949 resultados para collection system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Four sizes (0.095, 0.53, 1.0 and 2.01 μm) of polystyrene latex particles were used to prepare monodispersed suspensions at three different ionic strengths (10−3, 10−2.5 and 10−2M KCl). Filtration experiments were conducted using those suspensions in a filter column with glass beads as porous medium. The filter bed depth and the filtration velocity were kept at 5 cm and 1 m/h, respectively. When suspensions with equal mass concentrations (0.2 mg/L) or equal surface area concentrations (0.12 cm2/mL) were filtered through the system, the largest particles exhibited higher initial single collector efficiency, η. The difference between the η of largest particles and the smaller particles was prominent for suspensions with equal surface area concentrations at higher ionic strengths. The collision efficiency, α of those particles exhibits higher values at higher ionic strengths. Both at equal mass concentration and equal surface area concentration, α is only slightly dependent on particle sizes when compared to its dependence on ionic strength. Further, it was found that the specific surface coverage was similar for 0.095 μm, 0.53 μm and 1.0 μm particles during the transient stage of filtration at any ionic strength when the surface area concentrations of those suspension were equal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This collection contributes to, advances and consolidates discussions of the range of methods and approaches in criminology through the presentation of diverse international case studies in which the authors reflect upon their experiences ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immobility plus preexisting chronic disease or acute trauma can activate the coagulation system, thus increasing the risk for thromboembolic events. The effects of long-term bed-rest immobility and microgravity on the coagulation system of healthy persons (e.g., during crewed Mars missions) have not yet been studied. The main objective of the second Berlin BedRest Study (BBR2-2) "Coagulation Part" was to investigate adaptations of the hemostatic system during long-term bed rest (60 days) under simulated microgravity (6° head-down-tilt [6°HDT]) and after mobilization in three different volunteer groups (randomly assigned to CTR= inactive control group; RE= resistive exercise only group; and RVE= resistive exercise with whole-body vibration group). In 24 males (aged 21-45 years), before, during, and after long-term bed rest, key parameters of coagulation were measured from venous blood samples: D-dimer (DD), thrombin-antithrombin III complex (TAT), and prothrombin fragment F1 + 2 (PT-F1 + 2). Additionally, modified rotational thrombelastometry (ROTEM (®) ) analysis was performed. Times of exploratory analyses were as follows: baseline data collection 2 days before bed rest (BDC-2); eight different days of 6°HDT bed rest (HDT1-HDT60), and two different days after reambulation (R + 3 and R + 6). We found significant changes in DD, TAT, and PT-F1 + 2 over the total time course, but no consistent effect of physical interventions (RE, RVE) on these parameters. Notably, no parameter reached levels indicative of intravascular thrombin formation. All ROTEM® parameters remained within the normal range and no pathological traces were found. Sixty days of 6°HDT bed rest are not associated with pronounced activation of the coagulation system indicative of intravascular thrombus formation in healthy volunteers independent of the training type during the bed rest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Case volume per 100 000 population and perioperative mortality rate (POMR) are key indicators to monitor and strengthen surgical services. However, comparisons of POMR have been restricted by absence of standardised approaches to when it is measured, the ideal denominator, need for risk adjustment, and whether data are available. We aimed to address these issues and recommend a minimum dataset by analysing four large mixed surgical datasets, two from well-resourced settings with sophisticated electronic patient information systems and two from resource-limited settings where clinicians maintain locally developed databases. METHODS: We obtained data from the New Zealand (NZ) National Minimum Dataset, the Geelong Hospital patient management system in Australia, and purpose-built surgical databases in Pietermaritzburg, South Africa (PMZ) and Port Moresby, Papua New Guinea (PNG). Information was sought on inclusion and exclusion criteria, coding criteria, and completeness of patient identifiers, admission, procedure, discharge and death dates, operation details, urgency of admission, and American Society of Anesthesiologists (ASA) score. Date-related errors were defined as missing dates and impossible discrepancies. For every site, we then calculated the POMR, the effect of admission episodes or procedures as denominator, and the difference between in-hospital POMR and 30-day POMR. To determine the need for risk adjustment, we used univariate and multivariate logistic regression to assess the effect on relative POMR for each site of age, admission urgency, ASA score, and procedure type. FINDINGS: 1 365 773 patient admissions involving 1 514 242 procedures were included, among which 8655 deaths were recorded within 30 days. Database inclusion and exclusion criteria differed substantially. NZ and Geelong records had less than 0·1% date-related errors and greater than 99·9% completeness. PMZ databases had 99·9% or greater completeness of all data except date-related items (94·0%). PNG had 99·9% or greater completeness for date of birth or age and admission date and operative procedure, but 80-83% completeness of patient identifiers and date related items. Coding of procedures was not standardised, and only NZ recorded ASA status and complete post-discharge mortality. In-hospital POMR range was 0·38% in NZ to 3·44% in PMZ, and in NZ it underestimated 30-day POMR by roughly a third. The difference in POMR by procedures instead of admission episodes as denominator ranged from 10% to 70%. Age older than 65 years and emergency admission had large independent effects on POMR, but relatively little effect in multivariate analysis on the relative odds of in-hospital death at each site. INTERPRETATION: Hospitals can collect and provide data for case volume and POMR without sophisticated electronic information systems. POMR should initially be defined by in-hospital mortality because post-discharge deaths are not usually recorded, and with procedures as denominator because details allowing linkage of several operations within one patient's admission are not always present. Although age and admission urgency are independently associated with POMR, and ASA and case mix were not included, risk adjustment might not be essential because the relative odds between sites persisted. Standardisation of inclusion criteria and definitions is needed, as is attention to accuracy and completeness of dates of procedures, discharge and death. A one-page, paper-based form, or alternatively a simple electronic data collection form, containing a minimum dataset commenced in the operating theatre could facilitate this process. FUNDING: None.