898 resultados para eye lens
Resumo:
Aims: To survey eye care practitioners from around the world regarding their current practice for anterior eye health recording to inform guidelines on best practice. Methods: The on-line survey examined the reported use of: word descriptions, sketching, grading scales or photographs; paper or computerised record cards and whether these were guided by proforma headings; grading scale choice, signs graded, level of precision, regional grading; and how much time eye care practitioners spent on average on anterior eye health recording. Results: Eight hundred and nine eye care practitioners from across the world completed the survey. Word description (p <. 0.001), sketches (p = 0.002) and grading scales (p <. 0.001) were used more for recording the anterior eye health of contact lens patients than other patients, but photography was used similarly (p = 0.132). Of the respondents, 84.5% used a grading scale, 13.5% using two, with the original Efron (51.6%) and CCLRU/Brien-Holden-Vision-Institute (48.5%) being the most popular. The median features graded was 11 (range 1-23), frequency from 91.6% (bulbar hyperaemia) to 19.6% (endothelial blebs), with most practitioners grading to the nearest unit (47.4%) and just 14.7% to one decimal place. The average time taken to report anterior eye health was reported to be 6.8. ±. 5.7. min, with the maximum time available 14.0. ±. 11. min. Conclusions: Developed practice and research evidence allows best practice guidelines for anterior eye health recording to be recommended. It is recommended to: record which grading scale is used; always grade to one decimal place, record what you see live rather than based on how you intend to manage a condition; grade bulbar and limbal hyperaemia, limbal neovascularisation, conjunctival papillary redness and roughness (in white light to assess colouration with fluorescein instilled to aid visualisation of papillae/follicles), blepharitis, meibomian gland dysfunction and sketch staining (both corneal and conjunctival) at every visit. Record other anterior eye features only if they are remarkable, but indicate that the key tissue which have been examined.
Resumo:
Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.
Resumo:
Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.
Resumo:
Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.
Resumo:
The literature suggests that diabetic patients may have altered tear chemistry and tear secretion as well as structural and functional changes to the corneal epithelium, endothelium and nerves. These factors, together with a reported increased incidence of corneal infection, suggest that diabetic patients may be particularly susceptible to developing ocular complications during contact lens wear. Reports of contact lens-induced complications in diabetic patients do exist, although a number of these reports concern patients with advanced diabetic eye disease using lenses on an extended wear basis. Over the past decade or so, there have been published studies documenting the response of the diabetic eye to more modern contact lens modalities. The results of these studies suggest that contact lenses can be a viable mode of refractive correction for diabetic patients. Furthermore, new research suggests that the measurement of tear glucose concentration could, in future, be used to monitor metabolic control non-invasively in diabetic patients. This could be carried out using contact lenses manufactured from hydrogel polymers embedded with glucose-sensing agents or nanoscale digital electronic technology. The purpose of this paper is to review the literature on the anterior ocular manifestations of diabetes, particularly that pertaining to contact lens wear. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.
Resumo:
Lipids play a vital role in the body at many interfaces. Examples include the lubrication of articulating joints by synovial fluid, the coating of the lung by pulmonary surfactant and the functions of the tear film in the protection of the anterior eye. The role of the lipids is similar at each site - acting as boundary lubricants and reducing surface and interfacial tension. This review focuses on how and why contact lens wear can disrupt the normal function of lipids within the tear film and explains how the otherwise advantageous presence and function of tear lipids can become disadvantageous, causing problems for the wearer. Because the contact lens is some ten times thicker than the tear film, lipids deposited on the anterior surface become immobilised, reducing lipid turnover and thus leading to prolonged exposure to oxygen and light with consequent generation of degradation products. These degraded lipids reduce lens wettability and have additionally been linked to problems of contact lens discomfort and intolerance. Lipid problems are influenced by the thickness of the lens, the material, surface modification, mode of wear and ultimately the subject. The most influential of these variables is frequently the subject. © 2012.
