951 resultados para Single Crossing Property Marginal Rate of Substitution IdentityDiscrete Pooling.
Resumo:
Introduction: Absorbable anchors are frequently used in shoulder surgery. Mechanisms of absorption induce a local inflammatory reaction. It is not clear if this process may disturb healing of the capsule and ligaments. The purpose of the study was to compare the rate of recurrent dislocation following open shoulder stabilization when using absorbable or non-absorbable suture anchors. Methods: Between 1999 and 2003, 83 open Bankart repairs were performed by the same surgeon. All patients had recurrent traumatic anterior shoulder instability. All had preoperative arthro-MRI or arthro-CT which did not reveal any significant bony Bankart lesion or rotatorcuff tear. Thirty-four patients were treated with absorbable anchors (Panalok®) and sutures (Panacryl®) and 49 with non-absorbable anchors (Mitek GII®) and sutures (Ethibond®). The same surgical technique and rehabilitation protocol were used. The incidence of sports ability and recurrent instability were recorded. We defined instability as true dislocation. Results: Five patients on 34 were lost to follow-up in the absorbable group and 7 on 49 in the non-absorbable group. The mean age of absorbable group was 25 years (range, 17-39 years). At a mean follow-up of 66 months (range, 54-76 months), 86% could resume sports activity. Five patients on 29 (17%) reported recurrent instability and two did need revision surgery. The mean age in non-absorbable group was 28 year (range, 18-47 years). At a mean follow-up of 78 months (range, 49-82 months), 93% could resume sports activity. Three patients on 42 (7%) reported recurrent instability and one did need revision surgery. Conclusion: This clinical study showed a clear tendency to a higher recurrence rate of dislocation when using absorbable suture anchors (17% in absorbable vs 7% in non-absorbable group). It is known that Panacryl® may be responsible for a major local inflammatory response. However, it is still unclear if this could be the failure etiology. Consequently, we prefer to use systematically non-absorbable sutureanchors for shoulder stabilization.
Resumo:
Abstract Objective: The objective of this retrospective study over a 5-year period was to assess the success rate of airway management by residents. Criteria of successful airway management were both the adherence to a standardized protocol of pre-hospital airway.
Resumo:
The objective of this work was to obtain prevalence estimates of cloudy vaginal mucus in artificially inseminated Holstein cows raised under intense heat, in order to assess the effect of meteorological conditions on its occurrence during estrus and to determine its effect on conception rate. In a first study, an association was established between the occurrence of cloudy vaginal mucus during estrus and the conception rate of inseminated cows (18,620 services), raised under intense heat (mean annual temperature of 22°C), at highly technified farms, in the arid region of northern Mexico. In a second study, data from these large dairy operations were used to assess the effect of meteorological conditions throughout the year on the occurrence of cloudy vaginal mucus during artificial insemination (76,899 estruses). The overall rate of estruses with cloudy vaginal mucus was 21.4% (16,470/76,899; 95% confidence interval = 21.1-21.7%). The conception rate of cows with clean vaginal mucus was higher than that of cows with abnormal mucus (30.6 vs. 22%). Prevalence of estruses with cloudy vaginal mucus was strongly dependent on high ambient temperature and markedly higher in May and June. Acceptable conception rates in high milk-yielding Holstein cows can only be obtained with cows showing clear and translucid mucus at artificial insemination.
Resumo:
The rate of leaf appearance of barley varies substantially with time of sowing. This variation has been related to both the length and the rate of change of photoperiod at the time of plant emergence. An outdoor pot experiment was conducted to test if rate of change of photoperiod directly affects phasic development and rate of leaf emergence of spring barley. Two photoperiod-sensitive cultivars (Bandulla and Galleon) were subjected to five photoperiod regimes: two constant photoperiods, of 14 and 15·5 h, and three different rates of change of photoperiod of c. 2, 9 and 13 min/day from seedling emergence to awn initiation. Photoperiod treatments significantly affected the duration from seedling emergence to awn initiation in both cultivars. Rate of change of photoperiod did not affect the rate of development towards awn initiation independently of the absolute daylength it produced. Although Bandulla had a longer duration than Galleon at any photoperiod regime, the cultivars did not vary in their sensitivity to photoperiod. When this phase was divided into the leaf initiation (LI) and spikelet initiation (SI) phases, it was evident that the sensitivity to photoperiod was not constant, being in general higher during the SI than during the LI phase. However, the magnitude of the change in sensitivity was cultivar-dependent, indicating that sensitivity to photoperiod during the different phases could be under independent genetic control. Final numbers of primordia (leaves together with maximum spikelet number) were negatively affected by increasing photoperiods, but once again, there was no evidence of any effect of the rate of change of photoperiod which was independent of the average photoperiod. Both cultivars showed similar sensitivities for final leaf number but maximum spikelet number was more sensitive to photoperiod in Galleon than in Bandulla. Highly significant linear relationships between leaf number and thermal time were found for all combinations of cultivars and photoperiod regimes (r2 > 0·98). The rate of leaf appearance (RLA) was similar for both cultivars (c. 0·0185 leaves/°Cd) and did not alter during plant development or in response to the change in photoperiod at awn initiation. The range in RLA was greater for Galleon (0·0170–0·0205 leaves/°Cd) than for Bandulla (0·0173–0·0186 leaves/°Cd). Neither of these cultivars exhibited a significant relationship between rate of leaf emergence and photoperiod or rate of change of photoperiod. The lack of significant relationships between RLA and length or rate of change of photoperiod is in contrast with previous reports using time of sowing as a main treatment.
