Resumo:
Implant topography is an important factor that influences many cell types. To understand the role of topography in the inflammatory events, we evaluated the response of human gingival fibroblasts (HGFs) by the release pattern of cytokines. HGFs were cultured on Ti discs for 24 and 48 h. Four different surface treatments were used: machining method (turned), blasting followed by an acid-etching method (BAE), oxidative nanopatterning (ON) method, and an association of blasting followed by an acid-etching plus oxidative nanopatterning (BAE+ON) method. Extracellular levels of IL-6, IL-8, transforming growth factor beta (TGF-beta), IL-4, and IL-10 were measured by enzyme-linked immunosorbant assay. Increased levels of IL-6 and IL-8 were observed in all surfaces after 24 h which decreased after 48 h. BAE, ON, and BAE+ON surfaces showed a reduction in IL-6 levels compared with the turned after 48 h (p < 0.05). On one hand, IL-8 production was lower in BAE+ON in comparison to the turned surface (p < 0.05). On the other hand, IL-4 showed increased levels with 48 h, which were significantly different between turned, BAE, and ON surfaces, but not with BAE+ON. Additionally, TGF-beta and IL-10 production were not detected. This study indicates that nanotopography might be important in the modulation of the inflammatory response in cultured HGFs. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A 100A:2629-2636, 2012.
Resumo:
Tribochemical silica-coating is the recommended conditioning method for improving glass-infiltrated alumina composite adhesion to resin cement. High-intensity lasers have been considered as an alternative for this purpose. This study evaluated the morphological effects of Er,Cr:YSGG laser irradiation on aluminous ceramic, and verified the microtensile bond strength of composite resin to ceramic following silica coating or laser irradiation. In-Ceram Alumina ceramic blocks were polished, submitted to airborne particle abrasion (110 mu m Al(2)O(3)), and conditioned with: (CG) tribochemical silica coating (110 mu m SiO(2)) + silanization (control group); (L1-L10) Er,Cr:YSGG laser (2.78 mu m, 20 Hz, 0.5 to 5.0 W) + silanization. Composite resin blocks were cemented to the ceramic blocks with resin cement. These sets were stored in 37A degrees C distilled water (24 h), embedded in acrylic resin, and sectioned to produce bar specimens that were submitted to microtensile testing. Bond strength values (MPa) were statistically analyzed (alpha a parts per thousand currency sign0.05), and failure modes were determined. Additional ceramic blocks were conditioned for qualitative analysis of the topography under SEM. There were no significant differences among silicatization and laser treatments (p > 0.05). Microtensile bond strength ranged from 19.2 to 27.9 MPa, and coefficients of variation ranged from 30 to 55%. Mixed failure of adhesive interface was predominant in all groups (75-96%). No chromatic alteration, cracks or melting were observed after laser irradiation with all parameters tested. Surface conditioning of glass-infiltrated alumina composite with Er,Cr:YSGG laser should be considered an innovative alternative for promoting adhesion of ceramics to resin cement, since it resulted in similar bond strength values compared to the tribochemical treatment.
Resumo:
The aim of this study was to evaluate the shear bond strength of repairs in porcelain conditioned with laser. Sixty porcelain discs were made and six groups were formed (n = 10): G1: conditioning with laser with potency 760 mW; G2: conditioning with laser with potency 760 mW and application of 37% phosphoric acid for 15 s; G3: conditioning with laser with potency 900 mW; G4: conditioning with laser with potency 900 mW and application of 37% phosphoric acid for 15 s; G5: application of 37% phosphoric acid for 15 s (group control) and G6: application of 10% hydrofluoric acid for 2 min. The composite resin was insert of incremental layers at the porcelain surface aided with a metal matrix, and photoactivation for 20 s each increment. The specimens were submitted to a thermal cycling by 1000 cycles of 30 s in each bath with temperature between 5 and 55 degrees C. After the thermal cycling, specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance and Tukey's tests with 5% significance. The averages and standard deviation founded were: G1, 11.25 (+/- 3.10); G2, 12.32 (+/- 2.65); G3, 14.02 (+/- 2.38); G4, 13.44 (+/- 2,07); G5, 9.91 (-/+ 2,18); G6, 12.74 (+/- 2.67). The results showed that the femtosecond laser produced a shear bond strength of repairs in porcelain equal to the hydrofluoric acid and significantly superior to the use of phosphoric acid. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.
