931 resultados para high voltage


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A study of the gap breakdown voltage characteristic at a low pressure of 7×10-5 Torr with a standard (1/50)-μsec impulse-voltage wave reveals an agreement with the criterion Vb=Cd0.5 suggested by Cranberg. Voltage-time-to-breakdown characteristics has also been determined. From these studies, it is concluded that impulse breakdown in vacuum is initiated by an electron current heating an anode spot and thereby liberating a clump which causes breakdown.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The low frequency dielectric behavior of castor oil (a vegetable oil) has been analyzed quite exhaustively in the context of its application as impregnant in capacitors. For the sake of completeness and in order to understand the relaxation phenomena in this liquid dielectric, this high frequency dielectric study was undertaken. In order to compare its properties with a liquid dielectric used in similar application and whose high frequency behavior has been quite well analyzed, Arochlor 1476 was studied. It is observed that both liquids have distributed relaxation times. The distribution parameters together with the two distinct relaxation times have been calculated by measuring the average relaxation time. It has been found that the distinct relaxation times thus calculated represent the dielectric behavior quite satisfactorily. The average dipole moments, dipole radii and thermal activation energies for dipole relaxation have also been evaluated.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The design of a three‐stage high‐gain amplifier for laboratory use in audiofrequency investigations is described. Four‐electrode tubes are used as screen‐grid amplifiers and an amplification of the order of 200 per stage is obtained. The inaccuracy of McDonald's formula for calculation of stage‐gain has been pointed out. The gain‐frequency characteristics are given for power as well as voltage amplification. It is shown that extreme care is necessary in the design of shielding to obtain highvoltage amplification of the order of 120 decibels as obtained in this three‐stage amplifier.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The firing characteristics of the simple triggered vacuum gap (TVG) using lead zirconate titanate as dielectric material in the triggered gap are described. This TVG has a long life of about 2000 firings without appreciable deterioration of the electrical properties for main discharge currents upto 3 kA and is much superior to these made with Supramica (Mycalex Corporation of America) and silicon carbide as used in our earlier investigations. The effects of the variation of trigger voltage, trigger curcit, trigger pulse duration, trigger pulse energy, main gap voltage, main gap separation and main circuit energy on the firing characteristics have been studied. Trigger resistance progressively decreases with the number of firings of the trigger gap and as well as of the main gap. This decrease in the trigger resistance is more pronounced for main discharge currents exceeding 10 kA. The minimum trigger current required for reliable firing decreases with increase of trigger voltage upto a threshold value of 1.2 kV and there-onwards saturates at 3.0 A. This value is less than that obtained with Supramica as dielectric material. One hundred percent firing probability of the TVG at main gap voltages as low as 50 V is possible and this low voltage breakdown of the main gap appears to be similar to the breakdown at low pressures between moving plasma by other workers. and the cold electrodes immersed in it, as reported.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A mathematical model has been proposed to determine the voltage/current characteristic of the surge diverter for a wide range of currents of short duration of 8/20 and 4/10ÿs waveshapes. Experimental data agree well with the proposed model.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In the determination of the response time of u.h.v. damped capacitive impulse voltage dividers using the CIGRE IMR-1MS group (1) method and the arrangement suggested by the International Electrotechnical Commission (the I EC square loop),the surge impedance of the connecting lead has been found to influence the accuracy of determination. To avoid this difficulty,a new graphical procedure is proposed. As this method uses only those data points which can be determined with good accuracy, errors in response-time area evaluation do not influence the result.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A new scheme for nine-level voltage space-vector generation for medium-voltage induction motor (IM) drives with open-end stator winding is presented in this paper. The proposed nine-level power converter topology consists of two conventional three-phase two-level voltage source inverters powered by isolated dc sources and six floating-capacitor-connected H-bridges. The H-bridge capacitor voltages are effectively maintained at the required asymmetrical levels by employing a space vector modulation (SVPWM) based control strategy. An interesting feature of this topology is its ability to function in five-or three-level mode, in the entire modulation range, at full-power rating, in the event of any failure in the H-bridges. This feature significantly improves the reliability of the proposed drive system. Each leg of the three-phase two-level inverters used in this topology switches only for a half cycle of the reference voltage waveform. Hence, the effective switching frequency is reduced by half, resulting in switching loss reduction in high-voltage devices. The transient as well as the steady-state performance of the proposed nine-level inverter-fed IM drive system is experimentally verified in the entire modulation range including the overmodulation region.