688 resultados para pedicle screw
Resumo:
Bisphosphonates are known for their strong inhibitory effect on bone resorption. Their influence on bone formation however is less clear. In this study we investigated the spatio-temporal effect of locally delivered Zoledronate on peri-implant bone formation and resorption in an ovariectomized rat femoral model. A cross-linked hyaluronic acid hydrogel was loaded with the drug and applied bilaterally in predrilled holes before inserting polymer screws. Static and dynamic bone parameters were analyzed based on in vivo microCT scans performed first weekly and then biweekly. The results showed that the locally released Zoledronate boosted bone formation rate up to 100% during the first 17 days after implantation and reduced the bone resorption rate up to 1000% later on. This shift in bone remodeling resulted in an increase in bone volume fraction (BV/TV) by 300% close to the screw and 100% further away. The double effect on bone formation and resorption indicates a great potential of Zoledronate-loaded hydrogel for enhancement of peri-implant bone volume which is directly linked to improved implant fixation.
Resumo:
BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.
Resumo:
The glomus tumor is a rare, benign, but painful vascular neoplasm arising from the neuromyoarterial glomus. Primary intraosseous glomus tumor is even rarer, with only about 20 cases reported in the literature so far, 5 of which involved the spine. Surgical resection is currently considered the treatment of choice. We herewith present an uncommon case of primary intraosseous spinal glomus tumor involving the right pedicle of the eleventh thoracic vertebra (T11). To our knowledge, this is the first case of primary intraosseous spinal glomus tumor successfully treated by percutaneous CT-guided radiofrequency ablation (RFA).
Resumo:
Centromedullary nailing is a well-established method of treatment for diaphyseal long bone fractures. The indications have been broadened greatly since the introduction in 1974 of interlocking centromedullary nailing. The purpose of this paper is to review our first results with locked intramedullary nailing of the tibia. We report our experience with the first 19 cases of interlocking tibia nails (15 fractures, 1 delayed union, 2 pseudarthrosis, 1 osteotomy). On the extension table, the insertion of the nail and the placement of the interlocking screws did not cause any problem. In 3 cases, a proximal screw had to be removed within two weeks because of spontaneous displacement. Complications have been noticed in three patients (15.8%) (pulmonary embolism on day 1, and compartment syndrome two days later in one case, sciatic nerve neuroapraxia in the other two). The other patients have been mobilized 24 to 48 hours after surgery. 94% of the fractures were consolidated 4 months post-operatively, with no major deformation. Interlocking tibia nailing seems to be an attractive method in the treatment of certain fractures of the tibia. Early mobilisation and weight-bearing are provided. The indications, the technical aspects as well as the dangers of the method must be carefully respected in order to avoid complications and poor results.
Resumo:
Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.
Resumo:
RATIONALE The choice of containers for storage of aqueous samples between their collection, transport and water hydrogen (2H) and oxygen (18O) stable isotope analysis is a topic of concern for a wide range of fields in environmental, geological, biomedical, food, and forensic sciences. The transport and separation of water molecules during water vapor or liquid uptake by sorption or solution and the diffusive transport of water molecules through organic polymer material by permeation or pervaporation may entail an isotopic fractionation. An experiment was conducted to evaluate the extent of such fractionation. METHODS Sixteen bottle-like containers of eleven different organic polymers, including low and high density polyethylene (LDPE and HDPE), polypropylene (PP), polycarbonate (PC), polyethylene terephthalate (PET), and perfluoroalkoxy-Teflon (PFA), of different wall thickness and size were completely filled with the same mineral water and stored for 659?days under the same conditions of temperature and humidity. Particular care was exercised to keep the bottles tightly closed and prevent loss of water vapor through the seals. RESULTS Changes of up to +5 parts per thousand for d2H values and +2.0 parts per thousand for d18O values were measured for water after more than 1?year of storage within a plastic container, with the magnitude of change depending mainly on the type of organic polymer, wall thickness, and container size. The most important variations were measured for the PET and PC bottles. Waters stored in glass bottles with Polyseal (TM) cone-lined PP screw caps and thick-walled HDPE or PFA containers with linerless screw caps having an integrally molded inner sealing ring preserved their original d2H and d18O values. The carbon, hydrogen, and oxygen stable isotope compositions of the organic polymeric materials were also determined. CONCLUSIONS The results of this study clearly show that for precise and accurate measurements of the water stable isotope composition in aqueous solutions, rigorous sampling and storage procedures are needed both for laboratory standards and for unknown samples. Copyright (c) 2012 John Wiley & Sons, Ltd.