Resumo:
Il presente lavoro parte dalla descrizione dei processi di rimodellamento osseo mascellare a seguito della perdita di elementi dentari e la successiva riabilitazione mediante impianto dentale osteointegrato. Approfondiremo proprio i complessi aspetti dell’osteointegrazione su superfici implantari in titanio sia a livello micro che macroscopico. Nel campo dell’implantologia, infatti, il titanio risulta essere il materiale maggiormente impiegato in virtù della sua eccellente biocompatibilità e resistenza. Successivamente prenderemo in analisi i trattamenti di superficie implantare ad oggi più diffusi, lavorati prevalentemente a livello microscopico e infine confronteremo una sistematica trattata tradizionalmente con una innovativa trattata superficialmente a livello nanometrico. Il confronto avverrà in vivo, paragonando i risultati ottenuti clinicamente e radiograficamente tra le 2 sistematiche implantari, utilizzate per ripristinare la funzione masticatoria nei pazienti arruolati.
Resumo:
The rehabilitation of concrete structures, especially concrete bridge decks, is a major challenge for transportation agencies in the United States. Often, the most appropriate strategy to preserve or rehabilitate these structures is to provide some form of a protective coating or barrier. These surface treatments have typically been some form of polymer, asphalt, or low-permeability concrete, but the application of UHPC has shown promise for this application mainly due to its negligible permeability, but also as a result of its excellent mechanical properties, self-consolidating nature, rapid gain strength, and minimal creep and shrinkage characteristics. However, for widespread acceptance, durability and performance of the composite system must be fully understood, specifically the bond between UHPC and NSC often used in bridge decks. It is essential that the bond offers enough strength to resist the stress due to mechanical loading or thermal effects, while also maintaining an extended service-life performance. This report attempts to assess the bond strength between UHPC and NSC under different loading configurations. Different variables, such as roughness degree of the concrete substrates, age of bond, exposure to freeze-thaw cycles and wetting conditions of the concrete substrate, were included in this study. The combination of splitting tensile test with 0, 300, 600 and 900 freeze-thaw cycles was carried out to assess the bond performance under severe ambient conditions. The slant-shear test was utilized with different interface angles to provide a wide understanding of the bond performance under different combinations of compression and shear stresses. The pull-off test is the most accepted method to evaluate the bond strength in the field. This test which studies the direct tensile strength of the bond, the most severe loading condition, was used to provide data that can be correlated with the other tests that only can be used in the laboratory. The experimental program showed that the bond performance between UHPC and NSC is successful, as the strength regardless the different degree of roughness of the concrete substrate, the age of the composite specimens, the exposure to freeze-thaw cycles and the different loading configurations, is greater than that of concrete substrate and largely satisfies with ACI 546.3R-06.
Resumo:
The end-notched flexure (ENF) test calculates the value of mode II fracture energy in adhesive bonding between the substrates of same nature. Traditional methods of calculating fracture energy in the ENF test are not suitable in cases where the thickness of the adhesive is non-negligible compared with adherent thicknesses. To address this issue, a specific methodology for calculating mode II fracture energy has been proposed in this paper. To illustrate the applicability of the proposed method, the fracture energy was calculated by the ENF test for adhesive bonds between aluminium and a composite material, which considered two different types of adhesive (epoxy and polyurethane) and various surface treatments. The proposed calculation model provides higher values of fracture energy than those obtained from the simplified models that consider the adhesive thickness to be zero, supporting the conclusion that the calculation of mode II fracture energy for adhesives with non-negligible thickness relative to their adherents should be based on mathematical models, such as the method proposed in this paper, that incorporate the influence of this thickness.