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
Data concerning the effect of temperature on different physiological parameters of an invasive species can be a useful tool to predict its potential distribution range through the use of modelling approaches. In the case of the Argentine ant these data are too scarce and incomplete. The aim of the present study is to compile new data regarding the effect of temperature on the oviposition rate of the Argentine ant queens. We analysed the oviposition rate of queens at twelve controlled temperatures, ranging from 10ºC to 34ºC under different monogynous and polygynous conditions. The oviposition rate of the Argentine ant queens is affected by temperature in the same manner, independently of the number of queens in the nest. The optimal temperature for egg laying was 28ºC, and its upper and lower limits depended on the degree of polygyny
Resumo:
Prompt production of charmonium χ c0, χ c1 and χ c2 mesons is studied using proton-proton collisions at the LHC at a centre-of-mass energy of TeX TeV. The χ c mesons are identified through their decay to J/ψγ, with J/ψ → μ + μ − using photons that converted in the detector. A data sample, corresponding to an integrated luminosity of 1.0 fb−1 collected by the LHCb detector, is used to measure the relative prompt production rate of χ c1 and χ c2 in the rapidity range 2.0 < y < 4.5 as a function of the J/ψ transverse momentum from 3 to 20 GeV/c. First evidence for χ c0 meson production at a high-energy hadron collider is also presented.
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.
Resumo:
APROS (Advanced Process Simulation Environment) is a computer simulation program developed to simulate thermal hydraulic processes in nuclear and conventional power plants. Earlier research at VTT Technological Research Centre of Finland had found the current version of APROS to produce inaccurate simulation results for a certain case of loop seal clearing. The objective of this Master’s thesis is to find and implement an alternative method for calculating the rate of stratification in APROS, which was found to be the reason for the inaccuracies. Brief literature study was performed and a promising candidate for the new method was found. The new method was implemented into APROS and tested against experiments and simulations from two test facilities and the current version of APROS. Simulation results with the new version were partially conflicting; in some cases the new method was more accurate than the current version, in some the current method was better. Overall, the new method can be assessed as an improvement.
Resumo:
I mars 2003 certifierades en finländsk advokatbyrå av den Europeiska kommissionen som den bästa i Europa inom specialkategorin livslångt lärande. Advokatbyrån var överraskad över utnämningen emedan de inte aktivt och/eller medvetet implementerat eller utövat en livslångt lärandestrategi i sin verksamhet bland sin personal. Byrån deltog i en tävling om bästa arbetsplats i Europa ("Best workplaces in Europe 2003") utan att vara medveten om den Europeiska kommissionens special- kategorier. Emedan advokatbyrån inte medvetet implementerat en livslångt lärandestrategi bland sin personal formar aktörerna, vars uppfattning och prat denna avhandling handlar om, sina föreställningar och sitt prat om livslångt lärande efter utnämningen. Översättningsprocessen av en idé utlöses sålunda i denna studie av en extern händelse. I sin avhandling beskriver Annica Isacsson hur och varför en idé (livslångt lärande) föds (på nytt) på en institutionell nivå, hur idén reser och förändras i en process av översättning, hur idén landar i två organisationer samt hur idén om livslångt lärande uppfattas och beskrivs av lokala aktörer i två olika organisationer. Fokus i studien ligger sålunda på enskilda aktörers uppfattning om ett kontroversiellt koncept i en lokal kontext. Teoretiskt möts och sammanlänkas teori om livslångt lärande, sociokulturella teorier om lärande och teorier om organisatoriskt lärande. Isacssons avhandling visar på hur livslångt lärande inte enbart, i en organisatorisk kontext, handlar om individuell kompetensutveckling utan också om organisatoriskt lärande i vilken lärande av andra organisationsmedlemmar och organisationer ingår. Studien visar vidare på hur enskilda aktörers prat påverkas av det institutionella fältet och av den tidsanda inom vilken diskursen livslångt lärande föds, rör sig och ingår.