932 resultados para SCANNING ELECTROCHEMICAL MICROSCOPE


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the last two decades, the third-dimension has become a focus of attention in electron microscopy to better understand the interactions within subcellular compartments. Initially, transmission electron tomography (TEM tomography) was introduced to image the cell volume in semi-thin sections (∼500nm). With the introduction of the focused ion beam scanning electron microscope, a new tool, FIB-SEM tomography, became available to image much larger volumes. During TEM tomography and FIB-SEM tomography, the resin section is exposed to a high electron/ion dose such that the stability of the resin embedded biological sample becomes an important issue. The shrinkage of a resin section in each dimension, especially in depth, is a well-known phenomenon. To ensure the dimensional integrity of the final volume of the cell, it is important to assess the properties of the different resins and determine the formulation which has the best stability in the electron/ion beam. Here, eight different resin formulations were examined. The effects of radiation damage were evaluated after different times of TEM irradiation. To get additional information on mass-loss and the physical properties of the resins (stiffness and adhesion), the topography of the irradiated areas was analysed with atomic force microscopy (AFM). Further, the behaviour of the resins was analysed after ion milling of the surface of the sample with different ion currents. In conclusion, two resin formulations, Hard Plus and the mixture of Durcupan/Epon, emerged that were considerably less affected and reasonably stable in the electron/ion beam and thus suitable for the 3-D investigation of biological samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polymorfian jatkuva seuranta saostuksessa on hyödyllistä suunnittelun ja kidetuotteen ominaisuuksien sekä kiteytystä seuraavan jatkoprosessoinnin kannalta. Tässä diplomityössä on tutkittu L-glutamiinihapon kahden (- ja ß) polymorfimuodon liukoisuuden riippuvuutta pH:sta ja lämpötilasta.Tulokseksi saatiin, että kummankin polymorfin liukoisuus kasvoi sekä pH:ta ettälämpötilaa kasvatettaessa. ¿¿muodon liukoisuus oli korkeampi kuin ß-muodon liukoisuus valituilla pH-arvoilla eri lämpötiloissa. Lisäksi seurattiin puolipanostoimisen saostuksen aikana 1-litraisella laboratoriokiteyttimellä muodostuvan kiteisen polymorfiseoksen koostumusta hyödyntäen in-line Raman-spektroskopiaa. Myös liuoksen pH-muutosta seurattiin sekä liuoksen koostumusta ATR FTIR-spektroskopian (Attenuated Total Reflection Fourier Transform Infrared Spectrometer) avulla. Tutkittavina muuttujina olivat mm. sekoitusintensiteetti, sekoitintyyppi, reaktanttien (natriumglutamaatti ja rikkihappo) konsentraatiot sekä syötetyn rikkihapon syöttökohta kiteyttimessä. Työhön sisältyi 36 koetta ja osa kokeista toistettiin tulosten oikeellisuuden tarkistamiseksi. Inline-mittaustulosten verifioimiseksi kidenäytteet analysoitiin myös käyttämällä konfokaali Raman-mikroskooppia. Kidemorfologiaa tutkittiin SEM-kuvien (Scanning Eletronic Microscope) avulla. Työ osoitti, että Raman-spektroskopia on joustava ja luotettava menetelmä saostusprosessin jatkuvaan seurantaan L-glutamiinihapolla. Alhaiset lähtöainepitoisuudet tuottivat pääasiassa ¿¿muotoa, kun taas alhainen sekoitusteho edisti ß-muodon muodostumista. Syöttökohta vaikutti merkittävästi polymorfiaan. Kun rikkihapon syöttökohta oli epäideaalisesti sekoitetulla vyöhykkeellä, nousi ylikylläisyystaso korkeaksi ja päätuote oli tällöin ß-muotoa. 6-lapainen vinolapaturbiini (nousukulma 45o) ja 6-lapainen levyturbiini eivät merkittävästi poikenneet toisistaan muodostuvien polymorfien osalta.