Resumo:
(SPA)Las propiedades mecánicas de las uniones adhesivas no solo dependen de la naturaleza y propiedades de los adhesivos; hay muchos otros parámetros que influyen directamente en el comportamiento de las uniones adhesivas. Algunos de los más significativos son: el acabado superficial de los materiales, área y espesor de la capa adhesiva, un diseño adecuado, secuencia de aplicación, propiedades químicas de la superficie y preparación de los sustratos antes de aplicar el adhesivo. La resistencia mecánica de las uniones adhesivas está íntimamente relacionada con el proceso de rotura, directamente dependiente del mecanismo cohesión-adhesión. El objeto de este trabajo es analizar la influencia de dos acabados superficiales diferentes, sobre el comportamiento a fatiga de uniones con adhesivo epoxi. Los resultados muestran que la compatibilidad química entre el adhesivo y la capa prepintada mejora la adhesión de las uniones y la resistencia mecánica frente a cargas estáticas y dinámicas. Se ha obtenido el límite de fatiga para las uniones de ambas superficies. (ENG)The mechanical properties of adhesive joints depend not only on the nature and properties of the adhesives; there are many parameters which influence the behaviour of the adhesive joints. Some of more significant parameters are: the surface conditions of materials, area and thickness of adhesive layer, compatibility of the design, applying sequence, chemical properties of surface and the surface treatments of substrates prior to be bonded. The mechanical resistance of adhesive joints is interrelated to the fracture process depended on cohesion-adhesion mechanism. The aim of this paper is analyse the influence of two different surfaces on the fatigue behaviour of epoxy adhesive joints. The results show that chemical compatibility of adhesive and paint improve adhesion of joints and the mechanical resistance against static and dynamic loads. The fatigue limited has been obtained for joints with both surfaces.
Resumo:
Los adhesivos se conocen y han sido utilizados en multitud de aplicaciones a lo lago de la historia. En la actualidad, la tecnología de la adhesión como método de unión de materiales estructurales está en pleno crecimiento. Los avances científicos han permitido comprender mejor los fenómenos de adhesión, así como, mejorar y desarrollar nuevas formulaciones poliméricas que incrementan el rango de aplicaciones de los adhesivos. Por otro lado, el desarrollo de nuevos materiales y la necesidad de aligerar peso, especialmente en el sector transporte, hace que las uniones adhesivas se introduzcan en aplicaciones hasta ahora reservadas a otros sistemas de unión como la soldadura o las uniones mecánicas, ofreciendo rendimientos similares y, en ocasiones, superiores a los aportados por estas. Las uniones adhesivas ofrecen numerosas ventajas frente a otros sistemas de unión. En la industria aeronáutica y en automoción, las uniones adhesivas logran una reducción en el número de componentes (tales como los tornillos, remaches, abrazaderas) consiguiendo como consecuencia diseños más ligeros y una disminución de los costes de manipulación y almacenamiento, así como una aceleración de los procesos de ensamblaje, y como consecuencia, un aumento de los procesos de producción. En el sector de la construcción y en la fabricación de equipos industriales, se busca la capacidad para soportar la expansión y contracción térmica. Por lo tanto, se usan las uniones adhesivas para evitar producir la distorsión del sustrato al no ser necesario el calentamiento ni la deformación de las piezas cuando se someten a un calentamiento elevado y muy localizado, como en el caso de la soldadura, o cuando se someten a esfuerzos mecánicos localizados, en el caso de montajes remachados. En la industria naval, se están desarrollando técnicas de reparación basadas en la unión adhesiva para distribuir de forma más uniforme y homogénea las tensiones con el objetivo de mejorar el comportamiento frente a fatiga y evitar los problemas asociados a las técnicas de reparación habituales de corte y soldadura. Las uniones adhesivas al no requerir importantes aportes de calor como la soldadura, no producen modificaciones microestructurales indeseables como sucede en la zona fundida o en la zona afectada térmicamente de las uniones soldadas, ni deteriora los recubrimientos protectores de metales de bajo punto de fusión o de naturaleza orgánica. Sin embargo, las uniones adhesivas presentan una desventaja que dificulta su aplicación, se trata de su durabilidad a largo plazo. La primera causa de rotura de los materiales es la rotura por fatiga. Este proceso de fallo es la causa