943 resultados para Umbilical Arteries


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The umbilical cord is not an inert structure, suspended between the fetus and placenta, but it plays an active role and it is involved in several processes afflicting the feto-placental unit. Its study has to be regarding not only its morphology and morphometry, and the impendance of blood flow by Doppler waveform analysis, but it includes also an analysis of the coiling type and the amount of the Wharton Jelly. The umbilical cord has been considered like an important and huge source of informations, useful to assess the well-being of the fetus and the outcome of pregnancy. The standardization of ultrasound techniques is the first step to speak the same language and make the study of this structure a fundamental part of well-being fetus assessment. This article is carefully focused on morphologic, morphometric and functional ultrasound examination of umbilical cord and suggests that any anomaly detected should provide an indication for an intense fetal follow-up, useful for early helpful therapy, preventing serious complication for the pregnancy.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two young women with angiographically normal coronary arteries suffered an acute myocardial infarction. Both were found to have a patent foramen ovale (PFO), the likely pathway of a paradoxical embolus causing the infarction. The PFOs were diagnosed and closed percutaneously with an Amplatzer PFO Occluder during the emergency coronary angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study analyzes the results of the arterial switch operation for transposition of the great arteries in member institutions of the European Congenital Heart Surgeons Association. METHODS: The records of 613 patients who underwent primary arterial switch operations in each of 19 participating institutions in the period from January 1998 through December 2000 were reviewed retrospectively. RESULTS: A ventricular septal defect was present in 186 (30%) patients. Coronary anatomy was type A in 69% of the patients, and aortic arch pathology was present in 20% of patients with ventricular septal defect. Rashkind septostomy was performed in 75% of the patients, and 69% received prostaglandin. There were 37 hospital deaths (operative mortality, 6%), 13 (3%) for patients with an intact ventricular septum and 24 (13%) for those with a ventricular septal defect (P < .001). In 36% delayed sternal closure was performed, 8% required peritoneal dialysis, and 2% required mechanical circulatory support. Median ventilation time was 58 hours, and intensive care and hospital stay were 6 and 14 days, respectively. Although of various preoperative risk factors the presence of a ventricular septal defect, arch pathology, and coronary anomalies were univariate predictors of operative mortality, only the presence of a ventricular septal defect approached statistical significance (P = .06) on multivariable analysis. Of various operative parameters, aortic crossclamp time and delayed sternal closure were also univariate predictors; however, only the latter was an independent statistically significant predictor of death. CONCLUSIONS: Results of the procedure in European centers are compatible with those in the literature. The presence of a ventricular septal defect is the clinically most important preoperative risk factor for operative death, approaching statistical significance on multivariable analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A neonatal case of umbilical evagination of the bladder combined with a small omphalocele is presented. This rare congenital malformation has previously been described in only three cases. Umbilical evagination can be understood as a disturbance of development of both the vitelline and allantoic ducts, resulting in a non-descended but otherwise normal bladder opening to the inferior margin of a small omphalocele. Diagnosis is made by clinical inspection and ultrasound. Since other malformations are not present, this entity may be regarded as a minor form of a lower midline defect with excellent prognosis.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The patency rate of radial artery (RA) conduits is considerably lower than that of internal thoracic artery (ITA) grafts and the evidence suggests that this is due to a clinically suspected higher incidence of vasospasm. The aim of this study was, therefore, to compare intraindividually the pharmacological reactivity of RA with that of ITA. Both RA and ITA were taken from the same patients and investigated in parallel. Changes in tone were monitored isometrically on ring preparations from both arteries in organ baths with modified Krebs-Henseleit solution containing 1.25 mm calcium chloride at 1 g passive preload. In intraindividual comparisons maximal receptor-mediated contractile responses to noradrenaline and endothelin-1 and endothelium-dependent acetylcholine-induced relaxant responses revealed no differences between both arteries. By contrast, depolarization-induced contractions to potassium chloride (KCl) appeared to be significantly higher in RA than in ITA. Further analysis, however, revealed that this difference was due to preoperative calcium entry blocker (Ca(2+)eB) therapy. Compared with control tissues, maximal responses to KCl were significantly attenuated in the ITA but unchanged in RA when arteries were obtained from patients with preoperative Ca(2+)eB therapy. The present results suggested that functional responses to pharmacological stimuli of both RA and ITA were quite similar. Preoperative Ca(2+)eB therapy, however, attenuated markedly responses to KCl of the ITA leaving those of RA unchanged. These results, demonstrating a lower sensitivity to Ca(2+)eB of RA, therefore suggested that in addition to Ca(2+)eB other classes of drug may be more effective at reducing the propensity of RA conduits to vasospasm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endovascular therapy is a rapidly evolving field for the treatment of patients with peripheral arterial disease, and a magnitude of studies reporting on various modern revascularization concepts have been recently published. Thus, studies assessing the efficacy of endovascular therapy of peripheral arteries do not operate with uniformly defined endpoints, rendering a direct comparison of studies difficult. The purpose of this consensus statement is to highlight differences in the terminology used in the current literature and to propose some standardized criteria that must be considered when reporting results of endovascular revascularization for chronic ischaemia of lower limb arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine the accuracy of automated vessel-segmentation software for vessel-diameter measurements based on three-dimensional contrast-enhanced magnetic resonance angiography (3D-MRA). METHOD: In 10 patients with high-grade carotid stenosis, automated measurements of both carotid arteries were obtained with 3D-MRA by two independent investigators and compared with manual measurements obtained by digital subtraction angiography (DSA) and 2D maximum-intensity projection (2D-MIP) based on MRA and duplex ultrasonography (US). In 42 patients undergoing carotid endarterectomy (CEA), intraoperative measurements (IOP) were compared with postoperative 3D-MRA and US. RESULTS: Mean interoperator variability was 8% for measurements by DSA and 11% by 2D-MIP, but there was no interoperator variability with the automated 3D-MRA analysis. Good correlations were found between DSA (standard of reference), manual 2D-MIP (rP=0.6) and automated 3D-MRA (rP=0.8). Excellent correlations were found between IOP, 3D-MRA (rP=0.93) and US (rP=0.83). CONCLUSION: Automated 3D-MRA-based vessel segmentation and quantification result in accurate measurements of extracerebral-vessel dimensions.