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sharing sensor data between multiple devices and users can be^challenging for naive users, and requires knowledge of programming and use of different communication channels and/or development tools, leading to non uniform solutions. This thesis proposes a system that allows users to access sensors, share sensor data and manage sensors. With this system we intent to manage devices, share sensor data, compare sensor data, and set policies to act based on rules. This thesis presents the design and implementation of the system, as well as three case studies of its use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cutting analysis is a important and crucial task task to detect and prevent problems during the petroleum well drilling process. Several studies have been developed for drilling inspection, but none of them takes care about analysing the generated cutting at the vibrating shale shakers. Here we proposed a system to analyse the cutting's concentration at the vibrating shale shakers, which can indicate problems during the petroleum well drilling process, such that the collapse of the well borehole walls. Cutting's images are acquired and sent to the data analysis module, which has as the main goal to extract features and to classify frames according to one of three previously classes of cutting's volume. A collection of supervised classifiers were applied in order to allow comparisons about their accuracy and efficiency. We used the Optimum-Path Forest (OPF), Artificial Neural Network using Multi layer Perceptrons (ANN-MLP), Support Vector Machines (SVM) and a Bayesian Classifier (BC) for this task. The first one outperformed all the remaining classifiers. Recall that we are also the first to introduce the OPF classifier in this field of knowledge. Very good results show the robustness of the proposed system, which can be also integrated with other commonly system (Mud-Logging) in order to improve the last one's efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In 2000, the eight Millennium Development Goals (MDGs) set targets for reducing child mortality and improving maternal health by 2015.Objective: To evaluate the results of a new education and referral system for antenatal/intrapartum care as a strategy to reduce the rates of Cesarean sections (C-sections) and maternal/perinatal mortality.Methods: Design: Cross-sectional study. Setting: Department of Gynecology and Obstetrics, Botucatu Medical School, São Paulo State University/UNESP, Brazil. Population: 27,387 delivering women and 27,827 offspring. Data collection: maternal and perinatal data between 1995 and 2006 at the major level III and level II hospitals in Botucatu, Brazil following initiation of a safe motherhood education and referral system. Main outcome measures: Yearly rates of C-sections, maternal (/100,000 LB) and perinatal (/1000 births) mortality rates at both hospitals. Data analysis: Simple linear regression models were adjusted to estimate the referral system's annual effects on the total number of deliveries, C-section and perinatal mortality ratios in the two hospitals. The linear regression were assessed by residual analysis (Shapiro-Wilk test) and the influence of possible conflicting observations was evaluated by a diagnostic test (Leverage), with p < 0.05.Results: Over the time period evaluated, the overall C-section rate was 37.3%, there were 30 maternal deaths (maternal mortality ratio = 109.5/100,000 LB) and 660 perinatal deaths (perinatal mortality rate = 23.7/1000 births). The C-section rate decreased from 46.5% to 23.4% at the level II hospital while remaining unchanged at the level III hospital. The perinatal mortality rate decreased from 9.71 to 1.66/1000 births and from 60.8 to 39.6/1000 births at the level II and level III hospital, respectively. Maternal mortality ratios were 16.3/100,000 LB and 185.1/100,000 LB at the level II and level III hospitals. There was a shift from direct to indirect causes of maternal mortality.Conclusions: This safe motherhood referral system was a good strategy in reducing perinatal mortality and direct causes of maternal mortality and decreasing the overall rate of C-sections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a preconcentration and separation system based on continuous flow hydride generation is proposed to improve the determination of As and Se by total reflection X-ray fluorescence spectrometry. The generated hydrides are continuously separated from the liquid phase and collected in a chamber containing 250 mul of HCI/HNO3 1:1 (v/v) solution. Hydride generation conditions and collection of the hydrides were evaluated. Under optimised conditions, enrichment factors of 55 for As and 82 for Se were attained. Detection limits of 0.3 mug l(-1) for As and Se were obtained when 20 ml of sample was used. Analysis of a natural water standard reference material from National Institute of Standard and Technology (SRM-1640) was in agreement with the certified values at the 95% confidence level. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several studies are being conducted to assess the toxicity and cytotoxicity of water bodies receiving industrial and domestic effluents, using the Allium cepa test. To assess the toxicity and mutagenicity of water possibly contaminated with chromium, derived from tannery activities, seasonal water samplings were performed in 2001 and 2002 at five different sites along the Sapucaizinho river, Municipality of Patrocinio Paulista, State of São Paulo, Brazil. A. cepa seeds were used as the test material and were submitted to germination in waters from the different collection sites, in Milli-Q water (negative control) and in aqueous solution of chromium (positive control). For the determination of cell division rates and mitotic irregularities, slides were prepared with root tip cells according to the standard Feulgen methodology. The results showed that the collection sites most heavily compromised by chromium emission presented low mitotic indices and a higher frequency of mitotic changes such as irregular anaphases (disorganized, multipolar, laggard), cells with chromosomal adherences, cells with micronuclei, and binucleate and/or multinucleate cells. © 2004 The Japan Mendel Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The computational program called GIS_EM (Geographic Information System for Environmental Monitoring), a software devised to manage geographic information for monitoring soil, surface, and ground water, developed for use in the Health, Safety, and Environment Division of Paulinia Refinery is presented. This program enables registering and management of alphanumeric information pertaining to specific themes such as drilling performed for sample collection and for installation of monitoring wells, geophysical and other tests, results of chemical analyses of soil, surface, and groundwater, as well as reference values providing orientation for soil and water quality, such as EPA, Dutch List, etc. Management of such themes is performed by means of alphanumeric search tools, with specific filters and, in the case of spatial search, through the selection of spatial elements (themes) in map view. Documents existing in digital form, such as reports, photos, maps, may be registered and managed in the network environment. As the system centralizes information generated upon environmental investigations, it expedites access to and search of documents produced and stored in the network environment, minimizing search time and the need to file printed documents. This is an abstract of a paper presented at the AIChE Annual Meeting and Fall Showcase (Cincinnati, OH 10/30/2005-11/4/2005).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the ABO genotypes and heterogeneity of the O alleles in Plasmodium falciparum-infected and non-infected individuals from the Brazilian Amazon region. Sample collection took place from May 2003 to August 2005, from P. falciparum malaria patients from four endemic regions of the Brazilian Amazon. The control group consisted of donors from four blood banks in the same areas. DNA was extracted using the Easy-DNA(TM) extraction kit. ABO genotyping was performed using PCR/RFLP. There was a high frequency of ABO*O01O01. ABO*AO01 was the second most frequent genotype, and the third most frequent genotype was ABO*BO01. There were low frequencies of the ABO*O01O02, ABO*AA, ABO*AB, ABO*BB, and ABO*O02O02 genotypes. We analyzed the alleles of the O phenotype; the O(1variant) allele was the most frequent, both in malaria and non-malaria groups; consequently, the homozygous genotype O(1)(v)O(1)(v) was the most frequently observed. There was no evidence of the homozygous O(2) allele. Significant differences were not detected in the frequency of individuals with the various alleles in the comparison of the malaria patients and the general population (blood donors).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Malicious programs (malware) can cause severe damage on computer systems and data. The mechanism that the human immune system uses to detect and protect from organisms that threaten the human body is efficient and can be adapted to detect malware attacks. In this paper we propose a system to perform malware distributed collection, analysis and detection, this last inspired by the human immune system. After collecting malware samples from Internet, they are dynamically analyzed so as to provide execution traces at the operating system level and network flows that are used to create a behavioral model and to generate a detection signature. Those signatures serve as input to a malware detector, acting as the antibodies in the antigen detection process. This allows us to understand the malware attack and aids in the infection removal procedures. © 2012 Springer-Verlag.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an Advanced Traveler Information System (ATIS) developed on Android platform, which is open source and free. The developed application has as its main objective the free use of a Vehicle-to- Infrastructure (V2I) communication through the wireless network access points available in urban centers. In addition to providing the necessary information for an Intelligent Transportation System (ITS) to a central server, the application also receives the traffic data close to the vehicle. Once obtained this traffic information, the application displays them to the driver in a clear and efficient way, allowing the user to make decisions about his route in real time. The application was tested in a real environment and the results are presented in the article. In conclusion we present the benefits of this application. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The factors that have influence on the energy consumption of a small air conditioning system that are worth mentioning are the efficiencies of the compressor, evaporator and condenser, the form that the refrigerant flow is controlled, the fan model used, and climatic conditions. Within the climate issue, an interesting factor is that the relative humidity when it comes to the effect that it causes, especially in the performance of the air condenser, which generally is not considered in the projects. This study aims to evaluate the influence of humidity on the coefficient of system performance (COP), seeking to quantify their influence when it happens. The tests were performed on a testing bench, mounted at the Laboratory for Energy Efficiency (LAMOTRIZ) UNESP-Campus Guaratinguetá. In the study, the wet bulb temperature was ranged, keeping the rotation of the scroll compressor with application of a frequency inverter in its best performance. The test bench is provided with a supervisory system of data collection that is also able to control all functions of the bench. In the results, there was a significant influence, particularly when comparing high humidity conditions with low humidity, noting that only over 65% relative humidity is that significant changes are observed in the COP of the system. © 2013 Elsevier Inc.