del 85% de las roturas de los materiales estructurales en servicio. La rotura por fatiga se produce cuando se somete al material a la acción de cargas que varían cíclicamente o a vibraciones durante un tiempo prolongado. Las uniones y estructuras sometidas a fatiga pueden fallar a niveles de carga por debajo del límite de resistencia estática del material. La rotura por fatiga en las uniones adhesivas no se produce por un proceso de iniciación y propagación de grieta de forma estable, el proceso de fatiga va debilitando poco a poco la unión hasta que llega un momento que provoca una rotura de forma rápida. Underhill explica este mecanismo como un proceso de daño irreversible de los enlaces más débiles en determinados puntos de la unión. Cuando se ha producido el deterioro de estas zonas más débiles, su área se va incrementando hasta que llega un momento en que la zona dañada es tan amplia que se produce el fallo completo de la unión. En ensayos de crecimiento de grieta realizados sobre probetas preagrietadas en viga con doble voladizo (DCB), Dessureault identifica los procesos de iniciación y crecimiento de grietas en muestras unidas con adhesivo epoxi como una acumulación de microfisuras en la zona próxima al fondo de grieta que, luego, van coalesciendo para configurar la grieta principal. Lo que supone, igualmente, un proceso de daño del adhesivo en la zona de mayor concentración de tensiones que, posteriormente, conduce al fallo de la unión. La presente tesis surge con el propósito de aumentar los conocimientos existentes sobre el comportamiento a fatiga de las uniones adhesivas y especialmente las realizadas con dos tipos de adhesivos estructurales aplicados en aceros con diferentes acabados superficiales. El estudio incluye la obtención de las curvas de tensión frente al número de ciclos hasta el fallo del componente, curvas SN o curvas de Wöhler, que permitirán realizar una estimación de la resistencia a la fatiga de un determinado material o estructura. Los ensayos de fatiga realizados mediante ciclos predeterminados de carga sinusoidales, de amplitud y frecuencia constantes, han permitido caracterizar el comportamiento a la fatiga por el número de ciclos hasta la rotura, siendo el límite de fatiga el valor al que tiende la tensión cuando el número de ciclos es muy grande. En algunos materiales, la fatiga no tiende a un valor límite sino que decrece de forma constante a medida que aumenta el número de ciclos. Para estas situaciones, se ha definido la resistencia a la fatiga (o límite de resistencia) por la tensión en que se produce la rotura para un número de ciclos predeterminado. Todos estos aspectos permitirán un mejor diseño de las uniones y las condiciones de trabajo de los adhesivos con el fin de lograr que la resistencia a fatiga de la unión sea mucho más duradera y el comportamiento total de la unión sea mucho mejor, contribuyendo al crecimiento de la utilización de las uniones adhesivas respecto a otras técnicas. ABSTRACT Adhesives are well-known and have been used in many applications throughout history. At present, adhesion bonding technology of structural materials is experiencing an important growth. Scientific advances have enabled a better understanding of the phenomena of adhesion, as well as to improve and develop new polymeric formulations that increase the range of applications. On the other hand, the development of new materials and the need to save weight, especially in the transport sector, have promote the use of adhesive bonding in many applications previously reserved for other joining technologies such as welded or mechanical joints, presenting similar or even higher performances. Adhesive bonding offers many advantages over other joining methods. For example, in the aeronautic industry and in the automation sector, adhesive bonding allows a reduction in the number of components (such as bolts, rivets, clamps) and as consequence, resulting in lighter designs and a decrease in handling and storage costs, as well as faster assembly processes and an improvement in the production processes. In the construction sector and in the industrial equipment manufacturing, the ability to withstand thermal expansion and contraction is required. Therefore, adhesion bonding technology is used to avoid any distortion of the substrate since this technology does not require heating nor the deformation of the pieces when these are exposed to very high and localized heating, as in welding, or when are subjected to localized mechanical stresses in the case of riveted joints. In the naval industry, repair techniques based in the adhesive bonding are being developed in order to distribute