840 resultados para operational reliability
Resumo:
OBJECTIVE: The purpose of this study was to examine the reliability and the convergent validity of the Children Anxiety Sensitivity Index (CASI) with DSM-IV anxiety disorder symptoms, by comparison with the Screen for Child Anxiety Related Emotional Disorders (SCARED), in a community sample of Brazilian children and adolescents. METHODS: Children and adolescents from five schools were selected from a larger study that aimed to assess different aspects of childhood anxiety disorders. All participants completed the CASI and the SCARED. RESULTS: This study supported the reliability of the CASI total score. Girls reported higher total anxiety sensitivity scores than boys and there were no differences in total anxiety sensitivity scores between children and adolescents. This study showed moderate to high correlations between the CASI scores with SCARED scores, all correlations coefficients being positive and significant. CONCLUSIONS: Our findings demonstrate an appropriate reliability and evidence of convergent validity in the CASI in a sample of Brazilian children and adolescents.
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.
Resumo:
OBJECTIVE: To assess the intraobserver reliability of the information about the history of diagnosis and treatment of hypertension. METHODS: A multidimensional health questionnaire, which was filled out by the interviewees, was applied twice with an interval of 2 weeks, in July '99, to 192 employees of the University of the State of Rio de Janeiro (UERJ), stratified by sex, age, and educational level. The intraobserver reliability of the answers provided was estimated by the kappa statistic and by the coefficient of intraclass correlation (CICC). RESULTS: The general kappa (k) statistic was 0.75 (95% CI=0.73-0.77). Reliability was higher among females (k=0.88, 95% CI=0.85-0.91) than among males (k=0.62, 95% CI=0.59-0.65).The reliability was higher among individuals 40 years of age or older (k=0.79; 95% CI=0.73-0.84) than those from 18 to 39 years (k=0.52; 95% CI=0.45-0.57). Finally, the kappa statistic was higher among individuals with a university educational level (k=0.86; 95% CI=0.81-0.91) than among those with high school educational level (k=0.61; 95% CI=0.53-0.70) or those with middle school educational level (k=0.68; 95% CI=0.64-0.72). The coefficient of intraclass correlation estimated by the intraobserver agreement in regard to age at the time of the diagnosis of hypertension was 0.74. A perfect agreement between the 2 answers (k=1.00) was observed for 22 interviewees who reported prior prescription of antihypertensive medication. CONCLUSION: In the population studied, estimates of the reliability of the history of medical diagnosis of hypertension and its treatment ranged from substantial to almost perfect reliability.
Resumo:
Background: The Neonatal Behavioral Assessment Scale (NBAS, Brazelton & Nugent, 1995) is an instrument conceived to observe the neonatal neurobehavior. Data analysis is usually performed by organizing items into groups. The most widely used data reduction for the NBAS was developed by Lester, Als, and Brazelton (1982). Objective: Examine the psychometric properties of the NBAS items in a sample of 213 Portuguese infants. Method: The NBAS was performed in the first week of infant life (3 days±2) and in the seventh week of life (52 days±5). Results: Principal component analyses yielded a solution of four components explaining 55.13% of total variance. Construct validity was supported by better neurobehavioral performance of 7-week-old infants compared with 1-week-old infants. Conclusion: Changes in the NBAS structure for the Portuguese sample are suggested compared to Lester factors in order to reach better internal consistency of the scale.
Resumo:
Dissertação de mestrado integrado em Engenharia e Gestão Industrial
Resumo:
Dissertação de mestrado em Bioengenharia
The appraisal of anaerobic digestion in Ireland to develop improved designs and operational practice
Resumo:
Mesophilic Anaerobic Digestion treating sewage sludge was investigated at five full-scale sewage treatment plants in Ireland. The anaerobic digestion plants are compared and evaluated in terms of design, equipment, operation, monitoring and management. All digesters are cylindrical, gas mixed and heated Continuously Stirred Tank Reactors (CSTR), varying in size from 130m3 to 800m3. Heat exchanger systems heat all digesters. Three plants reported difficulties with the heating systems ranging from blockages to insufficient insulation and design. Exchangers were modified and replaced within one year of operation at two plants. All but one plant had Combined Heat and Power (CHP) systems installed. Parameter monitoring is a problem at all plants mainly due to a lack of staff and knowledge. The plant operators consider pH and temperature the most important parameters to be measured in terms of successful monitoring of an anaerobic digester. The short time taken and the ease at which pH and temperature can be measured may favour these parameters. Three laboratory scale pilot anaerobic digesters were operated using a variety of feeds over at 144-day period. Two of the pilots were unmixed and the third was mechanically mixed. As expected the unmixed reactors removed more COD by retention of solids in the digesters but also produced greater quantities of biogas than the mixed digester, especially when low solids feed such as whey was used. The mixed digester broke down more solids due to the superior contact between the substrate and the biomass. All three reactors showed good performance results for whey and sewage solids. Scum formation occurred giving operational problems for mixed and unmixed reactors when cattle slurry was used as the main feed source. The pilot test was also used to investigate which parameters were the best indicators of process instability. These trials clearly indicated that total Volatile Fatty Acid (VFA) concentrations was the best parameter to show signs of early process imbalance, while methane composition in the biogas was good to indicate possible nutrient deficiencies in the feed and oxygen shocks. pH was found to be a good process parameter only if the wastewater being treated produced low bicarbonate alkalinities during treatment.
Resumo:
The research described in this thesis has been developed as a part of the Reliability and Field Data Management for Multi-component Products (REFIDAM) Project. This project was founded under the Applied Research Grants Scheme administered by Enterprise Ireland. The project was a partnership between Galway-Mayo Institute of Technology and Thermo King Europe. The project aimed to develop a system in order to manage the information required for reliability assessment and improvement of multi-component products, by establishing information flows within the company and information exchange with fleet users.
