974 resultados para Venus probes
Resumo:
Information on the solvation in mixtures of water, W, and the ionic liquids, ILs, 1-allyl-3-R-imidazolium chlorides; R = methyl, 1-butyl, and 1-hexyl, has been obtained from the responses of the following solvatochromic probes: 2,6-dibromo-4-[(E)-2-(1-R-pyridinium-4-yl)ethenyl] phenolate, R = methyl, MePMBr2; 1-octyl, OcPMBr(2), and the corresponding quinolinium derivative, MeQMBr(2). A model developed for solvation in binary mixtures of W and molecular solvents has been extended to the present mixtures. Our objective is to assess the relevance to solvation of hydrogen-bonding and the hydrophobic character of the IL and the solvatochromic probe. Plots of the medium empirical polarity, E-T(probe) versus its composition revealed non-ideal behavior, attributed to preferential solvation by the IL and, more efficiently, by the IL-W hydrogen-bonded complex. The deviation from linearity increases as a function of increasing number of carbon atoms in the alkyl group of the IL, and is larger than that observed for solvation by W plus molecular solvents (1-propanol and 2-(1-butoxy)ethanol) that are more hydrophobic than the ILs investigated. This enhanced deviation is attributed to the more organized structure of the ILs proper, which persists in their aqueous solutions. MeQMBr(2) is more susceptible to solvent lipophilicity than OcPMBr(2), although the former probe is less lipophilic. This enhanced susceptibility agrees with the important effect of annelation on the contributions of the quinonoid and zwitterionic limiting structures to the ground and excited states of the probe, hence on its response to both medium composition and lipophilicity of the IL.
Resumo:
The aim of this study was to evaluate the microbial growth on single-use vitrectomy probes reprocessed in healthcare practice. We investigated nine vitrectomy probes that had been reused and reprocessed using different methods. The samples were sectioned, individually, in portions of 3.5 cm, totaling 979 sampling units (extensions, connectors and vitrectomy cutters), which were inoculated in culture medium and incubated at 37 C for 14 days. The results showed microbial growth on 57 (5.8%) sample units, 25 of which had been sterilized using ethylene oxide, 16 by hydrogen peroxide plasma, and 16 by low-temperature steam and formaldehyde. Seventeen microbial species were identified. The most prevalent were: Micrococcus spp., coagulase-negative Staphylococcus, Pseudomonas spp., and Bacillus subtilis. The reuse of single-use vitrectomy probes was shown to be unsafe, therefore this practice is not recommended.
Resumo:
The objective of this study was to evaluate the quality of bovine frozen-thawed sperm cells after Percoll gradient centrifugation. Frozen semen doses were obtained from six bulls of different breeds, including three taurine and three Zebu animals. Four ejaculates per bull were evaluated before and after discontinuous Percoll gradient centrifugation. Sperm motility was assessed by computer-assisted semen analysis and the integrity of the plasma and acrosomal membranes, as well as mitochondrial function, were evaluated using a combination of fluorescent probes propidium iodide, fluorescein isothiocyanate-conjugated Pisum sativum agglutinin and 5,5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimidazolcarbocyanine iodide. The procedure of Percoll gradient centrifugation increased the percentage of total and progressive sperm motility, beat frequency, rectilinear motility, linearity and rapidly moving cells. In addition, the percentage of cells with intact plasma membrane and mitochondrial membrane potential was increased in post-centrifugation samples. However, the percentage of sperm cells with intact acrosomal membrane was markedly reduced. The method used selected the motile cells with intact plasma membrane and higher mitochondrial functionality in frozen-thawed bull semen, but processing, centrifugation and/or the Percoll medium caused damage to the acrosomal membrane.
Resumo:
Studi recenti sull’utilizzo di sonde organometalliche per bioconiugazione sfruttano la possibilità di interazione di queste con una proteina, l’avidina, per la sua capacità di coordinarsi selettivamente ad una particolare molecola organica, la biotina. In questa tesi viene descritta la sintesi di due leganti bi-funzionali contenenti sia un’unità capace di fungere da legante per un opportuno metallo, che un’unità di biotina in grado di legarsi all’avidina. La differenza fra i due leganti risiede nello spaziatore che collega le due unità funzionali della molecola. Una volta ottenuti i leganti progettati, sono stati sintetizzati i corrispondenti complessi di Ir (III) e Re (I). Le proprietà fotofisiche sono state misurate sia in solvente organico che in soluzione acquosa e quindi sono state effettuate titolazioni dell’avidina con soluzioni acquose a titolo noto dei complessi sintetizzati, con il fine di comprendere come le proprietà luminescenti dei complessi vengano influenzate dalla bio-coniugazione tra biotina ed avidina.