stresses more uniform and homogeneously in order to improve the performance against fatigue and to avoid the problems associated with standard repair techniques as cutting and welding. Adhesive bonding does not require the use of high temperatures and as consequence they do not produce undesirable microstructural changes, as it can be observed in molten zones or in heat-affected zones in the case of welding, neither is there damage of the protective coating of metals with low melting points or polymeric films. However, adhesive bonding presents a disadvantage that limits its application, the low longterm durability. The most common cause of fractures of materials is fatigue fracture. This failure process is the cause of 85% of the fracture of structural materials in service. Fatigue failure occurs when the materials are subjected to the action of cyclic loads or vibrations for a long period of time. The joints and structures subjected to fatigue can fail at stress values below the static strength of the material. Fatigue failure do not occurs by a static and homogeneous process of initiation and propagation of crack. The fatigue process gradually weakens the bond until the moment in which the fracture occurs very rapidly. Underhill explains this mechanism as a process of irreversible damage of the weakest links at certain points of the bonding. When the deterioration in these weaker zones occurs, their area increase until the damage zone is so extensive that the full failure of the joint occurs. During the crack growth tests performed on precracked double-cantilever beam specimen, (DCB), Dessureault identified the processes of crack initiation and growth in samples bonded with epoxy adhesive as a process of accumulation of microcracks on the zone near the crack bottom, then, they coalesced to configure the main crack. This is a damage process of the adhesive in the zone of high stress concentration that leads to failure of the bond. This thesis aims to further the understanding of the fatigue behavior of the adhesive bonding, primarily those based on two different types of structural adhesives used on carbon-steel with different surface treatments. This memory includes the analysis of the SN or Wöhler curves (stress vs. number of cycles curves up to the failure), allowing to carry out an estimation of the fatigue strength of a specific material or structure. The fatigue tests carried out by means of predetermined cycles of sinusoidal loads, with a constant amplitude and frequency, allow the characterisation of the fatigue behaviour. For some materials, there is a maximum stress amplitude below which the material never fails for any number of cycles, known as fatigue limit. In the other hand, for other materials, the fatigue does not tend toward a limit value but decreases constantly as the number of cycles increases. For these situations, the fatigue strength is defined by the stress at which the fracture occurs for a predetermined number of cycles. All these aspects will enable a better joint design and service conditions of adhesives in order to get more durable joints from the fatigue failure point of view and in this way contribute to increase the use of adhesive bonding over other joint techniques.
Resumo:
In this work we have realized plasma diagnosis produced by Laser (LPP), by means of emission spectroscopy in a Laser Shock Processing (LSP). The LSP has been proposed as an alternative technology, competitive with classical surface treatments. The ionic species present in the plasma together with electron density and its temperature provide significant indicators of the degree of surface effect of the treated material. In order to analyze these indicators, we have realized spectroscopic studies of optical emission in the laser-generated plasmas in different situations. We have worked focusing on an aluminum sample (Al2024) in air and/or in LSP conditions (water flow) a Q-switched laser of Nd:YAG (λ = 1.06 μm, 10 ns of pulse duration, running at 10 Hz repetition rate). The pulse energy was set at 2,5 J per pulse. The electron density has been measured using, in every case, the Stark broadening of H Balmer α line (656.27 nm). In the case of the air, this measure has been contrasted with the value obtained with the line of 281.62 nm of Al II. Special attention has been paid to the self-absorption of the spectral lines used. The measures were realized with different delay times after the pulse of the laser (1–8 μs) and with a time window of 1 μs. In LSP the electron density obtained was between 1017 cm−3 for the shortest delays (4–6 μs), and 1016 cm−3 for the greatest delays (7,8 μs).
