928 resultados para moisture sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is directed to the study and evaluation of gas diffusion electrodes as detectors in hydrogen sensors. Electrochemical experiments were carried out with rotating disk electrodes with a thin porous coating of the catalyst as a previous step to select useful parameters for the sensor. An experimental arrangement made in the laboratory that simulates the sensor was found appropriate to detect volumetric hydrogen percentages above 0.25% in mixtures H2:N2. The system shows a linear response for volumetric percentages of hydrogen between 0.25 and 2 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the work eddy current sensors are described and evaluated. Theoretical part includes physical basics of the eddy currents, overview of available commercial products and technologies. Industrial sensors operation was assessed based on several working modes. Apart from this, the model was created in Matlab Simulink with Xilinx Blockset and then translated into a Xilinx ISE Design Suite compatible project. The performance of the resulting implementation was compared to the existing implementation in the Xilinx Spartan 3 FPGA board with the custom made sensor. Additionally, an introduction to FPGAs and VHDL is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The understanding of unsaturated soil water flow at process-level is essential to develop proper management actions for environmental protection in agricultural systems. One important tool for simulation of soil water flow that has been used worldwide is the SWAP model. The aim of this work was to test and to calibrate the SWAP model by inverse modeling to describe moisture profiles in a Brazilian very clayey Latossol in Dourados, State of Mato Grosso do Sul, Brazil. The SWAP model was tested in an experimental field of 0.09 ha cultivated with soybean and soil profiles were sampled eight times between December 2006 and October 2007. The SWAP input values (i.e. soil water retention curves and meteorological data) were based on in-situ measurements. Simulations with uncalibrated soil water retention curves resulted in moisture profiles that were too wet for almost all sampling dates, in particular between 0-10 cm depth. After calibration of soil water retention curves, there was a good improvement in the simulated moisture profiles, which were within the range of measured values for almost all depths and sampling dates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of new methodologies and tools that enable to determine the water content in soil is of fundamental importance to the practice of irrigation. The objective of this study was to evaluate soil matric potential using mercury tensiometer and puncture digital tensiometer, and to compare the gravimetric soil moisture values obtained by tensiometric system with gravimetric soil moisture obtained by neutron attenuation technique. Four experimental plots were maintained with different soil moisture by irrigation. Three repetitions of each type of tensiometer were installed at 0.20 m depth. Based on the soil matric potential and the soil water retention curve, the corresponding gravimetric soil moisture was determined. The data was then compared to those obtained by neutron attenuation technique. The results showed that both tensiometric methods showed no difference under soil matric potential higher than -40 kPa. However, under drier soil, when the water was replaced by irrigation, the soil matric potential of the puncture digital tensiometer was less than those of the mercury tensiometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was evaluated the effect of irrigation management on the production characteristics of coffee cultivar Acaiá MG-1474, planted in spacing of 3.00 m x 0.60 m, pruned in 2004, and irrigated by drip since the planting, in 1997. The experimental designed used was of randomized blocks with five treatments and four replications. The treatments consisted of irrigation management strategies, applying or not applying controlled moisture deficit in layer of 0 to 0.4m, in dry seasons of the year: A = no irrigation (control), B = irrigation during all year considering the factor of water availability in the soil (f) equal to 0.75, C = irrigation during all year considering f = 0.25, D = irrigation during all year, but in January /February /March /July /October /November /December with f = 0.25 and April /May /June /August /September with f = 0.75, E = irrigation only during April /May /June /August /September with f = 0.25. From July /2005 to June /2007 the applied water depth was defined based on Class A pan evaporation (ECA) and the period from July/2007 to June/2008 based on readings of matric potential of soil obtained from Watermark® sensors. Each plot consisted of three rows with ten plants per row, considering as useful plot five plants of center line. The results indicated that the E irrigation management was the most suitable for technical reasons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potentiometric ion sensors are a very important subgroup of electrochemical sensors, very attractive for practical applications due to their small size, portability, low-energy consumption, relatively low cost and not changing the sample composition. They are investigated by the researchers from many fields of science. The continuous development of this field creates the necessity for a detailed description of sensor response and the electrochemical processes important in the practical applications of ion sensors. The aim of this thesis is to present the existing models available for the description of potentiometric ion sensors as well as their applicability and limitations. This includes the description of the diffusion potential occurring at the reference electrodes. The wide range of