977 resultados para VENOUS DOPPLER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Early detection is a major goal in the management of malignant melanoma. Besides clinical assessment many noninvasive technologies such as dermoscopy, digital dermoscopy and in vivo laser scanner microscopy are used as additional methods. Herein we tested a system to assess lesional perfusion as a tool for early melanoma detection.¦METHODS: Laser Doppler flow (FluxExplorer) and mole analyser (MA) score (FotoFinder) were applied to histologically verified melanocytic nevi (33) and malignant melanomas (12).¦RESULTS: Mean perfusion and MA scores were significantly increased in melanoma compared to nevi. However, applying an empirically determined threshold of 16% perfusion increase only 42% of the melanomas fulfilled the criterion of malignancy, whereas with the mole analyzer score 82% of the melanomas fulfilled the criterion of malignancy.¦CONCLUSION: Laser Doppler imaging is a highly sensitive technology to assess skin and skin tumor perfusion in vivo. Although mean perfusion is higher in melanomas compared to nevi the high numbers of false negative results hamper the use of this technology for early melanoma detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Nasal continuous positive airways pressure (n-CPAP) is an effective treatment in premature infants with respiratory distress. The cardio-pulmonary interactions secondary to n-CPAP are well studied in adults, but less well described in premature infants. We postulated that there could be important interactions with regard to the patent ductus arteriosus (PDA). Methods: Prospective study, approved by the local ethic committee. Premature infants less than 32 weeks gestation, _7 days-old, needing n-CPAP for respiratory distress, but without the need of additional oxygen were included in the study. Every patient had a first echocardiography with n-CPAP and then n-CPAP was retrieved. 3 hours later the echocardiography was repeated by the same investigator and then the patient replaced on n-CPAP. Results: 14 premature newborn were included, mean gestational age of 28 _ 2 weeks, mean weight 1.1 _ 0.3 Kg and height 39 _ 3 cm. Echocardiographic measurements are depicted in Table 1. Significant finding were observed between measurement on n- CPAP or without n-CPAP: on end diastolic left ventricular diameter (12.8 _ 1.6 mm vs. 13.5 _ 2 mm), on end systolic left ventricular diameter (8.4 _ 1.3 mm vs. 9.1 _ 1.5 mm), left atrium diameter (8.9 _ 2.2 mm vs. 10.4 _ 2.5 mm), maximal velocity on tricuspid valve (46 _ 10 cm/s vs. 51 _ 9 cm/s), calculated Qp (3.7 _ 0.8 L/min/m2 vs. 4.3 _ 0.8 L/min/m2). Only three patients have demonstrated a PDA during the study. Conclusion: Positive end expiratory pressure (Peep) has hemodynamic effects which are: reduction of systemic and pulmonary venous return as shown by the changes on tricuspid valve inflow,on the calculated Qp and finally on the diameter of the left atrium and left ventricle.We found in premature infants the same hemodynamic effects than those described in adults but with lower Peep values. This could be due to the particular elasticity and weakness of the thoracic wall of premature infants. Interestingly the flow through a PDA seems also to be diminished with Peep, but the number of patients is insufficient to conclude. Further investigation will be needed to better understand these interactions. Table 1. Echocardiographic measurement (mean (SD)). With n-CPAP Without n-CPAP p value RV ED diameter (mm) 6.3 (1.7) 6.04 (1.1) NS LV ED diameter (mm) 12.8 (1.6) 13.5 (2.0) _0.05 LV ES diameter (mm) 8.4 (1.3) 9.1 (1.5) _0.05 SF (%) 34 (5) 33 (6) NS Ao valve diameter (mm) 7.4 (1.3) 7.4 (1.2) NS LA diameter (mm) 8.9 (2.2) 10.4 (2.5) _0.05 Vmax Ao (cm/s) 70 (16) 71 (18) NS Vmax PV (cm/s) 69 (15) 72 (16) NS Vmax TV (cm/s) 46 (10) 51 (9) _0.05 Vmax MV (cm/s) 53 (17) 54 (18) NS Qp (L/min/m2) 3.7 (0.8) 4.3 (0.8) _0.05 Qs (L/min/m2) 4.0 (0.8) 4.0 (0.7) NS Qp/Qs 0.92 (0.14) 1.09 (0.23) _0.05 RV: right ventricle, LV: left ventricle, ED: end diastolic, ES: end systolic, SF: shortening fraction,Ao: aortic valve, LA: left atrium,Vmax: maximum Doppler Velocity, Qp: pulmonary output, Qs: systemic output, NS: non significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Chronic venous insufficiency (CVI) represents a major global health problem with increasing prevalence and morbidity. CVI is due to an incompetence of the venous valves, which causes venous reflux and distal venous hypertension. Several studies have focused on the replacement of diseased venous valves using xeno- and allogenic transplants, so far with moderate success due to immunologic and thromboembolic complications. Autologous cell-derived tissue-engineered venous valves (TEVVs) based on fully biodegradable scaffolds could overcome these limitations by providing non-immunogenic, non-thrombogenic constructs with remodeling and growth potential. Methods: Tri- and bicuspid venous valves (n=27) based on polyglycolic acid-poly-4-hydroxybutyrate composite scaffolds, integrated into