910 resultados para control and surveillance
Resumo:
Intermittent hemodialysis (IHD) and continuous renal replacement therapies (CRRT) are used as Acute Kidney Injury (AKI) therapy and have certain advantages and disadvantages. Extended daily dialysis (EDD) has emerged as an alternative to CRRT in the management of hemodynamically unstable AKI patients, mainly in developed countries.Objectives: We hypothesized that EDD is a safe option for AKI treatment and aimed to describe metabolic and fluid control of AKI patients undergoing EDD and identify complications and risk factors associated with death.Study Selection: This is an observational and retrospective study describing introduction of EDD at our institution. A total of 231 hemodynamically unstable AKI patients (noradrenalin dose between 0.3 and 1.0 ucg/kg/min) were assigned to 1367 EDD session. EDD consisted of 6-8 h of HD 6 days a week, with blood flow of 200 ml/min, dialysate flows of 300 ml/min.Data Synthesis: Mean age was 60.6 +/- 15.8 years, 97.4% of patients were in the intensive care unit, and sepsis was the main etiology of AKI (76.2). BUN and creatinine levels stabilized after four sessions at around 38 and 2.4 mg/dl, respectively. Fluid balance decreased progressively and stabilized around zero after five sessions. Weekly delivered Kt/V was 5.94 +/- 0.7. Hypotension and filter clotting occurred in 47.5 and 12.4% of treatment session, respectively. Regarding AKI outcome, 22.5% of patients presented renal function recovery, 5.6% of patients remained on dialysis after 30 days, and 71.9% of patients died. Age and focus abdominal sepsis were identified as risk factors for death. Urine output and negative fluid balance were identified as protective factors.Conclusions: EDD is effective for AKI patients, allowing adequate metabolic and fluid control. Age, focus abdominal sepsis, and lower urine output as well as positive fluid balance after two EDD sessions were associated significantly with death.
Resumo:
Objective To verify the effects of a systematized multimodal exercise intervention program on frontal cognitive function, postural control, and functional capacity components of individuals with Alzheimer's disease (AD).DesignNonrandomized controlled trial with pre- and posttraining tests in a training group and a control group.SettingKinesiotherapy program for seniors with AD, SAo Paulo State University.ParticipantsConvenience sample of older adults with AD (n=30) were assigned to a training (n=14; aged 78.67.1) and a control (n=16; aged 77.06.3) group.InterventionThe intervention program was structured with the aim of simultaneously promoting better balance and frontal cognitive capacity. The participants attended a 1-hour session three times a week for 16weeks, whereas the control group did not participate in any activity during the same period.MeasurementsFrontal cognitive function was evaluated using the Montreal Cognitive Assessment, the Clock Drawing Test, the Frontal Assessment Battery, and the Symbol Search Subtest. Postural control (center of pressure area) was analyzed under four dual-task conditions. Functional capacity components were analyzed using the Timed Up and Go Test, the 30-second sit-to-stand test, the sit-and-reach test, and the Berg Functional Balance Scale.ResultsIntervention group participants showed a significant increase in frontal cognitive function (P<.001, partial (2)=0.838), with less body sway (P=.04, partial (2)=0.04) during the dual tasks, and greater functional capacity (P=.001, partial (2)=0.676) after the 16-week period.ConclusionIntervention participants performed better on dual-task activities and had better postural balance and greater functional capacity than controls.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper describes the control, epidemiological, pathological, and molecular aspects of an outbreak of meningoencephalitis in calves due to bovine herpesvirus 5 at a feedlot with 540 animals in Sa (a) over tildeo Paulo State, Brazil. The introduction of new animals and contact between the resident animals and the introduced ones were most likely responsible for virus transmission. Bovine herpesvirus 1 vaccine was used, resulting in the efficacy of the outbreak control, although two bovine herpesvirus 1 positive animals, vaccinated and revaccinated, presented meningoencephalitis, thereby characterizing vaccinal failure.