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Uusia keinoja kullan erottamiseksi malmista on etsitty viimeaikoina taloudellisista ja ympäristöllisistä syistä kautta maailman. Syanidointimenetelmä on hallinnut kullan talteenottoayli sata vuotta. Menetelmässä kulta liuotetaan laimeaan syanidiliuokseen, jostase otetaan talteen aktiivihiilen avulla. Syanidin käyttöä pyritään kuitenkin vähentämään sen myrkyllisyyden takia. Lisäksi nykyään louhitaan enenemässä määrin malmia, josta on hankala rikastaa kulta kustannustehokkaasti syanidia käyttäen. Kullan talteenottoa syanidi- ja kloridiliuoksesta on selvitetty kirjallisuuden avulla. Kullan kemiaan liuotuksen aikana on perehdytty ennen kullan talteenottoa aktiivihiilellä. Aktiivihiilen elinkaari kullan adsorbenttinaon käsitelty valmistuksesta hylkäämiseen mukaan lukien hiilen myrkyttyminen prosessissa ja regenerointi. Aktiivi-hiilen käyttäytyminen syanidi- ja kloridiliuoksessa on selvitetty erikseen. Kullan talteenottoa kuparipitoisista malmeista on käsitelty. Kullan talteenottoa kloridiliuoksesta aktiivihiiltä käyttäen on tutkittu kokeellisesti. Pääasialliset tutkimuskohteet ovat adsorption kinetiikka, kuparin vaikutus adsorptioon, aktiivihiilen vaikutus adsorptioonja adsorboituneiden metallien strippaus hiilestä selektiivisesti. Hapettavan stippauksen vaikutus kullan desorptioon hiilestä on tutkittu yksityiskohtaisesti. Kullan erotusmenetelmät kuparimalmista aktiivihiiltä käyttäen on selvitetty diplomityön tulosten pohjalta. Diplomityön keskeisten tulosten perusteella kulta ei välttämättä saostu aktiivihiilen pinnalle kloridiliuoksesta. Havainto varmistettiin ladattujen hiilipartikkelien pyyhkäisyelektronimikroskooppikuvista ja partikkeleille tehdyistä mikroanalyyseistä. Kullan pelkistyminen metalliseksi kullaksi aktiivihiilessä voitaneen välttää käyttämällä erittäin hapettavia olosuhteita. Aktiivihiili ilmeisesti hapettuu näissä olosuhteissa, mikä mahdollistaa kultakloridin adsorboitumisen hiileen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The nuclear matrix, a proteinaceous network believed to be a scaffolding structure determining higher-order organization of chromatin, is usually prepared from intact nuclei by a series of extraction steps. In most cell types investigated the nuclear matrix does not spontaneously resist these treatments but must be stabilized before the application of extracting agents. Incubation of isolated nuclei at 37C or 42C in buffers containing Mg++ has been widely employed as stabilizing agent. We have previously demonstrated that heat treatment induces changes in the distribution of three nuclear scaffold proteins in nuclei prepared in the absence of Mg++ ions. We studied whether different concentrations of Mg++ (2.0-5 mM) affect the spatial distribution of nuclear matrix proteins in nuclei isolated from K562 erythroleukemia cells and stabilized by heat at either 37C or 42C. Five proteins were studied, two of which were RNA metabolism-related proteins (a 105-kD component of splicing complexes and an RNP component), one a 126-kD constituent of a class of nuclear bodies, and two were components of the inner matrix network. The localization of proteins was determined by immunofluorescent staining and confocal scanning laser microscope. Mg++ induced significant changes of antigen distribution even at the lowest concentration employed, and these modifications were enhanced in parallel with increase in the concentration of the divalent cation. The different sensitivity to heat stabilization and Mg++ of these nuclear proteins might reflect a different degree of association with the nuclear scaffold and can be closely related to their functional or structural role.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pigmenttipäällystyksen tarkoituksena on parantaa painopapereiden pintaominaisuuksia. Tämän työn tarkoituksena oli löytää sopiva päällystyspasta päällystetylle coldset-paperille. Kirjallisuusosassa on käsitelty coldset-painatusta ja sen ongelmia. Päällystysmenetelmän perusteita, pastan ominaisuuksia ja niiden vaikutusta päällystystulokseen on myös käsitelty. Lisäksi on esitelty joitakin päällystetyn paperin pinnantutkimusmenetelmiä. Kokeellisessa osassa on tutkittu erilaisten pastakoostumusten ja päällystemäärien sekä kalanteroinnin vaikutusta paperin painettavuuteen. Paperit on päällystetty Helicoaterilla ja joitakin pastoja on testattu myös pilot-mittakaavaisessa päällystyksessä. Selitystä paperin käyttäytymiseen painatuksessa on etsitty päällystetyn paperin pintarakenteesta. Paras painettavuus saavutetaan päällysteellä, jossa pigmenttinä on vain karbonaatti. Painojälkeä voidaan parantaa käyttämällä kalsinoitua kaoliinia yhdessä karbonaatin kanssa, mutta tämän päällysteen pintalujuus ei ole riittävä CSWO-painatukseen. Tärkkipigmentti parantaa