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Inverters with high voltage conversion ratio are used in systems with sources such as batteries, photovoltaic (PV) modules or fuel cells. Transformers are often used in such inverters to provide the required voltage conversion ratio and isolation. In this paper, a compact high-frequency (HF) transformer interfaced AC link inverter with lossless snubber is discussed. A high performance synchronized modulation scheme is proposed for this inverter. This modulation addresses the issue of over-voltage spikes due to transformer leakage inductance and it is shown that the circuit can operate safely even when the turn-on delay, such as dead-time, is not used in the HF rectifier section. The problem of spurious turn-on in the HF inverter switches is also mitigated by the proposed modulation method. The circuit performance is validated experimentally with a $900W$ prototype inverter.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A high voltage integrated circuit (HVIC) switch designed as a building block for power converters operating up to 13.56 MHz from off-line voltages is presented. A CMOS-compatible, 500 V power device process is used to integrate control circuitry with a high-speed MOS gate driver and high voltage lateral power MOSFET. Fabrication of the HVIC switches has proceeded in two stages. The first batch of devices showed switching times of less than 5 ns for the power switch and good high frequency performance of a level-shifter for driving half bridge converters. In the second phase, a switch that monolithically integrates all the elements required to form a complete high-frequency converter has been designed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents a comprehensive theoretical study of the Trench Insulated Gate Bipolar Transistors (TIGBT). Specific physical and geometrical effects, such as the accumulation layer injection, increased channel density, increased channel charge and transversal electric field modulation are discussed. The potential advantages of the Trench IGBT over its conventional planar variant are highlighted. It is concluded that the Trench IGBT is one of the most promising structures in the area of high voltage MOS-controllable switching devices.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A 320 kV high voltage (HV) platform has been constructed at Institute of Modern Physics (IMP) to satisfy the increasing requirements of experimental studies in some heavy ion associated directions. A high charge state all-permanent magnet ECRIS-LAPECR2 has been designed and fabricated to provide intense multiple charge state ion beams (such as 1000 e mu A O6+, 16.7 e mu A Ar14+, 24 e mu A Xe27+, etc.) for the HV platform. LAPECR2 has a dimension of 0 650 mm x 560 mm. The powerful 3D magnetic confinement to the ECR plasma and the optimum designed magnetic field for the operation at 14.5 GHz makes it possible to obtain very good performances from this source. After a brief introduction of the ECRIS and accelerator development at IMP, the conceptual design of LAPECR2 source is presented. The first test results of this all-permanent magnet ECRIS are given in this paper.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents transient stability analysis for a power system with high wind penetration. The transient stability has been evaluated based on two stability criteria: rotor angle stability and voltage stability. A modified IEEE-14 bus system has been used as the main study network and simulations have been conducted at several wind power penetration levels, defined as a fraction of total system generation. A wide range of scenarios have been presented based on the wind farm voltage at the point of connection, i.e. low voltage (LV) distribution level and high voltage (HV) transmission level, and the type of wind generator technology, i.e. fixed speed induction generator (FSIG) and doubly-fed induction generator (DFIG).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The power system of the future will have a hierarchical structure created by layers of system control from via regional high-voltage transmission through to medium and low-voltage distribution. Each level will have generation sources such as large-scale offshore wind, wave, solar thermal, nuclear directly connected to this Supergrid and high levels of embedded generation, connected to the medium-voltage distribution system. It is expected that the fuel portfolio will be dominated by offshore wind in Northern Europe and PV in Southern Europe. The strategies required to manage the coordination of supply-side variability with demand-side variability will include large scale interconnection, demand side management, load aggregation and storage in the concept of the Supergrid combined with the Smart Grid. The design challenge associated with this will not only include control topology, data acquisition, analysis and communications technologies, but also the selection of fuel portfolio at a macro level. This paper quantifies the amount of demand side management, storage and so-called ‘back-up generation’ needed to support an 80% renewable energy portfolio in Europe by 2050.