Resumo:
Abstract Background: Studies have shown the impact of atrial fibrillation (AF) on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1), which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2), which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36) to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC). Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40) had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.
Resumo:
BACKGROUND: The WOSI (Western Ontario Shoulder Instability Index) is a self-administered quality of life questionnaire designed to be used as a primary outcome measure in clinical trials on shoulder instability, as well as to measure the effect of an intervention on any particular patient. It is validated and is reliable and sensitive. As it is designed to measure subjective outcome, it is important that translation should be methodologically rigorous, as it is subject to both linguistic and cultural interpretation. OBJECTIVE: To produce a French language version of the WOSI that is culturally adapted to both European and North American French-speaking populations. MATERIALS AND METHODS: A validated protocol was used to create a French language WOSI questionnaire (WOSI-Fr) that would be culturally acceptable for both European and North American French-speaking populations. Reliability and responsiveness analyses were carried out, and the WOSI-Fr was compared to the F-QuickDASH-D/S (Disability of the Arm, Shoulder and Hand-French translation), and Walch-Duplay scores. RESULTS: A French language version of the WOSI (WOSI-Fr) was accepted by a multinational committee. The WOSI-Fr was then validated using a total of 144 native French-speaking subjects from Canada and Switzerland. Comparison of results on two WOSI-Fr questionnaires completed at a mean interval of 16 days showed that the WOSI-Fr had strong reliability, with a Pearson and interclass correlation of r=0.85 (P=0.01) and ICC=0.84 [95% CI=0.78-0.88]. Responsiveness, at a mean 378.9 days after surgical intervention, showed strong correlation with that of the F-QuickDASH-D/S, with r=0.67 (P<0.01). Moreover, a standardized response means analysis to calculate effect size for both the WOSI-Fr and the F-QuickDASH-D/S showed that the WOSI-Fr had a significantly greater ability to detect change (SRM 1.55 versus 0.87 for the WOSI-Fr and F-QuickDASH-D/S respectively, P<0.01). The WOSI-Fr showed fair correlation with the Walch-Duplay. DISCUSSION: A French-language translation of the WOSI questionnaire was created and validated for use in both Canadian and Swiss French-speaking populations. This questionnaire will facilitate outcome assessment in French-speaking settings, collaboration in multinational studies and comparison between studies performed in different countries. TYPE OF STUDY: Multicenter cohort study. LEVEL OF EVIDENCE: II.
Resumo:
In order to upgrade the reliability of xenodiagnosis, attention has been directed towards population dynamics of the parasite, with particular interest for the following factors: 1. Parasite density which by itself is not a research objective, but by giving an accurate portrayal of parasite development and multiplication, has been incorporated in screening of bugs for xenodiagnosis. 2. On the assumption that food availability might increase parasite density, bugs from xenodiagnosis have been refed at biweekly intervals on chicken blood. 3. Infectivity rates and positives harbouring large parasite yields were based on gut infections, in which the parasite population comprised of all developmental forms was more abundant and easier to detect than in fecal infections, thus minimizing the probability of recording false negatives. 4. Since parasite density, low in the first 15 days of infection, increases rapidly in the following 30 days, the interval of 45 days has been adopted for routine examination of bugs from xenodiagnosis. By following the enumerated measures, all aiming to reduce false negative cases, we are getting closer to a reliable xenodiagnostic procedure. Upgrading the efficacy of xenodiagnosis is also dependent on the xenodiagnostic agent. Of 9 investigated vector species, Panstrongylus megistus deserves top priority as a xenodiagnostic agent. Its extraordinary capability to support fast development and vigorous multiplication of the few parasites, ingested from the host with chronic Chagas' disease, has been revealed by the strikingly close infectivity rates of 91.2% vs. 96.4% among bugs engorged from the same host in the chronic and acute phase of the disease respectively (Table V), the latter comporting an estimated number of 12.3 x 10[raised to the power of 3] parasites in the circulation at the time of xenodiagnosis, as reported previously by the authors (1982).
Resumo:
The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.
Resumo:
Technical progress lowers costs and prices but appears to have an ambiguous effect on product reliabilty. This paper presents a simple model which explains this observation.
Resumo:
OBJECTIVES: Advances in biopsychosocial science have underlined the importance of taking social history and life course perspective into consideration in primary care. For both clinical and research purposes, this study aims to develop and validate a standardised instrument measuring both material and social deprivation at an individual level. METHODS: We identified relevant potential questions regarding deprivation using a systematic review, structured interviews, focus group interviews and a think-aloud approach. Item response theory analysis was then used to reduce the length of the 38-item questionnaire and derive the deprivation in primary care questionnaire (DiPCare-Q) index using data obtained from a random sample of 200 patients during their planned visits to an ambulatory general internal medicine clinic. Patients completed the questionnaire a second time over the phone 3 days later to enable us to assess reliability. Content validity of the DiPCare-Q was then assessed by 17 general practitioners. Psychometric properties and validity of the final instrument were investigated in a second set of patients. The DiPCare-Q was administered to a random sample of 1898 patients attending one of 47 different private primary care practices in western Switzerland along with questions on subjective social status, education, source of income, welfare status and subjective poverty. RESULTS: Deprivation was defined in three distinct dimensions: material (eight items), social (five items) and health deprivation (three items). Item consistency was high in both the derivation (Kuder-Richardson Formula 20 (KR20) =0.827) and the validation set (KR20 =0.778). The DiPCare-Q index was reliable (interclass correlation coefficients=0.847) and was correlated to subjective social status (r(s)=-0.539). CONCLUSION: The DiPCare-Q is a rapid, reliable and validated instrument that may prove useful for measuring both material and social deprivation in primary care.