900 resultados para accelerometri magnetometri scanner 3D Kinect
Resumo:
The morphological evolution of the city of Braga has been the subject of several studies focusing on different urban areas in different periods. Using the accumulated knowledge provided by the available archaeological, historical and iconographic data of Braga, from the Roman times to the nineteenth century, we intend to present a working methodology for 3D representation of urban areas and its evolution, using the CityEngine ESRI tool. Different types of graphic and cartographic data will be integrated in an archaeological information system for the characterization of urban buildings. Linking this information system to the rules of characterization of urban spaces through the CityEngine tool, we can create the 3D urban spaces and their changes. The building characterization rules include several parameters of architectural elements that can be dynamically changed according the latest information. This methodology will be applied to the best known areas within of the city allowing the creation of different and dynamic layouts. Considerations about the concepts, challenges and constraints of using the CityEngine tool for recording and representing urban evolution knowledge will be discussed.
Resumo:
Dissertação de mestrado em Biofísica e Bionanossistemas
Resumo:
We perform Monte-Carlo simulations of the three-dimensional Ising model at the critical temperature and zero magnetic field. We simulate the system in a ball with free boundary conditions on the two dimensional spherical boundary. Our results for one and two point functions in this geometry are consistent with the predictions from the conjectured conformal symmetry of the critical Ising model.
Resumo:
Cancer is a major cause of morbidity and mortality worldwide, with a disease burden estimated to increase in the coming decades. Disease heterogeneity and limited information on cancer biology and disease mechanisms are aspects that 2D cell cultures fail to address. We review the current "state-of-the-art" in 3D Tissue Engineering (TE) models developed for and used in cancer research. Scaffold-based TE models and microfluidics, are assessed for their potential to fill the gap between 2D models and clinical application. Recent advances in combining the principles of 3D TE models and microfluidics are discussed, with a special focus on biomaterials and the most promising chip-based 3D models.
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica
Resumo:
Tese de Doutoramento (Programa Doutoral em Engenharia Biomédica)
Resumo:
Co-cultures of two or more cell types and biodegradable biomaterials of natural origin have been successfully combined to recreate tissue microenvironments. Segregated co-cultures are preferred over conventional mixed ones in order to better control the degree of homotypic and heterotypic interactions. Hydrogel-based systems in particular, have gained much attention to mimic tissue-specific microenvironments and they can be microengineered by innovative bottom-up approaches such as microfluidics. In this study, we developed bi-compartmentalized (Janus) hydrogel microcapsules of methacrylated hyaluronic acid (MeHA)/methacrylated-chitosan (MeCht) blended with marine-origin collagen by droplet-based microfluidics co-flow. Human adipose stem cells (hASCs) and microvascular endothelial cells (hMVECs) were co-encapsulated to create platforms of study relevant for vascularized bone tissue engineering. A specially designed Janus-droplet generator chip was used to fabricate the microcapsules (<250â μm units) and Janus-gradient co-cultures of hASCs: hMVECs were generated in various ratios (90:10; 75:25; 50:50; 25:75; 10:90), through an automated microfluidic flow controller (Elveflow microfluidics system). Such monodisperse 3D co-culture systems were optimized regarding cell number and culture media specific for concomitant maintenance of both phenotypes to establish effective cell-cell (homotypic and heterotypic) and cell-materials interactions. Cellular parameters such as viability, matrix deposition, mineralization and hMVECs re-organization in tube-like structures, were enhanced by blending MeHA/MeCht with marine-origin collagen and increasing hASCs: hMVECs co-culture gradient had significant impact on it. Such Janus hybrid hydrogel microcapsules can be used as a platform to investigate biomaterials interactions with distinct combined cell populations.