veden ja painovärin absorptiota ja siten tekee painetun tuotteen kuivemmaksi ja miellyttävämmän tuntuiseksi, mutta aiheuttaa smearingia. Tämä johtuu liian nopeasta musteen asettuvuudesta. "Pehmeä" SB-lateksi soveltuu paremmin offset-painatukseen kuin "kova" lateksi, joka sisältää myös PVAc:ta. "Pehmeällä" lateksilla saadaan parempi pintalujuus ja painojälki kuin "kovalla" lateksilla. Paperin pölyävyyttä painatuksessa voidaan vähentää nostamalla päällystemäärää ja laskemalla pastan kuiva-ainepitoisuutta. Kalanteroinnilla ei pintalujuutta tai painojälkeä voida parantaa. Selitys tutkimuksessa käsiteltyjen papereiden painojäljelle ja painettavuudelle löydetään tutkimalla päällysteen pintarakennetta. Painojälkeen vaikuttaa eniten päällysteen peittoaste. Huonoa peittävyyttä voidaan parantaa nostamalla päällystemäärää. Pölyäminen painatuksessa johtuu pigmenteistä, jotka eivät ole sidottuja paperin pintaan. Tämä taas johtuu pastan huonosta vesiretentiosta. Hyödyllisintä tietoa näiden papereiden pintarakenteesta saadaan tutkimalla pintaa pyyhkäisyelektonimikroskoopilla (SEM), atomivoimamikroskoopilla (AFM) ja laserindusoidulla plasmaspektrometrilla (LIPS). LIPSin etuna on se, että päällystemääräjaukauma voidaan määrittää sekä x-y- että z-suunnassa samanaikaisesti samasta kohdasta. LIPSissä myös näytteen preparointitarve on hyvin vähäinen.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study examines the correlation between buccal dental microwear and stable isotopes. The buccal surface of post-canine teeth casts from El Collado, the largest Mesolithic site in Spain, were examined under Scanning Electron Microscope; photomicrographs were taken from the middle third of the buccal surface with magnification 100X. Only six individuals passed the criteria for buccal dental microwear analysis. The photomicrographs were treated by adobe Photoshop 8.01 to cover an area 0.56 mm² of middle third of buccal surface, the output photomicrographs were digitized using Sigmascan Pro 5 by SPSS. Then the correlation between buccal microwear pattern and stable isotopes of the same individuals, of the previous study of Guixe et al., 2006, was examined using a Pearson test. Statistical analysis revealed that there is no significant correlation between stable isotopes and buccal dental microwear of the people of the Mesolithic site of El Collado. The historical and archaeological documentation suggest that the Mesolithic people tended to consume marine food. Fish-drying techniques were used during the Mesolithic period which allowed the introduction of dust and sand to the fish. These abrasive particles affected the buccal dental microwear pattern, so that no correlation between the isotopes and microwear may be expected. This also suggests that the buccal dental microwear pattern exceeds dietary reconstruction to reconstruct food processing techniques.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present paper has as objective to apply a sequential Cluster Analysis to the atmospheric particles: Hierarchical Cluster Analysis followed by Nonhierarchical Cluster Analysis. The hierarchical cluster analysis results were used as start point for the nonhierarchical cluster analysis as an agglomerative technique. These particles were taken from two areas of the metropolitan region of Porto Alegre, Charqueadas and Sapucaia do Sul., from may /97 to may/98, using a High Volume Sampler (Hi-Vol). Around 10,000 particles were analysed by Scanning Electron Microscope with Energy-Dispersive X-Ray microanalysis (SEM-EDS). The Hierarchical Cluster Analysis allowed the identification of five groups of particles, whose amounts were differentiated according to the summer and the winter campaigns. The abundance of each type of particles inside each group according to the different sections was verified by the Nonhierarchical Cluster Analysis, resulting in information about the emissions sources. The groups of particles of Si/Al and Si and of Fe/Zn and Fe for Charqueadas were more significant in section 2 and 3 (NW and W wind directions) and in section 1 (SE wind direction), evidencing the influence of the coal power plant and steel industry, respectively located in these quadrants. In Sapucaia do Sul the data were more heterogeneous, causing a