798 resultados para polymer resins
Resumo:
Large amplitude oscillatory shear (LAOS) coupled with Fourier transform rheology (FTR) was used for the first time to characterize the large deformation behavior of selected bituminous binders at 20 C. Two polymer modified bitumens (PMB) containing recycled EVA and HDPE and two unmodified bitumens were tested with LAOS-FTR. The LAOS-FTR response of all binders was compared at same frequency, at same Deborah number (by tuning the frequency to the relaxation time of each binder) and at same phase shift angle d (by tuning the frequency to the one corresponding to d = 50 in the SAOS response of each sample). In all the approaches, LAOS-FTR results allowed to differentiate between all the nonlinear mechanical characteristics of the tested binders. All binders show LAOS-FTR patterns reminiscent from colloidal dispersions and emulsions. EVA PMB was less prone to strain-induced microstructural changes when compared to HDPE PMB which showed larger values of nonlinear FTR parameters for the range of shear strains tested in LAOS.
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2014
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2015
Resumo:
Perineural and intraneural fibrosis is thought to be the main cause of failure of the many surgical treatments of neuropathic pain. We have used Adcon-T/N carbohydrate polymer gel for prevention of perineural fibrosis in several parts of the body. In this retrospective study, 54 patients who presented with postoperative neuropathic pain had microsurgical epineural neurolysis and relocation of a terminal neuroma. In 19 of them, the carbohydrate gel was applied at the same time. The mean follow-up was four years and the nerve distribution varied. Postoperative improvement in pain scores (visual analogue scale (VAS) and neuropathic pain scale inventory (NPSI)), sensitivity, overall improvement and satisfaction were equivalent in the two groups, with pain relief in about 80% of the patients. There was no significant beneficial effect in the carbohydrate gel group. Patients treated with this device had a higher infection rate (21 compared with 0, p = 0.01) and delayed wound healing (31.6 compared with 11.8, p = 0.2). We conclude that good long-term pain relief is obtained postoperatively independently of the addition of carbohydrate gel. There was a slight but not significant trend towards profound pain relief with the gel.
Resumo:
Background: Acrylates and methacrylates (salts and esters of acrylic and metacrylic acid respectively), are monomers commonly found in polymer plastics, resins and glues, and are widely used in many industry sectors. The first adverse health effects described were skin reactions and asthma. Exposure to acrylates, for instance when using multicomponent glues, is now a well known cause of occupational asthma. Methods: We report the case of a rhinitis - and possible asthma - to acrylates, in a 38-year-old woman, working in a nail beauty salon. She was currently treated for hypertension, and otherwise known for obesity and seasonal rhinoconjunctivitis, but did not have any respiratory problem. Two years after starting this activity, she progressively started to complain of anosmia, rhinitis, and intermittent dyspnea. Her job consisted in decorating nails with a mixture of a polymer powder and a liquid monomer, after removing the previous artificial nail with a small sander. We assessed exposure to acrylates at her working place, both as dust (from sanded nails) and volatile compound (from the mixture described above), and she was asked to measure her peak flow values twice a day for ten days, in order to detect a possible relationship between her occupational activities, the symptoms and the peak flow values. Results: Measures made during the visit of the patient's place of work showed that the existing aspiration system was efficient for eliminating the dust produced by nail sanding, but not for eliminating the volatile components. Thus, occupational exposure to acrylates was demonstrated. Moreover, the peak flow measures showed an average decrease of almost 10 percent when the patient was at work, compared to when she stayed home. We concluded that she actually suffered from professional rhinitis and, possibly, professional asthma (not certain because of the limited number of peak flow measures per day). Conclusion: Although exposure to acrylates is a well known cause of occupational asthma, it should be emphasized that the exact mechanisms of action remain unknown, despite the abundant literature about it. Some professions, which tend to be more frequent nowadays (such as working in a nail beauty salon), can expose the worker to particular risks. This highlights the need of always inquiring not only about the profession, but also the related activities, when facing a case of suspected asthma.
Resumo:
Static incubation tests, where microcapsules and beads are contacted with polymer and protein solutions, have been developed for the characterization of permselective materials applied for bioartificial organs and drug delivery. A combination of polymer ingress, detected by size-exclusion chromatography, and protein ingress/ egress, assessed by gel electrophoresis, provides information regarding the diffusion kinetics, molar mass cutoff(MMCO) and permeability. This represents an improvement over existing permeability measurements that are based on the diffusion of a single type of solute. Specifically, the permeability of capsules based on alginate, cellulose sulfate, polymethylene-co-guanidine were characterized as a function of membrane thickness. Solid alginate beads were also evaluated. The MMCO of these capsules was estimated to be between 80 and 90 kDa using polymers, and between 116-150 kDa with proteins. Apparently, the globular shape of the proteins (radius of gyration (Rg) of 4.2-4.6 nm) facilitates their passage through the membrane, comparatively to the polysaccharide coil conformation (Rg of 6.5-8.3 nm). An increase of the capsule membrane thickness reduced these values. The MMCO of the beads, which do not have a membrane limiting their permselective properties, was higher, between 110 and 200 kDa with dextrans, and between 150 and 220 kDa with proteins. Therefore, although the permeability estimated with biologically relevant molecules is generally higher due to their lower radius of gyration, both the MMCO of synthetic and natural watersoluble polymers correlate well, and can be used as in vitro metrics for the immune protection ability of microcapsules and microbeads. This article shows, to the authors' knowledge, the first reported concordance between permeability measures based on model natural and biological macromolecules.
