensional flow features inside the rectangular isolator. These flow characteristics need to be thoroughly understood if robust dual-mode scramjet designs are to be fielded. The work presented in this thesis is focused on experimentally analyzing shock train/boundary layer interactions from multiple perspectives in aspect ratio 1.0, 3.0, and 6.0 rectangular isolators with inflow Mach numbers ranging from 2.4 to 2.7. Secondary steady-state Computational Fluid Dynamics studies are performed to compare to the experimental results and to provide additional perspectives of the flow field. Specific issues that remain unresolved after decades of isolator shock train studies that are addressed in this work include the three-dimensional formation of the isolator shock train front, the spatial and temporal low momentum corner flow separation scales, the transient behavior of shock train/boundary layer interaction at specific coordinates along the isolator's lateral axis, and effects of the rectangular geometry on semi-empirical relations for shock train length prediction. A novel multiplane shadowgraph technique is developed to resolve the structure of the shock train along both the minor and major duct axis simultaneously. It is shown that the shock train front is of a hybrid oblique/normal nature. Initial low momentum corner flow separation spawns the formation of oblique shock planes which interact and proceed toward the center flow region, becoming more normal in the process. The hybrid structure becomes more two-dimensional as aspect ratio is increased but corner flow separation precedes center flow separation on the order of 1 duct height for all aspect ratios considered. Additional instantaneous oil flow surface visualization shows the symmetry of the three-dimensional shock train front around the lower wall centerline. Quantitative synthetic schlieren visualization shows the density gradient magnitude approximately double between the corner oblique and center flow normal structures. Fast response pressure measurements acquired near the corner region of the duct show preliminary separation in the outer regions preceding centerline separation on the order of 2 seconds. Non-intrusive Focusing Schlieren Deflectometry Velocimeter measurements reveal that both shock train oscillation frequency and velocity component decrease as measurements are taken away from centerline and towards the side-wall region, along with confirming the more two dimensional shock train front approximation for higher aspect ratios. An updated modification to Waltrup \& Billig's original semi-empirical shock train length relation for circular ducts based on centerline pressure measurements is introduced to account for rectangular isolator aspect ratio, upstream corner separation length scale, and major- and minor-axis boundary layer momentum thickness asymmetry. The latter is derived both experimentally and computationally and it is shown that the major-axis (side-wall) boundary layer has lower momentum thickness compared to the minor-axis (nozzle bounded) boundary layer, making it more separable. Furthermore, it is shown that the updated correlation drastically improves shock train length prediction capabilities in higher aspect ratio isolators. This thesis suggests that performance analysis of rectangular confined supersonic flow fields can no longer be based on observations and measurements obtained along a single axis alone. Knowledge gained by the work performed in this study will allow for the development of more robust shock train leading edge detection techniques and isolator designs which can greatly mitigate the risk of inlet unstart and/or vehicle loss in flight.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A temperature pause introduced in a simple single-step thermal decomposition of iron, with the presence of silver seeds formed in the same reaction mixture, gives rise to novel compact heterostructures: brick-like Ag@Fe3O4 core-shell nanoparticles. This novel method is relatively easy to implement, and could contribute to overcome the challenge of obtaining a multifunctional heteroparticle in which a noble metal is surrounded by magnetite. Structural analyses of the samples show 4 nm silver nanoparticles wrapped within compact cubic external structures of Fe oxide, with curious rectangular shape. The magnetic properties indicate a near superparamagnetic like behavior with a weak hysteresis at room temperature. The value of the anisotropy involved makes these particles candidates to potential applications in nanomedicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work evaluated the effect of low doses of X-irradiation on the repairing process of sutured and nonsutured skin wounds in rats. For that, rats underwent a surgical proceedure, in which a 20 x 5-millimeter rectangular wound approximately 2-millimeter-deep was made in the dorsal region of each animal, and were