922 resultados para Solar water heaters
Resumo:
With advancements in the development of visible light responsive catalysts for H2 production frequently being reported, photocatalytic water splitting has become an attractive method as a potential ‘solar fuel generator’. The development of novel photo reactors which can enhance the potential of such catalyst, however, is rarely reported. This is particularly important as many reactor configurations are mass transport limited, which in term limits the efficiency of more effective photocatalysts in larger scale applications. This paper describes the performance of a novel fluidised photo reactor for the production of H2 over two catalysts under UV-Visible light and natural solar illumination. Catalysts Pt-C3N4 and NaTaO3.La were dispersed in the reactor and the rate of H2 was determined by GC-TCD analysis of the gas headspace. The unit was an annular reactor constructed from stainless steel 316 and quartz glass with a propeller located in the base to control fluidisation of powder catalysts. Reactor properties such as propeller rotational speed were found to enhance the photo activity of the system through the elimination of mass transport limitations and increasing light penetration. The optimum conditions for H2 evolution were found to be a propeller rotational speed of 1035 rpm and 144 W of UV-Visible irradiation, which produced a rate of 89 µmol h-1 g-1 over Pt-C3N4. Solar irradiation was provided by the George Ellery Hale Solar Telescope, located at the California Institute of Technology.
Resumo:
Photodegradation is considered to be one of the most important processes of elimination of pharmaceutical drugs from natural water matrices. The high consumption and discharge of these substances, in particular antidepressants, to the aquatic environment supports the need to study degradation processes. This dissertation aimed at studying the direct and indirect photodegradation of sertraline, an antidepressant known for its persistence in the environment, and the evaluation of the influence of environmentally relevant factors in its photodegradation. The photodegradation experiments were developed under simulated solar light and the irradiation times converted to summer sunny days (SSD), an equivalent time in natural environmental conditions. The direct photodegradation was evaluated in solutions of sertraline prepared in ultrapure water and the indirect photodegradation was studied through the addition of photosensitizers (humic substances, Fe(III), nitrates and oxygen). Further irradiation studies were perfomed in aqueous samples collected from two wastewater treatment plants, Vouga river and Ria de Aveiro. The samples were chemically characterized (dissolved organic carbon, nitrates and nitrites and iron determination and UV/Vis spectroscopy). The quantification of sertraline was done by HPLC-UV and photoproducts from direct photodegradation were identified by electrospray mass spectrometry. An observed direct photodegradation rate of sertraline of 0.0062 h-1 was determined, corresponding to a half-life time of 111 h (equivalent to 29 SSD). A significant influence of photosensitizers was observed, the best results being achieved in irradiations of sertraline with humic acids, obtaining a half-life time of 12 h. This was attributed to the hydrophobicity of this substance and higher absortivity in the UV/Vis wavelength, which promote processes of indirect photodegradation. The degradation of sertraline in natural samples was also enhanced comparatively to the direct photodegradation, achieving half-life times between 10 and 25h; the best results were achieved in samples from the primary treatment of a wastewater treatment plant and Ria de Aveiro, with half-life times of 10 and 16 h, respectively. A total of six photoproducts formed during the direct photodegradation of sertraline were identified, three of which were not yet identified in the literature. The main factors contributing to the degradation of sertraline were analysed but this was not fully accomplished, requiring further studies of the composition of the natural matrices and the combined influence of distinct photosensitizers during the irradiation. Nevertheless, it was concluded that the photodegradation of sertraline is greatly influenced by indirect photodegradation processes, promoted by the presence of photosensitizers.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Estudo de uma bomba de calor de expansão direta assistida por energia solar para a preparação de AQS
Resumo:
Este estudo consiste na caracterização da eficiência energética de uma bomba de calor de expansão direta que utiliza a energia solar como fonte térmica. De uma forma geral, teve-se a obrigação de procurar cada vez mais recursos renováveis e neste sentido a bomba de calor de expansão direta tem um papel importante no aquecimento de águas quentes sanitárias (AQS). Como ponto de partida, foi realizada uma descrição detalhada sobre todos os equipamentos da bomba de calor e elaborado um desenho técnico que identifica todos os componentes. No laboratório (casa inteligente) realizaram-se vários ensaios a fim de interpretar com rigor os resultados obtidos do desempenho da bomba de calor (COP) e do fator médio de desempenho sazonal (SPF). No início, realizaram-se ensaios para determinar as perdas estáticas do sistema termodinâmico, de seguida foram elaborados ensaios segundo a norma EN 16147 e por fim, ensaios de acordo com o perfil de utilização de AQS definido. No estudo experimental do COP, obteve-se uma elevada eficiência energética com um valor médio de 4,12. O COP aumenta para valores médios de 5 quando a temperatura de água no termoacumulador desce para 35ºC. Verificou-se que durante o período diurno o COP aumenta aproximadamente de 10% relativamente ao período noturno. A potência elétrica é mais elevada (450W) quando a água no termoacumulador está perto da temperatura desejável (55ºC), originando um esforço maior da bomba de calor. No estudo experimental do SPF, verificou-se que nos ensaios segundo a norma EN16147 os valores obtidos variaram entre 1,39 e 1,50 (Classe “B”). No estudo realizado de acordo com o perfil de utilização de AQS definido pelo utilizador, o SPF é superior em 12% relativamente ao obtido segundo os ensaios realizados de acordo a norma EN16147. Verificou-se que o aumento da temperatura do ar exterior implica um aumento do SPF (cerca de 2% a 5%), enquanto a energia solar não influência nos resultados.