existing models, from most idealised phase boundary models to most general models, including migration, is discussed. This work concentrates on the advanced modelling of ion sensors, namely the Nernst-Planck-Poisson (NPP) model, which is the most general of the presented models, therefore the most widely applicable. It allows the modelling of the transport processes occurring in ion sensors and generating the potentiometric response. Details of the solution of the NPP model (including the numerical methods used) are shown. The comparisons between NPP and the more idealized models are presented. The applicability of the model to describe the formation of diffusion potential in reference electrode, the lower detection limit of both ion-exchanger and neutral carrier electrodes and the effect of the complexation in the membrane are discussed. The model was applied for the description of both types of electrodes, i.e. with the inner filling solution and solidcontact electrodes. The NPP model allows the electrochemical methods other than potentiometry to be described. Application of this model in Electrochemical Impedance Spectroscopy is discussed and a possible use in chrono-potentiometry is indicated. By combining the NPP model with evolutionary algorithms, namely Hierarchical Genetic Strategy (HGS), a novel method allowing the facilitation of the design of ion sensors was created. It is described in detail in this thesis and its possible applications in the field of ion sensors are indicated. Finally, some interesting effects occurring in the ion sensors (i.e. overshot response and influence of anionic sites) as well as the possible applications of NPP in biochemistry are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bidens gardneri is a herbaceous species of the cerrados, whose seeds are light sensitive at 25 °C, but they become indifferent to light when stored in soil. In this work the effects of moisture content, temperature and light (during storage) upon light sensitivity during germination were studied. Ripe achenes were collected in the cerrados of Itirapina and Moji Guaçu, State of São Paulo, Brazil. The storage conditions of the achenes varied in each experiment. Achenes were stored in darkness or light, in closed bottles, at 4 °C, 20/30 °C or 25 °C. Achenes were imbibed for 24 h at 4 °C, 25 °C or 20/30 °C (in darkness) and then stored for 1, 10, 20, 30 and 40 days (40 days only for 4 °C and 25 °C). Germination tests were conducted at 25 °C and 20/30 °C. The achenes not previously imbibed showed sensitivity to light during germination. High moisture content did not affect light sensitivity of the achenes during germination but high moisture content together with storage temperatures of 25 °C and 20/30 °C had a deleterious effect upon the longevity of the achenes. Alternate temperatures during germination did not change the light sensitivity of newly collected achenes from Itirapina but changed the light sensitivity of the achenes stored imbibed at 4 °C in darkness. Alternate temperatures during storage of achenes with low moisture content did not change their photoblastism when germination was carried out at 25 °C. Alternate temperatures during storage of achenes with high moisture content followed by alternate temperatures during germination changed the light sensitivity of the achenes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various categories of food packaging indicators namely; VTT, Ageless Eye, Mocon, Åbo Akademi and Impak were selected and incorporated into food trays manufactured at LUT packaging laboratory. Each of these food packaging indicators was used to investigate (visually and qualitatively) the transmission of oxygen through the seal, and tray material, as well as to detect microbial activity within the content of the package. Applications of different methods of gas flushing, content variation and introduction of two distinct levels of oxygen scavengers were employed as treatments to evaluate the packaging performance of the food packaging indicators. Ease of handling of each food packaging indicator was also taken into considerations. Findings showed that for packages, which contained chicken product, the amount of oxygen in the package, measured immediately after the sealing operation on the first day gradually decreased to zero percent by the third day of the storage period. The oxygen level remained at this point throughout the duration of storage for the chicken packages. Besides, level of oxygen in the packages without product continued to increase with the storage time, at moderate rate of 0.1% for 100%N2 and 0.3% for 30%CO2/70%N2 empty packages. More carbon dioxide gas was recorded for packages flushed with 30%CO2/70%N2. Results also revealed that visual analysis of one of the color indicators for example Ageless Eye, conformed to the data derived from the luminescence food-packaging indicator. This shows that packaging operation of the packaging line was considerably stable, and efficient with negligible exception. However, it was found that most of the food packaging indicators investigated in this research study exhibited considerable packaging challenges, such as, reaction with the content of the package (Impak); over sensitivity (Åbo Akademi and Impak); ease of handling problem (Åbo Akademi); and ease of activation problem (VTT indicators). In this study, the strengths and limitations of different indicators were analyzed. This study demonstrates the applicability of various indicators in MAP using chicken package application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ventilator-associated pneumonia (VAP) remains one of the major causes of infection in the intensive care unit (ICU) and is associated with the length of hospital stay, duration of mechanical ventilation, and use of broad-spectrum antibiotics. We compared the