divided in four groups: nonirradiated nonsutured; irradiated nonsutured ; nonirradiated sutured and irradiated sutured. The animals under irradiation were protected, during exposure, with a 2-millimeter-thick lead apron in such a way that only the incision was irradiated. Each animal was submitted to 18 seconds of exposure, undergoing a total of 7.4 rads. The evaluation of the effects of X-rays on the repairing process was carried out through microscopic observation by means of hematoxylin-eosin staining for morphological evaluation, and silver impregnation under polarized light for the observation of collagen synthesis. The results have shown that X-irradiation has caused delay in the repairing process, but it did not stop its development. The irradiated nonsutured group was considered to show the greater delay when compared with the other groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the influence of different assessment time periods of submaximal tests on the determination of the maximal accumulated oxygen deficit (MAOD), through the adoption of different time slots of 4 to 6, 6 to 8 and 8 to 10 min. Ten cyclists with mean age of 27.5 ± 4.1 years, body mass 74.4 ± 12.7 kg and time experience of 9.8 ± 4.7 years participated in this study. The athletes underwent an incremental exercise test to determine the peak oxygen consumption (VO2peak), and four submaximal constant work-load test sessions (60, 70, 80 and 90% VO2peak) of 10 min in order to estimate the O2 demand (DEO2). The mean VO2 values obtained on each constant work-load for the 4 to 6, 6 to 8 and 8 to 10 min time-periods intervals were used to perform a linear regression between the intensity and O2 consumption for each time-period. In addition, the subjects performed one supramaximal rectangular test (110% VO2peak) for the quantification of MAOD. There was no significant difference in VO2 between the different time-periods for all submaximal tests (P> 0.05). Similarly, no significant difference was found in DEAO2 and MAOD (P> 0.05). Furthermore, the values of MAOD for the three time-periods intervals showed good agreement and strong correlation. Thus, the data suggest that the submaximal tests used to estimate the values of MAOD can be reduced, at least in this type of sample, and with the use of a cycle simulator.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study describes the sperm morphology of the mayfly Hexagenia (Pseudeatonica) albivitta (Ephemeroptera). Its spermatozoon measures approximately 30 μm of which 9 μm corresponds to the head. The head is composed of an approximately round acrosomal vesicle and a cylindrical nucleus. The nucleus has two concavities, one in the anterior tip, where the acrosomal vesicle is inserted and a deeper one at its base, where the flagellum components are inserted. The flagellum is composed of an axoneme, a mitochondrion and a dense rod adjacent to the mitochondrion. A centriolar adjunct is also observed surrounding the axoneme in the initial portion of the flagellum and extends along the flagellum for at least 2 μm, surrounding the axoneme in a half-moon shape. The axoneme is the longest component of the flagellum, and it follows the 9+9+0 pattern, with no central pair of microtubules. At the posterior region of the flagellum, the mitochondrion has a dumb-bell shape in cross sections that, together with the rectangular mitochondrial-associated rod, is responsible for the flattened shape of the flagellum. An internal membrane is observed surrounding both mitochondrion and its associated structure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar as alterações nas inclinações dos dentes anteriores causadas pelo tratamento ortodôntico, utilizando-se aparelho Straight-Wire, prescrição II Capelozza, antes e após a fase de nivelamento com fios ortodônticos de aço de secção retangular. MÉTODOS: foram selecionados 17 indivíduos adultos de padrão facial II, má oclusão Classe II, indicados para tratamento ortodôntico compensatório. As inclinações dos dentes anteriores foram avaliadas em três tempos clínicos, após o uso dos fios ortodônticos de diâmetros 0,020" (T1); 0,019" x 0,025" (T2) e 0,021" x 0,025" (T3), através de exames de tomografia computadorizada. Empregou-se a análise de variância de Friedman, com nível de significância de 5%, na comparação entre os tempos. RESULTADOS: observou-se que o fios retangulares empregados não foram capazes de produzir uma mudança significativa na mediana da inclinação dentária, exceto por uma discreta alteração nos incisivos laterais inferiores (p<0,05). Por outro lado, constatou-se que a variação das inclinações observadas era menor no fio retangular 0,021" x 0,025", principalmente para os incisivos superiores (p<0,001). CONCLUSÃO: fios retangulares 0,021" x 0,025" produzem uma maior homogeneidade no grau de variação na inclinação dos incisivos superiores, embora sem mudança significativa na sua mediana.