942 resultados para Vocal nodules
Resumo:
This paper presents an analysis of women's voices, with a particular focus on how they are often criticized, and a discussion about two linguistic trends popular among them: uptalk and vocal fry
Resumo:
To retrospectively analyze the performance of a commercial computer-aided diagnosis (CAD) software in the detection of pulmonary nodules in original and energy-subtracted (ES) chest radiographs.
Resumo:
Thyroid nodules are a very common clinical finding with an age-related increase in prevalence. The clinical detection of thyroid nodules is outnumbered by the ultrasonographic assessment of thyroid nodules. The clinical challenge is to exclude thyroid cancer and clinical or subclinical hyperthyroidism. Ultrasonography is the first imaging study in all patients with palpable nodules; their size and TSH determine further diagnostic evaluations. Fine-needle aspiration (cytology) is recommended in euthyroid patients of nodules measuring more than 1-1.5 cm in diameter. Nodules more than 4 cm in diameter have to be removed surgically without preceding cytological examination. Without risk factors thyroid nodules are followed by clinical examination and ultrasonography every 6-12 months, in case of symptoms or rapid growth a follow-up assessment should be done earlier.
Resumo:
The purpose of the study was to quantify and compare the effect of CT dose and of size and density of nodules on the detectability of lung nodules and to quantify the influence of CT dose on the size of the nodules.
Resumo:
BackgroundDespite the increasingly higher spatial and contrast resolution of CT, nodular lesions are prone to be missed on chest CT. Tinted lenses increase visual acuity and contrast sensitivity by filtering short wavelength light of solar and artificial origin.PurposeTo test the impact of Gunnar eyewear, image quality (standard versus low dose CT) and nodule location on detectability of lung nodules in CT and to compare their individual influence.Material and MethodsA pre-existing database of CT images of patients with lung nodules >5 mm, scanned with standard does image quality (150 ref mAs/120 kVp) and lower dose/quality (40 ref mAs/120 kVp), was used. Five radiologists read 60 chest CTs twice: once with Gunnar glasses and once without glasses with a 1 month break between. At both read-outs the cases were shown at lower dose or standard dose level to quantify the influence of both variables (eyewear vs. image quality) on nodule sensitivity.ResultsThe sensitivity of CT for lung nodules increased significantly using Gunnar eyewear for two readers and insignificantly for two other readers. Over all, the mean sensitivity of all radiologist raised significantly from 50% to 53%, using the glasses (P value = 0.034). In contrast, sensitivity for lung nodules was not significantly affected by lowering the image quality from 150 to 40 ref mAs. The average sensitivity was 52% at low dose level, that was even 0.7% higher than at standard dose level (P value = 0.40). The strongest impact on sensitivity had the factors readers and nodule location (lung segments).ConclusionSensitivity for lung nodules was significantly enhanced by Gunnar eyewear (+3%), while lower image quality (40 ref mAs) had no impact on nodule sensitivity. Not using the glasses had a bigger impact on sensitivity than lowering the image quality.
Resumo:
The purpose of this retrospective study was to evaluate the impact of energy subtraction (ES) chest radiography on the detection of pulmonary nodules and masses in daily routine. Seventy-seven patients and 25 healthy subjects were examined with a single exposure digital radiography system. Five blinded readers evaluated first the non-subtracted PA and lateral chest radiographs alone and then together with the subtracted PA soft tissue images. The size, location and number of lung nodules or masses were registered with the confidence level. CT was used as standard of reference. For the 200 total lesions, a sensitivity of 33.5-52.5% was found at non-subtracted and a sensitivity of 43.5-58.5% at energy-subtracted radiography, corresponding to a significant improvement in four of five readers (p < 0.05). However, in three of five readers the rate of false positives was higher with ES. With ES, sensitivity, but not the area under the alternative free-response receiver operating characteristics (AFROC) curve, showed a good correlation with reader experience (R = 0.90, p = 0.026). In four of five readers, the diagnostic confidence improved with ES (p = 0.0036). We conclude that single-exposure digital ES chest radiography improves detection of most pulmonary nodules and masses, but identification of nodules <1 cm and false-positive findings remain a problem.
