948 resultados para liquid-solid extraction


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the present work, a simple and rapid ligand-less, in situ, surfactant-based solid phase extraction for the preconcentration of copper in water samples was developed. In this method, a cationic surfactant (n-dodecyltrimethylammonium bromide) was dissolved in an aqueous sample followed by the addition of an appropriate ion-pairing agent (ClO4-). Due to the interaction between the surfactant and ion-pairing agent, solid particles were formed and subsequently used for the adsorption of Cu(OH)2 and CuI. After centrifugation, the sediment was dissolved in 1.0 mL of 1 mol L-1 HNO3 in ethanol and aspirated directly into the flame atomic absorption spectrometer. In order to obtain the optimum conditions, several parameters affecting the performance of the LL-ISS-SPE, including the volumes of DTAB, KClO4, and KI, pH, and potentially interfering ions, were optimized. It was found that KI and phosphate buffer solution (pH = 9) could extract more than 95% of copper ions. The amount of copper ions in the water samples varied from 3.2 to 4.8 ng mL-1, with relative standard deviations of 98.5%-103%. The determination of copper in water samples was linear over a concentration range of 0.5-200.0 ng mL-1. The limit of detection (3Sb/m) was 0.1 ng mL-1 with an enrichment factor of 38.7. The accuracy of the developed method was verified by the determination of copper in two certified reference materials, producing satisfactory results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A procedure for separation and preconcentration of trace amounts of Zn(II) from aqueous media is proposed. The procedure is based on the adsorption of Zn2+ on octadecyl bonded silica membrane disk modified with N,N'-disalicylidene-1,2-phenylendiamine at pH 7. The retained zinc ions were then stripped from the disk with a minimal amount of 1.5 mol L-1 hydrochloric acid solution as eluent, and determined by flame atomic absorption spectrometry. Maximum capacity of the membrane disk modified with 5 mg of the ligand was found to be 226 µg Zn2+. The relative standard deviation of zinc for ten replicate extraction of 10 µg zinc from 1000 mL samples was 1.2%. The limit of detection of the proposed method was 14 ng of Zn2+ per 1000 mL. The method was successfully applied to the determination of zinc in natural water samples and accuracy was examined by recovery experiments and independent analysis by graphite furnace atomic absorption spectrometry (GFAAS).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents an experimental research about the behavior of two-phase flows in inclined pipes. The inclination angle varied from 5° to 45° and the slurry solid concentration varied up to 15%. It was concluded that the head losses of the downward sloping pipe flow are always lower than the head losses of the horizontal flow and these are always lower than the head losses of the upward sloping pipe flow, regardless the concentration and inclination angle. It was possible to develop empirical equations to calculate the head losses of the horizontal flow and the upward and downward sloping pipe flows.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ion mobility spectrometry (IMS) is a straightforward, low cost method for fast and sensitive determination of organic and inorganic analytes. Originally this portable technique was applied to the determination of gas phase compounds in security and military use. Nowadays, IMS has received increasing attention in environmental and biological analysis, and in food quality determination. This thesis consists of literature review of suitable sample preparation and introduction methods for liquid matrices applicable to IMS from its early development stages to date. Thermal desorption, solid phase microextraction (SPME) and membrane extraction were examined in experimental investigations of hazardous aquatic pollutants and potential pollutants. Also the effect of different natural waters on the extraction efficiency was studied, and the utilised IMS data processing methods are discussed. Parameters such as extraction and desorption temperatures, extraction time, SPME fibre depth, SPME fibre type and salt addition were examined for the studied sample preparation and introduction methods. The observed critical parameters were extracting material and temperature. The extraction methods showed time and cost effectiveness because sampling could be performed in single step procedures and from different natural water matrices within a few minutes. Based on these experimental and theoretical studies, the most suitable method to test in the automated monitoring system is membrane extraction. In future an IMS based early warning system for monitoring water pollutants could ensure the safe supply of drinking water. IMS can also be utilised for monitoring natural waters in cases of environmental leakage or chemical accidents. When combined with sophisticated sample introduction methods, IMS possesses the potential for both on-line and on-site identification of analytes in different water matrices.