584 resultados para Soft contact lens


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to describe the outcome of patients with filtering blebs who were fit with contact lenses. Methods: We retrospectively studied patients with filtering blebs secondary to glaucoma or cataract surgery who were fit with contact lenses. Eight eyes from seven patients were identified. Results: Five patients (six eyes) were fit with gas permeable contact lenses and two patients (two eyes) were fit with soft contact lenses. Successful fits were achieved in all patients. No complications were observed after a mean follow-up of 64.6±28.5 months. Conclusions: No significant complications were recorded in our series of patients with filtering blebs who were fit with contact lenses. We think that when indications for fitting contact lenses are justified, patients with filtering blebs are acceptable candidates for contact lens use. However, adequate selection of cases, careful contact lens fitting, patient education, and close follow-up are necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Most published surface wettability data are based on hydrated materials and are dominated by the air-water interface. Water soluble species with hydrophobic domains (such as surfactants) interact directly with the hydrophobic domains in the lens polymer. Characterisation of relative polar and non-polar fractions of the dehydrated material provides an additional approach to surface analysis. Method: Probe liquids (water and diiodomethane) were used to characterise polar and dispersive components of surface energies of dehydrated lenses using the method of Owens and Wendt. A range of conventional and silicone hydrogel soft lenses was studied. The polar fraction (i.e. polar/total) of surface energy was used as a basis for the study of the structural effects that influence surfactant persistence on the lens surface. Results: When plotted against water content of the hydrated lens, polar fraction of surface energy (PFSE) values of the dehydrated lenses fell into two rectilinear bands. One of these bands covered PFSE values ranging from 0.4 to 0.8 and contained only conventional hydrogels, with two notable additions: the plasma coated silicone hydrogels lotrafilcon A and B. The second band covered PFSE values ranging from 0.04 to 0.28 and contained only silicone hydrogels. Significantly, the silicone hydrogel lenses with lowest PFSE values (p<0.15) are found to be prone to lipid deposition duringwear. Additionally, more hydrophobic surfactants were found to be more persistent on lenses with lower PFSE values. Conclusions: Measurement of polar fraction of surface energy provides an importantmechanistic insight into surface interactions of silicone hydrogels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives and Methods: Contact angle, as a representative measure of surface wettability, is often employed to interpret contact lens surface properties. The literature is often contradictory and can lead to confusion. This literature review is part of a series regarding the analysis of hydrogel contact lenses using contact angle techniques. Here we present an overview of contact angle terminology, methodology, and analysis. Having discussed this background material, subsequent parts of the series will discuss the analysis of contact lens contact angles and evaluate differences in published laboratory results. Results: The concepts of contact angle, wettability and wetting are presented as an introduction. Contact angle hysteresis is outlined and highlights the advantages in using dynamic analytical techniques over static methods. The surface free energy of a material illustrates how contact angle analysis is capable of providing supplementary surface characterization. Although single values are able to distinguish individual material differences, surface free energy and dynamic methods provide an improved understanding of material behavior. The frequently used sessile drop, captive bubble, and Wilhelmy plate techniques are discussed. Their use as both dynamic and static methods, along with the advantages and disadvantages of each technique, is explained. Conclusions: No single contact angle technique fully characterizes the wettability of a material surface, and the application of complimenting methods allows increased characterization. At present, there is not an ISO standard method designed for soft materials. It is important that each contact angle technique has a standard protocol, as small protocol differences between laboratories often contribute to a variety of published data that are not easily comparable. © 2013 Contact Lens Association of Ophthalmologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess visual performance and ocular aberrations in keratoconic patients using toric soft contact lenses (SCL), rigid-gas-permeable (RGP) contact lenses and spectacle lens correction. Methods: Twenty-two keratoconus patients (16 RGP lens wearers and six spectacle wearers) were fitted with toric SCL. Ocular aberrations were measured with and without the patient's habitual RGP lenses and with the SCL in place. In the spectacle wearers, aberrations were measured with and without the SCL. Visual performance (high- and low-contrast visual acuity) was evaluated with the patient's habitual correction and with the SCL. Results: In the RGP lens wearers both the habitual lenses and the toric SCL significantly reduced coma, trefoil, 3rd-order, 4th-order cylinder and higher-order root-mean-square (RMS) aberrations (p≤0.015). In the spectacle wearers the toric SCL significantly reduced coma, 3rd-order and higher-order RMS aberrations (p≤0.01). The patients' habitual RGP lenses gave better low-contrast acuity (p≤0.006) compared to the toric SCL; however, no significant difference was found between lens types for high-contrast acuity (p=0.10). In the spectacle wearers no significant differences in visual performance measurements were found between the patients' spectacles and the toric SCL (p≥0.06). Conclusion: The results show that RGP lenses provided superior visual performances and greater reduction of 3rd-order aberrations compared to toric SCL in this group of keratoconic patients. In the spectacle-wearing group, visual performance with the toric SCL was found to be comparable to that measured with spectacles. Nevertheless, with the exception of spherical aberration, the toric SCL were successful in significantly reducing uncorrected higher-order aberrations. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: the aim of this pilot study was to test whether retinitis pigmentosa patients would benefit from filter contact lenses as an effective optical aid against glare and photophobia. Methods: fifteen subjects with retinitis pigmentosa were enrolled in this study. All of them were evaluated with filter soft contact lenses (MaxSight), filter glasses (CPF 527) and without filters (control). All patients were assessed for the three aid conditions by means of best corrected visual acuity (BCVA), contrast sensitivity (without glare and with central and peripheral glare)(CSV-1000) and a specific subjective questionnaire about quality of vision. Results: BCVA was slightly better with filters than without filter but the differences were not statistically significant. Contrast sensitivity without glare improved significantly with the contact lenses (p<0.05). The central glare had significant differences for the frequencies of 3 cpd and 18 cpd between the contact lens filter and the control group (p=0.021 and p=0.044, respectively). For the peripheral glare contrast sensitivity improved with contact lens versus control group for highest frequencies, 12 and 18 cpd (p<0.001 and p=0.045, respectively). According to the questionnaire the contact lens filter gave them more visual comfort than the glasses filter under the scenarios of indoors glare, outdoors activities and indoors comfort. Conclusion: the filter contact lenses seem to be a good option to improve the quality of vision of patients with retinitis pigmentosa.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The cornea is known to be susceptible to forces exerted by eyelids. There have been previous attempts to quantify eyelid pressure but the reliability of the results is unclear. The purpose of this study was to develop a technique using piezoresistive pressure sensors to measure upper eyelid pressure on the cornea. Methods: The technique was based on the use of thin (0.18 mm) tactile piezoresistive pressure sensors, which generate a signal related to the applied pressure. A range of factors that influence the response of this pressure sensor were investigated along with the optimal method of placing the sensor in the eye. Results: Curvature of the pressure sensor was found to impart force, so the sensor needed to remain flat during measurements. A large rigid contact lens was designed to have a flat region to which the sensor was attached. To stabilise the contact lens during measurement, an apparatus was designed to hold and position the sensor and contact lens combination on the eye. A calibration system was designed to apply even pressure to the sensor when attached to the contact lens, so the raw digital output could be converted to actual pressure units. Conclusions: Several novel procedures were developed to use tactile sensors to measure eyelid pressure. The quantification of eyelid pressure has a number of applications including eyelid reconstructive surgery and the design of soft and rigid contact lenses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Presbyopia affects individuals from the age of 45 years onwards, resulting in difficulty in accurately focusing on near objects. There are many optical corrections available including spectacles or contact lenses that are designed to enable presbyopes to see clearly at both far and near distances. However, presbyopic vision corrections also disturb aspects of visual function under certain circumstances. The impact of these changes on activities of daily living such as driving are, however, poorly understood. Therefore, the aim of this study was to determine which aspects of driving performance might be affected by wearing different types of presbyopic vision corrections. In order to achieve this aim, three experiments were undertaken. The first experiment involved administration of a questionnaire to compare the subjective driving difficulties experienced when wearing a range of common presbyopic contact lens and spectacle corrections. The questionnaire was developed and piloted, and included a series of items regarding difficulties experienced while driving under day and night-time conditions. Two hundred and fifty five presbyopic patients responded to the questionnaire and were categorised into five groups, including those wearing no vision correction for driving (n = 50), bifocal spectacles (BIF, n = 54), progressive addition lenses spectacles (PAL, n = 50), monovision (MV, n = 53) and multifocal contact lenses (MTF CL, n = 48). Overall, ratings of satisfaction during daytime driving were relatively high for all correction types. However, MV and MTF CL wearers were significantly less satisfied with aspects of their vision during night-time than daytime driving, particularly with regard to disturbances from glare and haloes. Progressive addition lens wearers noticed more distortion of peripheral vision, while BIF wearers reported more difficulties with tasks requiring changes in focus and those who wore no vision correction for driving reported problems with intermediate and near tasks. Overall, the mean level of satisfaction for daytime driving was quite high for all of the groups (over 80%), with the BIF wearers being the least satisfied with their vision for driving. Conversely, at night, MTF CL wearers expressed the least satisfaction. Research into eye and head movements has become increasingly of interest in driving research as it provides a means of understanding how the driver responds to visual stimuli in traffic. Previous studies have found that wearing PAL can affect eye and head movement performance resulting in slower eye movement velocities and longer times to stabilize the gaze for fixation. These changes in eye and head movement patterns may have implications for driving safety, given that the visual tasks for driving include a range of dynamic search tasks. Therefore, the second study was designed to investigate the influence of different presbyopic corrections on driving-related eye and head movements under standardized laboratory-based conditions. Twenty presbyopes (mean age: 56.1 ± 5.7 years) who had no experience of wearing presbyopic vision corrections, apart from single vision reading spectacles, were recruited. Each participant wore five different types of vision correction: single vision distance lenses (SV), PAL, BIF, MV and MTF CL. For each visual condition, participants were required to view videotape recordings of traffic scenes, track a reference vehicle and identify a series of peripherally presented targets while their eye and head movements were recorded using the faceLAB® eye and head tracking system. Digital numerical display panels were also included as near visual stimuli (simulating the visual displays of a vehicle speedometer and radio). The results demonstrated that the path length of eye movements while viewing and responding to driving-related traffic scenes was significantly longer when wearing BIF and PAL than MV and MTF CL. The path length of head movements was greater with SV, BIF and PAL than MV and MTF CL. Target recognition was less accurate when the near stimulus was located at eccentricities inferiorly and to the left, rather than directly below the primary position of gaze, regardless of vision correction type. The third experiment aimed to investigate the real world driving performance of presbyopes while wearing different vision corrections measured on a closed-road circuit at night-time. Eye movements were recorded using the ASL Mobile Eye, eye tracking system (as the faceLAB® system proved to be impractical for use outside of the laboratory). Eleven participants (mean age: 57.25 ± 5.78 years) were fitted with four types of prescribed vision corrections (SV, PAL, MV and MTF CL). The measures of driving performance on the closed-road circuit included distance to sign recognition, near target recognition, peripheral light-emitting-diode (LED) recognition, low contrast road hazards recognition and avoidance, recognition of all the road signs, time to complete the course, and driving behaviours such as braking, accelerating, and cornering. The results demonstrated that driving performance at night was most affected by MTF CL compared to PAL, resulting in shorter distances to read signs, slower driving speeds, and longer times spent fixating road signs. Monovision resulted in worse performance in the task of distance to read a signs compared to SV and PAL. The SV condition resulted in significantly more errors made in interpreting information from in-vehicle devices, despite spending longer time fixating on these devices. Progressive addition lenses were ranked as the most preferred vision correction, while MTF CL were the least preferred vision correction for night-time driving. This thesis addressed the research question of how presbyopic vision corrections affect driving performance and the results of the three experiments demonstrated that the different types of presbyopic vision corrections (e.g. BIF, PAL, MV and MTF CL) can affect driving performance in different ways. Distance-related driving tasks showed reduced performance with MV and MTF CL, while tasks which involved viewing in-vehicle devices were significantly hampered by wearing SV corrections. Wearing spectacles such as SV, BIF and PAL induced greater eye and head movements in the simulated driving condition, however this did not directly translate to impaired performance on the closed- road circuit tasks. These findings are important for understanding the influence of presbyopic vision corrections on vision under real world driving conditions. They will also assist the eye care practitioner to understand and convey to patients the potential driving difficulties associated with wearing certain types of presbyopic vision corrections and accordingly to support them in the process of matching patients to optical corrections which meet their visual needs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: One strategy to minimize bacteria-associated adverse responses such as microbial keratitis, contact lens–induced acute red eye (CLARE), and contact lens induced peripheral ulcers (CLPUs) that occur with contact lens wear is the development of an antimicrobial or antiadhesive contact lens. Cationic peptides represent a novel approach for the development of antimicrobial lenses.---------- Methods: A novel cationic peptide, melimine, was covalently incorporated into silicone hydrogel lenses. Confirmation tests to determine the presence of peptide and anti-microbial activity were performed. Cationic lenses were then tested for their ability to prevent CLPU in the Staphylococcus aureus rabbit model and CLARE in the Pseudomonas aeruginosa guinea pig model. ---------- Results: In the rabbit model of CLPU, melimine-coated lenses resulted in significant reductions in ocular symptom scores and in the extent of corneal infiltration (P < 0.05). Evaluation of the performance of melimine lenses in the CLARE model showed significant improvement in all ocular response parameters measured, including the percentage of eyes with corneal infiltrates, compared with those observed in the eyes fitted with the control lens (P ≤ 0.05). ---------- Conclusions: Cationic coating of contact lenses with the peptide melimine may represent a novel method of prevention of bacterial growth on contact lenses and consequently result in reduction of the incidence and severity of adverse responses due to Gram-positive and -negative bacteria during lens wear.