953 resultados para interpersonal reproducibility
Resumo:
BACKGROUND: The Bispectral Index (BIS) reportedly reflects anesthetic depth. It is recommended that anesthetic agents should be titrated to maintain the BIS between 40 and 60 arbitrary BIS units during anesthesia. For anesthesia providers to follow this recommendation, the monitor should be predictably affected by different anesthetic agents and have good interpatient and intrapatient reproducibility. The authors hypothesized that when two BISxp devices (Aspect Medical Systems, Newton, MA) are placed concurrently on the same patient, their readings are concordant throughout the anesthetic period. METHODS: Simultaneous BIS recordings from two BISxp monitors were obtained during anesthesia at 5-s intervals from 12 participants. RESULTS: In total 22,860 concurrent paired BIS readings were obtained. For 10.7% of the time, there were sustained periods of 30 s or greater where the readings suggested a different depth of anesthesia. For 6% of the time, there were sustained periods of 30 s or greater where the readings differed by 10 or more arbitrary BIS units. The regression coefficient (R) for the two devices was 0.65 (range, 0.35-0.92). There was zero bias between the devices, and the 95% limits of agreement ranged between -18 and +17. CONCLUSION: A conflicting anesthetic management was suggested by the simultaneous BIS readings 10.7% of the time. These results suggest that BISxp does not always provide a reproducible single number. Anesthesia providers should not rely exclusively on the BIS reading when assessing depth of anesthesia.
Resumo:
1H-magnetic resonance spectroscopy ((1)H-MRS) of deoxymyoglobin (DMb) provides a means to noninvasively monitor the oxygenation state of human skeletal muscle in work and disease. As shown in this work, it also offers the opportunity to measure the absolute tissue content of DMb, the basic oxygen consumption of resting muscle, and the reperfusion characteristics after release of a pressure cuff. The methodology to determine these tissue properties simultaneously at two positions along the calf is presented. The obtained values are in agreement with invasive determinations. The reproducibility of the (1)H-MRS measurements is established for healthy controls and patients with peripheral arterial disease (PAD). A location dependence in axial direction, as well as differences between controls and patients are demonstrated for all parameters. The reoxygenation time in particular is expected to provide a means to quantitatively monitor therapies aimed at improving muscular perfusion in these patients.
Resumo:
OBJECTIVE: The objective of this study was to evaluate the feasibility and reproducibility of high-resolution magnetic resonance imaging (MRI) and quantitative T2 mapping of the talocrural cartilage within a clinically applicable scan time using a new dedicated ankle coil and high-field MRI. MATERIALS AND METHODS: Ten healthy volunteers (mean age 32.4 years) underwent MRI of the ankle. As morphological sequences, proton density fat-suppressed turbo spin echo (PD-FS-TSE), as a reference, was compared with 3D true fast imaging with steady-state precession (TrueFISP). Furthermore, biochemical quantitative T2 imaging was prepared using a multi-echo spin-echo T2 approach. Data analysis was performed three times each by three different observers on sagittal slices, planned on the isotropic 3D-TrueFISP; as a morphological parameter, cartilage thickness was assessed and for T2 relaxation times, region-of-interest (ROI) evaluation was done. Reproducibility was determined as a coefficient of variation (CV) for each volunteer; averaged as root mean square (RMSA) given as a percentage; statistical evaluation was done using analysis of variance. RESULTS: Cartilage thickness of the talocrural joint showed significantly higher values for the 3D-TrueFISP (ranging from 1.07 to 1.14 mm) compared with the PD-FS-TSE (ranging from 0.74 to 0.99 mm); however, both morphological sequences showed comparable good results with RMSA of 7.1 to 8.5%. Regarding quantitative T2 mapping, measurements showed T2 relaxation times of about 54 ms with an excellent reproducibility (RMSA) ranging from 3.2 to 4.7%. CONCLUSION: In our study the assessment of cartilage thickness and T2 relaxation times could be performed with high reproducibility in a clinically realizable scan time, demonstrating new possibilities for further investigations into patient groups.