Resumo:
A Micro-opto-mechanical systems (MOMS) based technology for the fabrication of ultrasonic probes on optical fiber is presented. Thanks to the high miniaturization level reached, the realization of an ultrasonic system constituted by ultrasonic generating and detecting elements, suitable for minimally invasive applications or Non Destructive Evaluation (NDE) of materials at high resolution, is demonstrated. The ultrasonic generation is realized by irradiating a highly absorbing carbon film patterned on silicon micromachined structures with a nanosecond pulsed laser source, generating a mechanical shock wave due to the thermal expansion of the film induced by optical energy conversion into heat. The short duration of the pulsed laser, together with an appropriate emitter design, assure high frequency and wide band ultrasonic generation. The acoustic detection is also realized on a MOMS device using an interferometric receiver, fabricated with a Fabry-Perot optical cavity realized by means of a patterned SU-8 and two Al metallization levels. In order to detect the ultrasonic waves, the cavity is interrogated by a laser beam measuring the reflected power with a photodiode. Various issues related to the design and fabrication of these acoustic probes are investigated in this thesis. First, theoretical models are developed to characterize the opto-acoustic behavior of the devices and estimate their expected acoustic performances. Tests structures are realized to derive the relevant physical parameters of the materials constituting the MOMS devices and determine the conditions theoretically assuring the best acoustic emission and detection performances. Moreover, by exploiting the models and the theoretical results, prototypes of acoustic probes are designed and their fabrication process developed by means of an extended experimental activity.
Resumo:
Sequenz spezifische biomolekulare Analyseverfahren erweisen sich gerade im Hinblick auf das Humane Genom Projekt als äußerst nützlich in der Detektion von einzelnen Nukleotid Polymorphismen (SNPs) und zur Identifizierung von Genen. Auf Grund der hohen Anzahl von Basenpaaren, die zu analysieren sind, werden sensitive und effiziente Rastermethoden benötigt, welche dazu fähig sind, DNA-Proben in einer geeigneten Art und Weise zu bearbeiten. Die meisten Detektionsarten berücksichtigen die Interaktion einer verankerten Probe und des korrespondierenden Targets mit den Oberflächen. Die Analyse des kinetischen Verhaltens der Oligonukleotide auf der Sensoroberfläche ist infolgedessen von höchster Wichtigkeit für die Verbesserung bereits bekannter Detektions - Schemata. In letzter Zeit wurde die Oberflächen Plasmonen feld-verstärkte Fluoreszenz Spektroskopie (SPFS) entwickelt. Sie stellt eine kinetische Analyse - und Detektions - Methode dar, die mit doppelter Aufzeichnung, d.h. der Änderung der Reflektivität und des Fluoreszenzsignals, für das Interphasen Phänomen operiert. Durch die Verwendung von SPFS können Kinetikmessungen für die Hybridisierung zwischen Peptid Nukleinsäure (PNA), welche eine synthetisierte Nukleinsäure DNA imitiert und eine stabilere Doppelhelix formt, und DNA auf der Sensoroberfläche ausgeführt werden. Mittels einzel-, umfassend-, und titrations- Experimenten sowohl mit einer komplementär zusammenpassenden Sequenz als auch einer mismatch Sequenz können basierend auf dem Langmuir Modell die Geschwindigkeitskonstanten für die Bindungsreaktion des oligomer DNA Targets bzw. des PCR Targets zur PNA ermittelt werden. Darüber hinaus wurden die Einflüsse der Ionenstärke und der Temperatur für die PNA/DNA Hybridisierung in einer kinetischen Analyse aufgezeigt.
