745 resultados para contact lenses


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Various strategies for ocular drug delivery are considered; from basic formulation techniques for improving availability of drugs; viscosity enhancers and mucoadhesives aid drug retention and penetration enhancers promote drug transport into the eye. The use of drug loaded contact lenses and ocular inserts allows drugs to be better placed where they are needed for more direct delivery. Developments in ocular implants gives a means to overcome the physical barriers that traditionally prevented effective treatment. Implant technologies are under development allowing long term drug delivery from a single procedure, these devices allow posterior chamber diseases to be effectively treated. Future developments could bring artificial corneas to eliminate the need for donor tissue and one-off implantable drug depots lasting the patient’s lifetime.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hydrogels have become very popular due to their unique properties such as high water content, softness, flexibility and biocompatibility. Natural and synthetic hydrophilic polymers can be physically or chemically cross-linked in order to produce hydrogels. Their resemblance to living tissue opens up many opportunities for applications in biomedical areas. Currently, hydrogels are used for manufacturing contact lenses, hygiene products, tissue engineering scaffolds, drug delivery systems and wound dressings. This review provides an analysis of their main characteristics and biomedical applications. From Wichterle’s pioneering work to the most recent hydrogel-based inventions and products on the market, it provides the reader with a detailed introduction to the topic and perspective on further potential developments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: We described the rate of Acanthamoeba keratitis (AK) in a referral eye center in Sao Paulo, Brazil, through a retrospective review of clinical and laboratorial records of patients over 2 decades. Methods: From 1987 to 2006, a total of 581 requests for amoebic laboratory workup in cases of infections keratitis were investigated. Statistical analyses were applied to analyze a tendency of AK cases. Results: Acanthamoeba species were cultured from corneal scrapings of 185 patients, 5 of them with bilateral infection. Eighty-three percent of those patients were related with contact lens wear. Conclusions: The results suggested that patients with AK have persisted and increased over time at our ophthalmology center. Contact lenses showed to be a potential risk factor. Amoebic corneal infection can be considered as a new but well-established disease ill Brazilian ophthalmology and visual sciences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Analisar o perfil dos usuários de lentes de contato entre os estudantes de medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), quanto à ametropia, à aquisição, aos cuidados e às complicações. MÉTODOS: Foi aplicado um questionário aos alunos do 1º ao 6º ano de Medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), perfazendo um estudo analítico transversal. RESULTADOS: Foram 566 entrevistados. Destes, 155 (27,4%) usavam lente de contato. Das lentes de contato usadas, 94,8% eram gelatinosas, e em 98,7% o grau era negativo. O descarte dessas lentes era mensal em 46,9% dos entrevistados e 63,9% a utilizavam, em média, 14 horas/dia. Faziam aquisição da lente de contato em óptica ou farmácia 14,1% dos estudantes. Faziam a higiene ao colocá-las e ao retirá-las dos olhos, 46,5%. As complicações referentes aos olhos vermelhos eram 51,0%; 44,5%, embaçamento; e 42,6%, sensação de corpo estranho, além de 4 estudantes relatarem ceratite. CONCLUSÕES: A maioria dos alunos utilizava lentes hidrofílicas, descarte mensal e grau negativo. A adaptação inadequada, aquisição de lentes de contato em ópticas ou farmácias e complicações graves ocorreram, mesmo nos usuários socioculturalmente considerados diferenciados. em vista disso, demanda a extrema necessidade de maior atenção na abordagem do tema em questão, a fim de prevenir o comprometimento visual permanente.