Resumo:
This study investigated the enhancement of solar disinfection using custom-made batch reactors with reflective (foil-backed) or absorptive (black-backed) rear surfaces, under a range of weather conditions in India. Plate counts of Escherichia coli ATCC11775 were made under aerobic conditions and under conditions where reactive oxygen species (ROS) were neutralised, i.e. in growth medium supplemented with 0.05% w/v sodium pyruvate plus incubation under anaerobic conditions. While the addition of either an absorptive or a reflective backing enhanced reactor performance under strong sunlight, the reflective reactor was the only system to show consistent enhancement under low sunlight, where the process was slowest. Counts performed under ROS-neutralised conditions were slightly higher than those in air, indicating that a fraction of the cells become sub-lethally injured during exposure to sunlight to the extent that they were unable to grow aerobically. However, the influence of this phenomenon on the dynamics of inactivation was relatively small
Resumo:
The water quality and primary productivity of Valanthakad backwater (9° 55 10. 24 N latitude and 76° 20 01. 23 E longitude) was monitored from June to November 2007. Significant spatial and temporal variations in temperature, transparency, salinity, pH, dissolved oxygen, sulphides, carbon dioxide, alkalinity, biochemical oxygen demand, phosphatephosphorus, nitrate-nitrogen, nitrite-nitrogen as well as primary productivity could be observed from the study. Transparency was low (53.75 cm to 159 cm) during the active monsoon months when the intensity of solar radiation was minimum, which together with the run off from the land resulted in turbid waters in the study sites. The salinity in both the stations was low (0.10 ‰ to 4.69 ‰) except in August and November 2007. The presence of total sulphide (0.08 mg/ l to 1.84 mg/ l) and higher carbon dioxide (3 mg/ l to 17 mg/ l) could be due to hospital discharges and decaying slaughter house wastes in Station 1 and also from the mangrove vegetation in Station 2. Nitrate-nitrogen and phosphate-phosphorus depicted higher values and pronounced variations in the monsoon season. Maximum net primary production was seen in November (0.87 gC/ m3/ day) and was reported nil in September. The chlorophyll pigments showed higher values in July, August and November with a negative correlation with phosphate-phosphorus and nitrite-nitrogen. The study indicated that the water quality and productivity of Valanthakad backwater is impacted and is the first report from the region
Resumo:
Three different drying methods, a forced convection double-pass solar drier (DPSD), typical cabinet type natural convection solar drier (CD) and traditional open-sun drying (OSD) were used for draying of bamboo shoots in central Vietnam. During drying the operational parameters such as drying temperature, relative humidity, air velocity, insolation and water evaporation have been recorded hourly. The mean drying temperatures and relative humidity in the drying chamber were 55.2°C, 23.7%; 47.5°C, 37,6%; 36.2°C, 47.8% in DPSD, CD and OSD, respectively. The mean global radiation during all experimental runs was 670 Wm^−2. The result also shows that fastest drying process was occurred in DPSD where the falling-rate period was achieved after 7 hours, in change to OSD where it took 16 hours. The overall drying efficiency was 23.11%, 15.83% and 9.73% in case of DPSD, CD and OSD, respectively. Although the construction cost of DPSD was significantly higher than in CD, the drying costs per one kilogram of bamboo shoots were by 42.8% lower in case of DPSD as compared to CD. Double-pass solar drier was found to be technically and economically suitable for drying of bamboo shoots under the specific conditions in central Vietnam and in all cases, the use of this drier led to considerable reduction in drying time in comparison to traditional open-sun drying.