Resumo:
Este estudo possui duas partes distintas: 1. in vivo (randomizado e longitudinal) que teve como objetivo avaliar protocolos de tratamento para hipersensibilidade dentinária com laser de baixa potência (com diferentes dosagens), laser de alta potência e agente dessensibilizante, por um período de 12 e 18 meses; e 2. in vitro que teve como objetivo analisar a perda de estrutura de dois dentifrícios distintos (Colgate Total 12 e Colgate Pró Alívio) e analisar a permeabilidade dentinária dos tratamentos da etapa 01, associados aos dentifrícios, após diferentes ciclos de abrasão. Na parte in vivo, as lesões cervicais não cariosas de 32 voluntários, previamente submetidos aos critérios de elegibilidade ou exclusão, foram divididas em nove grupos (n=10): G1: Gluma Desensitizer (Heraeus Kulzer), G2: Laser de baixa potência com baixa dosagem (Photon Lase, DMC) (três pontos de irradiação vestibulares e um ponto apical: 30 mW, 10 J/cm2, 9 seg por ponto com o comprimento de onda de 810nm). Foram realizadas três sessões com um intervalo de 72 horas), G3: Laser de baixa potência com alta dosagem (um ponto cervical e um ponto apical: 100 mW, 90 J/cm2, 11 seg por ponto com o comprimento de onda de 810nm. Foram realizadas três sessões com um intervalo de 72 horas), G4: Laser de baixa potência com baixa dosagem + Gluma Desensitizer, G5: Laser de baixa potência com alta dosagem + Gluma Desensitizer, G6: Laser de Nd:YAG (Power LaserTM ST6, Lares Research®), em contato com a superfície dental: 1,0W, 10 Hz e 100 mJ, ? 85 J/cm2, com o comprimento de onda de 1064nm, G7: Laser de Nd:YAG + Gluma Desensitizer, G8: Laser de Nd:YAG + Laser de baixa potência com baixa dosagem, G9: Laser de Nd:YAG + Laser de baixa potência com alta dosagem. O nível de sensibilidade de cada voluntário foi avaliado através da escala visual analógica de dor (VAS) com auxílio do ar da seringa tríplice e exploração com sonda após 12 e 18 meses do tratamento. Na parte 02, in vitro, foram utilizados terceiros molares humanos não irrompidos e recém-extraídos. Todos foram limpos e tiveram suas raízes separadas das coroas. As raízes foram seccionadas em quadrados de dentina com dimensões de 4x4x2 mm, os quais foram embutidos em resina Epoxi e devidamente polidos até uma curvatura de 0,3 ?m, analisados em perfilometria ótica. Estes foram imersos em solução de EDTA 17% por 2min para abertura dos túbulos e armazenados em uma solução de Soro Fetal Bovino diluído em salina tamponada com fosfato. Os espécimes foram divididos aleatoriamente em 12 grupos (n=10) G1: Sem tratamento de superfície, sem dentifrício; G2: Nd:YAG/sem dentifrício; G3: Gluma/sem dentifrício; G4: Nd:YAG + Gluma/sem dentifrício; G5: Sem tratamento de superfície/Colgate Total 12; G6: Nd:YAG/Colgate Total 12; G7: Gluma/Colgate Total 12; G8: Nd:YAG + Gluma/Colgate Total 12; G9: Sem tratamento de superfície/Colgate Pró Alívio; G10: Nd:YAG/Colgate Pró Alívio; G11: Gluma/Colgate Pró Alívio; G12: Nd:YAG + Gluma/Colgate Pró Alívio. Em seguida, as superfícies receberam a aplicação de fitas adesivas nas duas margens, mantendo uma área central de teste exposta de 4 x 1 mm, onde foram realizados os tratamentos de superfície e os ciclos de abrasão correspondentes a 1, 7, 30 e 90 dias de escovação (52 ciclos, 210 segundos de contato com o slurry; 361 ciclos, 1470 segundos de contato com o slurry; 1545 ciclos, 6300 segundos de contato com o slurry; 4635 ciclos, 18900 segundos de contato com o slurry, respectivamente). A cada etapa de abrasão, foi realizada análise em Perfilometria Ótica. Para as analises de permeabilidade e Microscopia Eletrônica de Varredura, foram utilizadas amostras circulares de 6 mm de diâmetro e 1 mm de espessura de dentina obtidas das coroas dentais. Estas foram divididas aleatoriamente nos mesmos grupos já descritos anteriormente, sendo que 120 espécimes foram utilizados para permeabilidade (n=10) e 36 para MEV (n=3). Ambas as análises foram realizadas após imersão no EDTA; após tratamentos para a sensibilidade; pós 1 dia, 7 dias, 30 dias e 90 dias de escovação. Após análise estatística pode-se concluir que, in vivo, todos os tratamentos foram eficazes para a redução da hipersensibilidade dentinária. Ainda que o nível da sensibilidade dos pacientes aumentou numericamente, estes não são considerados estatisticamente diferentes a partir de 