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To analyze the conditions, consequences and risks of self-medication in patients attended in ophthalmology emergency room at Hospital das Clínicas de Botucatu (UNESP). Methods: Sixty patients who had used any form of self-medication were studied according: age, sex, professional activity, mainly complain, visual acuity (best-corrected vision), who administrated the self-medication (friends/parents, pharmacy clerk, advertisement, or the person himself), sort of medication or product used (eyedrops/ointments/contact lenses), cost (R$), time expenditure to medical attention, ocular complications, risk of visual loss and final diagnose. Results: The majority of patients with self-medication were male (72%). The mean age was 40,9 years (7-77 years). Patients usually used eyedrops that they had at home and delayed 3 days to the first medical evaluation. The most frequently kind of topical eyedrop used was vasoconstrictor (17%). However, many patients even knew what kind of medication they had dropped in their eyes (21%). The great majority of the patients (68%) were exposed to the risk of visual loss. According to our results, self-medication may cause visual complications in 12% of patients, in which, 42% was related to the contact lenses fit without ophthalmologic assistance. Conclusion: The majory of the patients used medication that they had in home. The topical vasoconstrictor was the most frequently used drug, however, they did not know which medication were dropping in their eyes (21%).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the roughness of colorless ocular button and four brands of colorless acrylic resins designed to fabricate ocular prosthesis as a function of weathering (1008 h) and different thickness (1 and 3.5 mm). Materials and methods: One-hundred-and-twenty specimens were fabricated and distributed in 12 groups. The analysis was carried out by means of digital roughness meter. Results: Data were analyzed statistically by ANOVA and Tukey test at 1% significance. The results showed that there was no statistically significant difference after the weathering period. Both the Vipi Cril acrylic resin with 3.5 mm in thickness and ocular button with 1 mm in thickness presented the lowest roughness values (0.12. Ra). Conclusion: The roughness of the acrylic resins and the ocular button was not affect by the weathering of 1008 h. However, the thickness of the specimens proved to have a major influence on roughness property. © 2010.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hydrogels are used in a variety of applications in daily life, such as super absorbers, contact lenses and in drug delivery. Functional hydrogels that allow the incorporation of additional functionalities have enormous potential for future development. The properties of such hydrogels can be diversified by introducing responsiveness to external stimuli. These crosslinked polymers are known to respond to changes in temperature, pH and pressure, as well as chemical and electrical stimuli, magnetic fields and irradiation. From this responsive behavior possible applications arise in many fields like drug delivery, tissue engineering, purification and implementation as actuators, biosensors or for medical coatings. However, their interaction with biomaterial and way of functioning are yet not fully understood. Therefore, thorough investigations regarding their optical, mechanical and chemical nature have to be conducted. A UV-crosslinkable polymer, consisting of N-isopropylacrylamide, methacrylic acid and the UV-crosslinker 4-benzoylphenyl methacrylate was synthesized. Its composition, determined by a comprehensive NMR study, is equivalent to the composition of the monomer mixture. The chemical characteristics were preserved during the subsequently formation of hydrogel films by photo-crosslinking as proved by XPS. For the optical characterization, e.g. the degree of swelling of very thin films, the spectroscopy of coupled long range surface plasmons is introduced. Thicker films, able to guide light waves were analyzed with combined surface plasmon and optical waveguide mode spectroscopy (SPR/OWS). The evaluation of the data was facilitated by the reverse Wentzel-Kramers-Brillouin (WKB) approximation. The meshsize and proper motion of the surface anchored hydrogels were investigated by fluorescence correlation spectroscopy (FCS), micro photon correlation spectroscopy (µPCS) and SPR/OWS. The studied gels exhibit a meshsize that allowed for the diffusion of small biomolecules inside their network. For future enhancement of probing diffusants, a dye that enables FRET in FCS was immobilized in the gel and the diffusion of gold-nanoparticles embedded in the polymer solution was studied by PCS. These properties can be conveniently tuned by the crosslinking density, which depends on the irradiation dose. Additionally, protocols and components for polymer analogous reactions based on active ester chemistry of the hydrogel were developed. Based on these syntheses and investigations, the hydrogel films are applied in the fields of medical coatings as well as in biosensing as matrix and biomimetic cushion. Their non-adhesive properties were proved in cell experiments, SPR/OWS and ToF-SIMS studies. The functionality and non-fouling property of the prepared hydrogels allowed for adaption to the needs of the respective application.