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A healthy human would be expected to show periodic blinks, making a brief closure of the eyelids. Most blinks are spontaneous, occurring regularly with no external stimulus. However a reflex blink can occur in response to external stimuli such as a bright light, a sudden loud noise, or an object approaching toward the eyes. A voluntary or forced blink is another type of blink in which the person deliberately closes the eyes and the lower eyelid raises to meet the upper eyelid. A complete blink, in which the upper eyelid touches the lower eyelid, contributes to the health of ocular surface by providing a fresh layer of tears as well as maintaining optical integrity by providing a smooth tear film over the cornea. The rate of blinking and its completeness vary depending on the task undertaken during blink assessment, the direction of gaze, the emotional state of the subjects and the method under which the blink was measured. It is also well known that wearing contact lenses (both rigid and soft lenses) can induce significant changes in blink rate and completeness. It is been established that efficient blinking plays an important role in ocular surface health during contact lens wear and for improving contact lens performance and comfort. Inefficient blinking during contact lens wear may be related to a low blink rate or incomplete blinking and can often be a reason for dry eye symptoms or ocular surface staining. It has previously been shown that upward gaze can affect blink rate, causing it to become faster. In the first experiment, it was decided to expand on previous studies in this area by examining the effect of various gaze directions (i.e. upward gaze, primary gaze, downward gaze and lateral gaze) as well as head angle (recumbent position) on normal subjects’ blink rate and completeness through the use of filming with a high-speed camera. The results of this experiment showed that as the open palpebral aperture (and exposed ocular surface area) increased from downward gaze to upward gaze, the number of blinks significantly increased (p<0.04). Also, the size of closed palpebral aperture significantly increased from downward gaze to upward gaze (p<0.005). A weak positive correlation (R² = 0.18) between the blink rate and ocular surface area was found in this study. Also, it was found that the subjects showed 81% complete blinks, 19% incomplete blinks and 2% of twitch blinks in primary gaze, consistent with previous studies. The difference in the percentage of incomplete blinks between upward gaze and downward gaze was significant (p<0.004), showing more incomplete blinks in upward gaze. The findings of this experiment suggest that while blink rate becomes slower in downward gaze, the completeness of blinking is typically better, thereby potentially reducing the risk of tear instability. On the other hand, in upward gaze while the completeness of blinking becomes worse, this is potentially offset by increased blink frequency. In addition, blink rate and completeness were not affected by lateral gaze or head angle, possibly because these conditions have similar size of the open palpebral aperture compared with primary gaze. In the second experiment, an investigation into the changes in blink rate and completeness was carried out in primary gaze and downward gaze with soft and rigid contact lenses in unadapted wearers. Not surprisingly, rigid lens wear caused a significant increase in the blink rate in both primary (p<0.001) and downward gaze (p<0.02). After fitting rigid contact lenses, the closed palpebral aperture (blink completeness) did not show any changes but the open palpebral aperture showed a significant narrowing (p<0.04). This might occur from the subjects’ attempt to avoid interaction between the upper eyelid and the edge of the lens to minimize discomfort. After applying topical anaesthetic eye drops in the eye fitted with rigid lenses, the increased blink rate dropped to values similar to that before lens insertion and the open palpebral aperture returned to baseline values, suggesting that corneal and/or lid margin sensitivity was mediating the increased blink rate and narrowed palpebral aperture. We also investigated the changes in the blink rate and completeness with soft contact lenses including a soft sphere, double slab-off toric design and periballast toric design. Soft contact lenses did not cause any significant changes in the blink rate, closed palpebral aperture, open palpebral aperture and the percentage of incomplete blinks in either primary gaze or downward gaze. After applying anaesthetic eye drops, the blink rate reduced in both primary gaze and downward gaze, however this difference was not statistically significant. The size of the closed palpebral aperture and open palpebral aperture did not show any significant changes after applying anaesthetic eye drops. However it should be noted that the effects of rigid and soft contact lenses that we observed in these studies were only the immediate reaction to contact lenses and in the longer term, it is likely that these responses will vary as the eye adapts to the presence of the lenses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To assess the accuracy of intraocular pressure(IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) and silicone hydrogel (senofilcon A) contact