936 resultados para chest radiograph
Resumo:
Photograph
Resumo:
Background: Adherence to controller therapy in asthma is a major concern during the management of the disease. Objective: To determine the adherence rate and identify the predictors of low adherence to asthma controller therapy. Methods: A cross-sectional study including asthma patients was conducted from November 1, 2012 to May 31, 2013 in 4 chest clinics in Cameroon. The adherence to asthma treatment was rated using Morisky Medication Adherence Scale. A multivariate logistic regression analysis was performed for the identification of factors associated with adherence to asthma treatment. Results: Among the 201 asthma patients included, 133 (66.2%) were female. The mean age of participants was 41.2 years. Sixty-one (30.3%) of the patients did not visit the chest physician during the last year prior to the study. Asthma was well controlled in 118 patients (58.7%). The prevalence of low adherence rate to asthma controller therapy was 44.8% and the absence of any chest specialist visit within the last 12 months was the only factor associated with the low adherence rate to asthma treatment (OR 5.57 ; 95% CI 2.84–10.93). Conclusion: The adherence rate to asthma controller therapy in Cameroon is low and it could be improved if scheduled visits are respected by patients.
Resumo:
The background of this study is to assess the accuracy of lung ultrasound (LUS) to diagnose interstitial lung disease (ILD) in Sjögren’s syndrome (Sjs), in patients who have any alterations in pulmonary function tests (PFT) or respiratory symptoms. LUS was correlated with chest tomography (hrCT), considering it as the imaging gold standard technique to diagnose ILD. This is a pilot, multicenter, cross-sectional, and consecutive-case study. The inclusion criteria are ≥18 years old, Signs and symptoms: according to ACEG 2002 criteria, respiratory symptoms (dyspnea, cough), or any alterations in PFR. LUS was done following the International Consensus Conference on Lung Ultrasound protocol for interstitial syndrome (B pattern). Of the 50 patients in follow-up, 13 (26%) met the inclusion criteria. All were women with age 63.62 years (range 39–88). 78.6% of the cases had primary Sjs (SLE, RA, n = 2). The intra-rater reliability k is 1, according to Gwet’s Ac1 and GI index (probability to concordance—e(K)—, by Cohen, of 0.52). LUS has a sensitivity of 1 (95% CI 0.398–1.0), specificity of 0.89 (95% CI 0.518–0.997), and a positive probability reason of 9.00 (95% CI 7.1–11.3) to detect ILD. The correlation of Pearson is r = 0.84 (p < 0.001). To check the accuracy of LUS to diagnose ILD, a completely bilateral criterion of yes/no for interstitial pattern was chosen, AUC reaches significance, 0.94 (0.07) (95% CI 0.81–1.0, p = 0.014). LUS reaches an excellent correlation to hrCT in Sjs affected with ILD, and might be a useful technique in daily clinical practice for the assessment of pulmonary disease in the sicca syndrome. © 2016 SIMI
Resumo:
It is well known that rib cage dimensions depend on the gender and vary with the age of the individual. Under this setting it is therefore possible to assume that a computational approach to the problem may be thought out and, consequently, this work will focus on the development of an Artificial Intelligence grounded decision support system to predict individual’s age, based on such measurements. On the one hand, using some basic image processing techniques it were extracted such descriptions from chest X-rays (i.e., its maximum width and height). On the other hand, the computational framework was built on top of a Logic Programming Case Base approach to knowledge representation and reasoning, which caters for the handling of incomplete, unknown, or even contradictory information. Furthermore, clustering methods based on similarity analysis among cases were used to distinguish and aggregate collections of historical data in order to reduce the search space, therefore enhancing the cases retrieval and the overall computational process. The accuracy of the proposed model is satisfactory, close to 90%.
Resumo:
Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.