certain difficulty to identify the source as anthropogenic. Nevertheless the group of particles containing Fe was found in sectors of NW/W wind directions which shows the influence of the steel plant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The development of load-bearing osseous implant with desired mechanical and surface properties in order to promote incorporation with bone and to eliminate risk of bone resorption and implant failure is a very challenging task. Bone formation and resoption processes depend on the mechanical environment. Certain stress/strain conditions are required to promote new bone growth and to prevent bone mass loss. Conventional metallic implants with high stiffness carry most of the load and the surrounding bone becomes virtually unloaded and inactive. Fibre-reinforced composites offer an interesting alternative to metallic implants, because their mechanical properties can be tailored to be equal to those of bone, by the careful selection of matrix polymer, type of fibres, fibre volume fraction, orientation and length. Successful load transfer at bone-implant interface requires proper fixation between the bone and implant. One promising method to promote fixation is to prepare implants with porous surface. Bone ingrowth into porous surface structure stabilises the system and improves clinical success of the implant. The experimental part of this work was focused on polymethyl methacrylate (PMMA) -based composites with dense load-bearing core and porous surface. Three-dimensionally randomly orientated chopped glass fibres were used to reinforce the composite. A method to fabricate those composites was developed by a solvent treatment technique and some characterisations concerning the functionality of the surface structure were made in vitro and in vivo. Scanning electron microscope observations revealed that the pore size and interconnective porous architecture of the surface layer of the fibre-reinforced composite (FRC) could be optimal for bone ingrowth. Microhardness measurements showed that the solvent treatment did not have an effect on the mechanical properties of the load-bearing core. A push-out test, using dental stone as a bone model material, revealed that short glass fibre-reinforced porous surface layer is strong enough to carry load. Unreacted monomers can cause the chemical necrosis of the tissue, but the levels of leachable resisidual monomers were considerably lower than those found in chemically cured fibre-reinforced dentures and in modified acrylic bone cements. Animal experiments proved that surface porous FRC implant can enhance fixation between bone and FRC. New bone ingrowth into the pores was detected and strong interlocking between bone and the implant was achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työn teoriaosassa käsitellään ruostumattomia teräksiä ja terästen metallurgiaan vaikuttavia tekijöitä yleisesti, sekä terästen hitsattavuutta. Hitsauksesta teoriassa käydään läpi laser- ja kaasukaarihitsausta ja hitsin metallurgiaan vaikuttavia tekijöitä. Kokeellisessa osassa paneudutaan kahdeksan eri ruostumattoman teräksen hitsien metallurgiaan ja metallurgiassa tapahtuviin muutoksiin hitsausparametrien mukaan. Koemateriaaleina on neljä austeniittista ruostumatonta terästä, 201, 301LN, 316L ja 254 SMO, kaksi austeniittis-ferriittistä ruostumatonta terästä, 2101 LDX ja 2205, sekä kaksi ferriittistä ruostumatonta terästä, 430 ja 1.4003. Hitsien mikrorakenteen tutkimisessa käytettiin sekä valomikroskooppia sekä joissain tapauksissa pyyhkäisyelektronimikroskooppia. Lisäksi työn kokeellisessa osassa paneuduttiin hitsien metallografisiin syövytystekniikoihin. Kokeiden perusteella voidaan sanoa, että hitsin metallurgia riippuu hitsauksen aikaisesta lämpösyklistä ja hitsausparametreilla voidaan vaikuttaa tämän lämpösyklin muotoon. Austeniittis-ferriittisillä teräksillä hitsauksen aikaisesta lämpösyklistä riippuu pitkälti hitsin austeniitti-ferriitti-suhde. Ferriittisillä teräksillä lämpösyklin muoto vaikuttaa hitsiin muodostuvan martensiitin kovuuteen ja määrään sekä rakenteen hienojakoisuuteen. Austeniittisilla teräksillä lämpösyklinmuodon vaikutus riippuu pitkälti teräksen seostusasteesta ja seosaineista. Austeniittisilla teräksillä kokeissa havaittuja muutoksia, parametrien muutosten mukaan oli muun muassa suotautumisen voimakkuuden

