915 resultados para SURGICAL-CORRECTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In thermal deep-dermal burns, surgical debridement is normally used in conjunction with skin grafting or skin substitutes and debridement alone as a burn treatment is not usually practiced. The current study addresses whether or not debridement alone would enhance burn wound healing on small deep-dermal-partial thickness burns. This was a prospective and blinded experimental trial using a porcine deep-dermal-partial thickness burn model. Four burns, approximately 50 cm(2) in size, were created on each of eight pigs. Two burns from each pig were immediately surgically debrided and the other two were not debrided as the internal control. Hydrate gel together with paraffin gauze were used to cover the burns for four pigs and silver dressings for the other four. Clinical assessment of wound healing was conducted over a 6-week period. Skin samples were collected at the end of the experiment and histopathological evaluation was performed. The results show thinner scar formation and lower scar height in the debrided compared with nondebrided wounds in the hydrate gel/paraffin gauze groups. There were no statistically significant differences in wound healing assessment between the debrided and nondebrided wounds dressed with silver dressings. This study provides supporting evidence that immediate debridement with an appropriate dressing and without skin grafting may promote wound healing, suggesting its potential benefit for clinical patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Prevention strategies are critical to reduce infection rates in total joint arthroplasty (TJA), but evidence-based consensus guidelines on prevention of surgical site infection (SSI) remain heterogeneous and do not necessarily represent this particular patient population. Questions/Purposes What infection prevention measures are recommended by consensus evidence-based guidelines for prevention of periprosthetic joint infection? How do these recommendations compare to expert consensus on infection prevention strategies from orthopedic surgeons from the largest international tertiary referral centers for TJA? Patients and Methods A review of consensus guidelines was undertaken as described by Merollini et al. Four clinical guidelines met inclusion criteria: Centers for Disease Control and Prevention's, British Orthopedic Association, National Institute of Clinical Excellence's, and National Health and Medical Research Council's (NHMRC). Twenty-eight recommendations from these guidelines were used to create an evidence-based survey of infection prevention strategies that was administered to 28 orthopedic surgeons from members of the International Society of Orthopedic Centers. The results between existing consensus guidelines and expert opinion were then compared. Results Recommended strategies in the guidelines such as prophylactic antibiotics, preoperative skin preparation of patients and staff, and sterile surgical attire were considered critically or significantly important by the surveyed surgeons. Additional strategies such as ultraclean air/laminar flow, antibiotic cement, wound irrigation, and preoperative blood glucose control were also considered highly important by surveyed surgeons, but were not recommended or not uniformly addressed in existing guidelines on SSI prevention. Conclusion Current evidence-based guidelines are incomplete and evidence should be updated specifically to address patient needs undergoing TJA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims and objectives.  This study was undertaken to measure and analyse levels of acoustic noise in a General Surgical Ward. Method.  Measurements were undertaken using the Norsonic 116 sound level meter (SLM) recording noise levels in the internationally agreed ‘A’ weighted scale. Noise level data and observational data as to the number of staff present were obtained and recorded at 5-min intervals over three consecutive days. Results.  Results of noise level analysis indicated that mean noise level within this clinical area was 42.28 dB with acute spikes reaching 70 dB(A). The lowest noise level attained was that of 36 dB(A) during the period midnight to 7 a.m. Non-parametric testing, using Spearman's Rho (two-tailed), found a positive relationship between the number of staff present and the level of noise recorded, indicating that the presence of hospital personnel strongly influences the level of noise within this area. Relevance to clinical practice.  Whilst the results of this may seem self-evident in many respects the problems of excessive noise production and the exposure to it for patients, hospital personnel and relatives alike continues unabated. What must be of concern is the psychophysiological effects excessive noise exposure has on individuals, for example, decreased wound healing, sleep deprivation and cardiovascular stimulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Due to their high spatial resolution diodes are often used for small field relative output factor measurements. However, a field size specific correction factor [1] is required and corrects for diode detector over-response at small field sizes. A recent Monte Carlo based study has shown that it is possible to design a diode detector that produces measured relative output factors that are equivalent to those in water. This is accomplished by introducing an air gap at the upstream end of the diode [2]. The aim of this study was to physically construct this diode by placing an ‘air cap’ on the end of a commercially available diode (the PTW 60016 electron diode). The output factors subsequently measured with the new diode design were compared to current benchmark small field output factor measurements. Methods A water-tight ‘cap’ was constructed so that it could be placed over the upstream end of the diode. The cap was able to be offset from the end of the diode, thus creating an air gap. The air gap width was the same as the diode width (7 mm) and the thickness of the air gap could be varied. Output factor