Resumo:
The goal of this thesis is to analyze the possibility of using early-type galaxies to place evolutionary and cosmological constraints, by both disentangling what is the main driver of ETGs evolution between mass and environment, and developing a technique to constrain H(z) and the cosmological parameters studying the ETGs age-redshift relation. The (U-V) rest-frame color distribution is studied as a function of mass and environment for two sample of ETGs up to z=1, extracted from the zCOSMOS survey with a new selection criterion. The color distributions and the slopes of the color-mass and color-environment relations are studied, finding a strong dependence on mass and a minor dependence on environment. The spectral analysis performed on the D4000 and Hδ features gives results validating the previous analysis. The main driver of galaxy evolution is found to be the galaxy mass, the environment playing a subdominant but non negligible role. The age distribution of ETGs is also analyzed as a function of mass, providing strong evidences supporting a downsizing scenario. The possibility of setting cosmological constraints studying the age-redshift relation is studied, discussing the relative degeneracies and model dependencies. A new approach is developed, aiming to minimize the impact of systematics on the “cosmic chronometer” method. Analyzing theoretical models, it is demonstrated that the D4000 is a feature correlated almost linearly with age at fixed metallicity, depending only minorly on the models assumed or on the SFH chosen. The analysis of a SDSS sample of ETGs shows that it is possible to use the differential D4000 evolution of the galaxies to set constraints to cosmological parameters in an almost model-independent way. Values of the Hubble constant and of the dark energy EoS parameter are found, which are not only fully compatible, but also with a comparable error budget with the latest results.
Resumo:
The present work consists of the investigation of the navigation of Pioneer 10 and 11 probes becoming known as the “Pioneer Anomaly”: the trajectories followed by the spacecrafts did not match the ones retrieved with standard navigation software. Mismatching appeared as a linear drift in the Doppler data received by the spacecrafts, which has been ascribed to a constant sunward acceleration of about 8.5×10-10 m/s2. The study presented hereafter tries to find a convincing explanation to this discrepancy. The research is based on the analysis of Doppler tracking data through the ODP (Orbit Determination Program), developed by NASA/JPL. The method can be summarized as: seek for any kind of physics affecting the dynamics of the spacecraft or the propagation of radiometric data, which may have not been properly taken into account previously, and check whether or not these might rule out the anomaly. A major effort has been put to build a thermal model of the spacecrafts for predicting the force due to anisotropic thermal radiation, since this is a model not natively included in the ODP. Tracking data encompassing more than twenty years of Pioneer 10 interplanetary cruise, plus twelve years of Pioneer 11 have been analyzed in light of the results of the thermal model. Different strategies of orbit determination have been implemented, including single arc, multi arc and stochastic filters, and their performance compared. Orbital solutions have been obtained without the needing of any acceleration other than the thermal recoil one indicating it as the responsible for the observed linear drift in the Doppler residuals. As a further support to this we checked that inclusion of additional constant acceleration as does not improve the quality of orbital solutions. All the tests performed lead to the conclusion that no anomalous acceleration is acting on Pioneers spacecrafts.
Resumo:
VIRTIS, a bordo di Venus Express, è uno spettrometro in grado di operare da 0.25 a 5 µm. Nel periodo 2006-2011 ha ricavato un'enorme mole di dati ma a tutt'oggi le osservazioni al lembo sono poco utilizzate per lo studio delle nubi e delle hazes, specialmente di notte. Gli spettri al lembo a quote mesosferiche sono dominati dalla radianza proveniente dalle nubi e scatterata in direzione dello strumento dalle hazes. L'interpretazione degli spettri al lembo non può quindi prescindere dalla caratterizzazione dell'intera colonna atmosferica. L'obiettivo della tesi è di effettuare un’analisi statistica sulle osservazioni al nadir e proporre una metodologia per ricavare una caratterizzazione delle hazes combinando osservazioni al nadir e al lembo. La caratterizzazione delle nubi è avvenuta su un campione di oltre 3700 osservazioni al nadir. È stato creato un ampio dataset di spettri sintetici modificando, in un modello iniziale, vari parametri di nube quali composizione chimica, numero e dimensione delle particelle. Un processo di fit è stato applicato alle osservazioni per stabilire quale modello potesse descrivere gli spettri osservati. Si è poi effettuata una analisi statistica sui risultati del campione. Si è ricavata una concentrazione di acido solforico molto elevata nelle nubi basse, pari al 96% in massa, che si discosta dal valore generalmente utilizzato del 75%. Si sono poi integrati i risultati al nadir con uno studio mirato su poche osservazioni al lembo, selezionate in modo da intercettare nel punto di tangenza la colonna atmosferica osservata al nadir, per ricavare informazioni sulle hazes. I risultati di un modello Monte Carlo indicano che il numero e le dimensioni delle particelle previste dal modello base devono essere ridotte in maniera significativa. In particolare si osserva un abbassamento della quota massima delle hazes rispetto ad osservazioni diurne.
