916 resultados para SYSTEM FAILURE ANALYSIS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Different kinds of ventilators are available to perform noninvasive ventilation (NIV) in ICUs. Which type allows the best patient-ventilator synchrony is unknown. The objective was to compare patient-ventilator synchrony during NIV between ICU, transport-both with and without the NIV algorithm engaged-and dedicated NIV ventilators. METHODS: First, a bench model simulating spontaneous breathing efforts was used to assess the respective impact of inspiratory and expiratory leaks on cycling and triggering functions in 19 ventilators. Second, a clinical study evaluated the incidence of patient-ventilator asynchronies in 15 patients during three randomized, consecutive, 20-min periods of NIV using an ICU ventilator with and without its NIV algorithm engaged and a dedicated NIV ventilator. Patient-ventilator asynchrony was assessed using flow, airway pressure, and respiratory muscles surface electromyogram recordings. RESULTS: On the bench, frequent auto-triggering and delayed cycling occurred in the presence of leaks using ICU and transport ventilators. NIV algorithms unevenly minimized these asynchronies, whereas no asynchrony was observed with the dedicated NIV ventilators in all except one. These results were reproduced during the clinical study: The asynchrony index was significantly lower with a dedicated NIV ventilator than with ICU ventilators without or with their NIV algorithm engaged (0.5% [0.4%-1.2%] vs 3.7% [1.4%-10.3%] and 2.0% [1.5%-6.6%], P < .01), especially because of less auto-triggering. CONCLUSIONS: Dedicated NIV ventilators allow better patient-ventilator synchrony than ICU and transport ventilators, even with their NIV algorithm. However, the NIV algorithm improves, at least slightly and with a wide variation among ventilators, triggering and/or cycling off synchronization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La guatlla (Coturnix coturnix) és actualment una espècie amb un estat de conservació desfavorable. Una amenaça per a la seva conservació és la hibridació que pot produir-se degut als alliberaments massius amb finalitats cinegètiques de la guatlla japonesa (Coturnix japonica) o híbrids provinents de granges de cria. Els objectius d’estudi són: a) Aprofundir en el sistema sexual de la guatlla, ja que el seu coneixement pot permetre entendre els mecanismes d’hibridació amb la guatlla japonesa o híbrids. b) Conèixer la taxa de supervivència i l’eficàcia biològica dels individus no nadius a àrees de reproducció de la guatlla. c) Buscar evidències directes d’hibridació en condicions naturals i caracteritzar-la. d) Determinar si existeix competència espermàtica interespecífica mitjançant experiments en captivitat. S’ha seguit el comportament en condicions naturals de parelles homospecífiques i heterospecífiques de mascles i femelles de guatlla i de guatlla japonesa o híbrids. S’ha analitzat la paternitat dels polls d’aquestes parelles i s’ha pogut conèixer quins aspectes del comportament (segons l’espècie) es relacionen amb l’eficàcia biològica dels adults. S’han analitzat el mateix tipus de dades obtingudes durant cinc temporades reproductives, en les que hi van participar només individus de guatlla. Així s’ha pogut comparar el comportament de l’espècie en presència i absència dels individus al•lòctons. Els resultats indiquen que existeixen dues estratègies sexuals entre els mascles de guatlla. L’estat físic del mascle en relació al dels altres mascles coetanis i el temps de permanència amb la femella determinen la seva taxa de paternitat. Existeix una fracció relativament petita però significativa de guatlla japonesa de granja que sobreviu en condicions naturals i s’hibrida amb la guatlla silvestre, predominantment de forma unidireccional, entre femella japonesa i mascle de guatlla. Aquestes femelles presenten un sistema d’aparellament majoritàriament monògam. Els anàlisis sobre els experiments de competència espermàtica s’estan realitzant a l’actualitat.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The recently released Affymetrix Human Gene 1.0 ST array has two major differences compared with standard 3' based arrays: (i) it interrogates the entire mRNA transcript, and (ii) it uses DNA targets. To assess the impact of these differences on array performance, we performed a series of comparative hybridizations between the Human Gene 1.0 ST and the Affymetrix HG-U133 Plus 2.0 and the Illumina HumanRef-8 BeadChip arrays. Additionally, both RNA and DNA targets were hybridized on HG-U133 Plus 2.0 arrays. The results show that the overall reproducibility of the Gene 1.0 ST array is best. When looking only at the high intensity probes, the reproducibility of the Gene 1.0 ST array and the Illumina BeadChip array is equally good. Concordance of array results was assessed using different inter-platform mappings. Agreements are best between the two labeling protocols using HG-U133 Plus 2.0 array. The Gene 1.0 ST array is most concordant with the HG-U133 array hybridized with cDNA targets. This may reflect the impact of the target type. Overall, the high degree of correspondence provides strong evidence for the reliability of the Gene 1.0 ST array.