Resumo:
The aims of this study were to examine the clinical feasibility and reproducibility of kinematic MR imaging with respect to changes in T (2) in the femoral condyle articular cartilage. We used a flexible knee coil, which allows acquisition of data in different positions from 40 degrees flexion to full extension during MR examinations. The reproducibility of T (2) measurements was evaluated for inter-rater and inter-individual variability and determined as a coefficient of variation (CV) for each volunteer and rater. Three different volunteers were measured twice and regions of interest (ROIs) were selected by three raters at different time points. To prove the clinical feasibility of this method, 20 subjects (10 patients and 10 age- and sex-matched volunteers) were enrolled in the study. Inter-rater variability ranged from 2 to 9 and from 2 to 10% in the deep and superficial zones, respectively. Mean inter-individual variability was 7% for both zones. Different T (2) values were observed in the superficial cartilage zone of patients compared with volunteers. Since repair tissue showed a different behavior in the contact zone compared with healthy cartilage, a possible marker for improved evaluation of repair tissue quality after matrix-associated autologous chondrocyte transplantation (MACT) may be available and may allow biomechanical assessment of cartilage transplants.
Resumo:
We developed a gel- and label-free proteomics platform for comparative studies of human serum. The method involves the depletion of the six most abundant proteins, protein fractionation by Off-Gel IEF and RP-HPLC, followed by tryptic digestion, LC-MS/MS, protein identification, and relative quantification using probabilistic peptide match score summation (PMSS). We evaluated performance and reproducibility of the complete platform and the individual dimensions, by using chromatograms of the RP-HPLC runs, PMSS based abundance scores and abundance distributions as objective endpoints. We were interested if a relationship exists between the quantity ratio and the PMSS score ratio. The complete analysis was performed four times with two sets of serum samples containing different concentrations of spiked bovine beta-lactoglobulin (0.1 and 0.3%, w/w). The two concentrations resulted in significantly differing PMSS scores when compared to the variability in PMSS scores of all other protein identifications. We identified 196 proteins, of which 116 were identified four times in corresponding fractions whereof 73 qualified for relative quantification. Finally, we characterized the PMSS based protein abundance distributions with respect to the two dimensions of fractionation and discussed some interesting patterns representing discrete isoforms. We conclude that combination of Off-Gel electrophoresis (OGE) and HPLC is a reproducible protein fractionation technique, that PMSS is applicable for relative quantification, that the number of quantifiable proteins is always smaller than the number of identified proteins and that reproducibility of protein identifications should supplement probabilistic acceptance criteria.
Resumo:
PURPOSE: To investigate the reproducibility of dGEMRIC in the assessment of cartilage health of the adult asymptomatic hip joint. MATERIALS AND METHODS: Fifteen asymptomatic volunteers (mean age, 26.3 years +/- 3.0) were preliminarily studied. Any volunteer that was incidentally diagnosed with damaged cartilage on MRI (n = 5) was excluded. Ten patients that had no evidence of prior cartilage damage (mean age, 26.2 years +/- 3.4) were evaluated further in this study. The reproducibility of dGEMRIC was assessed with two T1(Gd) exams performed 4 weeks apart in these volunteers. The protocol involved an initial standard MRI to confirm healthy cartilage, which was then followed by dGEMRIC. The second scan included only the repeat dGEMRIC. Region of interest (ROI) analyses for T1(Gd)-measurement was performed in seven radial reformats. Statistical analysis included the student's t-test and intra-class correlation (ICC) measurement to assess reproducibility. RESULTS: Overall 70 ROIs were studied. Mean cartilage T1(Gd) values at various loci ranged from 560.9 ms to 684.4 ms at the first set of readings and 551.5 ms to 662.2 ms in the second one. The mean difference per region of interest between the two T1(Gd)-measurements ranged from 21.4 ms (3.7%) to 45.0 ms (6.8%), which was not found to be statistically significant (P = 0.153). There was a high reproducibility detected (ICC range, 0.667-0.915). Intra- and Inter-observer analyses proved a high agreement for T1(Gd) assessment (0.973 and 0.932). CONCLUSION: We found dGEMRIC to be a reliable tool in the assessment of cartilage health status in adult hip joints.