measurements were made using square field sizes of side length from 5 to 50 mm, using a 6 MV photon beam. The set of output factor measurements were repeated with the air gap thickness set to 0, 0.5, 1.0 and 1.5 mm. The optimal air gap thickness was found in a similar manner to that proposed by Charles et al. [2]. An IBA stereotactic field diode, corrected using Monte Carlo calculated kq,clin,kq,msr values [3] was used as the gold standard. Results The optimal air thickness required for the PTW 60016 electron diode was 1.0 mm. This was close to the Monte Carlo predicted value of 1.15 mm2. The sensitivity of the new diode design was independent of field size (kq,clin,kq,msr = 1.000 at all field sizes) to within 1 %. Discussion and conclusions The work of Charles et al. [2] has been proven experimentally. An existing commercial diode has been converted into a correction-less small field diode by the simple addition of an ‘air cap’. The method of applying a cap to create the new diode leads to the diode being dual purpose, as without the cap it is still an unmodified electron diode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background While adverse events primarily affect the patient, surgeons involved can also experience considerable distress. Aims The aim of the survey was to assess the impact of complications on the day-to-day life, work and health of Australian and New Zealand obstetricians and gynaecologists and to evaluate existing support systems and coping strategies. Methods A 43-question survey on self-assessment, quality assurance (QA) tools, impact of complications on individuals’ health and relationships, and support available was emailed to fellows, trainees, subspecialists and subspecialty trainees of the Royal Australian and New Zealand College of Obstetrics and Gynaecology (RANZCOG). We collected 606 responses from a target population of 2296 (response rate 26.3%). Results When complications occur, sleep was affected of 80%, family and social relationships of 55% and physical health of 48% of respondents. The major sources of support were from colleagues (83%), family (82%) and medical defence organisations (73%), with professional bodies perceived as providing least support. Nearly 80% of respondents felt the need to talk to someone they trust during times of complications. Overall, 100% of respondents used at least one QA tool (62% used two, 26% three and 9% four QA strategies). There were significant differences between respondent groups in use of the QA tools. Conclusions Surgical complications have a significant impact on the well-being of Australian and New Zealand obstetricians and gynaecologists. Existing support comes from colleagues and family, but structured, unbiased support for surgeons from a professional source is urgently warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review question/objective What are the most effective information sharing strategies used to reduce anxiety in families of patients undergoing elective surgery? This review seeks to synthesize the best available evidence in relation to the most effective information-sharing intervention to reduce anxiety for families waiting for patients undergoing an elective surgical procedure. The specific objectives are to review the effectiveness of evidence of interventions designed to reduce the anxiety of families waiting whilst their loved one undergoes a surgical intervention. A variety of interventions exist and include surgical nurse liaison services, intraoperative reporting either by face-to-face or telephone delivery, informational cards, visual information screens, and intraoperative paging devices for families. Inclusion criteria Types of participants All studies of family members over 18 years of age waiting for patients undergoing an elective surgical procedure will be included, including those waiting for both adult and paediatric patients. Studies of families waiting for other patient populations, eg emergency surgery, chemotherapy or intensive care patients will be excluded. Types of intervention(s)/phenomena of interest All information-sharing Interventions for families of patients undergoing an elective surgical procedure will be included, including but not limited to: surgical nurse liaison services, in-person intraoperative reporting, visual information screens, paging devices, informational cards and telephone delivery of intraoperative progress reports. Interventions that take place during the intraoperative phase of care only will be included in the review. Preadmission information sharing interventions will be excluded. Types of outcomes The outcomes of interest include: Primary outcome: the level of anxiety amongst family members or close relatives whilst waiting for patients undergoing surgery, as measured by a validated instrument (such as the S-Anxiety portion of the State-Trait Anxiety Inventory).4 Secondary outcomes: family satisfaction and other measurements that may be considered indicators of stress and anxiety, such as mean arterial pressure (MAP) and heart rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. We develop a sheep thoracic spine interbody fusion model to study the suitability of polycaprolactone-based scaffold and recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute within the thoracic spine. The surgical approach is a mini- open thoracotomy with relevance to minimally invasive deformity correction surgery for adolescent idiopathic scoliosis. To date there are no studies examining the use of this biodegradable implant in combination with biologics in a sheep thoracic spine model. METHODS. In the present study, six sheep underwent a 3-level (T6/7, T8/9 and T10/11) discectomy with randomly allocated implantation of a different graft substitute at each of the three levels; (i) calcium phosphate (CaP) coated polycaprolactone-based scaffold plus 0.54μg rhBMP-2, (ii) CaP coated PCL- based scaffold alone or (iii) autograft (mulched rib head). Fusion was assessed at six months post-surgery. RESULTS. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL- based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluations of the respective groups. Biomechanical testing revealed significantly higher stiffness for the rhBMP-2 plus PCL- based scaffold group in all loading directions in comparison to the other two groups. CONCLUSION. The results of this study demonstrate that rhBMP-2 plus PCL- based scaffold is a viable bone graft substitute, providing an optimal environment for thoracic interbody spinal fusion in a large animal model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous thromboembolism (VTE) is the term used to describe the disease process which presents as either deep vein thrombosis or pulmonary embolism. It is a major cause of death and disability worldwide and places a large financial burden on healthcare systems. Multiple risk factors have been identified for the development of VTE, including hospitalisation for acute medical illness and surgery. Documentation of VTE risk assessment is a critical part of any patient admission, driven by evidence that a risk assessment is a trigger for VTE prophylaxis to be considered. In the United Kingdom, healthcare services have set targets for VTE risk assessment documentation and financial incentives are linked to targets being met...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Current evidence to support non-medical prescribing is predominantly qualitative, with little evaluation of appropriateness. This study aims to evaluate the appropriateness of prescribing, and significance of omissions, from a doctor pharmacist collaborative prescribing model in an elective surgery pre admission clinic (PAC). Method A modified version of the Medication Appropriate Index (MAI) was developed, piloted and subsequently used by an expert panel, comprised of a surgeon, anaesthetist, clinical pharmacologist, pharmacist, resident medical officer (RMO) and clinical nurse. The tool was used to rate the appropriateness of prescribing of medications, and the significance of omissions in a 5% sample (N=19) of the total cohort from a randomised, controlled two arm trial of doctor-pharmacist collaborative prescribing. Results When reviewer assessments were combined, 32 out of 294 (10.9%) medications assessed for appropriateness in the control arm were classed as inappropriate, compared to 13 of 266 (4.9%) in the intervention arm. Out of 89 regular medications in the control arm, 25 (28%) were omitted from the medication charts, compared to 1 out of 55 (2%) in the intervention arm (p<0.001, fishers exact) On average, 52% of omissions in the control arm were judged to have potential for patient harm or ward inconvenience. Conclusion For the appropriateness of prescribing, overall results were similar between arms, as judged by individual panel members. Medication charts in the control arm contained significantly more omissions than in the intervention arm, a number of which were rated by the panel members as having the potential for patient harm or ward inconvenience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryo-electron tomography together with averaging of sub-tomograms containing identical particles can reveal the structure of proteins or protein complexes in their native environment. The resolution of this technique is limited by the contrast transfer function (CTF) of the microscope. The CTF is not routinely corrected in cryo-electron tomography because of difficulties including CTF detection, due to the low signal to noise ratio, and CTF correction, since images are characterised by a spatially variant CTF. Here we simulate the effects of the CTF on the resolution of the final reconstruction, before and after CTF correction, and consider the effect of errors and approximations in defocus determination. We show that errors in defocus determination are well tolerated when correcting a series of tomograms collected at a range of defocus values. We apply methods for determining the CTF parameters in low signal to noise images of tilted specimens, for monitoring defocus changes using observed magnification changes, and for correcting the CTF prior to reconstruction. Using bacteriophage PRDI as a test sample, we demonstrate that this approach gives an improvement in the structure obtained by sub-tomogram averaging from cryo-electron tomograms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim A recent Monte Carlo based study has shown that it is possible to design a diode that measures small field output factors equivalent to that in water. This is accomplished by placing an appropriate sized air gap above the silicon chip (1) with experimental results subsequently confirming that a particular Monte Carlo design was accurate (2). The aim of this work was to test if a new correction-less diode could be designed using an entirely experimental methodology. Method: All measurements were performed on a Varian iX at a depth of 5 cm, SSD of 95 cm and field sizes of 5, 6, 8, 10, 20 and 30 mm. Firstly, the experimental transfer of kq,clin,kq,msr from a commonly used diode detector (IBA, stereotactic field diode (SFD)) to another diode detector (Sun Nuclear, unshielded diode, (EDGEe)) was tested. These results were compared to Monte Carlo calculated values of the EDGEe. Secondly, the air gap above the EDGEe silicon chip was optimised empirically. Nine different air gap “tops” were placed above the EDGEe (air depth = 0.3, 0.6, 0.9 mm; air width = 3.06, 4.59, 6.13 mm). The sensitivity of the EDGEe was plotted as a function of air gap thickness for the field sizes measured. Results: The transfer of kq,clin,kq,msr from the SFD to the EDGEe was correct to within the simulation and measurement uncertainties. The EDGEe detector can be made “correction-less” for field sizes of 5 and 6 mm, but was ∼2% from being “correction-less” at field sizes of 8 and 10 mm. Conclusion Different materials will perturb small fields in different ways. A detector is only “correction-less” if all these perturbations happen to cancel out. Designing a “correction-less” diode is a complicated process, thus it is reasonable to expect that Monte Carlo simulations should play an important role.