Resumo:
Projecte de la instal•lació de calefacció i agua calenta utilitzant energia solar tèrmica i ajudant-se d’ una caldera de biomassa en un edifici en construcció situat a Colera (Alt Empordà). Es tracta d’un bloc de quatre vivendes distribuïdes en dues plantes, soterrani i terrassa superior
Resumo:
En el present projecte final de carrera s’han dissenyat i pressupostat les instal·lacions de fontaneria, energia solar i gas natural per abastir d’aigua les dependències d’un hotel. L’hotel es troba situat a municipi de Platja d’Aro, a la província de Girona. La seva categoria és de quatre estrelles i això comporta un nivell alt de qualitat en els serveis oferts, en aquest cas el subministrament d’aigua freda i aigua calenta sanitària (ACS) als seus clients
Resumo:
Aquesta instal•lació solar tèrmica s’ha dissenyat per cobrir part de les necessitats energètiques d’un edifici que consta de 10 habitatges de protecció oficial construïts en 2 plantes a la localitat de Quart. L’objectiu d’aquest projecte és arribar a una cobertura solar aproximada del 50% de les necessitats d’ aigua calenta sanitària (ACS) i climatització
Resumo:
Applicaciò d'un model de hydrodinàmica i de qualitat de l'aigua als embassaments de Sau i Boadella
Resumo:
Abstract Foggy air and clear air have appreciably different electrical conductivities. The conductivity gradient at horizontal droplet boundaries causes droplet charging, as a result of vertical current flow in the global atmospheric electrical circuit. The charging is poorly known, as both the current flow through atmospheric water droplet layers and the air conductivity are poorly characterised experimentally. Surface measurements during three days of continuous fog using new instrument techniques show that a shallow (of order 100 m deep) fog layer still permits the vertical conduction current to pass. Further, the conductivity in the fog is estimated to be approximately 20% lower than in clear air. Assuming a fog transition thickness of one metre, this implies a vertical conductivity gradient of order 10 fS m−2 at the boundary. The actual vertical conductivity gradient at a cloud boundary would probably be greater, due to the presence of larger droplets in clouds compared to fog, and cleaner, more conductive clear air aloft.
Resumo:
Laser beams emitted from the Geoscience Laser Altimeter System (GLAS), as well as other spaceborne laser instruments, can only penetrate clouds to a limit of a few optical depths. As a result, only optical depths of thinner clouds (< about 3 for GLAS) are retrieved from the reflected lidar signal. This paper presents a comprehensive study of possible retrievals of optical depth of thick clouds using solar background light and treating GLAS as a solar radiometer. To do so one must first calibrate the reflected solar radiation received by the photon-counting detectors of the GLAS 532-nm channel, the primary channel for atmospheric products. Solar background radiation is regarded as a noise to be subtracted in the retrieval process of the lidar products. However, once calibrated, it becomes a signal that can be used in studying the properties of optically thick clouds. In this paper, three calibration methods are presented: (i) calibration with coincident airborne and GLAS observations, (ii) calibration with coincident Geostationary Opera- tional Environmental Satellite (GOES) and GLAS observations of deep convective clouds, and (iii) cali- bration from first principles using optical depth of thin water clouds over ocean retrieved by GLAS active remote sensing. Results from the three methods agree well with each other. Cloud optical depth (COD) is retrieved from the calibrated solar background signal using a one-channel retrieval. Comparison with COD retrieved from GOES during GLAS overpasses shows that the average difference between the two retriev- als is 24%. As an example, the COD values retrieved from GLAS solar background are illustrated for a marine stratocumulus cloud field that is too thick to be penetrated by the GLAS laser. Based on this study, optical depths for thick clouds will be provided as a supplementary product to the existing operational GLAS cloud products in future GLAS data releases.
Resumo:
In most near-infrared atmospheric windows, absorption of solar radiation is dominated by the water vapor self-continuum and yet there is a paucity of measurements in these windows. We report new laboratory measurements of the self-continuum absorption at temperatures between 293 and 472 K and pressures from 0.015 to 5 atm in four near-infrared windows between 1 and 4 m (10000-2500 cm-1); the measurements are made over a wider range of wavenumber, temperatures and pressures than any previous measurements. They show that the self-continuum in these windows is typically one order of magnitude stronger than given in representations of the continuum widely used in climate and weather prediction models. These results are also not consistent with current theories attributing the self continuum within windows to the far-wings of strong spectral lines in the nearby water vapor absorption bands; we suggest that they are more consistent with water dimers being the major contributor to the continuum. The calculated global-average clear-sky atmospheric absorption of solar radiation is increased by 0.75 W/m2 (which is about 1% of the total clear-sky absorption) by using these new measurements as compared to calculations with the MT_CKD-2.5 self-continuum model.