Resumo:
OBJECTIVES: The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries. METHODS: One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility. RESULTS: For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively. CONCLUSIONS: ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.
Resumo:
The reproducibility of metabolite content determined by MR spectroscopy (MRS) is usually at best a few percent for the prominent singlets. When studying low-concentration metabolites, like phenylalanine (Phe), where tissue content can be <100 micromol/kg, better reproducibility is paramount-particularly in view of using MRS results for potential individual treatment advice. An optimized, targeted spectroscopy method was established at 1.5T and reproducibility was established in 21 patients with phenylketonuria (PKU) where three spectra were recorded in each of three independent sessions, two of which were in immediate succession to minimize physiologic variation. Intersession variation was found to be only 7 micromol/kg Phe for back-to-back repetition of sessions, in close agreement with the variation of 16 micromol/kg observed for single spectra within a session. Analysis of variance proved the individuality of the blood/brain Phe ratio-though this ratio seems to be influenced by physiologic factors that are not stable in time. The excellent reproducibility was achieved through optimization of various factors, including signal-to-noise ratio, repositioning, and prescan calibrations, but also by enforcing as much prior information as possible (e.g., lineshape and phase from reference scans, constant prior-knowledge-locked baseline). While the application of maximum general prior knowledge is a general method to reduce fluctuations, one should remember that it may introduce systematic errors.
Resumo:
PURPOSE: To test the reproducibility of retinal thickness measurements in healthy volunteers of a new Frequency-domain optical coherence tomography (OCT) device (Spectralis OCT; Heidelberg Engineering, Heidelberg, Germany). DESIGN: Prospective, observational study. METHODS: Forty-one eyes of 41 healthy subjects were included into the study. Intraobserver reproducibility was tested with 20 x 15 degree raster scans consisting of 37 high-resolution line scans that were repeated three times by one examiner (M.N.M.). Mean retinal thickness was calculated for nine areas corresponding to the Early Treatment Diabetic Retinopathy Study (ETDRS) areas. Coefficients of variation (COV) were calculated. RESULTS: Retinal thickness measurements were highly reproducible for all ETDRS areas. Mean total retinal thickness was 342 +/- 15 microm. Mean foveal thickness was 286 +/- 17 microm. COVs ranged from 0.38% to 0.86%. Lowest COV was found for the temporal outer ETDRS area (area 7; COV, 0.38%). Highest COV was found for the temporal inner ETDRS area (area 3; COV, 0.86%). Mean difference between measurement 1 and 2, measurement 1 and 3, and measurement 2 and 3 for all ETDRS areas was 1.01 microm, 0.98 microm, and 0.99 microm, respectively. CONCLUSION: Spectralis OCT retinal thickness measurements in healthy volunteers showed excellent intraobserver reproducibility with virtually identical results between retinal thickness measurements performed by one operator.
Resumo:
Forgiveness is often assumed to be adaptive for psychological adjustment following interpersonal transgressions. Three hundred and forty seven individuals who had experienced a recent interpersonal transgression were surveyed on four occasions over the course of six weeks. Forgiveness was assessed with scales measuring interpersonal avoidance and revenge motivation and psychological adjustment was assessed with scales measuring depression and rumination. Latent growth curve analyses showed that intraindividual changes in forgiveness were positively correlated with changes in adjustment. Latent difference score analyses indicated that adjustment predicted subsequent change in forgiveness, but that forgiveness did not predict subsequent change in adjustment. The results suggest that adjustment facilitates forgiveness, but not that forgiveness facilitates adjustment.