Resumo:
The free extended lateral arm flap (ELAF) has gained increasing popularity thank to its slimness and versatility, longer neurovascular pedicle, and greater flap size when compared with the original flap design. The aim of this study was to assess the donor-site morbidity associated with this extended procedure. A retrospective study of 25 consecutive patients analyzing postoperative complications using a visual analogue scale questionnaire revealed high patients satisfaction and negligible donor-site morbidity of the ELAF. Scar visibility was the commonest negative outcome. Impaired mobility of the elbow had the highest correlation with patient dissatisfaction. Sensory deficits or paresthetic disorders did not affect patient satisfaction. The extension of the lateral arm flap and positioning over the lateral humeral epicondyle is a safe and well-accepted procedure with minimal donor-site morbidity. To optimize outcomes, a maximal flap width of 6 or 7 cm and intensive postoperative mobilization therapy is advisable.
Resumo:
OBJECTIVE: To evaluate the results of closed and open grade I and II tibial shaft fractures treated by reamed nail and unreamed nailing. SUBJECTS AND METHODS: Between 1997 and 2000, 119 patients with tibial shaft fractures were treated with reamed tibial nails. Postoperatively 96 patients (70 closed and 26 grade I and II open fractures) were followed clinically and radiologically for up to 18 months. The nail was inserted either by patellar tendon splitting or by nonsplitting technique. The nail was inserted after overreaming by 1.5 mm. Postoperatively, patients with isolated tibial fracture were mobilized by permitting partial weight bearing on the injured leg for 6 weeks. Patients with associated ankle fractures were allowed to walk with a Sarmiento cast. RESULTS: Postoperatively, 6 (6.3%) patients developed a compartment syndrome after surgery. In 48 (50%) cases, dynamization of the nail was carried out after a mean period of 12 weeks for delayed union. Overall, a 90.6% union was obtained at a mean of 24 weeks without difference between closed or open fractures. Two (2.1%) patients with an open grade II fracture developed a deep infection requiring treatment. A 9.4% rate of malunion was observed. Eight (8.3%) patients developed screw failure without clinical consequences. At the last follow-up, 52% of patients with patellar tendon splitting had anterior knee pain, compared to those (14%) who did not have tendon splitting. CONCLUSION: Reamed intramedullary nail is a suitable implant in treating closed as well as grade I and II open tibial shaft fractures.
Resumo:
OBJECTIVES: To evaluate the results of retrograde percutaneous screw fixation (PSF) in minimally or undisplaced acetabular fractures in a geriatric population. PATIENTS AND METHODS: Between July 1998 and July 2001, 21 consecutive patients with an acetabular fracture underwent fluoroscopic guided percutaneous fixation. The mean age was 81 years (range 67--90 years). In all cases, the fracture was minimally or undisplaced (<2mm). Two cannulated cancellous 7.3mm screws were inserted in a retrograde fashion to stabilise the posterior and the anterior column. Bed to chair transfer began after 24h. Weight bearing as tolerated was allowed at 4 weeks. RESULTS: Eighteen patients were reviewed at a mean of 3.5 years (range 2--5 years). Soft tissue dissection was minimal. There were no intraoperative or postoperative complications. At the latest follow-up there was no radiographical evidence of secondary displacement of fragments, degenerative changes, or screw failure. Fractures healed at a mean time of 12 weeks (range 8--15 weeks). Clinical results were satisfactory in 17 patients. CONCLUSION: Our results show that percutaneous screw fixation under fluoroscopic control is a safe technique to treat some pattern of acetabular fracture.
Resumo:
The glomus tumor is a rare, benign, but painful vascular neoplasm arising from the neuromyoarterial glomus. Primary intraosseous glomus tumor is even rarer, with only about 20 cases reported in the literature so far, 5 of which involved the spine. Surgical resection is currently considered the treatment of choice. We herewith present an uncommon case of primary intraosseous spinal glomus tumor involving the right pedicle of the eleventh thoracic vertebra (T11). To our knowledge, this is the first case of primary intraosseous spinal glomus tumor successfully treated by percutaneous CT-guided radiofrequency ablation (RFA).