Resumo:
Over the last few years various research groups around the world have employed X-ray Computed Tomography (CT) imaging in the study of mummies – Toronto-Boston (1,2), Manchester(3). Prior to the development of CT scanners, plane X-rays were used in the investigation of mummies. Xeroradiography has also been employed(4). In a xeroradiograph, objects of similar X-ray density (very difficult to see on a conventional X-ray) appear edge-enhanced and so are seen much more clearly. CT scanners became available in the early 1970s. A CT scanner produces cross-sectional X-rays of objects. On a conventional X-radiograph individual structures are often very difficult to see because all the structures lying in the path of the X-ray beam are superimposed, a problem that does not occur with CT. Another advantage of CT is that the information in a series of consecutive images may be combined to produce a three-dimensional reconstruction of an object. Slices of different thickness and magnification may be chosen. Why CT a mummy? Prior to the availability of CT scanners, the only way of finding out about the inside of a mummy in any detail was to unwrap and dissect it. This has been done by various research groups – most notably the Manchester, UK and Pennsylvania University, USA mummy projects(5,6). Unwrapping a mummy and carrying out an autopsy is obviously very destructive. CT studies hold the possibility of producing a lot more information than is possible from plain X-rays and are able to show the undisturbed arrangement of the wrapped body. CT is also able to provide information about the internal structure of bones, organ packs, etc that wouldn’t be possible without sawing through the bones etc. The mummy we have scanned is encased in a coffin which would have to have been broken open in order to remove the body.
Resumo:
Scoliosis is a three-dimensional spinal deformity which requires surgical correction in progressive cases. In order to optimize correction and avoid complications following scoliosis surgery, patient-specific finite element models (FEM) are being developed and validated by our group. In this paper, the modeling methodology is described and two clinically relevant load cases are simulated for a single patient. Firstly, a pre-operative patient flexibility assessment, the fulcrum bending radiograph, is simulated to assess the model's ability to represent spine flexibility. Secondly, intra-operative forces during single rod anterior correction are simulated. Clinically, the patient had an initial Cobb angle of 44 degrees, which reduced to 26 degrees during fulcrum bending. Surgically, the coronal deformity corrected to 14 degrees. The simulated initial Cobb angle was 40 degrees, which reduced to 23 degrees following the fulcrum bending load case. The simulated surgical procedure corrected the coronal deformity to 14 degrees. The computed results for the patient-specific FEM are within the accepted clinical Cobb measuring error of 5 degrees, suggested that this modeling methodology is capable of capturing the biomechanical behaviour of a scoliotic human spine during anterior corrective surgery.
Resumo:
In the absence of telehealth technology, rural patients must travel to a regional or metropolitan hospital for a preadmission consultation one week before their surgery. Currently, examination of the patient’s chest using a stethoscope (auscultation) is not possible over a telehealth network as existing digital stethoscopes have been designed for in-person auscultation. We report on the initial phase of research which ultimately aims to design a digital stethoscope for use in the telehealth context. This initial research phase describes the complexity of the activity of preadmission clinics and the implications for the design of the stethoscope. The research is conducted through field studies of existing face-to-face and remote consultations.