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of fungi in weeds control programs depends upon the conidia production in large scale. Therefore, this study aimed to evaluate liquid and solid culture media and the cultivation by biphasic system for the conidia production of Bipolaris euphorbiae Muchovej & Carvalho a specific pathogen of Euphorbia heterophylla. The liquid media were obtained from agro-industrial waste or by-products, and the solid media were prepared with mixtures of grains and grain derivatives. The liquid medium made with sugar cane molasses stood out from the others because it provided great sporulation (23 x 10(4) conidia mL-1 of medium), conidial viability (99.7%), and formation of mycelial fungal biomass (1.26 g 100 mL-1 of medium). On solid media conidial production was markedly higher than in liquid media, especially the medium composed by a blend of sorghum grain (40%) and soybean hulls (60%) where the fungus produced 2.3 x 10(7) conidia g-1 of medium. The cultivation of B. euphorbiae in biphasic system not promoted a significant increase in the production of conidia. The solid media were more effective for the mass production of fungus and mixtures of grains and derivatives were effective for increasing conidia production.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of the present study was the assessment of volatile organic compounds produced by Sporidiobolus salmonicolor (CBS 2636) using methyl and ethyl ricinoleate, ricinoleic acid and castor oil as precursors. The analysis of the volatile organic compounds was carried out using Head Space Solid Phase Micro-Extraction (HS - SPME). Factorial experimental design was used for investigating extraction conditions, verifying stirring rate (0-400 rpm), temperature (25-60 ºC), extraction time (10-30 minutes), and sample volume (2-3 mL). The identification of volatile organic compounds was carried out by Gas Chromatography with Mass Spectrum Detector (GC/MSD). The conditions that resulted in maximum extraction were: 60 ºC, 10 minutes extraction, no stirring, sample volume of 2.0 mL, and addition of saturated KCl (1:10 v/v). In the bio-production of volatile organic compounds the effect of stirring rate (120-200 rpm), temperature (23-33 ºC), pH (4.0-8.0), precursor concentration (0.02-0.1%), mannitol (0-6%), and asparagine concentration (0-0.2%) was investigated. The bio-production at 28 ºC, 160 rpm, pH 6,0 and with the addition of 0.02% ricinoleic acid to the medium yielded the highest production of VOCs, identified as 1,4-butanediol, 1,2,2-trimethylciclopropilamine, beta-ionone; 2,3-butanodione, pentanal, tetradecane, 2-isononenal, 4-octen-3-one, propanoic acid, and octadecane.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, a protocol for the formulation of an enzyme concentrated product to be applied in fruit juice treatment is described. Downstream processing conditions for the recovery and concentration of pectinases produced by the new strain Aspergillus niger LB-02-SF in solid state cultivation were assessed. The solid-liquid ratio in the extraction step of pectinases recovery from the cultivated media was evaluated and the highest activity was obtained with a solid-liquid ratio of 1:10. The crude extract was concentrated by ultrafiltration and the total pectinase (TP) activity was 73.6-fold concentrated in relation to the crude extract, and a final TP titer of 663 U mL–1 was obtained with 73.7% of recovery yield. KCl and different glycerol concentrations were added to the concentrated extract and the stability of pectinases during the storage at 5°C for 59 weeks was tested. The formulation with 50% w/w glycerol was applied to the treatment of apple and grape juices and the results of these tests were statistically comparable to those obtained with two high-quality commercial preparations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract The use of agroindustrial residues is an economical solution to industrial biotechnology. Coffee husk and pulp are abounding residues from coffee industry which can be used as substrates in solid state fermentation process, thus allowing a liberation