959 resultados para chest-wall rigidity
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.
Resumo:
Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE). Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluated visual image quality. Dose was measured using CT-Expo. Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images. Conclusion: SAFIRE 5 was optimal for dose reduction and image quality.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Biomédica. A presente dissertação foi desenvolvida no Erasmus Medical Center em Roterdão, Holanda
Resumo:
Objective - Evaluate preventable exposure dose in routine chest CT examinations beyond prescribed anatomical landmarks and estimate extra dose delivered to the patient. Background/rationale - Recent technical advances have greatly increased the clinical applications of CT; developments in multidetector-row CT (MDCT) technology have occurred; the major disadvantage with the increased use of MDCT is associated radiation exposure.
Resumo:
Purpose - To develop and validate a psychometric scale for assessing image quality for chest radiographs.
Resumo:
The first case of mediastinal and pulmonary entomophthoromycosis with supe rior vena cava syndrome is reported. The patient presented with a history of edema of the face, neck and upper limbs as well as collateral circulation in the anterior wall of the chest. Histological examination of tissue from mediastinum revealed a granulomatous reaction with microabscesses surrounded by eosinophilic amorphous material and with broad hyphae in the center. Culture was not performed because a preliminary diagnosis of nonHodgkin's malignant lymphoma was made. Surgical correction of the obstructed area was performed and the patient was sucessfully treated with potassium iodide. The authors propose that mediastinal entomoph thoromycosis must be considered in the differential diagnosis of diseases causing superior vena cava syndrome in tropical and sub-tropical regions. This case enlarges the spectrum of clinical manifestations of the zigomycosis caused by Entomoph-thoraceae.
Resumo:
The authors report three patients with subcutaneous erythematous nodules in different phases of development, inespecific systemic symptoms, positive PPD test, and normal chest X-rays. The histopathological study of the older nodules showed a granulomatous arteritis with a few acid-fast bacilli in the vascular wall. The nodules at an early phase showed an inespecific panniculitis with some acid-fast bacilli in apparently normal cutaneous vessels. These findings suggest that the mycobacterium has a vascular tropism and may cause a primary granulomatous arteritis.
Resumo:
The interest of the study on the implementation of expanded agglomerated cork as exterior wall covering derives from two critical factors in a perspective of sustainable development: the use of a product consisting of a renewable natural material-cork-and the concern to contribute to greater sustainability in construction. The study aims to assess the feasibility of its use by analyzing the corresponding behaviour under different conditions. Since this application is relatively recent, only about ten years old, there is still much to learn about the reliability of its long-term properties. In this context, this study aims to deepen and approach aspects, some of them poorly studied and even unknown, that deal with characteristics that will make the agglomerate a good choice for exterior wall covering. The analysis of these and other characteristics is being performed by testing both under actual exposure conditions, on an experimental cell at LNEC, and on laboratory. In this paper the main laboratory tests are presented and the obtained results are compared with the outcome of the field study. © (2015) Trans Tech Publications, Switzerland.
Resumo:
Coccidioidomycosis is an endemic infection with a relatively limited geographic distribution: Mexico, Guatemala, Honduras, Colombia, Venezuela, Bolivia, Paraguai, Argentina and the southwest of the United States. In these countries, the endemic area is restricted to the semiarid desert like regions which are similar to the northeast of Brazil. Case report: The patient is a 32 year-old male, born in the state of Bahia (Northeast of Brazil) and has been living in São Paulo (Southeast) for 6 years. He was admitted at Hospital das Clínicas, at the Department of Pneumology in October 1996, with a 6 month history of progressive and productive cough, fever, malaise, chills, loss of weight, weakness and arthralgia in the small joints. Chest x-rays and computerized tomography disclosed an interstitial reticulonodular infiltrate with a cavity in the right upper lobe. The standard potassium hydroxide preparation of sputum and broncoalveolar lavage demonstrated the characteristic thickened wall spherules in various stages of development. Sabouraud dextrose agar, at 25° C and 30° C showed growth of white and cottony aerial micelium. The microscopic morphology disclosed branched hyphae characterized by thick walled, barrel shaped arthroconidia alternated with empty cells. The sorological studies with positive double immunodiffusion test, and also positive complement fixation test in 1/128 dilution confirmed the diagnosis. The patient has been treated with ketoconazole and presents a favorable clinical and radiological evolution
Resumo:
Lobo's disease is a chronic granulomatous disease caused by the obligate pathogenic fungus, whose cell walls contain constitutive melanin. In contrast, melanin does not occur in the cell walls of Paracoccidioides brasiliensis when stained by the Fontana-Masson stain.
Resumo:
Selenium modified ruthenium electrocatalysts supported on carbon black were synthesized using NaBH4 reduction of the metal precursor. Prepared Ru/C electrocatalysts showed high dispersion and very small averaged particle size. These Ru/C electrocatalysts were subsequently modified with Se following two procedures: (a) preformed Ru/carbon catalyst was mixed with SeO2 in xylene and reduced in H2 and (b) Ru metal precursor was mixed with SeO2 followed by reduction with NaBH4. The XRD patterns indicate that a pyrite-type structure was obtained at higher annealing temperatures, regardless of the Ru:Se molar ratio used in the preparation step. A pyrite-type structure also emerged in samples that were not calcined; however, in this case, the pyrite-type structure was only prominent for samples with higher Ru:Se ratios. The characterization of the RuSe/C electrocatalysts suggested that the Se in noncalcined samples was present mainly as an amorphous skin. Preliminary study of activity toward oxygen reduction reaction (ORR) using electrocatalysts with a Ru:Se ratio of 1:0.7 indicated that annealing after modification with Se had a detrimental effect on their activity. This result could be related to the increased particle size of crystalline RuSe2 in heat-treated samples. Higher activity of not annealed RuSe/C catalysts could also be a result of the structure containing amorphous Se skin on the Ru crystal. The electrode obtained using not calcined RuSe showed a very promising performance with a slightly lower activity and higher overpotential in comparison with a commercial Pt/C electrode. Single wall carbon nanohorns (SWNH) were considered for application as ORR electrocatalysts' supports. The characterization of SWNH was carried out regarding their tolerance toward strong catalyzed corrosion conditions. Tests indicated that SWNH have a three times higher electrochemical surface area (ESA) loss than carbon black or Pt commercial electrodes.
Resumo:
Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.