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Although it seems plausible that sports performance relies on high-acuity foveal vision, it could be empirically shown that myoptic blur (up to +2 diopters) does not harm performance in sport tasks that require foveal information pick-up like golf putting (Bulson, Ciuffreda, & Hung, 2008). How myoptic blur affects peripheral performance is yet unknown. Attention might be less needed for processing visual cues foveally and lead to better performance because peripheral cues are better processed as a function of reduced foveal vision, which will be tested in the current experiment. Methods: 18 sport science students with self-reported myopia volunteered as participants, all of them regularly wearing contact lenses. Exclusion criteria comprised visual correction other than myopic, correction of astigmatism and use of contact lenses out of Swiss delivery area. For each of the participants, three pairs of additional contact lenses (besides their regular lenses; used in the “plano” condition) were manufactured with an individual overcorrection to a retinal defocus of +1 to +3 diopters (referred to as “+1.00 D”, “+2.00 D”, and “+3.00 D” condition, respectively). Gaze data were acquired while participants had to perform a multiple object tracking (MOT) task that required to track 4 out of 10 moving stimuli. In addition, in 66.7 % of all trials, one of the 4 targets suddenly stopped during the motion phase for a period of 0.5 s. Stimuli moved in front of a picture of a sports hall to allow for foveal processing. Due to the directional hypotheses, the level of significance for one-tailed tests on differences was set at α = .05 and posteriori effect sizes were computed as partial eta squares (ηρ2). Results: Due to problems with the gaze-data collection, 3 participants had to be excluded from further analyses. The expectation of a centroid strategy was confirmed because gaze was closer to the centroid than the target (all p < .01). In comparison to the plano baseline, participants more often recalled all 4 targets under defocus conditions, F(1,14) = 26.13, p < .01, ηρ2 = .65. The three defocus conditions differed significantly, F(2,28) = 2.56, p = .05, ηρ2 = .16, with a higher accuracy as a function of a defocus increase and significant contrasts between conditions +1.00 D and +2.00 D (p = .03) and +1.00 D and +3.00 D (p = .03). For stop trials, significant differences could neither be found between plano baseline and defocus conditions, F(1,14) = .19, p = .67, ηρ2 = .01, nor between the three defocus conditions, F(2,28) = 1.09, p = .18, ηρ2 = .07. Participants reacted faster in “4 correct+button” trials under defocus than under plano-baseline conditions, F(1,14) = 10.77, p < .01, ηρ2 = .44. The defocus conditions differed significantly, F(2,28) = 6.16, p < .01, ηρ2 = .31, with shorter response times as a function of a defocus increase and significant contrasts between +1.00 D and +2.00 D (p = .01) and +1.00 D and +3.00 D (p < .01). Discussion: The results show that gaze behaviour in MOT is not affected to a relevant degree by a visual overcorrection up to +3 diopters. Hence, it can be taken for granted that peripheral event detection was investigated in the present study. This overcorrection, however, does not harm the capability to peripherally track objects. Moreover, if an event has to be detected peripherally, neither response accuracy nor response time is negatively affected. Findings could claim considerable relevance for all sport situations in which peripheral vision is required which now needs applied studies on this topic. References: Bulson, R. C., Ciuffreda, K. J., & Hung, G. K. (2008). The effect of retinal defocus on golf putting. Ophthalmic and Physiological Optics, 28, 334-344.