Resumo:
Presbyopia is a consequence of ageing and is therefore increasing inprevalence due to an increase in the ageing population. Of the many methods available to manage presbyopia, the use of contact lenses is indeed a tried and tested reversible option for those wishing to be spectacle free. Contact lens options to correct presbyopia include multifocal contact lenses and monovision.Several options have been available for many years with available guides to help choose multifocal contact lenses. However there is no comprehensive way to help the practitioner selecting the best option for an individual. An examination of the simplest way of predicting the most suitable multifocal lens for a patient will only enhance and add to the current evidence available. The purpose of the study was to determine the current use of presbyopic correction modalities in an optometric practice population in the UK and to evaluate and compare the optical performance of four silicone hydrogel soft multifocal contact lenses and to compare multifocal performance with contact lens monovision. The presbyopic practice cohort principal forms of refractive correction were distance spectacles (with near and intermediate vision providedby a variety of other forms of correction), varifocal spectacles and unaided distance with reading spectacles, with few patients wearing contact lenses as their primary correction modality. The results of the multifocal contact lens randomised controlled trial showed that there were only minor differences in corneal physiology between the lens options. Visual acuity differences were observed for distance targets, but only for low contrast letters and under mesopic lighting conditions. At closer distances between 20cm and 67cm, the defocus curves demonstrated that there were significant differences in acuity between lens designs (p < 0.001) and there was an interaction between the lens design and the level of defocus (p < 0.001). None of the lenses showed a clear near addition, perhaps due to their more aspheric rather than zoned design. As expected, stereoacuity was reduced with monovision compared with the multifocal contact lens designs, although there were some differences between the multifocal lens designs (p < 0.05). Reading speed did not differ between lens designs (F = 1.082, p = 0.368), whereas there was a significant difference in critical print size (F = 7.543, p < 0.001). Glare was quantified with a novel halometer and halo size was found to significantly differ between lenses(F = 4.101, p = 0.004). The rating of iPhone image clarity was significantly different between presbyopic corrections (p = 0.002) as was the Near Acuity Visual Questionnaire (NAVQ) rating of near performance (F = 3.730, p = 0.007).The pupil size did not alter with contact lens design (F = 1.614, p = 0.175), but was larger in the dominant eye (F = 5.489, p = 0.025). Pupil decentration relative to the optical axis did not alter with contact lens design (F = 0.777, p =0.542), but was also greater in the dominant eye (F = 9.917, p = 0.003). It was interesting to note that there was no difference in spherical aberrations induced between the contact lens designs (p > 0.05), with eye dominance (p > 0.05) oroptical component (ocular, corneal or internal: p > 0.05). In terms of subjective patient lens preference, 10 patients preferred monovision,12 Biofinity multifocal lens, 7 Purevision 2 for Presbyopia, 4 AirOptix multifocal and 2 Oasys multifocal contact lenses. However, there were no differences in demographic factors relating to lifestyle or personality, or physiological characteristics such as pupil size or ocular aberrations as measured at baseline,which would allow a practitioner to identify which lens modality the patient would prefer. In terms of the performance of patients with their preferred lens, it emerged that Biofinity multifocal lens preferring patients had a better high contrast acuity under photopic conditions, maintained their reading speed at smaller print sizes and subjectively rated iPhone clarity as better with this lens compared with the other lens designs trialled. Patients who preferred monovision had a lower acuity across a range of distances and a larger area of glare than those patients preferring other lens designs that was unexplained by the clinical metrics measured. However, it seemed that a complex interaction of aberrations may drive lens preference. New clinical tests or more diverse lens designs which may allow practitioners to prescribe patients the presbyopic contact lens option that will work best for them first time remains a hope for the future.
Resumo:
This study identifies and investigates the potential use of in-eye trigger mechanisms to supplement the widely available information on release of ophthalmic drugs from contact lenses under passive release conditions. Ophthalmic dyes and surrogates have been successfully employed to investigate how these factors can be drawn together to make a successful system. The storage of a drug-containing lens in a pH lower than that of the ocular environment can be used to establish an equilibrium that favours retention of the drug in the lens prior to ocular insertion. Although release under passive conditions does not result in complete dye elution, the use of mechanical agitation techniques which mimic the eyelid blink action in conjunction with ocular tear chemistry promotes further release. In this way differentiation between passive and triggered in vitro release characteristics can be established. Investigation of the role of individual tear proteins revealed significant differences in their ability to alter the equilibrium between matrix-held and eluate-held dye or drug. These individual experiments were then investigated in vivo using ophthalmic dyes. Complete elution was found to be achievable in-eye; this demonstrated the importance of that fraction of the drug retained under passive conditions and the triggering effect of in-eye conditions on the release process. Understanding both the structure-property relationship between drug and material and in-eye trigger mechanisms, using ophthalmic dyes as a surrogate, provides the basis of knowledge necessary to design ocular drug delivery vehicles for in-eye release in a controllable manner.
Resumo:
Purpose: To investigate how initial HEMA and silicone-hydrogel (SiHy) contact lens fit on insertion, which informs prescribing decisions, reflect end of day fit. Methods: Thirty participants (aged 22.9. ±. 4.9 years) were fitted contralaterally with HEMA and SiHy contact lenses. Corneal topography and tear break-up time were assessed pre-lens wear. Centration, lag, post-blink movement during up-gaze and push-up recovery speed were recorded after 5,10,20. min and 8. h of contact lens wear by a digital slit-lamp biomicroscope camera, along with reported comfort. Lens fit metrics were analysed using bespoke software. Results: Comfort and centration were similar with the HEMA and SiHy lenses (p > 0.05), but comfort decreased with time (p <. 0.01) whereas centration remained stable (F = 0.036, p = 0.991). Movement-on-blink and lag were greater with the HEMA than the SiHy lens (p <. 0.01), but movement-on-blink decreased with time after insertion (F = 22.423, p <. 0.001) whereas lag remained stable (F = 1.967, p = 0.129). Push-up recovery speed was similar with the HEMA and the SiHy lens 5-20. min after insertion (p > 0.05), but was slower with SiHy after 8. h wear (p = 0.016). Lens movement on blink and push-up recovery speed was predictive of the movement after 8. h of wear after 10-20. min SiHy wear, but after 5 to 20. min of HEMA lens wear. Conclusions: A HEMA or SiHy contact lens with poor movement on blink/push-up after at least 10. min after insertion should be rejected.
