Resumo:
Purpose: The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Materials and Methods: Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N(.)cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer`s test (p < 0.05). Results: When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mu m) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 mu m) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 mu m). On the tightened side, no significant differences were found between the groups (p > 0.05). Conclusions: Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.
Resumo:
This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 mu m [SD: 91.48] to 39.90 mu m [SD: 27.13]) and cpTi (118.56 mu m [51.35] to 27.87 mu m [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.
Resumo:
P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.
Resumo:
Research on paternalistic leadership (PL) has been based exclusively on national cultures´ differences. However there are cues that other contextual variables can add to the explanation of this construct. Due to its capacity to influence expectations of individuals in organizations, organizational culture can contribute to fill this gap. To test if organizational culture influences the effectiveness of leadership style, we conducted two experimental studies using Amazon’s Mechanical Turk, comparing effects of paternalistic and transformational leadership on followers’ outcomes. Using video clips and vignettes, we found that PL is better related to followers´ outcomes in cultures oriented to people than outcome, and that TL has a better relationship in cultures oriented to innovation than stability. The results suggest that organizational culture helps in explaining PL endorsement, and that further analysis of the influence of this variable to PL can provide a better understanding of the expression of this leadership style in organizations.
Resumo:
Although cross-cultural leadership research has thrived in international business literature, little attention has been devoted to understanding the effectiveness of non-western theories beyond their original contexts. The purpose of this study is to examine the cross-cultural endorsement of paternalistic leadership, an emerging non-western leadership theory, using data from GLOBE project. Using multigroup confirmatory factor analyses we found measurement equivalence of a scale derived from GLOBE’s data, which enabled us to compare the endorsement of paternalistic leadership dimensions across 10 cultural clusters and 55 societies. Our study revealed that there are significant differences in the importance societies give to each dimension, suggesting that paternalism as leadership style is not universally nor homogeneously endorsed. Furthermore, results suggest that different patterns of endorsement of each of these dimensions give rise to idiosyncratic shades of paternalistic leadership across societies. Implications for theory and future research on international business are discussed.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components
Resumo:
The use of implant-supported prosthesis to replace missing teeth became a predictable treatment. Although high success rate has been reported, implant treatment is suitable to complications, failures, and limitations such as peri-implant bone loss after implant loading. Stress evaluation on the bone-abutment-implant interface has been carried out to develop new designs of prosthetic platform and to understand the stress distribution in this interface. Several types of prosthetic platforms are available such as external and internal hexagon, Morse cone connection, and the concept of platform switching. Therefore, this study aimed to critically describe the different options of prosthetic platforms in implant dentistry, by discussing their biomechanical concepts, clinical use, and advantages and disadvantages. It was observed that all types of prosthetic platforms provided high success rate of the implant treatment by following a strict criteria of indication and limitation. In conclusion, a reverse planning of implant treatment is strongly indicated to reduce implant overload, and the use of advanced surgical-prosthetic techniques is required to obtain a long-term success of oral rehabilitations.
Resumo:
\ The biologic width is an essential dental space that always needs to be maintained to ensure periodontal health in any dental prosthetic restorations. An iatrogenic partial fixed prosthesis constructed in lower posterior teeth predisposed the development of subgingival caries, which induced violation of the biologic width in involved teeth, resulting in an uncontrolled inflammatory process and periodontal tissue destruction. This clinical report describes a periodontal surgical technique to recover a violated biologic width in lower posterior teeth, by crown lengthening procedure associated with free gingival graft procedure, to ensure the possibility to place a modified partial fixed prosthesis in treated area. The procedure applied to recover the biologic width was crown lengthening with some modifications, associated with modified partial fixed prosthesis to achieve health in treated area. The modified techniques in both surgical and prosthetic procedures were applied to compensate the contraindications to recover biologic width by osteotomy in lower posterior teeth. The result, after 4 years under periodic control, seems to achieve the projected goal. Treating a dental diseased area is necessary to diagnose, eliminate, or control all etiologic factors involved in the process. When the traditional methods are not effective to recover destructed tissues, an alternative, compensatory, and adaptive procedure may be applied to restore the sequelae of the disease, applying a restorative method that respects the biology of involved tissues.
Resumo:
The misfit between prostheses and implants is a clinical reality, but the level that can be accepted without causing mechanical or biologic problem is not well defined. This study investigates the effect of different levels of unilateral angular misfit prostheses in the prosthesis/implant/retaining screw system and in the surrounding bone using finite element analysis. Four models of a two-dimensional finite element were constructed: group I (control), prosthesis that fit the implant; groups 2 to 4, prostheses with unilateral angular misfit of 50, 100, and 200 mu m, respectively. A load of 133 N was applied with a 30-degree angulation and off-axis at 2 mm from the long axis of the implant at the opposite direction of misfit on the models. Taking into account the increase of the angular misfit, the stress maps showed a gradual increase of prosthesis stress and uniform stress in the implant and trabecular bone. Concerning the displacement, an inclination of the system due to loading and misfit was observed. The decrease of the unilateral contact between prosthesis and implant leads to the displacement of the entire system, and distribution and magnitude alterations of the stress also occurred.
Resumo:
The prosthetic treatments play a role in the rehabilitation of patients with congenital and acquired cleft palate. To prepare the surgical field and/or correct inevitable sequelae of the surgery, the rehabilitation with obturator prosthesis is an auxiliary or complementary treatment to surgical treatments. In cases where the surgical treatment is contraindicated, the prosthetic rehabilitation becomes a definitive treatment. The denture is planned and fabricated according to each patient. Therefore, the aim of this study was to discuss the prosthetic rehabilitation performed in patients with oronasal communication.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796
Resumo:
The cementation procedure of metal-free fixed partial dentures exhibits special characteristics about the porcelains and cementation agents, which turns the correct association between these materials necessary. Our purpose in this literature review was to point the main groups of cements associated to metal-free restoration and discuss about the advantages, disadvantages, and recommendations of each one. Our search was confined to the electronic databases PubMed and SciELO and to books about this matter. There are essentially 3 types of hard cement: conventional, resin, or a hybrid of the two. The metal-free restorations can be fixed with conventional or resin cements. The right choice of luting material is of vital importance to the longevity of dental restorative materials. Conventional cements are advantageous when good compressive straight, good film thickness, and water dissolution resistance are necessary. However, they need an ideal preparation, and they are not acid dissolution resistant. Conventional cements are indicated to porcelains that cannot be acid etched. Resin cements represent the choice to metal-free restoration cementation because they present better physical properties and aesthetic than conventional agents.