and increase in the phenolic compound content with high added value. By employing statistical design, initial moisture content, pH value in the medium, and the incubation temperature were evaluated, in order to increase the polyphenol content in a process of solid state fermentation by Penicillium purpurogenum. The main phenolic compounds identified through HPLC in fermented coffee residue were chlorogenic acid, caffeic acid, and rutin. Data obtained through HPLC with the radical absorbance capacity assay suggest the fermented coffee husk and pulp extracts potential as a source of phenolic acids and flavonoids. Results showed good perspectives when using P. purpurogenum strain to enhance the liberation of phenolic compounds in coffee residues.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An efficient way of synthesizing the deuterium labelled analogues of three methoxypyrazine compounds: 2-d3-methoxy-3-isopropylpyrazine, 2-d3-methoxy-3- isobutylpyrazine, and 2-d3-methoxy-3-secbutylpyrazine, has been developed. To confirm that the deuterium labels had been incorporated into the expected positions in the molecules synthesized, the relevant characterization by NMR, HRMS and GC/MS analysis was conducted. Another part of this work involved quantitative determination of methoxypyrazines in water and wines. Solid-phase extraction (SPE) proved to be a suitable means for the sample separation and concentration prior to GC/MS analysis.Such factors as the presence of ethanol, salt, and acid have been investigated which can influence the recovery by SPE for the pyrazines from the water matrix. Significantly, in this work comparatively simple fractional distillation was attempted to replace the conventional steam distillation for pre-concentrating a sample with a relatively large volume prior to SPE. Finally, a real wine sample spiked with the relevant isotope-labelled methoxypyrazines was quantitatively analyzed, revealing that the wine with 10 beetles per litre contained 138 ppt of 2-methoxy-3-isopropylpyrazine. Interestingly, we have also found that 2-methoxy-3-secbutylpyrazine exhibits an extremely low detection limit in GC/MS analysis compared with the detection limit of the other two methoxypyrazines: 2- methoxy-3-isopropylpyrazine and 2-methoxy-3-isobutylpyrazine.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Les dernières décennies ont été marquées par une augmentation du nombre des cas de cancers, ce qui a subséquemment conduit à une augmentation dans la consommation des agents de chimiothérapie. La toxicité et le caractère cancérogène de ces molécules justifient l’intérêt crucial porté à leur égard. Quelques études ont fait l’objet de détection et de quantification des agents de chimiothérapie dans des matrices environnementales. Dans ce projet, une méthode utilisant la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS) précédée d’une extraction sur phase solide (SPE) automatisée ou en ligne a été développée pour la détection et la quantification d’un groupe de six agents de chimiothérapie. Parmi ceux-ci figurent les plus utilisés au Québec (gemcitabine, méthotrexate, cyclophosphamide, ifosfamide, irinotécan, épirubicine) et présentant des propriétés physico-chimiques et des structures chimiques différentes. La méthode développée a été validée dans une matrice réelle représentant l’affluent d’une station d’épuration dans la région de Montréal. Deux des six composés cytotoxiques étudiés en l’occurrence (cyclophosphamide et méthotrexate) ont été détectés dans huit échantillons sur les neuf qui ont été recensés, essentiellement au niveau de l’affluent et l’effluent de quelques stations d’épuration de la région de Montréal. Les résultats des analyses effectuées sur les échantillons réels ont montré qu’il n’y avait pas de différence significative dans la concentration entre l’affluent et l’effluent, et donc que les systèmes d’épuration semblent inefficaces pour la dégradation de ces molécules.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

