969 resultados para change detection
Resumo:
An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 μm standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1μW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups. © 2007 IEEE.
Resumo:
Electrochemical detection method and related aspects Herein is disclosed an electrochemical test method comprising (i) comparing how a plurality of immittance functions and/or components thereof vary with a change in a parameter of interest for a first system, and then selecting an immittance function or component thereof for use in an electrochemical test; (ii) carryingout an electrochemical test step for a second system to determine at least one value for the immittance function or component thereof selected in step (i), and then, by using a quantitative relationship between the selected immittance function and the parameter of interest, determining a value in the parameter of interest. A computer program and apparatus are also disclosed herein.
Resumo:
PURPOSE: To measure fetal renal volume in normoglycemic and hyperglycemic pregnancies. METHODS: A longitudinal prospective study was conducted and included 92 hyperglycemic and 339 normoglycemic pregnant women attended at the prenatal service of a hospital from Rio de Janeiro State. Ultrasound examinations were performed to estimate gestational age at baseline and the kidney volume was estimated using the prolate ellipsoid volume equation. RESULTS: Fetal kidney volume growth between normoglycemic and hyperglycemic pregnancies are significantly different. The fetal kidney volume growth in pregnancy is positively correlated with gestational age explained by these predictor equations, by group: normal renal volume = exp (6.186+0.09×gestational week); hyperglycemic renal volume = exp (6.978+0.071×gestational week) and an excessive growth pattern for hyperglycemic pregnancies may be established according to gestational age. CONCLUSION: This is important for early detection of abnormalities in pregnancy, particularly in diabetic mothers.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In the instrumental records of daily precipitation, we often encounter one or more periods in which values below some threshold were not registered. Such periods, besides lacking small values, also have a large number of dry days. Their cumulative distribution function is shifted to the right in relation to that for other portions of the record having more reliable observations. Such problems are examined in this work, based mostly on the two-sample Kolmogorov–Smirnov (KS) test, where the portion of the series with more number of dry days is compared with the portion with less number of dry days. Another relatively common problem in daily rainfall data is the prevalence of integers either throughout the period of record or in some part of it, likely resulting from truncation during data compilation prior to archiving or by coarse rounding of daily readings by observers. This problem is identified by simple calculation of the proportion of integers in the series, taking the expected proportion as 10%. The above two procedures were applied to the daily rainfall data sets from the European Climate Assessment (ECA), Southeast Asian Climate Assessment (SACA), and Brazilian Water Resources Agency (BRA). Taking the statistic D of the KS test >0.15 and the corresponding p-value <0.001 as the condition to classify a given series as suspicious, the proportions of the ECA, SACA, and BRA series falling into this category are, respectively, 34.5%, 54.3%, and 62.5%. With relation to coarse rounding problem, the proportions of series exceeding twice the 10% reference level are 3%, 60%, and 43% for the ECA, SACA, and BRA data sets, respectively. A simple way to visualize the two problems addressed here is by plotting the time series of daily rainfall for a limited range, for instance, 0–10 mm day−1.
Resumo:
Background: We aimed to investigate the performance of five different trend analysis criteria for the detection of glaucomatous progression and to determine the most frequently and rapidly progressing locations of the visual field. Design: Retrospective cohort. Participants or Samples: Treated glaucoma patients with =8 Swedish Interactive Thresholding Algorithm (SITA)-standard 24-2 visual field tests. Methods: Progression was determined using trend analysis. Five different criteria were used: (A) =1 significantly progressing point; (B) =2 significantly progressing points; (C) =2 progressing points located in the same hemifield; (D) at least two adjacent progressing points located in the same hemifield; (E) =2 progressing points in the same Garway-Heath map sector. Main Outcome Measures: Number of progressing eyes and false-positive results. Results: We included 587 patients. The number of eyes reaching a progression endpoint using each criterion was: A = 300 (51%); B = 212 (36%); C = 194 (33%); D = 170 (29%); and E = 186 (31%) (P = 0.03). The numbers of eyes with positive slopes were: A = 13 (4.3%); B = 3 (1.4%); C = 3 (1.5%); D = 2 (1.1%); and E = 3 (1.6%) (P = 0.06). The global slopes for progressing eyes were more negative in Groups B, C and D than in Group A (P = 0.004). The visual field locations that progressed more often were those in the nasal field adjacent to the horizontal midline. Conclusions: Pointwise linear regression criteria that take into account the retinal nerve fibre layer anatomy enhances the specificity of trend analysis for the detection glaucomatous visual field progression.