Resumo:
"Tissue engineering: part A", vol. 21, suppl. 1 (2015)
Resumo:
Relatório de estágio de mestrado em Média Interativos
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)
Resumo:
FUNDAMENTO: O ecocardiograma tridimensional em tempo real (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) são dois novos métodos de análise da fração de ejeção e dos volumes do VE. OBJETIVO: Comparar as medidas da FEVE e dos volumes do VE aferidos pelo ECO 3D e pela CT ultra-rápida. MÉTODOS: Foram estudados pelo ECO 3D e pela CT ultra-rápida de 64 cortes, 39 pacientes consecutivos (27 homens, média etária de 57±12 anos). Foram analisados: FEVE e volumes do VE. Análise estatística: coeficiente de correlação (r: Pearson), teste de Bland & Altman, teste de regressão linear, 95 % IC, p<0,05. RESULTADOS: Medidas do ECO 3D: a FEVE variou de 56,1 a 78,6 (65,5±5,58)%; volume diastólico final variou de 49,6 a 178,2 (87±27,8)ml; volume sistólico final variou de 11,4 a 78 (33,1±13,6)ml. Medidas da CT: a FEVE variou de 53 a 86 (67,8±7,78)%; volume diastólico final variou de 51 a 186 (106,5±30,3) ml; volume sistólico final variou de 7 a 72 (35,5±13,4)ml. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7888, p<0,0001, 95% IC 0,6301 a 0,8843); volume diastólico final (r: 0,7695, p<0,0001, 95% IC 0,5995 a 0,8730); volume sistólico final (r: 0,8119, p<0,0001, 95% IC 0,6673 a 0,8975). CONCLUSÃO: Nesta série, foi observada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D e pela CT ultra-rápida de 64 cortes.
Resumo:
A terapia de ressincronização cardíaca consiste em tratamento promissor para pacientes com insuficiência cardíaca grave, porém cerca de 30% dos pacientes não apresentam melhora clínica com este tratamento. Por outro lado, aproximadamente 10% dos pacientes submetidos a essa terapia podem apresentar hiper resposta, e a ecocardiografia tridimensional pode oferecer uma opção interessante para a seleção e avaliação de tratamento desses pacientes.
Resumo:
FUNDAMENTO: A ecocardiografia consiste em método muito útil para seleção e avaliação de resposta à terapia de ressincronização cardíaca (TRC). O eco 3D já tem seu papel estabelecido na avaliação dos volumes ventriculares e fração de ejeção ventricular esquerda (FEVE) com excelente correlação de resultados quando comparado à RNM. OBJETIVO: Comparar a avaliação dos volumes ventriculares (VDVE, VSVE), FEVE e massa do VE antes e após a TRC pela ecocardiografia bi (Eco 2D) e tridimensional (Eco 3D). MÉTODOS: Foram avaliados 24 pacientes com IC CFIII ou IV (NYHA), ritmo sinusal QRS > 150 ms, em vigência de terapêutica otimizada para IC submetidos a TRC. Foram realizados eletrocardiograma (ECG), avaliação clínica, Eco 2D e 3D antes, três e seis meses após a TRC. A comparação entre as técnicas foi realizada utilizando-se a correlação de Pearson (r). RESULTADOS: No momento basal, a correlação entre os métodos foi de 0,96 para avaliação do VDVE, 0,95 para avaliação do VSVE, 0,87 para FEVE, e 0,72 para massa do VE. Após três meses da TRC, a correlação entre os métodos para análise do VDVE foi de 0,96, 0,95 para VSVE, 0,95 para FEVE, e 0,77 para massa do VE. Após seis meses da TRC, a correlação entre o Eco 2D e 3D para análise do VDVE foi de 0,98, 0,91 para VSVE, 0,96 para FEVE, e 0,85 para massa do VE. CONCLUSÃO: Neste estudo foi observada redução dos VDVE,VSVE, além de melhora da FEVE após a TRC. Houve excelente correlação entre o Eco 2D e o 3D para avaliação dos volumes ventriculares e FEVE, e boa correlação entre os métodos para avaliação da massa ventricular esquerda antes e após a TRC.