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new ambulatory method of monitoring physical activities in Parkinson's disease (PD) patients is proposed based on a portable data-logger with three body-fixed inertial sensors. A group of ten PD patients treated with subthalamic nucleus deep brain stimulation (STN-DBS) and ten normal control subjects followed a protocol of typical daily activities and the whole period of the measurement was recorded by video. Walking periods were recognized using two sensors on shanks and lying periods were detected using a sensor on trunk. By calculating kinematics features of the trunk movements during the transitions between sitting and standing postures and using a statistical classifier, sit-to-stand (SiSt) and stand-to-sit (StSi) transitions were detected and separated from other body movements. Finally, a fuzzy classifier used this information to detect periods of sitting and standing. The proposed method showed a high sensitivity and specificity for the detection of basic body postures allocations: sitting, standing, lying, and walking periods, both in PD patients and healthy subjects. We found significant differences in parameters related to SiSt and StSi transitions between PD patients and controls and also between PD patients with and without STN-DBS turned on. We concluded that our method provides a simple, accurate, and effective means to objectively quantify physical activities in both normal and PD patients and may prove useful to assess the level of motor functions in the latter.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Federal and state policy makers increasingly emphasize the need to reduce highway crash rates. This emphasis is demonstrated in Iowa’s recently released draft Iowa Strategic Highway Safety Plan and by the U.S. Department of Transportation’s placement of “improved transportation safety” at the top of its list of strategic goals. Thus, finding improved methods to enhance highway safety has become a top priority at highway agencies. The objective of this project is to develop tools and procedures by which Iowa engineers can identify potentially hazardous roadway locations and designs, and to demonstrate the utility of these tools by developing candidate lists of high crash locations in the State. An initial task, building an integrated database to facilitate the tools and procedures, is an important product, in and of itself. Accordingly, the Iowa Department of Transportation (Iowa DOT) Geographic Information Management System (GIMS) and Geographic Information System Accident Analysis and Location System (GIS-ALAS) databases were integrated with available digital imagery. (The GIMS database contains roadway characteristics, e.g., lane width, surface and shoulder type, and traffic volume, for all public roadways. GIS-ALAS records include data, e.g., vehicles, drivers, roadway conditions, and the crash severity, for crashes occurring on public roadways during then past 10 years.)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Student guidance is an always desired characteristic in any educational system, butit represents special difficulty if it has to be deployed in an automated way to fulfilsuch needs in a computer supported educational tool. In this paper we explorepossible avenues relying on machine learning techniques, to be included in a nearfuture -in the form of a tutoring navigational tool- in a teleeducation platform -InterMediActor- currently under development. Since no data from that platform isavailable yet, the preliminary experiments presented in this paper are builtinterpreting every subject in the Telecommunications Degree at Universidad CarlosIII de Madrid as an aggregated macro-competence (following the methodologicalconsiderations in InterMediActor), such that marks achieved by students can beused as data for the models, to be replaced in a near future by real data directlymeasured inside InterMediActor. We evaluate the predictability of students qualifications, and we deploy a preventive early detection system -failure alert-, toidentify those students more prone to fail a certain subject such that correctivemeans can be deployed with sufficient anticipation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two common herbicides; isoproturon and bentazon, are strong skin irritants and cross the skin barrier easily. Assessment of percutaneous absorption of these substances is a very important step in the evaluation of any dermal or transdermal dose, especially