La phosphorylation des protéines constitue l’une des plus importantes modifications post-traductionnelles (PTMs) et intervient dans de multiples processus physiologiques tels, la croissance, la différenciation cellulaire, l’apoptose, etc. En dépit de son importance, l’analyse des phosphoprotéines demeure une tâche difficile en raison de leur nature dynamique (car la phosphorylation des protéines est un processus réversible) et de leur faible abondance relative. En effet, la détermination des sites de phosphorylation est souvent difficile car les phosphopeptides sont souvent difficiles à détecter par des méthodes d’analyse chromatographique classique et par spectrométrie de masse (MS). De récentes études ont démontré que les nombreuses méthodes d’enrichissement de phosphopeptides existantes ne sont pas complètes, et que le nombre total de phosphopeptides détectés ne chevauchent pas complètement ces méthodes. C’est pour cela qu’il existe une nécessité de combler les lacunes des méthodes d’enrichissement existantes afin d’avoir des analyses phosphoprotéomiques plus complètes. Dans cette étude, nous avons utilisé les liquides ioniques (LI), plus particulièrement les sels d’imidazolium, comme une technique d’enrichissement alternative, dans le but de favoriser une extraction sélective de phosphopeptides présents en solution. Les sels d’imidazolium ont donc été utilisés en raison de leurs propriétés physico-chimiques "facilement" ajustables selon la nature des substituants sur le noyau imidazolium et la nature de l’anion. Les sels de monoimidazolium et de bis-imidazolium possédant respectivement des chaînes linéaires à 4, 12 et 16 atomes de carbone et ayant différents anions ont été synthétisés et utilisés pour effectuer des extractions liquide-liquide et solide-liquide des phosphopeptides en solution. Dans un premier temps, des extractions liquide-liquide ont été réalisées en utilisant un liquide ionique (LI) ayant une chaine linéaire de 4 atomes de carbone. Ces extractions réalisées avec le bis(trifluoromethanesulfonyl) amide de 3-butyl-1-methylimidazolium (BMIM-NTf2) et l’hexafluorophosphate de 3-butyl-1-methylimidazolium (BMIM-PF6) n’ont pas montré une extraction notable du PPS comparativement au PN. Dans un deuxième temps, des extractions solide-liquide ont été réalisées en fonctionnalisant des particules solides avec des sels d’imidazolium possédant des chaines linéaires de 12 ou 16 atomes de carbone. Ces extractions ont été faites en utilisant un phosphopentapeptide Ac-Ile-pTyr-Gly-Glu-Phe-NH2 (PPS) en présence de 2 analogues acides non-phosphorylés. Il a été démontré que les sels d’imidazolium à chaine C12 étaient meilleurs pour extraire le PPS que les deux autres peptides PN (Ac-Ile-Tyr-Gly-Glu-Phe-NH2) et PE (Ac-Glu-Tyr-Gly-Glu-Phe-NH2) L’électrophorèse capillaire (CE) et la chromatographie liquide à haute performance couplée à la spectrométrie de masse (LC-MS) ont été utilisées pour quantifier le mélange des trois peptides avant et après extraction ; dans le but de mesurer la sélectivité et l’efficacité d’extraction de ces peptides par rapport à la composition chimique du liquide ionique utilisé.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Solid phase extraction (SPE) is a powerful technique for preconcentration/removal or separation of trace and ultra trace amounts of toxic and nutrient elements. SPE effectively simplifies the labour intensive sample preparation, increase its reliability and eliminate the clean up step by using more selective extraction procedures. The synthesis of sorbents with a simplified procedure and diminution of the risks of errors shows the interest in the areas of environmental monitoring, geochemical exploration, food, agricultural, pharmaceutical, biochemical industry and high purity metal designing, etc. There is no universal SPE method because the sample pretreatment depends strongly on the analytical demand. But there is always an increasing demand for more sensitive, selective, rapid and reliable analytical procedures. Among the various materials, chelate modified naphthalene, activated carbon and chelate functionalized highly cross linked polymers are most important. In the biological and environmental field, large numbers of samples are to be analysed within a short span of time. Hence, online flow injection methods are preferred as they allow extraction, separation, identification and quantification of many numbers of analytes. The flow injection online preconcentration flame AAS procedure developed allows the determination of as low as 0.1 µg/l of nickel in soil and cobalt in human hair samples. The developed procedure is precise and rapid and allows the analysis of 30 samples per hour with a loading time of 60 s. The online FI manifold used in the present study permits high sampling, loading rates and thus resulting in higher preconcentration/enrichment factors of -725 and 600 for cobalt and nickel respectively with a 1 min preconcentration time compared to conventional FAAS signal. These enrichment factors are far superior to hitherto developed on line preconcentration procedures for inorganics. The instrumentation adopted in the present study allows much simpler equipment and low maintenance costs compared to costlier ICP-AES or ICP-MS instruments.