955 resultados para gold standard


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Indirect drug susceptibility tests of Mycobacterium tuberculosis was done to investigate the accuracy and feasibility of a broth microdilution method (BMM) for determining minimal inhibitory concentrations of conventional drugs against M. tuberculosis. Test drugs included isoniazid (H), rifampicin (R), ethambutol (E), streptomycin (S) and pyrazinamide (Z). Fifty isolates of M. tuberculosis from patients who had never received drug therapy, and H37Rv strain for control, were evaluated in the system. When comparing this method with the gold standard proportional method in Lowenstein-Jensen medium, sensitivity of 100% for all drugs and specifities of 91, 100, 96, 98 and 85% were observed respectively for H, R, E, S and Z. The BMM was read faster (14-20 days) than the proportional method (20-28 days). The microdilution method evaluated allows the testing of multiple drugs in multiple concentrations. It is easy to perform and does not require special equipment or expensive supplies. In contrast to radiometric method it does not use radioactive material.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY AND PRINCIPLES: Estimating glomerular filtration rate (GFR) in hospitalised patients with chronic kidney disease (CKD) is important for drug prescription but it remains a difficult task. The purpose of this study was to investigate the reliability of selected algorithms based on serum creatinine, cystatin C and beta-trace protein to estimate GFR and the potential added advantage of measuring muscle mass by bioimpedance. In a prospective unselected group of patients hospitalised in a general internal medicine ward with CKD, GFR was evaluated using inulin clearance as the gold standard and the algorithms of Cockcroft, MDRD, Larsson (cystatin C), White (beta-trace) and MacDonald (creatinine and muscle mass by bioimpedance). 69 patients were included in the study. Median age (interquartile range) was 80 years (73-83); weight 74.7 kg (67.0-85.6), appendicular lean mass 19.1 kg (14.9-22.3), serum creatinine 126 μmol/l (100-149), cystatin C 1.45 mg/l (1.19-1.90), beta-trace protein 1.17 mg/l (0.99-1.53) and GFR measured by inulin 30.9 ml/min (22.0-43.3). The errors in the estimation of GFR and the area under the ROC curves (95% confidence interval) relative to inulin were respectively: Cockcroft 14.3 ml/min (5.55-23.2) and 0.68 (0.55-0.81), MDRD 16.3 ml/min (6.4-27.5) and 0.76 (0.64-0.87), Larsson 12.8 ml/min (4.50-25.3) and 0.82 (0.72-0.92), White 17.6 ml/min (11.5-31.5) and 0.75 (0.63-0.87), MacDonald 32.2 ml/min (13.9-45.4) and 0.65 (0.52-0.78). Currently used algorithms overestimate GFR in hospitalised patients with CKD. As a consequence eGFR targeted prescriptions of renal-cleared drugs, might expose patients to overdosing. The best results were obtained with the Larsson algorithm. The determination of muscle mass by bioimpedance did not provide significant contributions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’adaptació a l’entrenament aeròbic prolongat provoca a nivell cardíac modificacions estructurals i electrocardiogràfiques que es poden considerar parafisiològiques. Una planificació incorrecta de las càrregues de treball i factors externs estressants poden provocar una desadaptació a l’entrenament i de forma crònica en la Síndrome de Sobreentrenament. Aquesta síndrome es reflex d’un desequilibri del sistema autònom, podent presentar en les seves formes més desenvolupades manifestacions cardiovasculars greus. No es disposen actualment d’un marcador diagnòstic definitiu, sent la anamnesis dirigida el “gold standard”. El tractament consisteix en un descans actiu la durada del qual dependrà de la gravetat clínica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dans cette étude, nous avons testé la performance diagnostique d'une nouvelle technique d'analyse multiplexée qui permet la détection d'anticorps de différentes spécificités dans la même réaction. En l'absence de gold standard, nous avons choisi de comparer la performance diagnostique de l'analyse avec deux méthodes de référance que sont l'IF et EIA, et avec un consensus déterminé selon une règle de majorité entre les trois méthodes.¦393 sérums analysés par IF, conservés par congélation, ont été décongelés pour être analysés par EIA et BBA. Pour chaque sérum, les anticorps recherchés ont été les anti-VCA (Viral Capsid Antigen) IgM, anti-VCA IgG et anti-EBNA (Epstein-Barr Nuclear Associated) IgG. Les échantillons ont été classés en cinq groupes selon les résultats de l'IF : séronégatifs, infections aiguës, infections anciennes et deux types d'indéterminés.