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The uncertainty of any analytical determination depends on analysis and sampling. Uncertainty arising from sampling is usually not controlled and methods for its evaluation are still little known. Pierre Gy’s sampling theory is currently the most complete theory about samplingwhich also takes the design of the sampling equipment into account. Guides dealing with the practical issues of sampling also exist, published by international organizations such as EURACHEM, IUPAC (International Union of Pure and Applied Chemistry) and ISO (International Organization for Standardization). In this work Gy’s sampling theory was applied to several cases, including the analysis of chromite concentration estimated on SEM (Scanning Electron Microscope) images and estimation of the total uncertainty of a drug dissolution procedure. The results clearly show that Gy’s sampling theory can be utilized in both of the above-mentioned cases and that the uncertainties achieved are reliable. Variographic experiments introduced in Gy’s sampling theory are beneficially applied in analyzing the uncertainty of auto-correlated data sets such as industrial process data and environmental discharges. The periodic behaviour of these kinds of processes can be observed by variographic analysis as well as with fast Fourier transformation and auto-correlation functions. With variographic analysis, the uncertainties are estimated as a function of the sampling interval. This is advantageous when environmental data or process data are analyzed as it can be easily estimated how the sampling interval is affecting the overall uncertainty. If the sampling frequency is too high, unnecessary resources will be used. On the other hand, if a frequency is too low, the uncertainty of the determination may be unacceptably high. Variographic methods can also be utilized to estimate the uncertainty of spectral data produced by modern instruments. Since spectral data are multivariate, methods such as Principal Component Analysis (PCA) are needed when the data are analyzed. Optimization of a sampling plan increases the reliability of the analytical process which might at the end have beneficial effects on the economics of chemical analysis,

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The major applications of organoclays are in adsorption of organic polluents. The objective of this work was the synthesis and characterization of organoclays using differents amounts of cationic surfactant hexadecyltrimethylammonium bromide. The clays were characterized by low angle x-ray diffraction (XRD), scanning electron microscope (SEM), infrared with Fourier tranformation (FTIR), BET surface area, elemental analysis (CHN), Foster swell and adsorption of methylene blue. The surfactant can adsorb in differents forms in the interlamelar region changed the basal spacing. The presence of the surfactant adsorbed can be favorable or not in adsorption of the methylene blue due the different interactions dye-organoclays.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ceramics are widely used in industrial applications due to their advantageous thermal and mechanical stability. Corrosion of ceramics is a great problem resulting in significant costs. Coating is one method of reducing adversities of corrosion. There are several different thin film deposition processes available such as sol-gel, Physical and Chemical Vapour Deposition (PVD and CVD). One of the CVD processes, called Atomic Layer Deposition (ALD) stands out for its excellent controllability, accuracy and wide process capability. The most commonly mentioned disadvantage of this method is its slowness which is partly compensated by its capability of processing large areas at once. Several factors affect the ALD process. Such factors include temperature, the grade of precursors, pulse-purge times and flux of precursors as well as the substrate used. Wrongly chosen process factors may cause loss of self-limiting growth and thus, non-uniformities in the deposited film. Porous substrates require longer pulse times than flat surfaces. The goal of this thesis was to examine the