Resumo:
In this experimental work we report the design, the synthesis and characterization of a new class of Re(I) complexes of the general formula fac-[Re(CO)3(N^N)(2-QTZ)], where N^N = 2,2’ bipyridine or 1,10 phenantroline, whereas 2-QTZ is the anion 2-quinolyl-tetrazolate. The complexes and, in particular, the tetrazolate ligand 2-QTZ were designed in order to investigate their specific interaction with biologically and toxicologically relevant metal ions, as Zn(II), Cd(II) e Cu(II). The addition of such ions led to substantial variations of the photophysical properties of these complexes, suggesting their application as luminescent sensors. The photophysical performance of the complexes proved to remain unchanged inside cellular substrates, as Yarrowia Lipolytica cultures. Within these yeasts, the complexes show unchanged ability to perform luminescent sensing towards Zn(II) and Cd(II) ions.
Resumo:
Owing to its optimal nuclear properties, ready availability, low cost and favourable dosimetry, (99m)Tc continues to be the ideal radioisotope for medical-imaging applications. Bifunctional chelators based on a tetraamine framework exhibit facile complexation with Tc(V)O(2) to form monocationic species with high in vivo stability and significant hydrophilicity, which leads to favourable pharmacokinetics. The synthesis of a series of 1,4,8,11-tetraazaundecane derivatives (01-06) containing different functional groups at the 6-position for the conjugation of biomolecules and subsequent labelling with (99m)Tc is described herein. The chelator 01 was used as a starting material for the facile synthesis of chelators functionalised with OH (02), N(3) (04) and O-succinyl ester (05) groups. A straightforward and easy synthesis of carboxyl-functionalised tetraamine-based chelator 06 was achieved by using inexpensive and commercially available starting materials. Conjugation of 06 to a potent bombesin-antagonist peptide and subsequent labelling with (99m)Tc afforded the radiotracer (99m)Tc-N4-BB-ANT, with radiolabelling yields of >97% at a specific activity of 37 GBq micromol(-1). An IC(50) value of (3.7+/-1.3) nM was obtained, which confirmed the high affinity of the conjugate to the gastrin-releasing-peptide receptor (GRPr). Immunofluorescence and calcium mobilisation assays confirmed the strong antagonist properties of the conjugate. In vivo pharmacokinetic studies of (99m)Tc-N4-BB-ANT showed high and specific uptake in PC3 xenografts and in other GRPr-positive organs. The tumour uptake was (22.5+/-2.6)% injected activity per gram (% IA g(-1)) at 1 h post injection (p.i.). and increased to (29.9+/-4.0)% IA g(-1) at 4 h p.i. The SPECT/computed tomography (CT) images showed high tumour uptake, clear background and negligible radioactivity in the abdomen. The promising preclinical results of (99m)Tc-N4-BB-ANT warrant its potential candidature for clinical translation.
Resumo:
The vibrational excitation of CO2 by a fast-moving O atom followed by infrared emission from the vibrationally excited CO2 has been shown to be an important cooling mechanism in the upper atmospheresof Venus, Earth and Mars. We are trying to determine more precisely the efficiency (rate coefficient) of the CO2-O vibrational energy transfer. For experimental ease the reverse reaction is used, i.e. collision of a vibrationally excited CO2 with atomic O, where we are able to convert to the atmospherically relevant reaction via a known equilibrium constant. The goal of this experiment was to measure the magnitudes of rate coefficients for vibrational energy states above the first excited state, a bending mode in CO2. An isotope of CO2, 13CO2, was used for experimental ease. The rate coefficients for given vibrational energy transfers in 13CO2 are not significantly different from 12CO2 at this level of precision. A slow-flowing gas mixture was flowed through a reaction cell: 13CO2 (vibrational specie of interest), O3(atomic O source), and Ar (bath gas). Transient diode laser absorption spectroscopy was used to monitor thechanging absorption of certain vibrational modes of 13CO2 after a UV pulse from a Nd:YAG laser was fired. Ozone absorbed the UV pulse in a process which vibrationally excited 13CO2 and liberated atomic O.Transient absorption signals were obtained by tuning the diode laser frequency to an appropriate ν3 transition and monitoring the population as a function of time following the Nd:YAG pulse. Transient absorption curves were obtained for various O atom concentrations to determine the rate coefficient of interest. Therotational states of the transitions used for detection were difficult to identify, though their short reequilibration timescale made the identification irrelevant for vibrational energy transfer measurements. The rate coefficient for quenching of the (1000) state was found to be (4 ± 8) x 10-12 cm3 s-1 which is the same order of magnitude as the lowest-energy bend-excited mode: (1.8 ± 0.3) x 10-12 cm3 s-1. More data is necessary before it can be certain that the numerical difference between the two is real.