¦Pour chaque méthode, le résultat numérique (index ou titre) des analyses est converti en termes de positif, négatif ou douteux. Pour le résultat de chaque type d'anticorps, un consensus est établi selon une règle de majorité entre les trois méthodes, permettant une interprétation du stade de l'infection. Puis l'interprétation de chacune des méthodes a été comparée au consensus. Nous avons également comparé les trois méthodes les unes aux autres concernant la détection des anticorps.¦Globalement, nous observons une bonne corrélation qualitative entre les trois approches pour détecter les anti-VCA IgG et IgM. Pour pour les anti-EBNA IgG, il y a une divergence notable entre l'IF et les deux autres méthodes, l'IF apparaissant moins sensible que les autres méthodes, résultant en un nombre accru d'interprétations indéterminées du stade de l'infection.¦L'origine de cette divergence ne peut être due à une perte d'anticorps liée au stockage de longue durée des échantillons. En effet, EIA et BBA restent plus sensibles que IF, dont l'analyse a été faite sur des sérums frais.¦Cette divergence ne semble pas non plus être due aux différents antigènes utilisés par les trois méthodes. EIA et BBA utilisent le même antigène recombinant EBNA-1, alors que l'IF utilise des "cellules lymphoïdes choisies pour leur production sélective d'antigènes EBNA". Ces cellules sont probablement des cellules infectées par EBV qui devraient exprimer plus d'antigènes de latence que seul EBNA-1. Cette différence devrait donc plutôt en principe résulter en une meilleure sensibilité de l'IF par rapport aux deux autres méthodes.¦Les anti-EBNA IgG peuvent disparaître chez les patients immunocompromis chez qui se produit une réactivation d'EBV. Nous avons donc recherché le status immunitaire des patients du groupe dont les sérums étaient négatifs pour anti-EBNA IgG en IF et positifs par les autres méthodes: seulement 28 des 70 patients étaient immunocompromis.¦Par conséquent, il est probable que dans la majorité de ces résultats discordants, les anticorps anti-EBNA IgG détectés par BBA et EIA sont de vrais positifs non décelés par l'IF.¦En conclusion, BBA est meilleur que la méthode de référance qu'est l'IF, et est égal à EIA en ce qui concerne la performance diagnostique. En outre, ces deux nouvelles méthodes offrent une économie de temps en raison de manipulations moindres, et ne requièrent aucune formation en microscopie à fluorescence. Elles sont également plus économes en échantillons que IF. BBA a l'avantage de n'avoir besoin que de deux analyses pour donner un diagnostique, alors que IF et EIA ont en besoin d'une par anticorps. Enfin, BBA dispose de contrôles internes permettant de reconnaître les liaisons non antigène-spécifiques des anticorps. Par contre, BBA nécessite l'achat d'un lecteur par cytométrie de flux assez coûteux.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Second Harmonic Generation (SHG) microscopy recently appeared as an efficient optical imaging technique to probe unstained collagen-rich tissues like cornea. Moreover, corneal remodeling occurs in many diseases and precise characterization requires overcoming the limitations of conventional techniques. In this work, we focus on diabetes, which affects hundreds of million people worldwide and most often leads to diabetic retinopathy, with no early diagnostic tool. This study then aims to establish the potential of SHG microscopy for in situ detection and characterization of hyperglycemia-induced abnormalities in the Descemet's membrane, in the posterior cornea. METHODOLOGY/PRINCIPAL FINDINGS: We studied corneas from age-matched control and Goto-Kakizaki rats, a spontaneous model of type 2 diabetes, and corneas from human donors with type 2 diabetes and without any diabetes. SHG imaging was compared to confocal microscopy, to histology characterization using conventional staining and transmitted light microscopy and to transmission electron microscopy. SHG imaging revealed collagen deposits in the Descemet's membrane of unstained corneas in a unique way compared to these gold standard techniques in ophthalmology. It provided background-free images of the three-dimensional interwoven distribution of the collagen deposits, with improved contrast compared to confocal microscopy. It also provided structural capability in intact corneas because of its high specificity to fibrillar collagen, with substantially larger field of view than transmission electron microscopy. Moreover, in vivo SHG imaging was demonstrated in Goto-Kakizaki rats. CONCLUSIONS/SIGNIFICANCE: Our study shows unambiguously the high potential of SHG microscopy for three-dimensional characterization of structural abnormalities in unstained corneas. Furthermore, our demonstration of in vivo SHG imaging opens the way to long-term dynamical studies. This method should be easily generalized to other structural remodeling of the cornea and SHG microscopy should prove to be invaluable for in vivo corneal pathological studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anaplastic lymphoma kinase (ALK) rearrangements represents a new driver oncogenic event in non-small cell lung cancer (NSCLC). ALK positive patients account for a 1-7% of NSCLC patients. The objective of this study is to know the prevalence and clinical characteristics of ALK positive patients in a cohort of NSCLC patients and to compare inmunohistochemistry with D5F3 monoclonal antibody with gold standard method fluorescence in situ hybridation