Resumo:
Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Currently the treatment options for idiopathic scoliosis are observation, bracing and fusion. While brace treatment is non-invasive, and preserves the growth, motion, and function of the spine, it does not correct deformity and is only modestly successful in preventing curve progression. In adolescents who fail brace treatment, surgical treatment with an instrumented spinal fusion usually results in better deformity correction but is associated with substantially greater risk. Furthermore in younger patients requiring surgical treatment, fusion procedures are known to adversely effect the future growth of the chest and spine. Fusionless treatments have been developed to allow effective surgical treatment of patients with idiopathic scoliosis who are too young for fusion procedures. Anterior vertebral stapling is one such fusionless treatment which aims to modulate the growth of vertebra to allow correction of scoliosis whilst maintaining normal spinal motion The Mater Misericordiae Hospital in Brisbane has begun to use anterior vertebral stapling to treat patients with idiopathic scoliosis who are too young for fusion procedures. Currently the only staple approved for clinical use is manufactured by Medtronic Sofamor Danek (Memphis, TN). This thesis explains the biomechanical and anatomical changes that occur following anterior vertebral staple insertion using in vitro experiments performed on an immature bovine model. Currently there is a paucity of published information about anterior vertebral stapling so it is hoped that this project will provide information that will aid in our understanding of the clinical effects of staple insertion. The aims of this experimental study were threefold. The first phase was designed to determine the changes in the bending stiffness of the spine following staple insertion. The second phase was designed to measure the forces experienced by the staple during spinal movements. The third and final phase of testing was designed to describe the structural changes that occur to a vertebra as a consequence of staple insertion. The first phase of testing utilised a displacement controlled testing robot to compare the change in stiffness of a single spinal motion segment following staple insertion for the three basic spinal motions of flexion-extension, lateral bending, and axial rotation. For the second phase of testing strain gauges were attached to staples and used to measure staple forces during spinal movement. In the third and final phase the staples were removed and a testing specimen underwent micro-computed tomography (CT) scanning to describe the anatomical changes that occur following staple insertion. The displacement controlled testing showed that there was a significant decrease in bending stiffness in flexion, extension, lateral bending away from the staple, and axial rotation away from the staple following staple insertion. The strain gauge measurements showed that the greatest staple forces occurred in flexion and the least in extension. In addition, a reduction in the baseline staple compressive force was seen with successive loading cycles. Micro-CT scanning demonstrated that significant damage to the vertebral body and endplate occurred as a consequence of staple insertion. The clinical implications of this study are significant. Based on the findings of this project it is likely that the clinical effect of the anterior vertebral staple evaluated in this project is a consequence of growth plate damage (also called hemiepiphysiodesis) causing a partial growth arrest of the vertebra rather than simply compression of the growth plate. The surgical creation of a unilateral growth arrest is a well established treatment used in the management of congenital scoliosis but has not previously been considered for use in idiopathic scoliosis.
Resumo:
X-ray computed tomography (CT) is a medical imaging technique that produces images of trans-axial planes through the human body. When compared with a conventional radiograph, which is an image of many planes superimposed on each other, a CT image exhibits significantly improved contrast although this is at the expense of reduced spatial resolution.----- A CT image is reconstructed mathematically from a large number of one dimensional projections of the chosen plane. These projections are acquired electronically using a linear array of solid-state detectors and an x ray source that rotates around the patient.----- X-ray computed tomography is used routinely in radiological examinations. It has also be found to be useful in special applications such as radiotherapy treatment planning and three-dimensional imaging for surgical planning.
Resumo:
Patients with chest discomfort or other symptoms suggestive of acute coronary syndrome (ACS) are one of the most common categories seen in many Emergency Departments (EDs). While the recognition of patients at high-risk of ACS has improved steadily, identifying the majority of chest pain presentations who fall into the low-risk group remains a challenge. Research in this area needs to be transparent, robust, applicable to all hospitals from large tertiary centres to rural and remote sites, and to allow direct comparison between different studies with minimum patient spectrum bias. A standardised approach to the research framework using a common language for data definitions must be adopted to achieve this. The aim was to create a common framework for a standardised data definitions set that would allow maximum value when extrapolating research findings both within Australasian ED practice, and across similar populations worldwide. Therefore a comprehensive data definitions set for the investigation of non-traumatic chest pain patients with possible ACS was developed, specifically for use in the ED setting. This standardised data definitions set will facilitate ‘knowledge translation’ by allowing extrapolation of useful findings into the real-life practice of emergency medicine.