Resumo:
Objective: This study aimed to analyze and compare the role of a water-based exercise program versus a combination of water and callisthenic exercises on postural control, functional independence, and freezing of gait (FOG) in patients with mild to moderate Parkinson disease.Methods: Twenty-five community-dwelling participants with idiopathic Parkinson disease were recruited. Of these, 9 participants took part in a water-based program of physical exercises and the other 16 participants took part in a combined program that consisted of callisthenic exercises plus an aquatic exercise session. Both programs were 16 weeks in duration. The clinical evaluation assessed the festination by means of the FOG score test; postural control was verified by means of the balance test of the short physical performance battery, and the Spanish validated version of the Unified Parkinson's Disease Rating Scale part 2 was used to assess functional independence. Participants were evaluated before and after 16 weeks of both proposed programs.Results: The results showed improvement in FOG for both groups, although a significant main effect was observed only in the patients who performed the callisthenic exercise plus an aquatic exercise program. Postural control did not show significant improvements after both proposed physical exercise programs as soon as functional autonomy. Our preliminary results suggest that training sessions with the combination of water plus callisthenic exercises may be a useful physical rehabilitation strategy for individuals with mild to moderate Parkinson disease who have FOG.
Resumo:
the aims of this study were to determine imazapyr efficacy for floating macrophyte control and ecotoxicology for non-target organisms. For the floating macrophyte control efficacy tests were used the doses of 0,5; 1,0; 2,0; 2,5; 3,0; 3,5 and 4,0 L ha(-1) and a control with 10 replicates. The acute toxicology for non-target organisms was estimated by lethal concentration 50% (LC50 and EC50). The floating macrophyte control efficacy was over 90%. Imazapyr was classified as moderately toxic for the following biomarkers: L. minor, H. eques, B. rerio, P. caudimaculatus, P. canaliculata, and P. mesopotamicus and lightly toxic for A. caroliniana. Thus, imazapyr herbicide is a tool with great potential to be used on floating macrophyte control (E. crassipes, P. stratiotes e S. molesta) in Brazil and this practice can be evaluated by the use of application biomarkers.
Resumo:
Aims. To quantify the presence of SCCmec types and virulence genes among Staphylococcus aureus colonizing and infecting patients from a teaching hospital. Methods. We analyzed 225 and 84 S. aureus isolates recovered from surveillance and clinical cultures, respectively. Strains were studied for the presence and type of SCCmec, as well as for several virulence genes. Univariate and multivariable analysis were performed in order to identify predictors of invasiveness (defined as isolation from clinical cultures). Results. The presence of SCCmec types III (OR, 2.19, 95% CI, 1.08-4.45) and IV (OR, 5.28 95% CI, 1.35-20.63) and of genes coding for exfoliative toxin B (etb, OR, 6.38, 95% CI, 1.48-27.46) and Panton-Valentine leukocidin (pvl, OR, 2.38, 95% CI, 1.16-4.86) was independently associated with invasiveness. Conclusions. SCCmec types III and IV and virulence genes are associated with greater invasiveness of S. aureus. Patients colonized with methicillin-resistant S. aureus, as well as with strains harboring etb or pvl, may be prone to develop invasive disease. Infection-preventing strategies should be more intensively applied to this group.
Resumo:
In this paper the dynamical interactions of a double pendulum arm and an electromechanical shaker is investigated. The double pendulum is a three degree of freedom system coupled to an RLC circuit based nonlinear shaker through a magnetic field, and the capacitor voltage is a nonlinear function of the instantaneous electric charge. Numerical simulations show the existence of chaotic behavior for some regions in the parameter space and this behaviour is characterized by power spectral density and Lyapunov exponents. The bifurcation diagram is constructed to explore the qualitative behaviour of the system. This kind of electromechanical system is frequently found in robotic systems, and in order to suppress the chaotic motion, the State-Dependent Riccati Equation (SDRE) control and the Nonlinear Saturation control (NSC) techniques are analyzed. The robustness of these two controllers is tested by a sensitivity analysis to parametric uncertainties.
Resumo:
Background: Exercise training is a non-pharmacological strategy for treatment of heart failure. Exercise training improves functional capacity and quality of life in patients. Moreover, exercise training reduces muscle sympathetic nerve activity (MSNA) and peripheral vasoconstriction. However, most of these studies have been conducted in middle-aged patients. Thus, the effects of exercise training in older patients are much less understood. The present study was undertaken to investigate whether exercise training improves functional capacity, muscular sympathetic activation and muscular blood flow in older heart failure patients, as it does in middle-aged heart failure patients. Design: Fifty-two consecutive outpatients with heart failure from the database of the Unit of Cardiovascular Rehabilitation and Physiology Exercise were divided by age (middle-aged, defined as 45-59 years, and older, defined as 60-75 years) and exercise status (trained and untrained). Methods: MSNA was recorded directly from the peroneal nerve using the microneurography technique. Forearm Blood Flow (FBF) was measured by venous occlusion plethysmography. Functional capacity was evaluated by cardiopulmonary exercise test. Results: Exercise training significantly and similarly increased FBF and peak VO2 in middle-aged and older heart failure patients. In addition, exercise training significantly and similarly reduced MSNA and forearm vascular resistance in these patients. No significant changes were found in untrained patients. Conclusion: Exercise training improves neurovascular control and functional capacity in heart failure patients regardless of age.