12 meses. Portanto, até a avaliação de 18 meses, podemos concluir que não houve um aumento na sensibilidade dentinária desde a sua diminuição pós-tratamento. In vitro, pode-se concluir que todos os tratamentos foram capazes de diminuir a permeabilidade dentinária. O dentifrício Total 12 apresentou-se como o mais abrasivo em comparação com o dentifrício Pro Alivio, pois este último promoveu uma perda de estrutura menor, porém ambos não apresentaram aumento na permeabilidade nos tempos de escovação. As microscopias eletrônicas de varredura mostram a formação da smear layer, obliterando os túbulos para ambos os dentifricios. Como conclusão, pode-se afirmar que todos os agentes dessensibilizantes foram efetivos, mesmo apresentando estratégias de ação diferentes. Os dentifrícios são igualmente interessantes para o uso caseiro por ocasionarem oclusão tubular e a associação de tratamentos (caseiro e de consultório) parece ser uma alternativa eficaz no tratamento da hipersensibilidade dentinária.
Resumo:
El objetivo principal de la presente investigación ha sido desarrollar una nueva clase de materiales nanocompuestos orgánicos-inorgánicos basados en la capacidad de los copolímeros de bloque de auto-organizarse promoviendo la dispersión de nanopartículas, así como relacionar las diferentes morfologías obtenidas con las propiedades finales de los nanocompuestos. Para generar la nanoestructuración de estos nanocompuestos basados en copolímeros de bloque, como el poli(estireno-b-isopreno-b-estireno) (SIS) y el poli(estireno-b-butadieno-b-estireno) (SBS) en nanopartículas de plata, se han utilizado los conceptos de compatibilización y confinamiento. Es decir, las nanopartículas inorgánicas se confinaron en una sola fase del copolímero de bloque mediante tratamientos superficiales y su funcionalización física. En particular, se utilizaron surfactantes (el cloruro de tetrametilamonio, TMAC, y el dodecanotiol, DT) para favorecer la interacción entre las nanopartículas inorgánicas y la matriz polimérica. Teniendo en cuenta los cálculos teóricos de los parámetros de solubilidad obtenidos mediante la teoría de Hoftizer-Van Krevelen, y la electronegatividad propia de los diferentes elementos, los dos surfactantes elegidos tienen una muy buena compatibilidad con el bloque de estireno favoreciendo la localización de las nanopartículas de plata en este bloque.
Resumo:
This thesis describes an experimental study of the abrasion resistance of concrete at both the macro and micro levels. This is preceded by a review related to friction and wear, methods of test for assessing abrasion resistance, and factors influencing the abrasion resistance of concrete. A versatile test apparatus was developed to assess the abrasion resistance of concrete. This could be operated in three modes and a standardised procedure was established for all tests. A laboratory programme was undertaken to investigate the influence, on abrasion resistance, of three major factors - finishing techniques, curing regimes and surface treatments. The results clearly show that abrasion resistance was significantly affected by these factors, and tentative mechanisms were postulated to explain these observations. To substantiate these mechanisms, the concrete specimens from the macro-study were subjected to micro-structural investigation, using such techniques as 'Mercury Intrusion Forosimetry, Microhardness, Scanning Electron Microscopy, Petrography and Differential Thermal Analysis. The results of this programme clearly demonstrated that the abrasion resistance of concrete is primarily dependent on the microstructure of the concrete nearest to the surface. The viability of indirectly assessing the abrasion resistance was investigated using three non-destructive techniques - Ultrasonic Pulse Velocity, Schmidt Rebound Hardness, and the Initial Surface Absorption Test. The Initial Surface Absorption was found to be most sensitive to factors which were shown to have influenced the abrasion resistance of concrete. An extensive field investigation was also undertaken. The results were used to compare site and laboratorypractices, and the performance in the accelerated abrasion test with the service wear. From this study, criteria were developed for assessing the quality of concrete floor slabs in terms of abrasion resistance.
