889 resultados para Validation of analytical methodology
Resumo:
Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.
Resumo:
Behavioral problems in preschool children are one of the most frequent motives for seeking psychological care by parents and caregivers. Instruments are considered necessary, created from a Social Skills Training theoretical-practical perspective, which may systematically assist the identification of social skills and behavioral deficits. helping professionals in the prevention and/or reduction of behavioral problems. The purpose of this study was to test the psychometric validity and reliability of an instrument for evaluation of Socially Skilled Responses. from a teacher`s perspective (QRSH-PR). For this purpose, 260 preschool children were evaluated. differentiated in subgroups without and without behavioral difficulties, based on the Child Behavior Scale (Escala de Comportamento Infantil/ECI-Professor). Studies were conducted for construct. discrimination. concurrent and predictive validity. The Cronbach Alpha was calculated to evaluate internal consistency. The obtained results pointed to positive indicators in reference to construct, discrimination, and predictive validity, and even for good internal consistency. indicating that the items consistently measure the construct of social skills, and differentiated children with and without behavioral problems. The questionnaire is considered to be gauged for evaluation of socially skilled responses from preschool children. and applicable in educational and clinical environments.
Resumo:
Background: We aimed to validate three widely used scales in stroke research in a multiethnic Brazilian population. Methods: The National Institutes of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS) and Barthel Index (BI) were translated, culturally adapted and applied by two independent investigators. The mRS was applied with or without a previously validated structured interview. Interobserver agreement (kappa statistics) and intraclass correlation coefficients were calculated. Results: 84 patients underwent mRS (56 with and 28 without a structured interview), 57 BI and 62 NIHSS scoring. Intraclass correlation coefficient was 0.902 for NIHSS and 0.967 for BI. For BI, interobserver agreement was good (kappa = 0.70). For mRS, the structured interview improved interobserver agreement (kappa = 0.34 without a structured interview; 0.75 with a structured interview). Conclusion: The NIHSS, BI and mRS show good validity when translated and culturally adapted. Using a structured interview for the mRS improves interobserver concordance rates. Copyright (C) 2008 S. Karger AG, Basel
Resumo:
Objective: This study aimed to assess the relative validity of a food frequency questionnaire.(FFQ), previously validated to measure usual intakes in adults, for measuring dietary intakes in children 5 to 10 y of age. Methods: Dietary intakes were measured using an FFQ and a 3-d dietary record. Healthy children, 5 to 10 y old (n = 151), were recruited from public schools and asked to answer the questions in the FFQ and to provide non-consecutive 3-d dietary records based on reported estimated portion sizes. Paired sample t tests and Pearson`s correlation coefficients were conducted to determine whether the two instruments reported similar values for energy and nutrients. The agreement of quartile categorization between the two instruments was also examined. Results: Estimated energy and nutrient intakes derived from the FFQ were significantly higher than those derived from 3-d dietary records. As expected, Pearson`s correlations increased after adjusting for residual measurement error, presumably due to exclusion of the high within-person variability in intake of these nutrients. Moderate to high (r > 0.50) correlation coefficients were verified for some nutrients such as calcium, folate, vitamin 132, vitamin A, and vitamin C. Conclusion: This FFQ, originally developed for use in adults, appears to overestimate usual energy and nutrient intakes in children 5 to 10 y of age. Further work is necessary to conduct a calibration study to establish adequate portion sizes before instrument adoption in this population. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
Quality of life (QOL) has been extensively studied in clinical trials and in research on chronic degenerative diseases and dementia. The aim of this study was to assess the reliability and construct validity of the Brazilian version of the QOL scale in Alzheimer`s disease (AD; QOL-AD). The QOL-AD was administered to 60 patients with mild or moderate AD and to their caregivers. The construct validation was accomplished through correlations amongst total scores of patients` and caregivers` reports on patients` quality of life (PQOL and C-PQOL, respectively), and data related to cognitive impairment, depressive symptoms, functional performance, behavioral disturbances and a generic instrument of quality of life (WHOQOL-brief), as well as correlation of total score of caregivers` reports on their own quality of life (CQOL) with the measurements cited above, QOL-AD patient reports, and depressive symptoms. The reliability was high for PQOL, C-PQOL, and CQOL versions (Cronbach`s alpha = 0.80, 0.83, and 0.86, respectively). We observed significant correlations in the construct validity of all three versions regarding the variables associated with the disease and also with WHOQOL-brief. The scale took, on average, six min for each version. The results indicate reliability and construct validity of the Brazilian version of the QOL-AD in the studied sample.