among agricultural workers who frequently have dermal exposures during crop treatment. The aims of the study were to determine the permeation rate of human skin for both herbicides in vitro, and histologically evaluate skin damage due to irritation at different concentrations. Skin penetration was assessed using a dynamic flow-through in vitro penetration system and analysis were performed with ion trap LC-MS (acidified water: acetronitile, C18 column). Two concentrations of bentazon (75 and 150 μg/mL) and isoproturon (125 and 250 μg/mL) in saline solution were applied on excised human skin from several donors. Saline water was used as receptor fluid. Collection times were: 4, 8, and 24 hours. After the experiments, the skin was removed and examined by histopathology for apoptosis, acanthosis, acantholysis and epidermolysis. The skin permeation rate, J, was calculated from the slope of the cumulative amount permeated as a function of time. The lag time, tL, was assigned from the time-axis intercept of the extrapolation of this linearity. Our results showed that tL for bentazon and isoproturon for both concentrations tested were similar; 2, 1.5 hours, respectively. Bentazon had a lowerer J compared to isoproturon; 350, 600 ng/cm2/h, respectively. Some acanthosis was observed after 8 hours of exposure to either of the two substances. In conclusion, our in vitro experiments demonstrate that bentazon and isoproturon cross the skin barrier within 2 hours even at very low concentrations, and showed some signs of skin damage. Future tests involve concentrations found in commercial products.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In Switzerland, a two-tier system based on impairment by any psychoactive substances which affect the capacity to drive safely and zero tolerance for certain illicit drugs came into force on 1 January 2005. According to the new legislation, the offender is sanctioned if Delta(9)-tetrahydrocannabinol THC is >or=1.5ng/ml or amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDEA), cocaine, free morphine are >or=15ng/ml in whole blood (confidence interval+/-30%). For all other psychoactive substances, impairment must be proven in applying the so-called "three pillars expertise". At the same time the legal blood alcohol concentration (BAC) limit for driving was lowered from 0.80 to 0.50g/kg. The purpose of this study was to analyze the prevalence of drugs in the first year after the introduction of the revision of the Swiss Traffic Law in the population of drivers suspected of driving under the influence of drugs (DUID). A database was developed to collect the data from all DUID cases submitted by the police or the Justice to the eight Swiss authorized laboratories between January and December 2005. Data collected were anonymous and included the age, gender, date and time of the event, the type of vehicle, the circumstances, the sampling time and the results of all the performed toxicological analyses. The focus was explicitly on DUID; cases of drivers who were suspected to be under the influence of ethanol only were not considered. The final study population included 4794 DUID offenders (4243 males, 543 females). The mean age of all drivers was 31+/-12 years (range 14-92 years). One or more psychoactive drugs were detected in 89% of all analyzed blood samples. In 11% (N=530) of the samples, neither alcohol nor drugs were present. The most frequently encountered drugs in whole blood were cannabinoids (48% of total number of cases), ethanol (35%), cocaine (25%), opiates (10%), amphetamines (7%), benzodiazepines (6%) and methadone (5%). Other medicinal drugs such as antidepressants and benzodiazepine-like were detected less frequently. Poly-drug use was prevalent but it may be underestimated because the laboratories do not always analyze all drugs in a blood sample. This first Swiss study points out that DUID is a serious problem on the roads in Switzerland. Further investigations will show if this situation has changed in the following years.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, electrical measurements show that the breakdown voltage,BVDG, of InP HEMTs increases following exposure to H2. This BVDG shift is nonrecoverable. The increase in BVDG is found to be due to a decrease in the carrier concentration in the extrinsic portion of the device.We provide evidence that H2 reacts with the exposed InAlAs surface in the extrinsic region next to the gate, changing the underlying carrier concentration. Hall measurements of capped and uncapped HEMT samples show that the decrease in sheet carrier concentration can be attributed to a modification of the exposed InAlAs surface. Consistent with this, XPS experiments on uncapped heterostructures give evidence of As loss from the InAlAs surface upon exposure to hydrogen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.