Resumo:
QUESTIONS UNDER STUDY: Vocal cord dysfunction (VCD) is characterised by recurrent attacks of paradoxical adduction of the vocal cords during inspiration, accompanied clinically by dyspnoea attacks with inspiratory stridor lasting between minutes and hours. The aim of the study is to evaluate the self-perception of patients suffering from VCD and how they deal with aggressivity. METHODS: The Giessen Test (GT) and the Picture Frustration Test (PFT) were used on 6 patients with VCD. RESULTS: Five variables show significant differences between the patients with VCD and the values of the normative groups. VCD-patients show an idealized image of themselves, ie relaxed, open, sociable, and capable of devotion. They do not reject accusations against them by others and rarely make self-criticism. In conflicts they behave passively, thus blocking their expression of aggressivity. CONCLUSIONS: In many cases organic disposition and trigger stimuli are thought to be responsible for provoking dyspnoea attacks in VCD. However, the self-perception of patients and their way of dealing with aggressivity strongly suggests that psychosocial factors play a great role in the development of VCD. This requires not only symptom-orientated therapy but also psychological counselling.
Resumo:
We report on a patient who was chronically treated with steroids. She simultaneously developed pulmonary nocardiosis as well as a soft tissue infection and osteomyelitis by mycobacterium abscessus. Both infections are rare, but more frequently occur in immunocompromised hosts. The patient was healed after 12 month of adequate antibiotic treatment.
Resumo:
OBJECTIVE: To evaluate the effects of a single preoperative dose of steroid on thyroidectomy outcomes. BACKGROUND: Nausea, pain, and voice alteration frequently occur after thyroidectomy. Because steroids effectively reduce nausea and inflammation, a preoperative administration of steroids could improve these thyroidectomy outcomes. METHODS: Seventy-two patients (men = 20, women = 52) undergoing thyroidectomy for benign disease were included in this randomized, controlled, 2 armed (group D: 8 mg dexamethasone, n = 37; group C: 0.9% NaCl, n = 35), double-blinded study (clinical trial number NCT00619086). Anesthesia, surgical procedures, antiemetics, and analgesic treatments were standardized. Nausea (0-3), pain (visual analog scale), antiemetic and analgesic requirements, and digital voice recording were documented before and 4, 8, 16, 24, 36, and 48 hours after surgery. Patients were followed-up 30 days after hospital discharge. RESULTS: Baseline characteristics were similar among the 2 treatment groups. Nausea was pronounced in the first 16 hours postoperatively (scores were <0.3 and 0.8-1.0 for group D and C, respectively (P = 0.005)), and was significantly lower in group D compared with group C during the observation period (P = 0.001). Pain diminished within 48 hours after surgery (visual analog scale 20 and 35 in group D and C, respectively (P = 0.009)). Antiemetic and analgesic requirements were also significantly diminished. Changes in voice mean frequency were less prominent in the dexamethasone group compared with the placebo group (P = 0.015). No steroid-related complications occurred. CONCLUSION: A preoperative single dose of steroid significantly reduced nausea, vomiting, and pain, and improved postoperative voice function within the first 48 hours (most pronounced within 16 hours) after thyroid resection; this strategy should be routinely applied in thyroidectomies.
Resumo:
BACKGROUND: Solitary skin nodules composed of pleomorphic T lymphocytes are often the source of diagnostic problems. OBJECTIVE: To characterize the clinicopathological features, prognosis and optimal treatment modalities of patients with solitary lymphoid nodules of small- to medium-sized pleomorphic T lymphocytes. METHODS: Twenty-six patients were analysed for clinical, histopathological, immunophenotypical, molecular and follow-up data. Results: Lesions were located mainly on the head and neck (n = 16; 61.5%) or trunk (n = 8; 30.8%). Histopathology showed non-epidermotropic nodular or diffuse infiltrates of small- to medium-sized pleomorphic T lymphocytes. Monoclonality was found by PCR in 54.2% of cases (n = 13/24). After a mean follow-up of 79.7 months, a local recurrence could be observed only in 1 patient. CONCLUSIONS: Our patients have a specific cutaneous lymphoproliferative disorder characterized by reproducible clinicopathological features. The incongruity between the indolent clinical course and the worrying histopathological features poses difficulties in classifying these cases unambiguously as benign or malignant. We suggest to describe these lesions as 'solitary small- to medium-sized pleomorphic T-cell nodules of undetermined significance'. Irrespective of the name given to these equivocal cutaneous lymphoid proliferations, follow-up data support a non-aggressive therapeutic strategy.
Resumo:
OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.