992 resultados para conventional pigs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free-radical polymerization of methyl methacrylate and styrene using conventional organic initiators in the room temperature ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([ C(4)mim][PF6]) is rapid and produces polymers with molecular weights up to 10x higher than from benzene; both polymerization and isolation of products were achieved without using VOCs, offering economic as well as environmental advantages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: Currently, optimal use of virtual simulation for all treatment sites is not entirely clear. This study presents data to identify specific patient groups for whom conventional simulation may be completely eliminated and replaced by virtual simulation. Sampling and method: Two hundred and sixty patients were recruited from four treatment sites (head and neck, breast, pelvis, and thorax). Patients were randomly assigned to be treated using the usual treatment process involving conventional simulation, or a treatment process differing only in the replacement of conventional plan verification with virtual verification. Data were collected on set-up accuracy at verification, and the number of unsatisfactory verifications requiring a return to the conventional simulator. A micro-economic costing analysis was also undertaken, whereby data for each treatment process episode were also collected: number and grade of staff present, and the time for each treatment episode. Results: The study shows no statistically significant difference in the number of returns to the conventional simulator for each site and study arm. Image registration data show similar quality of verification for each study arm. The micro-costing data show no statistical difference between the virtual and conventional simulation processes. Conclusions: At our institution, virtual simulation including virtual verification for the sites investigated presents no disadvantage compared to conventional simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution.Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stem, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated.Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170o from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation.Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tubers of two cultivars (Estima and Maris Piper) of potato were cooked by three different procedures, ie boiling, conventional baking and microwave baking. Peeled and sliced tubers were boiled, while intact potatoes were baked in their skins. Flavour components from the boiled slices and the flesh of the baked tubers were isolated by headspace adsorption onto Tenax and analysed by gas chromatography-mass spectrometry (GC-MS). For all cooking procedures, Estima gave stronger isolates than Maris Piper. The two main sources of flavour compounds (regardless of cooking procedure) were lipid degradation and the Maillard reaction and/or sugar degradation. The ratio (yield derived from lipid)/(yield derived from Maillard reaction and/or sugar) decreased from 8.5-9.1 (boiling) to 2.7-3.4 (microwave baking) and to 0.4-1.1 (conventional baking). Quantitative and qualitative differences among the cooking procedures are explained in terms of the variations in heat and mass transfer processes that occurred. Each cooking procedure resulted in a unique profile of flavour compounds. (C) 2002 Society of Chemical Industry.