Resumo:
BACKGROUND: carbon nanotubes (CNT) can have adverse effects on health. Therefore, minimizing the risk associated with CNT exposure is of crucial importance. The aim of this work was to evaluate if coating multi-walled CNT (MWCNT) with polymers could modify their toxicity, thus representing a useful strategy to decrease adverse health effects of CNT. We used industrially-produced MWCNT uncoated (NT1) or coated (50/50 wt%) with acid-based (NT2) or polystyrene-based (NT3) polymer, and exposed murine macrophages (RAW 264.7 cell line) or Balb/c mice by intratracheal administration. Biological experiments were performed both in vitro and in vivo, examining time- and dose-dependent effects of CNT, in terms of cytotoxicity, expression of genes and proteins related to oxidative stress, inflammation and tissue remodeling, cell and lung tissue morphology (optical and transmission electron microscopy), and bronchoalveolar lavage fluid content analysis.RESULTS: extensive physico-chemical characterization of MWCNT was performed, and showed, although similar dimensions for the 3 MWCNT, a much smaller specific surface area for NT2 and NT3 as compared to NT1 (54.1, 34 and 227.54 m(2)/g respectively), along with different surface characteristics. MWCNT-induced cytotoxicity, oxidative stress, and inflammation were increased by acid-based and decreased by polystyrene-based polymer coating both in vitro in murine macrophages and in vivo in lung of mice monitored for 6 months.CONCLUSIONS: these results demonstrate that coating CNT with polymers, without affecting their intrinsic structure, may constitute a useful strategy for decreasing CNT toxicity, and may hold promise for improving occupational safety and that of general the user.
Resumo:
Using numerical simulations we investigate shapes of random equilateral open and closed chains, one of the simplest models of freely fluctuating polymers in a solution. We are interested in the 3D density distribution of the modeled polymers where the polymers have been aligned with respect to their three principal axes of inertia. This type of approach was pioneered by Theodorou and Suter in 1985. While individual configurations of the modeled polymers are almost always nonsymmetric, the approach of Theodorou and Suter results in cumulative shapes that are highly symmetric. By taking advantage of asymmetries within the individual configurations, we modify the procedure of aligning independent configurations in a way that shows their asymmetry. This approach reveals, for example, that the 3D density distribution for linear polymers has a bean shape predicted theoretically by Kuhn. The symmetry-breaking approach reveals complementary information to the traditional, symmetrical, 3D density distributions originally introduced by Theodorou and Suter.
Resumo:
Aquest projecte de doctorat és un treball interdisciplinari adreçat a l’obtenció de nous nanocompòsits (NCs) funcionals sintetitzats a partir de materials polimèrics bescanviadors d’ions que són modificats amb nanopartícules metàl•liques (NPMs) de diferent composició. Els materials desenvolupats s’avaluen en funció de dues possibles aplicacions: 1) com a catalitzadors de reaccions orgàniques d’interès actual (NCs basats en pal•ladi) i, 2) la seva dedicació a aplicacions bactericides en el tractament d’aigües domèstiques o industrials (NCs basats en plata). El desenvolupament de nanomaterials és de gran interès a l’actualitat donades les seves especials propietats, l’aprofitament de les quals és la força impulsora per a la fabricació de nous NCs. Les nanopartícules metàl•liques estabilitzades en polímer (Polymer Stabilized Metal Nanoparticles, PSNPM) s’han preparat mitjançant la tècnica in-situ de síntesi intermatricial (Inter-matrix synthesis, IMS) que consisteix en la càrrega seqüencial dels grups funcionals de les matrius polimèriques amb ions metàl•lics, i la seva posterior reducció química dins de la matriu polimèrica de bescanvi iònic. L’estabilització en matrius polimèriques evita l’agregació entre elles (self-aggreagtion), un dels principals problemes coneguts de les NPs. Pel desenvolupament d’aquesta metodologia, s’han emprat diferents tipus de matrius polimèriques de bescanvi iònic: membrana Sulfonated PolyEtherEtherKetone, SPEEK, així com fibres sintètiques basades en polypropilè amb diferents tipus de grups funcionals, que ens permeten el seu ús com a filtres en la desinfecció de solucions aquoses o com a material catalitzador. Durant el projecte s’ha anat avançant en l’optimització del material nanocomposite final per a les aplicacions d’interès, en quant activitat i funcionalitat de les nanopartícules i estabilitat del nanocomposite. Així, s’ha optimitzat la síntesi de NPs estabilitzades en resines de bescanvi iònic, realitzant un screening de diferents tipus de resines i la seva avaluació en aplicacions industrials d’interès.
Resumo:
BACKGROUND It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.
Resumo:
Epoxidization is an interesting way to develop a new application of lignin and therefore to improve its application potential. In this work, kraft lignin-based epoxy resins were obtained by the epoxidization reaction, using the kraft lignin recovered directly from pulping liquor and modified by a methylolation reaction. The methylolated lignins were obtained by the reaction of original kraft lignin with formaldehyde and glyoxal, which is a less volatile and less toxic aldehyde. 1H-NMR spectroscopy showed that methylolated kraft lignin has more hydroxymethyl groups than glyoxalated kraft lignin. For the epoxidization reaction we studied the influence of the lignin:NaOH (w/w) ratio, temperature, and time of the reaction on the properties of the prepared epoxidized lignins. The structures of lignin-based epoxy resins were followed by epoxy index test and FTIR spectroscopy. Optimal conditions were obtained for lignin-based epoxy resin produced at lignin/NaOH = 1/3 at 70 ºC for 3h. Thermogravimetry analysis (TGA) revealed that the epoxidization enhances the thermal stability of lignins and may allow a wider temperature range for applications with lignin epoxy-PF blends