self-expandable nitinol stents, were engineered from autologous ovine bone-marrow-derived mesenchymal stem cells (BM-MSCs) and endothelialized. After in vitro conditioning in a (flow) pulse duplicator system, the TEVVs were crimped (n=18) and experimentally delivered (n=7). The effects of crimping on the tissue-engineered constructs were investigated using histology, immunohistochemistry, scanning electron microscopy, grating interferometry (GI), and planar fluorescence reflectance imaging. Results: The generated TEVVs showed layered tissue formation with increasing collagen and glycosaminoglycan levels dependent on the duration of in vitro conditioning. After crimping no effects were found on the MSC level in scanning electron microscopy analysis, GI, histology, and extracellular matrix analysis. However, substantial endothelial cell loss was detected after the crimping procedure, which could be reduced by increasing the static conditioning phase. Conclusions: Autologous living small-diameter TEVVs can be successfully fabricated from ovine BM-MSCs using a (flow) pulse duplicator conditioning approach. These constructs hold the potential to overcome the limitations of currently used non-autologous replacement materials and may open new therapeutic concepts for the treatment of CVI in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Sclerotherapy is the targeted chemical ablation of varicose veins by intravenous injection of a liquid or foamed sclerosing drug. The treated veins may be intradermal, subcutaneous, and/or transfascial as well as superficial and deep in venous malformations. The aim of this guideline is to give evidence-based recommendations for liquid and foam sclerotherapy. METHODS: This guideline was drafted on behalf of 23 European Phlebological Societies during a Guideline Conference on 7-10 May 2012 in Mainz. The conference was organized by the German Society of Phlebology. These guidelines review the present state of knowledge as reflected in published medical literature. The regulatory situation of sclerosant drugs differs from country to country but this has not been considered in this document. The recommendations of this guideline are graded according to the American College of Chest Physicians Task Force recommendations on Grading Strength of Recommendations and Quality of Evidence in Clinical Guidelines. RESULTS: This guideline focuses on the two sclerosing drugs which are licensed in the majority of the European countries, polidocanol and sodium tetradecyl sulphate. Other sclerosants are not discussed in detail. The guideline gives recommendations concerning indications, contraindications, side-effects, concentrations, volumes, technique and efficacy of liquid and foam sclerotherapy of varicose veins and venous malformations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise diagnosis of DVT of the legs is a challenging problem, not only in front of suspicion of PE, but also in all status of leg pain, warmth and swelling. Clinical diagnosis has a low accuracy and further investigations are mandatory in order to diagnose DVT. Amongst the possible investigations, US has a high specificity and a good NPV. However, many pathologies unrelated to the veins may mimic the signs and symptoms of DVT and have to be recognized in order to make the correct diagnosis. The purpose of this paper is to review the results of the US investigations of the legs performed in our Department during the last three years for a suspicion of DVT and describe alternative diagnoses mimicking DVT. Methods and materials: Through a RIS-based search, we retrospectively reviewed all the cases of US of the legs performed in our Department between January 2006 and December 2008 for a suspicion of DVT. We selected the cases of positive findings unrelated to the veins and illustrated these findings with characteristic images. Results: 419 US of the legs were performed between December 2006 and December 2008 for a suspicion of DVT. Among these, 75 were positive for DVT, and 79 for alternative diagnosis. The most common alternative diagnosis was edema of the legs (31%), followed by hematoma (23%). Other findings were Baker cysts (13%), cellulitis (10%) and lymphoceles (5%). Rare diagnoses were arterio-venous malformations, pseudoaneurysms, pelvic masses, necrosing fasciitis, intramuscular abscesses, subcutaneous seromas, sarcoma and ganglion cysts. Conclusion: A greater knowledge of the US appearance of the pathologies mimicking DVT may help to make the correct diagnosis, avoiding further expensive investigations or inappropriate anticoagulant therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new plastic self-expanding Smartcanula (Smartcanula LLC, Lausanne, Switzerland) is designed for central insertion and prevention of caval collapse. The objective of our work is to assess the influence of the new design on atrial chatter. Caval collapse over the entire caval axis, right atrial, hepatic, renal vein, and iliac vein is realized in drainage tubes with holes at 5 cm distance intervals. Smartcanulas with various