Resumo:
STUDY DESIGN: Computed tomography-based anatomical study. OBJECTIVE: To study the secular changes in lumbar spinal canal dimensions. SUMMARY OF BACKGROUND DATA: Development of symptomatic lumbar spinal stenosis, among other factors, is related to the dimensions of the bony canal. The canal reaches its adult size early on in life. Several factors, including protein intake, may influence its final dimensions. As with increases in human stature from improvements of socioeconomic conditions, we hypothesized that adult bony canal size has also grown larger in recent generations. METHODS: This study analyzes computed tomographic reconstructions from 184 subjects performed for either trauma (n = 81) or abdominal pathologies (n = 103) and born either between 1940 and 1949 (n = 88) or 1970 and 1979 (n = 96). The cross-sectional area of the bony canal was digitally measured at the level of the pedicle (i.e., at a level not influenced by degenerative changes) for each lumbar vertebra. Intra- and interobserver reliability was assessed. RESULTS: Intra- and interobserver measurement reliability were excellent (interclass correlation coefficient = 0.87) and good (interclass correlation coefficient = 0.61), respectively. Contrary to our hypothesis, the 1940-1949 generation patient group exhibited larger lumbar canals at all levels as compared with the 1970-1979 group. Statistically this difference was highly significant (P < 0.001) and particularly pronounced in the trauma subgroup. CONCLUSION: Given that human stature evolution has stabilized and adult height is established during the first 2 years of long bone growth, it is possible that antenatal factors are responsible for this surprising finding. Maternal smoking and age may be possible explanations. This finding may have significant implications. An increasing number of patients may emerge with lumbar spinal stenosis as degenerative changes develop, putting a strain on health resources. Further studies in different population groups and countries will be important to further confirm this trend. LEVEL OF EVIDENCE: 3.
Resumo:
The gracilis free flap is a workhorse in plastic surgery. We present a modified technique that relies on a single horizontal thigh-lift-type approach, which (1) gives wide pedicle exposure, (2) provides material for skin grafting, and (3) allows for distal flap transection without an additional incision. Eighteen gracilis free flaps were performed from 2007 to 2009 for lower extremity reconstruction. Complete flap survival was observed in 17 patients with one partial necrosis distally. Our approach allowed access to divide the distal gracilis tendon without a second incision in all cases. The mean scar length was 16 ± 3 cm and no hypertrophic scars were observed. In 15 patients, no visible scar was observed in the upright position, and in three patients, the scar was visible dorsally (2 ± 1 cm). No sensory deficits were observed 6 months postoperatively. In addition, the split-thickness skin graft harvested from the skin paddle was sufficient to cover all defects.
Resumo:
Taking as its point of departure recent insights about the performative¦nature of genre, The Poetics and Politics of the American Gothic¦challenges the critical tendency to accept at face value that gothic¦literature is mainly about fear. Instead, Agnieszka Soltysik Monnet¦argues that the American Gothic, and gothic literature in general,¦is also about judgment: how to judge and what happens when¦judgment is confronted with situations that defy its limits.¦Poe, Hawthorne, Melville, Gilman, and James all shared a concern¦with the political and ideological debates of their time, but tended¦to approach these debates indirectly. Thus, Monnet suggests, while¦slavery and race are not the explicit subject matter of antebellum¦works by Poe and Hawthorne, they nevertheless permeate it through¦suggestive analogies and tacit references. Similarly, Melville, Gilman,¦and James use the gothic to explore the categories of gender and¦sexuality that were being renegotiated during the latter half of the¦century. Focusing on The Fall of the House of Usher, The Marble¦Faun, Pierre, The Turn of the Screw, and The Yellow Wallpaper,¦Monnet brings to bear minor texts by the same authors that further¦enrich her innovative readings of these canonical works. At the same¦time, her study persuasively argues that the Gothic's endurance¦and ubiquity are in large part related to its being uniquely adapted¦to rehearse questions about judgment and justice that continue to¦fascinate and disturb.
Resumo:
OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."
Resumo:
A clear and rigorous definition of muscle moment-arms in the context of musculoskeletal systems modelling is presented, using classical mechanics and screw theory. The definition provides an alternative to the tendon excursion method, which can lead to incorrect moment-arms if used inappropriately due to its dependency on the choice of joint coordinates. The definition of moment-arms, and the presented construction method, apply to musculoskeletal models in which the bones are modelled as rigid bodies, the joints are modelled as ideal mechanical joints and the muscles are modelled as massless, frictionless cables wrapping over the bony protrusions, approximated using geometric surfaces. In this context, the definition is independent of any coordinate choice. It is then used to solve a muscle-force estimation problem for a simple 2D conceptual model and compared with an incorrect application of the tendon excursion method. The relative errors between the two solutions vary between 0% and 100%.