Resumo:
BACKGROUND: Western studies have suggested that emotional stress and distress impacted on the morbidity and mortality in people following acute coronary events. Symptoms of anxiety and depression have been associated with re-infarction and death, prolonged recovery and disability and depression may precipitate the client's low self-esteem. This study examined perceived anxiety, depression and self-esteem of Hong Kong Chinese clients diagnosed with acute coronary syndrome (ACS) over a 6-month period following hospital admission. OBJECTIVES: To examine: DESIGN: A prospective, repeated measures design with measures taken on two occasions over a 6-month period; (1) within the 1st week of hospital admission following the onset of ACS and (2) at 6 months follow up. SETTING AND PARTICIPANTS: Convenient sample of 182 voluntary consented clients admitted with ACS to a major public hospital in Hong Kong who could communicate in Chinese, complete questionnaires, cognitive intact, and were haemodynamically stable and free from acute chest pain at the time of interview. METHODS: Baseline data were obtained within 1 week after hospital admission. The follow-up data was collected 6 months after hospital discharge. The Chinese version of the Hospital Anxiety and Depression Scale (HADS), State Self-esteem Scale (SSES), and Rosenberg's Self-Esteem Scale (RSES) were used to assess anxiety and depression, state self-esteem, and trait self-esteem, respectively. RESULTS: Findings suggested gender differences in clients' perception in anxiety, depression and self-esteem. Improvements in clients' perception of these variables were evident over the 6-month period following their acute coronary events. CONCLUSION: The study confirmed the western notion that psychosocial problems are common among coronary clients and this also applies to Hong Kong Chinese diagnosed with ACS. Further studies to explore effective interventions to address these psychosocial issues are recommended.
Resumo:
At the Mater Children’s Hospital, approximately 80% of patients presenting with Adolescent Idiopathic Scoliosis requiring corrective surgery receive a fulcrum bending radiograph. The fulcrum bending radiograph provides a measurement of spine flexibility and a better indication of achievable surgical correction than lateral-bending radiographs (Cheung and Luk, 1997; Hay et al 2008). The magnitude and distribution of the corrective force exerted by the bolster on the patient’s body is unknown. The objective of this pilot study was to measure, for the first time, the forces transmitted to the patient’s ribs through the bolster during the fulcrum bending radiograph.
Resumo:
Most information retrieval (IR) models treat the presence of a term within a document as an indication that the document is somehow "about" that term, they do not take into account when a term might be explicitly negated. Medical data, by its nature, contains a high frequency of negated terms - e.g. "review of systems showed no chest pain or shortness of breath". This papers presents a study of the effects of negation on information retrieval. We present a number of experiments to determine whether negation has a significant negative affect on IR performance and whether language models that take negation into account might improve performance. We use a collection of real medical records as our test corpus. Our findings are that negation has some affect on system performance, but this will likely be confined to domains such as medical data where negation is prevalent.
Resumo:
Purpose: To examine the impact of different endotracheal tube (ETT) suction techniques on regional end-expiratory lung volume (EELV) and tidal volume (VT) in an animal model of surfactant-deficient lung injury. Methods: Six 2-week old piglets were intubated (4.0 mm ETT), muscle-relaxed and ventilated, and lung injury was induced with repeated saline lavage. In each animal, open suction (OS) and two methods of closed suction (CS) were performed in random order using both 5 and 8 French gauge (FG) catheters. The pre-suction volume state of the lung was standardised on the inflation limb of the pressure-volume relationship. Regional EELV and VT expressed as a proportion of the impedance change at vital capacity (%ZVCroi) within the anterior and posterior halves of the chest were measured during and for 60 s after suction using electrical impedance tomography. Results: During suction, 5 FG CS resulted in preservation of EELV in the anterior (nondependent) and posterior(dependent) lung compared to the other permutations, but these only reached significance in the anterior regions (p\0.001 repeated-measures ANOVA). VT within the anterior, but not posterior lung was significantly greater during 5FG CS compared to 8 FG CS; the mean difference was 15.1 [95% CI 5.1, 25.1]%ZVCroi. Neither catheter size nor suction technique influenced post-suction regional EELV or VT compared to pre-suction values (repeated-measures ANOVA). Conclusions: ETT suction causes transient loss of EELV and VT throughout the lung. Catheter size exerts a greater influence than suction method, with CS only protecting against derecruitment when a small catheter is used, especially in the non-dependent lung.