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It has been known for more than 40 years that images fade from perception when they are kept at the same position on the retina by abrogating eye movements. Although aspects of this phenomenon were described earlier, the use of close-fitting contact lenses in the 1950s made possible a series of detailed observations on eye movements and visual continuity. In the intervening decades, many investigators have studied the role of image motion on visual perception. Although several controversies remain, it is clear that images deteriorate and in some cases disappear following stabilization; eye movements are, therefore, essential to sustained exoptic vision. The time course of image degradation has generally been reported to be a few seconds to a minute or more, depending upon the conditions. Here we show that images of entoptic vascular shadows can disappear in less than 80 msec. The rapid vanishing of these images implies an active mechanism of image erasure and creation as the basis of normal visual processing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundamentos: El elevado número de personas que trabajando con ordenador utiliza lentes de contacto plantea la cuestión sobre si la suma de estos dos factores de riesgo para la salud visual puede originar un agravamiento del Síndrome Visual Informático. El objetivo de esta revisión es sintetizar el conocimiento científico sobre las alteraciones oculares y visuales relacionadas con la exposición a ordenador en usuarios de lentes de contacto. Métodos: Revisión de artículos científicos (2003-2013) en español e inglés, realizando una búsqueda bibliográfica, en Medline a través de PubMed y en Scopus. Resultados: La búsqueda inicial aportó 114 trabajos, después de aplicar criterios de inclusión/exclusión se incluyeron seis artículos. Todos ellos ponen de manifiesto que las alteraciones al utilizar el ordenador son más frecuentes en las personas usuarias de lentes de contacto, con prevalencias que oscilan de 95,0% al 16,9% que en las que no utilizan lentes de contacto, cuya prevalencia va del 57,5% al 9,9% y con una probabilidad cuatro veces mayor de padecer ojo seco [OR: 4,07 (IC 95%: 3,52-4,71)]. Conclusiones: Las personas usuarias de ordenador padecen más alteraciones oculares y visuales cuando además son usuarias de lentes de contacto, pero los estudios son escasos y poco contundentes. Se precisan nuevas investigaciones que analicen la influencia según los tipos de lentes y sus condiciones de uso, tanto en la sintomatología como en la calidad de la lágrima y la superficie ocular. Las lentes de hidrogel de silicona son las que se asocian a mayor confort.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate and characterize the clinical profile of young asymptomatic or minimally symptomatic patients without diagnosis of dry eye but showing signs compatible with dry eye syndrome (DES). Methods: Prospective study including a total of 50 consecutive subjects with ages ranging from 18 to 40 years that were identified as asymptomatic or minimally symptomatic by means of the Ocular Surface Disease Index (OSDI) (score of <22). In all patients, a complete battery of tests for the diagnosis of DES was performed including the evaluation of the tear film break-up time (TFBUT), the level of corneal and conjunctival staining, and the eyelid and Meibomian morphology. Results: The OSDI score was significantly higher in women than in men (median: 12.5 vs. 5.3, P=0.01). Low grades of ocular surface staining, dysfunction of Meibomian gland expression, and alteration of quality of Meibomian secretions were observed in 56%, 58%, and 84% of eyes, respectively. More eyes with some dysfunction of Meibomian gland expressibility had a TFBUT less than 5 sec (P=0.033). A statistically significant difference in the OSDI score was found between patients with and without systemic allergies (P=0.036) and between male and female (P=0.01). Likewise, the OSDI score was significantly higher in those women wearing contact lenses compared with those not wearing them (P=0.012). Conclusions: Asymptomatic or minimally symptomatic young subjects may present low grades of clinical signs compatible with DES, with a trend to more symptomatology in women and allergic patients. These outcomes should be confirmed in future studies with larger samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’utilisation de lentilles cornéennes peut servir à améliorer le profil d’administration d’un principe actif dans les yeux. Avec une efficacité d’administration de 5% par l’utilisation de gouttes, on comprend rapidement que l’administration oculaire doit être améliorée. Cette faible