lengths (26 cm [= right atrial], 34 cm [= hepatic], 43 cm [= renal], and 53 cm [= iliac]) versus two-stage cannulas are compared. Pressure drop (ΔP) is measured using Millar pressure-transducers. Flow rate (Q) is measured using an ultrasonic flow meter. Cannula resistance is defined as the ΔP/Q ratio. Data display and recording are controlled using LabView virtual instruments. At an 88 cm height differential, Q values are 8.69 and 6.8 l/min, and ΔP/Q ratios are 0.63 and 1.28 for the 26-cm Smartcanula and the reference cannula, respectively. The 34-cm Smartcanula showed 8.89 l/min and 0.6 ΔP/Q ratio vs. 7.59 l/min and 0.9 for the control cannula (P < 0.05). The 43-cm and 53-cm Smartcanulas showed Q values of 9.04 and 8.81 l/min, respectively, and ΔP/Q2 ratio of 0.6. The Smartcanula outperforms the two-stage cannula, and direct cannula insertion without guide wire is effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Developmental venous anomaly (DVA) is considered a benign and asymptomatic cerebrovascular malformation, and only isolated cases of symptomatic DVAs are described in the literature. Even more rarely will these symptoms come from an intraparenchymal hemorrhage caused by the DVA. METHODS AND RESULTS: We present two symptomatic DVAs by intracerebellar hemorrhage. CONCLUSION: The diagnostic steps regarding the pathophysiology of DVA hemorrhage and the treatment options are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The superficial femoral vein (SFV) is a well-established alternative conduit for infra-inguinal reconstructivenous hypertension after SFV harvest may however result in significant morbidity. This study reports the efficiency of SFV as conduit for infra-inguinal reconstructions and characterize the anatomic and physiologic changes in harvest limbs and their relationship to the development of venous complications. METHODS: From May 1999 through November 2003, 23 SFV were harvested from 21 patients undergoing infra-inguinal reconstructions. Bypasses were controlled by regular duplex-ultrasound. The venous morbidity was assessed by measurements of leg circumferences, strain-gauge plethysmography and quality of life, investigated by the VEINES-QOL scale. RESULTS: At a mean follow-up of 10.4 months (range 1-56), primary, secondary patency and limb salvage rates of infra-inguinal bypasses using SFV are 71.4%, 76.2% and 85.7% respectively. No patient had major venous claudication. Oedema was significantly present in nine patients. Strain-gauge plethysmography showed outflow obstruction in all patients. The VEINES-QOL assessment showed no limitation in social and domestic activity, moderate complain about leg heaviness despite presence of oedema. CONCLUSION: The SFV harvest is a reliable conduit for infra-inguinal reconstructions and results in moderate venous morbidity in terms of functional consequences and quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the hemodynamic effects of L-canavanine (an inhibitor of inducible, but not of constitutive, nitric oxide synthase) in endotoxic shock. DESIGN: Controlled, randomized, experimental study. SETTING: Animal laboratory. SUBJECTS: Wistar rats. INTERVENTIONS: Rats were anesthetized with pentobarbital, and hemodynamically monitored. One hour after an intravenous challenge with 5 mg/kg of Escherichia coli endotoxin, the rats were randomized to receive a continuous infusion of either L-canavanine (20 mg/kg/hr; n = 8) or vehicle only (isotonic saline, n = 11). In all animals, the infusion was given over 5 hrs at a rate of 2 mL/kg/hr. These experiments were repeated in additional rats challenged with isotonic saline instead of endotoxin (sham experiments). MEASUREMENTS AND MAIN RESULTS: Arterial blood pressure, heart rate, thermodilution cardiac output, central venous pressure, mean systemic filling pressure, urine output, arterial blood gases, blood lactate concentration, and hematocrit were measured. In sham experiments, hemodynamic stability was maintained throughout and L-canavanine had no detectable effect. Animals challenged with endotoxin and not treated with L-canavanine developed progressive hypotension and low cardiac output. After 6 hrs of endotoxemia, both central venous pressure and mean systemic filling pressure were significantly below their baseline values, indicating relative hypovolemia as the main determinant of reduced cardiac output. In endotoxemic animals treated with L-canavanine, hypotension was less marked, while cardiac output, central venous pressure, and mean systemic filling pressure were maintained throughout the experiment. L-canavanine had no effect on the time-course of hematocrit. L-canavanine significantly increased urine output and reduced the severity of lactic acidosis. CONCLUSIONS: Six hours after an endotoxin challenge in rats, low cardiac output develops, which appears to be primarily related to relative hypovolemia. L-canavanine, a selective inhibitor of the inducible nitric oxide synthase, increases the mean systemic filling pressure, thereby improving venous return, under these conditions.