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to evaluate the direct-method test of sensitivity to drugs used in the principal tuberculosis treatment regimes, in the Organon Teknika MB/BacT system, we tested 50 sputum samples positive to microscopy taken from patients with pulmonary tuberculosis and with clinical indications for an antibiogram, admitted sequentially for examination during the routine of the reference laboratory. The material was treated v/v with 23% trisodium phosphate solution, incubated for 24 h at 35°C, and neutralized v/v with 20% monosodium phosphate solution. The material was then centrifuged and the sediment inoculated into flasks containing Rifampin - 2 µg/ml, Isoniazid - 0.2 µg/ml, Pyrazinamide - 100 µg/ml, Ethambutol - 2.5 µg/ml, Ethionamide - 1.25 µg/ml, and Streptomycin - 2 µg/ml. The tests were evaluated using the indirect method in the BACTEC 460 TB (Becton Dickinson) system as the gold standard. The results showed that the Rifampin test performed best, i.e., 100% sensitivity at 95% Confidence Interval (82.2-100) and 100% specificity at 95% Confidence Interval (84.5-100), followed by Isoniazid and Pyrazinamide. In this experiment, 92% of the materials showed a final reading in 30 days; this period represents the time for primary isolation as well as the results of the sensitivity profile, and is within Centers for Disease Control and Prevention recommendations regarding time for performance of the antibiogram. The inoculated flasks showed no contamination during the experiment. The MB/BacT is shown to be a reliable, rapid, fully automated nonradiometric system for the tuberculosis antibiogram.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose of reviewThis review provides information and an update on stereotactic radiosurgery (SRS) equipment, with a focus on intracranial lesions and brain neoplasms.Recent findingsGamma Knife radiosurgery represents the gold standard for intracranial radiosurgery, using a dedicated equipment, and has recently evolved with a newly designed technology, Leksell Gamma Knife Perfexion. Linear accelerator-based radiosurgery is more recent, and originally based on existing systems, either adapted or dedicated to radiosurgery. Equipment incorporating specific technologies, such as the robotic CyberKnife system, has been developed. Novel concepts in radiation therapy delivery techniques, such as intensity-modulated radiotherapy, were also developed; their integration with computed tomography imaging and helical delivery has led to the TomoTherapy system. Recent data on the management of intracranial tumors with radiosurgery illustrate the trend toward a larger use and acceptance of this therapeutic modality.SummarySRS has become an important alternative treatment for a variety of lesions. Each radiosurgery system has its advantages and limitations. The 'perfect' and ubiquitous system does not exist. The choice of a radiosurgery system may vary with the strategy and needs of specific radiosurgery programs. No center can afford to acquire every technology, and strategic choices have to be made. Institutions with large neurosurgery and radiation oncology programs usually have more than one system, allowing optimization of the management of patients with a choice of open neurosurgery, radiosurgery, and radiotherapy. Given its minimally invasive nature and increasing clinical acceptance, SRS will continue to progress and offer new advances as a therapeutic tool in neurosurgery and radiotherapy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La manometría convencional es el “gold standard” para diagnosticar trastornos motores del esófago, pero la información que da sobre la repercusión funcional de estas alteraciones es escasa. La manometría de alta resolución permite estudiar con detalle la motilidad esofagogástrica mediante la generación de mapas topográficos de presiones desde la orofaringe hasta el estómago. Hipótesis: Si la generación de mapas topográficos de presiones en el esófago mediante manometría de alta resolución demuestra la resistencia al flujo esofagogástrico. Objetivo: Comprobar si un test con sobrecarga de agua puede mostrar la presencia de resistencia al flujo esofagogástrico en pacientes con acalasia. Método: Estudiamos 2 grupos de pacientes con alteración de la motilidad esofágica. Un grupo de 8 pacientes que cumplen criterios manométricos de