Resumo:
The assessment of the thermal process impact in terms of food safety and quality is of great importance for process evaluation and design. This can be accomplished from the analysis of the residence time and temperature distributions coupled with the kinetics of thermal change, or from the use of a proper time-temperature integrator (TTI) as indicator of safety and quality. The objective of this work was to develop and test enzymic TTIs with rapid detection for the evaluation of continuous HTST pasteurization processes (70-85 degrees C, 10-60 s) of low-viscosity liquid foods, such as milk and juices. Enzymes peroxidase, lactoperoxidase and alkaline phosphatase in phosphate buffer were tested and activity was determined with commercial reflectometric strips. Discontinuous thermal treatments at various time-temperature combinations were performed in order to adjust a first order kinetic model of a two-component system. The measured time-temperature history was considered instead of assuming isothermal conditions. Experiments with slow heating and cooling were used to validate the adjusted model. Only the alkaline phosphatase TTI showed potential to be used for the evaluation of pasteurization processes. The choice was based on the obtained z-values of the thermostable and thermolabile fractions, on the cost and on the validation tests. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Machines with moving parts give rise to vibrations and consequently noise. The setting up and the status of each machine yield to a peculiar vibration signature. Therefore, a change in the vibration signature, due to a change in the machine state, can be used to detect incipient defects before they become critical. This is the goal of condition monitoring, in which the informations obtained from a machine signature are used in order to detect faults at an early stage. There are a large number of signal processing techniques that can be used in order to extract interesting information from a measured vibration signal. This study seeks to detect rotating machine defects using a range of techniques including synchronous time averaging, Hilbert transform-based demodulation, continuous wavelet transform, Wigner-Ville distribution and spectral correlation density function. The detection and the diagnostic capability of these techniques are discussed and compared on the basis of experimental results concerning gear tooth faults, i.e. fatigue crack at the tooth root and tooth spalls of different sizes, as well as assembly faults in diesel engine. Moreover, the sensitivity to fault severity is assessed by the application of these signal processing techniques to gear tooth faults of different sizes.
Resumo:
Sperm cells need hexoses as a substrate for their function, for both the maintenance of membrane homeostasis and the movement of the tail. These cells have a peculiar metabolism that has not yet been fully understood, but it is clear that they obtain energy from hexoses through glycolisis and/or oxidative phosphorylation. Spermatozoa are in contact with different external environments, beginning from the testicular and epididymal fluid, passing to the seminal plasma and finally to the female genital tract fluids; in addition, with the spread of reproductive biotechnologies, sperm cells are diluted and stored in various media, containing different energetic substrates. To utilize these energetic sources, sperm cells, as other eukaryotic cells, have a well-constructed protein system, that is mainly represented by the GLUT family proteins. These transporters have a membrane-spanning α-helix structure and work as an enzymatic pump that permit a fast gradient dependent passage of sugar molecules through the lipidic bilayer of sperm membrane. Many GLUTs have been studied in man, bull and rat spermatozoa; the presence of some GLUTs has been also demonstrated in boar and dog spermatozoa. The aims of the present study were - to determine the presence of GLUTs 1, 2, 3, 4 and 5 in boar, horse, dog and donkey spermatozoa and to describe their localization; - to study eventual changes in GLUTs location after capacitation and acrosome reaction in boar, stallion and dog spermatozoa; - to determine possible changes in GLUTs localization after capacitation induced by insulin and IGF stimulation in boar spermatozoa; - to evaluate changes in GLUTs localization after flow-cytometric sex sorting in boar sperm cells. GLUTs 1, 2, 3 and 5 presence and localization have been demonstrated in boar, stallion, dog and donkey spermatozoa by western blotting and immunofluorescence analysis; a relocation in GLUTs after capacitation has been observed only in dog sperm cells, while no changes have been observed in the other species examined. As for boar, the stimulation of the capacitation with insulin and IGF didn’t cause any change in GLUTs localization, as well as for the flow cytometric sorting procedure. In conclusion, this study confirms the presence of GLUTs 1, 2 ,3 and 5 in boar, dog, stallion and donkey spermatozoa, while GLUT 4 seems to be absent, as a confirmation of other studies. Only in dog sperm cells capacitating conditions induce a change in GLUTs distribution, even if the physiological role of these changes should be deepened.