Resumo:
In recent years, there has been increasing fish consumption in Brazil, largely due to the popularity of Japanese cuisine. No study, however, has previously assessed the presence of inorganic contaminants in species used in the preparation of Japanese food. In this paper, we determined total arsenic, cadmium, chromium, total mercury, and lead contents in 82 fish samples of Tuna (Thunnus thynnus), Porgy (Pagrus pagrus), Snook (Centropomus sp.), and Salmon (Salmo salar) species marketed in Sao Paulo (Brazil). Samples were mineralized in HNO(3)/H(2)O(2) for As, Cd, Cr and Pb, and in HNO(3)/H(2)SO(4)/V(2)O(5) for Hg. Inorganic contaminants were determined after the validation of the methodology using Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES); and for Hg, an ICP-coupled hydride generator was used. Concentration ranges for elements analyzed in mg kg(-1) (wet base) were as follows: Total As (0.11-10.82); Cd (0.005-0.047); Cr (0.008-0.259); Pb (0.026-0.481); and total Hg (0.0077-0.9681). As and Cr levels exceeded the maximum limits allowed by the Brazilian law (1 and 0.1 mg kg(-1)) in 51.2 and 7.3% of the total samples studied, respectively. The most contaminated species were porgy (As = 95% and Cr = 10%) and tuna (As 91% and Cr = 10%). An estimation of As, Cd, Pb, and Hg weekly intake was calculated considering a 60 kg adult person and a 350 g consumption of fish per week, with As and Hg elements presenting the highest contribution on diets reaching 222% of provisional tolerable weekly intake (PTWI) for As in porgy and 41% of PTWI for Hg in tuna. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
A standardised nested-PCR method that amplifies a region of the glycoprotein E gene of avian infectious laryngotracheitis virus (ILTV) has been developed for the diagnosis of infection by Gallid herpesvirus 1. The two sets of primers employed produced the expected ampIification products of 524bp(externa I primers) and 219bp (internal primers) in the presence of ILTV DNA, whereas no Such amplicons were obtained with other avian respiratory pathogens or with DNA extracted from the cells of uninfected chickens. The identity of the 219bp amplified product was con firmed by DNA sequencing. The standardised nested-PCR method detected ILTV DNA from trachea, lung, conjunctiva and trigeminal ganglia samples from flocks of birds with and without clinical signs. and showed hi.-h sensitivity (95.4%) and specificity (93.1%) when compared with the reference test involving virus isolation in specific-pathogen-free chicken embryos. The standardised nested-PCR method described may be used to detect clinical and latent ILTV infections, and will be of significant value for both diagnostic and epidemiological Studies. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
The aim of the present study was to determine the relationship among body weight (BW), body condition score (BCS) and rump fat thickness (RFAT) measured by ultrasonography, and validate the relationship between BCS and RFAT over the time. Two hundred sixty and six Nelore cows had their BW, BCS and RFAT evaluated at five different moments during the production cycle: M1) weaning: M2) parturition, M3) 42 days post-partum; M4) 82 days postpartum and M5) 112 days post-partum. A BCS value was attributed for each cow following a I to 5 points scale. Ultrasonographic images for RFAT measurement were obtained using a 3.5 MHz linear transducer. Images were immediately analyzed as soon as they were formed and frozen. Body condition scores and ultrasound measurements were collected on the same day by a single trained technician. The relationship between BCS and RFAT values was investigated by regression models. The analysis of similarity among the five obtained models was performed using the proc MIXED from SAS and the correlations among variables were analyzed with proc CORR from SAS. The BCS was able to predict RFAT in Nelore cows in all different moments evaluated. Also, it was shown that BCS presented high correlation (r=0.82 to 0.93) and relationship (R(2) = 0.73 to 0.92) with RFAT. However, both BCS and RFAT showed low correlation (r=0.37 to 0.50) and relationship (R(2) = 0.13 to 0.25) with BW. The BCS classification by visual method using a 1 to 5 point scale, was able to predict the RFAT in Nelore cows over the time. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Simple, rapid and stable sperm evaluation methods which have been optimized for common marmoset (Callithrix jacchus) are critical for studies involving collection and evaluation of sperm in the field. This is particularly important for new species groups such as Callitrichidae where the sperm have been little studied. Of this family, C jacchus is the best known, and has been chosen as a model species for other members of the genus Callithrix. The fundamental evaluation parameters for sperm of any species are viability and acrosomal status. Semen samples were collected by penile vibratory stimulation. To evaluate sperm plasma membrane integrity, Eosin-Nigrosin was tested here for the common marmoset sperm to be used under field conditions. Further, a non-fluorescent stain for acrosome, the ""Simple"" stain, developed for domestic and wild cats, was tested on common marmoset sperm. This was compared with a fluorescent staining, Fluorescein isothiocyanate-Pisum sativum agglutinin (FITC-PSA), routinely used and validated for common marmoset at the German Primate Centre to evaluate acrosomal integrity. Results obtained with the ""Simple"" stain showed a marked differentiation between sperm with intact and non-intact acrosome both with and without ionophore treatment and closely correlated with results obtained with FITC-PSA. Temperature had no effect on the results with the ""Simple"" stain and the complete processing is simple enough to be carried out under field conditions. These findings indicated that the ""Simple"" stain and Eosin-Nigrosin provide rapid and accurate results for C. jacchus sperm and that those methods can be reliably used as field tools for sperm evaluation for this species. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.
Resumo:
Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.
Resumo:
Background: The Edinburgh Postnatal Depression Scale (EPDS) has been validated and used extensively in screening for depression in new mothers, both in English speaking and non-English speaking communities. While some studies have reported the use of the EPDS with Fathers, none have validated it for this group, and thus the appropriate cut-off score for screening for depression or anxiety caseness for this population is not known. Method: Couples were recruited antenatally and interviewed at six weeks postpartum. EPDS scores and distress caseness (depression or anxiety disorders) for 208 fathers and 230 mothers were determined using the Diagnostic Interview Schedule. Results: Analyses of the EPDS for fathers using distress caseness (depression or anxiety disorders) as the criterion shows that a cut-off of 5/6 has optimum receiver operating characteristics. Furthermore acceptable reliability (split-half and internal consistency) and validity (concurrent) coefficients were obtained. For mothers the optimum cut-off screening value to detect distress caseness was 7/8. Item analysis revealed that fathers endorsed seven of the ten items at lower rates to mothers, with the most significant being that referring to crying. Conclusions: The EPDS is a reliable and valid measure of mood in fathers. Screening for depression or anxiety disorders in fathers requires a two point lower cut-off than screening for depression or anxiety in mothers, and we recommend this cut-off to he 5/6. (C) 2001 Elsevier Science B.V. All rights reserved.