acalasia y, como grupo control, 8 pacientes con disfunción del peristaltismo esofágico ( DPE). A cada paciente se le realizó un test de sobrecarga que consistía en la ingesta rápida de 200 ml de agua mientras se registraban las presiones esofágicas. Resultados: Los pacientes con acalasia ingirieron el agua más lentamente que los pacientes con DPE (82± 14 seg vs 34± 6 seg, p&0,05). Mientras la unión gastroesofágica (UGE) permaneció contraída en el grupo de pacientes con acalasia (46,6± 6 mm Hg; p&0,05), permaneció relajada durante el tiempo del ingesta en pacientes con DPE ( 16,6 ± 4,7 mm Hg). La unión esófago-gástrica (UGE) experimentó una migración proximal en pacientes con acalasia de 1,3 ± 0 cm mientras que en el grupo control no migró (0 cm; p&0,05). La ingesta de agua se asoció a un incremento de la presión del esófago distal (2 cm por encima de la UGE) significativamente mayor en los pacientes con acalasia que en los pacientes con DPE (42,2 ± 20 vs 9,5± 7,9 mm Hg respectivamente, p&0,05) lo que produjo un incremento del gradiente de presión esófago-gástrico en pacientes con acalasia (16± 0,9 mmHg) que no se observó en los pacientes con DPE (0,1 ± 0,4 mmHg ; p&0,05). Conclusión: Un test con sobrecarga de agua durante la medición de la topografía y de las presiones esofágicas demuestra obstrucción al flujo esofagogástrico en los pacientes con acalasia. Este test podría contribuir a valorar la repercusión funcional en pacientes con acalasia y podría servir para el seguimiento de pacientes con acalasia tratados.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A total of 106 women with vaginitis in Nicaragua were studied. The positive rate for the identification of Candida species was 41% (44 positive cultures out of 106 women with vaginitis). The sensitivity of microscopic examination of wet mount with the potassium hydroxide (KOH) was 61% and 70% with Gram's stain when using the culture of vaginal fluid as gold standard for diagnosis of candidiasis. Among the 44 positives cultures, isolated species of yeast from vaginal swabs were C. albicans (59%), C. tropicalis (23%), C. glabrata (14%) and C. krusei (4%). This study reports the first characterization of 26 C. albicans stocks from Nicaragua by the random amplified polymorphic DNA method. The genetic analysis in this small C. albicans population showed the existence of linkage disequilibrium, which is consistent with the hypothesis that C. albicans undergoes a clonal propagation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, the use of Mtp-40 and alpha antigen polymerase chain reaction (PCR) amplification fragments for the precise tuberculosis (TB) diagnosis was evaluated. One hundred and ninety two different samples were obtained from 113 patients with suspected TB. Mtp-40 and alpha antigen protein genes were amplified by the PCR technique and compared to both the "gold standard" (culture) test, as well as the clinical parameters (including a clinical record and X-ray film exam in 113 patients). Thirty-eight of the 113 patients had a presumptive clinical diagnosis of TB; 74% being detected by PCR technique, 58% by culture and 44% by direct microscopic visualization. Weconclude that it is possible to use PCR as a suitable technique for the detection of any mycobacteria by means of the alpha antigen product, or the specific infection of Mycobacterium tuberculosis by means of the mtp-40 gene. This might be a good supporting tool in difficult clinical TB diagnosis and pauci-bacillary cases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to compare a novel compressed sensing (CS)-based single-breath-hold multislice magnetic resonance cine technique with the standard multi-breath-hold technique for the assessment of left ventricular (LV) volumes and function. BACKGROUND: Cardiac magnetic resonance is generally accepted as the gold standard for LV volume and function assessment. LV function is 1 of the most important cardiac parameters for diagnosis and the monitoring of treatment effects. Recently, CS techniques have emerged as a means to accelerate data acquisition. METHODS: The prototype CS cine sequence acquires 3 long-axis and 4 short-axis cine loops in 1 single breath-hold (temporal/spatial resolution: 30 ms/1.5 × 1.5 mm(2); acceleration factor 11.0) to measure left ventricular ejection fraction (LVEFCS) as well as LV volumes and LV mass using LV model-based 4D software. For comparison, a conventional stack of multi-breath-hold cine images was acquired (temporal/spatial resolution 40 ms/1.2 × 1.6 mm(2)). As a reference for the left ventricular stroke volume (LVSV), aortic flow was measured by phase-contrast acquisition. RESULTS: In 94% of the 33 participants (12 volunteers: mean age 33 ± 7 years; 21 patients: mean age 63 ± 13 years with different LV pathologies), the image quality of the CS acquisitions was excellent. LVEFCS