administration a donné naissance à plusieurs tentatives visant à fabriquer des lentilles cornéennes médicamentées. Cependant, à cause de multiples raisons, aucune de ces tentatives n’a actuellement été mise sur le marché. Nous proposons dans cette étude, une possible amélioration des systèmes établis par le développement d’une lentille cornéenne à base de 2-(hydroxyéthyle)méthacrylate (HEMA), dans laquelle des microgels, à base de poly N-isopropylacrylamide (pNIPAM) thermosensible encapsulant un principe actif, seront incorporé. Nous avons donc débuté par développer une méthode analytique sensible par HPCL-MS/MS capable de quantifier plusieurs molécules à la fois. La méthode résultante a été validée selon les différents critères de la FDA et l’ICH en démontrant des limites de quantifications et de détections suffisamment basses, autant dans des fluides simulés que dans les tissus d’yeux de lapins. La méthode a été validée pour sept médicaments ophtalmiques : Pilocarpine, lidocaïne, proparacaïne, atropine, acétonide de triamcinolone, timolol et prednisolone. Nous avons ensuite fait la synthèse des microgels chargés négativement à base de NIPAM et d’acide méthacrylique (MAA). Nous avons encapsulé une molécule modèle dans des particules ayant une taille entre 200 et 600 nm dépendant de la composition ainsi qu’un potentiel zêta variant en fonction de la température. L’encapsulation de la rhodamine 6G (R6G) dans les microgels a été possible jusqu’à un chargement (DL%) de 38%. L’utilisation des isothermes de Langmuir a permis de montrer que l’encapsulation était principalement le résultat d’interactions électrostatiques entre les MAA et la R6G. Des cinétiques de libérations ont été effectuées à partir d’hydrogels d’acrylamide chargés en microgels encapsulant la R6G. Il a été trouvé que la libération des hydrogels chargés en microgels s’effectuait majoritairement selon l’affinité au microgel et sur une période d’environ 4-24 heures. La libération à partir de ces systèmes a été comparée à des formules d’hydrogels contenant des liposomes ou des nanogels de chitosan. Ces trois derniers (liposomes, microgels et nanogels) ont présenté des résultats prometteurs pour différentes applications avec différents profils de libérations. Enfin, nous avons transposé le modèle développé avec les gels d’acrylamide pour fabriquer des lentilles de contact de 260 à 340 µm d’épaisseur à base de pHEMA contenant les microgels avec une molécule encapsulée devant être administrée dans les yeux. Nous avons modifié la composition de l’hydrogel en incorporant un polymère linéaire, la polyvinylpyrrolidone (PVP). L’obtention d’hydrogels partiellement interpénétrés améliore la rétention d’eau dans les lentilles cornéennes. L’encapsulation dans les microgels chargés négativement a donné de meilleurs rendements avec la lidocaïne et cette dernière a été libérée de la lentille de pHEMA en totalité en approximativement 2 heures qu’elle soit ou non encapsulée dans des microgels. Ainsi dans cette étude pilote, l’impact des microgels n’a pas pu être déterminé et, de ce fait, nécessitera des études approfondies sur la structure et les propriétés de la lentille qui a été développée. En utilisant des modèles de libération plus représentatifs de la physiologie de l’œil, nous pourrions conclure avec plus de certitude concernant l’efficacité d’un tel système d’administration et s’il est possible de l’optimiser.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The precipitation patterns and characteristics of calcium phosphate (CaP) phases deposited on HEMA-based hydrogels upon incubation in simulated body fluid (SBF-2) containing a protein (human serum albumin) have been investigated in relation to the calcification in an organic-free medium (SBF-1) and to that occurring after subcutaneous implantation in rats. In SBF-2, the deposits occurred exclusively as a peripheral layer on the surface of the hydrogels and consisted mainly of precipitated hydroxyapatite, a species deficient in calcium and hydroxyl ions, similarly to the deposits formed on the implanted hydrogels, where the deposited layer was thicker. In SBF-1, the deposits were mainly of brushite type. There was no evidence that albumin penetrated the interstices of hydrogels. As the X-ray diffraction patterns of the CaP deposits generated in SBF-2 showed a similar nature with those formed on the implanted hydrogel, it was concluded that the calcification in SBF-2 can mimic to a reliable extent the calcification process taking place in a biological environment.