Resumo:
Keratoconus is a bilateral degenerative disease characterized by a non-inflammatory, progressive central corneal ectasia (typically asymmetric) and decreased vision. In its early stages it may be managed with spectacles and soft contact lenses but more commonly it is managed with rigid contact lenses. In advanced stages, when contact lenses can no longer be fit, have become intolerable, or corneal damage is severe, a penetrating keratoplasty is commonly performed. Alternative surgical techniques, such as the use of intra-stromal corneal ring segments (INTACS) have been developed to try and improve the fit of rigid contact lenses in keratoconic patients and avoid penetrating keratoplasties. This case report follows through the fitting of rigid contact lenses in an advanced keratoconic cornea after an INTACS procedure and discusses clinical findings, treatment options, and the use of mini-scleral and scleral lens designs as they relate to the challenges encountered in managing such a patient. Mini-scleral and scleral lenses are relatively easy to fit, and can be of benefit to many patients, including advanced keratoconic patients, post-INTAC patients and post-penetrating keratoplasty patients. © 2011 British Contact Lens Association.
Resumo:
PURPOSE: To determine the utility of a range of clinical and non-clinical indicators to aid the initial selection of the optimum presbyopic contact lens. In addition, to assess whether lens preference was influenced by the visual performance compared to the other designs trialled (intra-subject) or compared to participants who preferred other designs (inter-subject). METHODS: A double-masked randomised crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal and monovision was conducted on 35 presbyopes (54.3±6.2years). Participant lifestyle, personality, pupil characteristics and aberrometry were assessed prior to lens fitting. After 4 weeks of wear, high and low contrast visual acuity (VA) under photopic and mesopic conditions, reading speed, Near Activity Visual Questionnaire (NAVQ) rating, subjective quality-of-vision scoring, defocus curves, stereopsis, halometry, aberrometry and ocular physiology were quantified. RESULTS: After trialling all the lenses, preference was mixed (n=12 Biofinity, n=10 monovision, n=7 Purevision, n=4 Air Optix Aqua, n=2 Oasys). Lens preference was not dependent on personality (F=1.182, p=0.323) or the hours spent working at near (p=0.535) or intermediate (p=0.759) distances. No intersubject or strong intrasubject relationships emerged between lens preference and reading speed, NAVQ rating, halo size, aberrometry or ocular physiology (p>0.05). CONCLUSIONS: Participant lifestyle and personality, ocular optics, contact lens visual performance and ocular physiology provided poor indicators of the preferred lens type after 4 weeks of wear. This is confounded by the wide range of task visual demands of presbyopes and the limited optical differences between current multifocal contact lens designs.
Resumo:
Biotribology is essentially the study of friction, lubrication and wear in biological systems. The area has been widely studied in relation to the behaviour of synovial joints and the design and behaviour of hip joint prostheses, but only in the last decade have serious studies been extended to the eye. In the ocular environment - as distinct from articular joints - wear is not a major factor. Both lubrication and friction are extremely important, however; this is particularly the case in the presence of the contact lens, which is a medical device important not only in vision correction but also as a therapeutic bandage for the compromised cornea. This chapter describes the difficulty in replicating experimental conditions that accurately reflect the complex nature of the ocular environment together with the factors such as load and rate of travel of the eyelid, which is the principal moving surface in the eye. Results obtained across a range of laboratories are compared.
Resumo:
The successful design of polymers for contact lens applications depends on the ability to provide a balance of properties appropriate to the ocular environment. Principal relevant aspects of the anterior eye are the tear film, eyelid and cornea, which govern the requirements for surface properties, modulus and oxygen permeability, respectively. Permeability requirements and the developing view of the needs of the cornea, in terms of oxygen consumption and the particular roles of fluorine and silicon in the design of silicone hydrogels, which have proved to be the most successful family of materials for this demanding application, are discussed. The contact lens field is complicated by the fact that contact lenses are used in a range of wear modalities, the extremes of which can conveniently be classified as lenses that are disposed of at the end of a single period of daily wear and those used for 30. days of successive day-and-night periods, frequently referred to as extended or continuous wear. As silicone hydrogels developed, in the decade following their launch there has been a progressive trend in properties taking both modulus and water content closer to those of conventional hydrogels. This is particularly evident in the family of daily disposable contact lenses that have appeared since 2008.