Resumo:
Existing studies of on-line process control are concerned with economic aspects, and the parameters of the processes are optimized with respect to the average cost per item produced. However, an equally important dimension is the adoption of an efficient maintenance policy. In most cases, only the frequency of the corrective adjustment is evaluated because it is assumed that the equipment becomes "as good as new" after corrective maintenance. For this condition to be met, a sophisticated and detailed corrective adjustment system needs to be employed. The aim of this paper is to propose an integrated economic model incorporating the following two dimensions: on-line process control and a corrective maintenance program. Both performances are objects of an average cost per item minimization. Adjustments are based on the location of the measurement of a quality characteristic of interest in a three decision zone. Numerical examples are illustrated in the proposal. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
This paper presents the new active absorption wave basin, named Hydrodynamic Calibrator (HC), constructed at the University of São Paulo (USP), in the Laboratory facilities of the Numerical Offshore Tank (TPN). The square (14 m 14 m) tank is able to generate and absorb waves from 0.5 Hz to 2.0 Hz, by means of 148 active hinged flap wave makers. An independent mechanical system drives each flap by means of a 1HP servo-motor and a ball-screw based transmission system. A customized ultrasonic wave probe is installed in each flap, and is responsible for measuring wave elevation in the flap. A complex automation architecture was implemented, with three Programmable Logic Computers (PLCs), and a low-level software is responsible for all the interlocks and maintenance functions of the tank. Furthermore, all the control algorithms for the generation and absorption are implemented using higher level software (MATLAB /Simulink block diagrams). These algorithms calculate the motions of the wave makers both to generate and absorb the required wave field by taking into account the layout of the flaps and the limits of wave generation. The experimental transfer function that relates the flap amplitude to the wave elevation amplitude is used for the calculation of the motion of each flap. This paper describes the main features of the tank, followed by a detailed presentation of the whole automation system. It includes the measuring devices, signal conditioning, PLC and network architecture, real-time and synchronizing software and motor control loop. Finally, a validation of the whole automation system is presented, by means of the experimental analysis of the transfer function of the waves generated and the calculation of all the delays introduced by the automation system.
Resumo:
Motion control is a sub-field of automation, in which the position and/or velocity of machines are controlled using some type of device. In motion control the position, velocity, force, pressure, etc., profiles are designed in such a way that the different mechanical parts work as an harmonious whole in which a perfect synchronization must be achieved. The real-time exchange of information in the distributed system that is nowadays an industrial plant plays an important role in order to achieve always better performance, better effectiveness and better safety. The network for connecting field devices such as sensors, actuators, field controllers such as PLCs, regulators, drive controller etc., and man-machine interfaces is commonly called fieldbus. Since the motion transmission is now task of the communication system, and not more of kinematic chains as in the past, the communication protocol must assure that the desired profiles, and their properties, are correctly transmitted to the axes then reproduced or else the synchronization among the different parts is lost with all the resulting consequences. In this thesis, the problem of trajectory reconstruction in the case of an event-triggered communication system is faced. The most important feature that a real-time communication system must have is the preservation of the following temporal and spatial properties: absolute temporal consistency, relative temporal consistency, spatial consistency. Starting from the basic system composed by one master and one slave and passing through systems made up by many slaves and one master or many masters and one slave, the problems in the profile reconstruction and temporal properties preservation, and subsequently the synchronization of different profiles in network adopting an event-triggered communication system, have been shown. These networks are characterized by the fact that a common knowledge of the global time is not available. Therefore they are non-deterministic networks. Each topology is analyzed and the proposed solution based on phase-locked loops adopted for the basic master-slave case has been improved to face with the other configurations.