and LVEFstandard were similar (48.5 ± 15.9% vs. 49.8 ± 15.8%; p = 0.11; r = 0.96; slope 0.97; p < 0.00001). Agreement of LVSVCS with aortic flow was superior to that of LVSVstandard (overestimation vs. aortic flow: 5.6 ± 6.5 ml vs. 16.2 ± 11.7 ml, respectively; p = 0.012) with less variability (r = 0.91; p < 0.00001 for the CS technique vs. r = 0.71; p < 0.01 for the standard technique). The intraobserver and interobserver agreement for all CS parameters was good (slopes 0.93 to 1.06; r = 0.90 to 0.99). CONCLUSIONS: The results demonstrated the feasibility of applying the CS strategy to evaluate LV function and volumes with high accuracy in patients. The single-breath-hold CS strategy has the potential to replace the multi-breath-hold standard cardiac magnetic resonance technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Roux-en-Y gastric bypass (RYGBP)-essentially a restrictive bariatric procedure-is currently considered the gold standard for the surgical treatment of morbid obesity. Open surgery in obese patients is associated with a high risk of cardiopulmonary complications, wound infection, and late incisional hernia. Laparoscopic surgery has been shown to reduce perioperative morbidity and to improve postoperative recovery for various procedures. Herein we present our results with laparoscopic RYGBP after an initial 2-year experience. METHODS: A prospective database was created in our department beginning without the first laparoscopic bariatric procedure. To provide a complete follow-up of 6 months, the results of all patients operated on between June 1999 and August 2001 were reviewed. Early surgical results, weight loss, correction of comorbidities, and improvement of quality of life were evaluated. RESULTS: A total of 107 patients were included. There were 82 women and 25 men, with a mean age of 39.7 years (range, 19-58). RYGBP was a primary procedure in 80 cases (49 morbidly obese and 31 superobese patients) and a reoperation after failure or complication of another bariatric operation in 27 cases. Mean duration of surgery was 168 min for morbidly obese patients, 196 min for surperobese patients, and 205 min for reoperated patients (p <0.01). Conversion to open surgery was necessary in two cases. A total of 22 patients (20.5%) developed complication. Nine of them (8.4%) required reoperation for leak (five cases, or 4.6%), bowel occlusion (three cases, or 2.8%), or subphrenic abscess (one case, or 0.9%). mortality was 0.9%. Major morbidity decreased over time (first two-thirds, 12.5%, last third, 2.7%). major morbidity decreased over time (first two-thirds, 12.5%; last third, 2.7%). Excess weight loss of -50% was achieved in >80% of the patients, corresponding to a loss of 15 body mass index (BMI) units in morbidly obese patients and 20 BMI units in superobese patients. In the vast majority of patients, comorbidities improved or disappeared over time and quality of life improved. CONCLUSIONS: Laparoscopic Roux-en-Y gastric bypass is feasible, but it is a very complex operation. Indeed, it is associated with a long and steep learning curve, as reflected in the high number of major complications among our first 70 patients. The learning curve probably includes between 100 and 150 patients. With increasing experience, the morbidity rate becomes more acceptable and comparable to that of open RYGBP. The results in terms of weight loss and correction of comorbidities are similar to those obtained after open surgery, at least in the short term. However, only surgeons with extensive experience in advanced laparoscopic as well as bariatric surgery should attempt this procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Photopsias are unformed luminous spontaneous visual hallucinations, often described as flickering or wiggling lights, sometimes like a glare. Phosphenes are more intense and of shorter duration whereas migraine fortifications have a specific time course and succession of events. Recognition of this symptom is often poor, hence patients are wrongly investigated. PURPOSE: To describe the clinical presentation and electroretinographic characteristics of patients with photopsias. METHODS: 4 patients were worked-up with clinical, psychophysical, angiographic and electroretinographic examinations. RESULTS: Despite normal fundus and angiographic examinations, full-field electroretinogram was diagnostic in all cases. Retinal dysfunction involved either inner or outer retina. Paraneoplastic, and probable autoimmune/inflammatory retinopathies were found in our cases. CONCLUSION: Photopsias are often secondary to sick retinal cells. In the presence of photopsias, investigations should be directed towards the retina and electroretinography is the gold standard. Recognition of the symptom should prevent useless and potentially harmful investigations for the patient.