frequency of VAP 10 months prior to (pre-intervention group) and 13 months after (post-intervention group) initiation of the use of a heat and moisture exchanger (HME) filter. This is a study with prospective before-and-after design performed in the ICU in a tertiary university hospital. Three hundred and fourteen patients were admitted to the ICU under mechanical ventilation, 168 of whom were included in group HH (heated humidifier) and 146 in group HME. The frequency of VAP per 1000 ventilator-days was similar for both the HH and HME groups (18.7 vs 17.4, respectively; P = 0.97). Duration of mechanical ventilation (11 vs 12 days, respectively; P = 0.48) and length of ICU stay (11 vs 12 days, respectively; P = 0.39) did not differ between the HH and HME groups. The chance of developing VAP was higher in patients with a longer ICU stay and longer duration of mechanical ventilation. This finding was similar when adjusted for the use of HME. The use of HME in intensive care did not reduce the incidence of VAP, the duration of mechanical ventilation, or the length of stay in the ICU in the study population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This literature review aims to clarify what is known about map matching by using inertial sensors and what are the requirements for map matching, inertial sensors, placement and possible complementary position technology. The target is to develop a wearable location system that can position itself within a complex construction environment automatically with the aid of an accurate building model. The wearable location system should work on a tablet computer which is running an augmented reality (AR) solution and is capable of track and visualize 3D-CAD models in real environment. The wearable location system is needed to support the system in initialization of the accurate camera pose calculation and automatically finding the right location in the 3D-CAD model. One type of sensor which does seem applicable to people tracking is inertial measurement unit (IMU). The IMU sensors in aerospace applications, based on laser based gyroscopes, are big but provide a very accurate position estimation with a limited drift. Small and light units such as those based on Micro-Electro-Mechanical (MEMS) sensors are becoming very popular, but they have a significant bias and therefore suffer from large drifts and require method for calibration like map matching. The system requires very little fixed infrastructure, the monetary cost is proportional to the number of users, rather than to the coverage area as is the case for traditional absolute indoor location systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The moisture adsorption characteristics of dried ginger slices was studied to determine the effect of storage conditions on moisture adsorption for the purpose of shelf life prediction, selection of appropriate packaging materials, evaluate the goodness-of-fit of sorption models, and determine the thermodynamics of moisture adsorption for application in drying. There was a highly significant effect (p < 0.05) of water activity (a w), temperature, and pre-treatment on the equilibrium moisture content (EMC) of the dried ginger slices. At constant a w, the EMC decreased as temperature increased. The EMC of all samples increased as the a w increased at constant temperature. The sorbed moisture of the unpeeled ginger slices was higher than the peeled while those of unblanched samples were higher than the blanched. Henderson equation allows more accurate predictions about the isotherms with the lowest %RMS, and therefore, it describes best the adsorption data followed by GAB, Oswin, and Halsey models in that order. The monolayer moisture generally decreased with temperature for all samples. The isosteric heat decreased with moisture content approaching the asymptotic value or the latent heat of vaporization of pure water (∆Hst = 0) while the entropy of sorption was observed to increase with moisture content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bee pollen moisture value is one of the quality parameters for this product. Some countries such as Argentina, Brazil, Bulgaria, Poland and Switzerland have bee pollen regulations on quality parameters, but these are not clear regarding which method should be used for moisture determination. The aim of this paper was to compare six methods of moisture determination in dried bee pollen samples. The methods were: conventional oven at 100 °C, vacuum oven at 70 °C, desiccator with sulfuric acid, drying out process with infrared light at 85 °C, lyophilization and Karl Fisher's method. Based on the results, the best methods for moisture determination of bee pollen were the drying process with infrared and the lyophilization, since these have shown lower moisture values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moisture desorption isotherms of fresh and heat blanched pumpkins (Cucurbita moschata) were determined at three temperatures (30, 50 and 70 °C), using the standard, static-gravimetric method. The GAB, Oswin, BET, Halsey, and Henderson models were tested and, with the exception of the Henderson model, showed satisfactory fits to the experimental data. The GAB model was used to analyze the fitting ability to describe the isotherm type. The shape of the desorption isotherms of fresh and blanched pumpkin at 30 and 50 °C was intermediate to types II and III, and at 70 °C it was of type II for the blanched pumpkin and close to type II for the fresh sample. The influence of blanching on the decrease in equilibrium moisture was very small compared to the fresh samples and it was related to the loss of soluble solids during the pre-treatment. The isosteric heat of sorption measures indicated that a larger amount of heat was required to remove the water from the fresh samples than from the blanched ones.