Resumo:
60 strains (belonging to the genera Lactobacillus, Bifidobacterium, Leuconostoc and Enterococcus) were tested for their capacity to inhibit the growth of 3 strains of Campylobacter jejuni: Lactobacilli and bifidobacteria were left to grow in MRS or TPY broth at 37°C overnight in anaerobic conditions; Campylobacter jejuni was inoculated in blood agar plates at 37°C for 24-48 hours in microaerophilic conditions. The inhibition experiments were carried out in vitro using ”Spot agar test” and “Well diffusion assay” techniques testing both cellular activity and that of the surnatant. 11 strains proved to inhibit the growth of Campylobacter jejuni. These strains were subsequently analised analised in order to evaluate the resistance to particular situations of stress which are found in the gastrointestinal tract and during the industrial transformation processes (Starvation stress, osmotic stress, heat stress, resistance to pH and to bile salts). Resistance to starvation stress: all strains seemed to resist the stress (except one strain). Resistance to osmotic stress: all strains were relatively resistant to the concentrations of 6% w/v of NaCl (except one strain). Resistance to heat stress: only one strain showed little resistance to the 55°C temperature. Resistance to pH: In the presence of a low pH (2.5), many strains rapidly lost their viability after approximately 1 hour. Resistance to bile salts: Except for one strain, all strains seemed to be relatively resistant to the 2% w/v concentration of bile salts. Afterward, strains were identified by using phenotipic and molecular techniques. Phenotipic identification was carried out by using API 50 CHL (bioMérieux) and API 20 STREP identification system (bioMérieux); molecular identification with species-specific PCR: the molecular techniques confirmed the results by phenotipic identification. For testing the antibiotic resistance profile, bacterial strains were subcultured in MRS or TPY broth and incubated for 18 h at 37°C under anaerobic conditions. Antibiotics tested (Tetracycline, Trimethoprim, Cefuroxime, Kanamycin, Chloramphenicol, Vancomycin, Ampycillin, Sterptomycin, Erythromycin) were diluted to the final concentrations of: 2,4,8,16,32,64,128,256 mg/ml. Then, 20 μl fresh bacterial culture (final concentration in the plates approximately 106 cfu/ml) were added to 160 μl MRS or TPY broth and 20 μl antibiotic solution. As positive control the bacterial culture (20 ul) was added to broth (160 ul) and water (20 ul). Test was performed on plates P96, that after the inoculum were incubated for 24 h at 37oC, then the antibiotic resistance was determined by measuring the Optical Density (OD) at 620 nm with Multiscan EX. All strains showed a similar behaviour: resistance to all antibiotic tested. Further studies are needed.
Resumo:
Recently in most of the industrial automation process an ever increasing degree of automation has been observed. This increasing is motivated by the higher requirement of systems with great performance in terms of quality of products/services generated, productivity, efficiency and low costs in the design, realization and maintenance. This trend in the growth of complex automation systems is rapidly spreading over automated manufacturing systems (AMS), where the integration of the mechanical and electronic technology, typical of the Mechatronics, is merging with other technologies such as Informatics and the communication networks. An AMS is a very complex system that can be thought constituted by a set of flexible working stations, one or more transportation systems. To understand how this machine are important in our society let considerate that every day most of us use bottles of water or soda, buy product in box like food or cigarets and so on. Another important consideration from its complexity derive from the fact that the the consortium of machine producers has estimated around 350 types of manufacturing machine. A large number of manufacturing machine industry are presented in Italy and notably packaging machine industry,in particular a great concentration of this kind of industry is located in Bologna area; for this reason the Bologna area is called “packaging valley”. Usually, the various parts of the AMS interact among them in a concurrent and asynchronous way, and coordinate the parts of the machine to obtain a desiderated overall behaviour is an hard task. Often, this is the case in large scale systems, organized in a modular and distributed manner. Even if the success of a modern AMS from a functional and behavioural point of view is still to attribute to the design choices operated in the definition of the mechanical structure and electrical electronic architecture, the system that governs the control of the plant is becoming crucial, because of the large number of duties associated to it. Apart from the activity inherent to the automation of themachine cycles, the supervisory system is called to perform other main functions such as: emulating the behaviour of traditional mechanical members thus allowing a drastic constructive simplification of the machine and a crucial functional flexibility; dynamically adapting the control strategies according to the different productive needs and to the different operational scenarios; obtaining a high quality of the final product through the verification of the correctness of the processing; addressing the operator devoted to themachine to promptly and carefully take the actions devoted to establish or restore the optimal operating conditions; managing in real time information on diagnostics, as a support of the maintenance operations of the machine. The kind of facilities that designers can directly find on themarket, in terms of software component libraries provides in fact an adequate support as regard the implementation of either top-level or bottom-level functionalities, typically pertaining to the domains of user-friendly HMIs, closed-loop