Resumo:
Full text: With the rapid development of the aerospace industry, manufacturing technologies have to continuously develop and adjust themselves to ever-growing demands coming from more complex component designs and the use of highly engineered materials. Today there is an increased number of manufacturers contributing to the realization of final products, i.e. avionics, so it is easy to perceive the truly globalized dimension of the aerospace manufacturing business. With this comes the demand for further engineering developments on which the academic/industrial research institutes need to deliver solutions to real aerospace manufacturing problems. This is a challenging task since aerospace manufacturing technologies have to cover a wide range of materials (from composites to advanced Ni/Ti alloys), processes (from forging to non-traditional machining and assembly), and parts’ dimensions/batch sizes (from airframes to turbine blades). In this wide context, this Special Issue includes high quality theoretical and experimental scientific contributions on the following topics related to the aerospace manufacturing technology: (a) machining of advance aerospace alloys; (b) abrasive processes applied to aerospace components; (c) surface treatments to enhance fatigue performance of aerospace components; (d) joining and assembly of aerospace components; (e) laser machining of aerospace alloys; (f) automated/supervised manufacture of aerospace components; (g) quality supervision of aerospace manufacturing routes. The breadth of topics in this Special Issue is perhaps indicative of the complexity and challenges that the research related to aerospace manufacturing technology can offer. We hope that this issue will act as a catalyst for the development of further research, academic and industrial interactions, and publications related to aerospace manufacturing technologies for the benefit of the academic and industrial research communities.
Resumo:
Advances in biomaterials have enabled medical practitioners to replace diseased body parts or to assist in the healing process. In situations where a permanent biomaterial implant is used for a temporary application, additional surgeries are required to remove these implants once the healing process is complete, which increases medical costs and patient morbidity. Bio-absorbable materials dissolve and are metabolized by the body after the healing process is complete thereby negating additional surgeries for removal of implants. Magnesium alloys as novel bio-absorbable biomaterials, have attracted great attention recently because of their good mechanical properties, biocompatibility and corrosion rate in physiological environments. However, usage of Mg as biodegradable implant has been limited by its poor corrosion resistance in the physiological solutions. An optimal biodegradable implant must initially have slow degradation to ensure total mechanical integrity then degrade over time as the tissue heals. The current research focuses on surface modification of Mg alloy (MZC) by surface treatment and polymer coating in an effort to enhance the corrosion rate and biocompatibility. It is envisaged that the results obtained from this investigation would provide the academic community with insights for the utilization of bio-absorbable implants particularly for patients suffering from atherosclerosis. The alloying elements used in this study are zinc and calcium both of which are essential minerals in the human metabolic and healing processes. A hydrophobic biodegradable co-polymer, polyglycolic-co-caprolactone (PGCL), was used to coat the surface treated MZC to retard the initial degradation rate. Two surface treatments were selected: (a) acid etching and (b) anodization to produce different surface morphologies, roughness, surface energy, chemistry and hydrophobicity that are pivotal for PGCL adhesion onto the MZC. Additionally, analyses of biodegradation, biocompatibility, and mechanical integrity were performed in order to investigate the optimum surface modification process, suitable for biomaterial implants. The study concluded that anodization created better adhesion between the MZC and PGCL coating. Furthermore, PGCL coated anodized MZC exhibited lower corrosion rate, good mechanical integrity, and better biocompatibility as compared with acid etched.