lenses (CLs) of different powers. Methods: The experimental group comprised 36 subjects (19 male, 17 female). IOP measurements were undertaken on the subject’s right eyes in random order using a rebound tonometer (ICare). The CLs had powers of +2.00D, −2.00D and−6.00D. Six measurements were taken over each contact lens and also before and after the CLs had been worn. Results: A good correlation was found between IOP measurements with and without CLs (all r≥0.80; p < 0.05). Bland Altman plots did not show any significant trend in the difference in IOP readings with and without CLs as a function of IOP value. A two-way ANOVA revealed a significant effect of material and power (p < 0.01) but no interaction. All the comparisons between the measurements without CLs and with hydrogel CLs were significant (p < 0.01). The comparisons with silicone hydrogel CLs were not significant. Conclusions: Rebound tonometry can be reliably performed over silicone hydrogel CLs. With hydrogel CLs, the measurements were lower than those without CLs. However, despite the fact that these differences were statistically significant, their clinical significance was minimal.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE To investigate the utility of using non-contact laser-scanning confocal microscopy (NC-LSCM), compared with the more conventional contact laser-scanning confocal microscopy (C-LSCM), for examining corneal substructures in vivo. METHODS An attempt was made to capture representative images from the tear film and all layers of the cornea of a healthy, 35 year old female, using both NC-LSCM and C-LSCM, on separate days. RESULTS Using NC-LSCM, good quality images were obtained of the tear film, stroma, and a section of endothelium, but the corneal depth of the images of these various substructures could not be ascertained. Using C-LSCM, good quality, full-field images were obtained of the epithelium, subbasal nerve plexus, stroma, and endothelium, and the corneal depth of each of the captured images could be ascertained. CONCLUSIONS NC-LSCM may find general use for clinical examination of the tear film, stroma and endothelium, with the caveat that the depth of stromal images cannot be determined when using this technique. This technique also facilitates image capture of oblique sections of multiple corneal layers. The inability to clearly and consistently image thin corneal substructures - such as the tear film, subbasal nerve plexus and endothelium - is a key limitation of NC-LSCM.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

While vital staining remains a cornerstone in the diagnosis of ocular disease and contact lens complications, there are many misconceptions regarding the properties of commonly used dyes by eye-care practitioners and what is and what is not corneal staining after instillation of sodium fluorescein. Similarly, the proper use and diagnostic utility of rose Bengal and lissamine green B, the other two ophthalmic dyes commonly used for assessing ocular complications, have similarly remained unclear. Due to the limitations of vital stains for definitive diagnosis, concomitant signs and symptoms in addition to a complete patient history are required. Over the past decade, there have been many reports of a type of corneal staining—often referred to as solution-induced corneal staining (SICS)—that is observed with the use of multipurpose solutions in combination with soft lenses, more specifically silicone hydrogel lenses. Some authors believe that SICS is a sign of lens/solution incompatibility; however, new research shows that SICS may be neither a measure of lens/solution biocompatibility nor ‘true’ corneal staining, as that observed in pathological situations. A large component of SICS may be a benign phenomenon, known as preservative-associated transient hyperfluorescence (PATH). There is a lack of correlated signs and/or symptoms with SICS/PATH. Several properties of SICS/PATH, such as appearance and duration, differentiate it from pathological corneal staining. This paper reviews the properties of vital stains, their use and limitations in assessment of the ocular surface, the aetiology of corneal staining, characteristics of SICS/PATH that differentiate it from pathological corneal staining and what the SICS/PATH phenomenon means for contact lens-wearing patients.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ever since sodium fluorescein (‘fluorescein’ [FL]) was first used to investigate the ocular surface over a century ago, the term ‘staining’ has been taken to mean the presence of ocular surface fluorescence [1]. This term has not been necessarily taken to infer any particular mechanism of causation, and indeed, can be attributed to a variety of possible aetiologies [2]. In recent times, there has been considerable interest in a form of ocular surface fluorescence seen in association with the use of certain combinations of soft contact lenses and multipurpose solutions. The first clinical account of this phenomenon was reported by Jones et al. [3], which was followed by a more formal investigation by the same author in 2002 [4]. Jones et al described this appearance as a ‘classic solution-based toxicity reaction’. Subsequently, this appearance has come to be known as ‘solution-induced corneal staining’ or more recently by the acronym ‘SICS’ [5]. The term SICS is potentially problematic in that from a cell biology point of view, there is an inference that ‘staining’ means the entry of a dye into corneal epithelial cells. Morgan and Maldonado-Codina [2] noted there was no foundation of solid scientific literature underpinning our understanding of the true basic causative mechanisms of this phenomenon; since that time, further work has been published in this field [6] and [7] but questions still remain about the precise aetiology of this phenomenon...