regulation and motion control, fieldbus-based interconnection of remote smart devices. What is still lacking is a reference framework comprising a comprehensive set of highly reusable logic control components that, focussing on the cross-cutting functionalities characterizing the automation domain, may help the designers in the process of modelling and structuring their applications according to the specific needs. Historically, the design and verification process for complex automated industrial systems is performed in empirical way, without a clear distinction between functional and technological-implementation concepts and without a systematic method to organically deal with the complete system. Traditionally, in the field of analog and digital control design and verification through formal and simulation tools have been adopted since a long time ago, at least for multivariable and/or nonlinear controllers for complex time-driven dynamics as in the fields of vehicles, aircrafts, robots, electric drives and complex power electronics equipments. Moving to the field of logic control, typical for industrial manufacturing automation, the design and verification process is approached in a completely different way, usually very “unstructured”. No clear distinction between functions and implementations, between functional architectures and technological architectures and platforms is considered. Probably this difference is due to the different “dynamical framework”of logic control with respect to analog/digital control. As a matter of facts, in logic control discrete-events dynamics replace time-driven dynamics; hence most of the formal and mathematical tools of analog/digital control cannot be directly migrated to logic control to enlighten the distinction between functions and implementations. In addition, in the common view of application technicians, logic control design is strictly connected to the adopted implementation technology (relays in the past, software nowadays), leading again to a deep confusion among functional view and technological view. In Industrial automation software engineering, concepts as modularity, encapsulation, composability and reusability are strongly emphasized and profitably realized in the so-calledobject-oriented methodologies. Industrial automation is receiving lately this approach, as testified by some IEC standards IEC 611313, IEC 61499 which have been considered in commercial products only recently. On the other hand, in the scientific and technical literature many contributions have been already proposed to establish a suitable modelling framework for industrial automation. During last years it was possible to note a considerable growth in the exploitation of innovative concepts and technologies from ICT world in industrial automation systems. For what concerns the logic control design, Model Based Design (MBD) is being imported in industrial automation from software engineering field. Another key-point in industrial automated systems is the growth of requirements in terms of availability, reliability and safety for technological systems. In other words, the control system should not only deal with the nominal behaviour, but should also deal with other important duties, such as diagnosis and faults isolations, recovery and safety management. Indeed, together with high performance, in complex systems fault occurrences increase. This is a consequence of the fact that, as it typically occurs in reliable mechatronic systems, in complex systems such as AMS, together with reliable mechanical elements, an increasing number of electronic devices are also present, that are more vulnerable by their own nature. The diagnosis problem and the faults isolation in a generic dynamical system consists in the design of an elaboration unit that, appropriately processing the inputs and outputs of the dynamical system, is also capable of detecting incipient faults on the plant devices, reconfiguring the control system so as to guarantee satisfactory performance. The designer should be able to formally verify the product, certifying that, in its final implementation, it will perform itsrequired function guarantying the desired level of reliability and safety; the next step is that of preventing faults and eventually reconfiguring the control system so that faults are tolerated. On this topic an important improvement to formal verification of logic control, fault diagnosis and fault tolerant control results derive from Discrete Event Systems theory. The aimof this work is to define a design pattern and a control architecture to help the designer of control logic in industrial automated systems. The work starts with a brief discussion on main characteristics and description of industrial automated systems on Chapter 1. In Chapter 2 a survey on the state of the software engineering paradigm applied to industrial automation is discussed. Chapter 3 presentes a architecture for industrial automated systems based on the new concept of Generalized Actuator showing its benefits, while in Chapter 4 this architecture is refined using a novel entity, the Generalized Device in order to have a better reusability and modularity of the control logic. In Chapter 5 a new approach will be present based on Discrete Event Systems for the problemof software formal verification and an active fault tolerant control architecture using online diagnostic. Finally conclusive remarks and some ideas on new directions to explore are given. In Appendix A are briefly reported some concepts and results about Discrete Event Systems which should help the reader in understanding some crucial points in chapter 5; while in Appendix B an overview on the experimental testbed of the Laboratory of Automation of University of Bologna, is reported to validated the approach presented in chapter 3, chapter 4 and chapter 5. In Appendix C some components model used in chapter 5 for formal verification are reported.