Resumo:
Opportunistic diseases caused by Human Immunodeficiency Virus (HIV) and Hepatitis B Virus (HBV) is an omnipresent global challenge. In order to manage these epidemics, we need to have low cost and easily deployable platforms at the point-of-care in high congestions regions like airports and public transit systems. In this dissertation we present our findings in using Localized Surface Plasmon Resonance (LSPR)-based detection of pathogens and other clinically relevant applications using microfluidic platforms at the point-of-care setting in resource constrained environment. The work presented here adopts the novel technique of LSPR to multiplex a lab-on-a-chip device capable of quantitatively detecting various types of intact viruses and its various subtypes, based on the principle of a change in wavelength occurring when metal nano-particle surface is modified with a specific surface chemistry allowing the binding of a desired pathogen to a specific antibody. We demonstrate the ability to detect and quantify subtype A, B, C, D, E, G and panel HIV with a specificity of down to 100 copies/mL using both whole blood sample and HIV-patient blood sample discarded from clinics. These results were compared against the gold standard Reverse Transcriptase Polymerase Chain Reaction (RT-qPCR). This microfluidic device has a total evaluation time for the assays of about 70 minutes, where 60 minutes is needed for the capture and 10 minutes for data acquisition and processing. This LOC platform eliminates the need for any sample preparation before processing. This platform is highly multiplexable as the same surface chemistry can be adapted to capture and detect several other pathogens like dengue virus, E. coli, M. Tuberculosis, etc.
Resumo:
To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.
Resumo:
Edges are important cues defining coherent auditory objects. As a model of auditory edges, sound on- and offset are particularly suitable to study their neural underpinnings because they contrast a specific physical input against no physical input. Change from silence to sound, that is onset, has extensively been studied and elicits transient neural responses bilaterally in auditory cortex. However, neural activity associated with sound onset is not only related to edge detection but also to novel afferent inputs. Edges at the change from sound to silence, that is offset, are not confounded by novel physical input and thus allow to examine neural activity associated with sound edges per se. In the first experiment, we used silent acquisition functional magnetic resonance imaging and found that the offset of pulsed sound activates planum temporale, superior temporal sulcus and planum polare of the right hemisphere. In the planum temporale and the superior temporal sulcus, offset response amplitudes were related to the pulse repetition rate of the preceding stimulation. In the second experiment, we found that these offset-responsive regions were also activated by single sound pulses, onset of sound pulse sequences and single sound pulse omissions within sound pulse sequences. However, they were not active during sustained sound presentation. Thus, our data show that circumscribed areas in right temporal cortex are specifically involved in identifying auditory edges. This operation is crucial for translating acoustic signal time series into coherent auditory objects.
Resumo:
The report explores the problem of detecting complex point target models in a MIMO radar system. A complex point target is a mathematical and statistical model for a radar target that is not resolved in space, but exhibits varying complex reflectivity across the different bistatic view angles. The complex reflectivity can be modeled as a complex stochastic process whose index set is the set of all the bistatic view angles, and the parameters of the stochastic process follow from an analysis of a target model comprising a number of ideal point scatterers randomly located within some radius of the targets center of mass. The proposed complex point targets may be applicable to statistical inference in multistatic or MIMO radar system. Six different target models are summarized here – three 2-dimensional (Gaussian, Uniform Square, and Uniform Circle) and three 3-dimensional (Gaussian, Uniform Cube, and Uniform Sphere). They are assumed to have different distributions on the location of the point scatterers within the target. We develop data models for the received signals from such targets in the MIMO radar system with distributed assets and partially correlated signals, and consider the resulting detection problem which reduces to the familiar Gauss-Gauss detection problem. We illustrate that the target parameter and transmit signal have an influence on the detector performance through target extent and the SNR respectively. A series of the receiver operator characteristic (ROC) curves are generated to notice the impact on the detector for varying SNR. Kullback–Leibler (KL) divergence is applied to obtain the approximate mean difference between density functions the scatterers assume inside the target models to show the change in the performance of the detector with target extent of the point scatterers.
Resumo:
In this thesis, we consider Bayesian inference on the detection of variance change-point models with scale mixtures of normal (for short SMN) distributions. This class of distributions is symmetric and thick-tailed and includes as special cases: Gaussian, Student-t, contaminated normal, and slash distributions. The proposed models provide greater flexibility to analyze a lot of practical data, which often show heavy-tail and may not satisfy the normal assumption. As to the Bayesian analysis, we specify some prior distributions for the unknown parameters in the variance change-point models with the SMN distributions. Due to the complexity of the joint posterior distribution, we propose an efficient Gibbs-type with Metropolis- Hastings sampling algorithm for posterior Bayesian inference. Thereafter, following the idea of [1], we consider the problems of the single and multiple change-point detections. The performance of the proposed procedures is illustrated and analyzed by simulation studies. A real application to the closing price data of U.S. stock market has been analyzed for illustrative purposes.