effects of ALD films on surface properties of a porous ceramic material. The analyses applied were for permeability, bubble point pressure and isoelectric point. In addition, effects of the films on corrosion resistance of the substrate in aqueous environment were investigated. After being exposured to different corrosive media the ceramics and liquid samples collected were analysed both mechanically and chemically. Visual and contentual differences between the exposed and coated ceramics versus the untreated and uncoated ones were analysed by scanning electron microscope. Two ALD film materials, dialuminium trioxide and titanium dioxide were deposited on the ceramic substrate using different pulse times. The results of both film materials indicated that surface properties of the ceramic material can be modified to some extent by the ALD method. The effect of the titanium oxide film on the corrosion resistance of the ceramic samples was observed to be fairly small regardless of the pulse time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polymeric materials have been used in dental applications for decades. Adhesion of polymeric materials to each other and to the tooth substrate is essential to their successful use. The aim of this series of studies was two-folded. First, to improve adhesion of poly(paraphenylene) based rigid rod polymer (RRP) to other dental polymers, and secondly, to evaluate the usability of a new dentin primer system based on RRP fillers. Poly(paraphenylene) based RRP would be a tempting material for dental applications because of its good mechanical properties. To be used in dental applications, reliable adhesion between RRP and other dental polymers is required. In this series of studies, the adhesion of RRP to denture base polymer and the mechanical properties of RRP-denture base polymer-material combination were evaluated. Also adhesion of BisGMA-TEGDMA-resin to RRP was determined. Different surface treatments were tested to improve the adhesion of BisGMA-TEGDMA-resin to RRP. Results were based on three-point bending testing, Vickers surface hardness test and scanning electron microscope analysis (SEM), which showed that no reliable adhesion between RRP and denture base polymer was formed. Addition of RRP filler to denture base polymer increased surface hardness and flexural modulus but flexural strength decreased. Results from the shear bond strength test and SEM revealed that adhesion between resin and RRP was possible to improve by surface treatment with dichloromethane (DCM) based primer and a new kind of adhesive surface can be designed. The current dentin bonding agents have good immediate bond strength, but in long term the bond strength may decrease due to the detrimental effect of water and perhaps by matrix metalloproteinases. This leads to problems in longevity of restorations. Current bonding agents use organic monomers. In this series of studies, RRP filled dentin primer was tested in order to decrease the water sorption of the monomer system of the primers. The properties of new dentin primer system were evaluated in vitro by comparing it to commercial etch and rinse adhesive system. The results from the contact angle measurements and SEM showed that experimental primer with RRP reinforcement provided similar resin infiltration to dentin collagen and formed the resin-dentin interface as the control primer. Microtensile bond strength test and SEM revealed that in short term water storing, RRP increased bond strength and primer with BMEP-monomer (bis[2-(methacryloyloxy)-ethyl]phosphate) and high solvent concentration provided comparable bonding properties to the commercial control primers. In long term water storing, the high solvent-monomer concentration of the experimental primers decreased bond strength. However, in low solvent-monomer concentration groups, the long-term water storing did not decrease the bond strength despite the existence of hydrophilic monomers which were used in the system. These studies demonstrated that new dentin primer system reached the mechanical properties of current traditional etch and rinse adhesive system in short time water storing. Improved properties can be achieved by further modifications of the monomer system. Studies of the adhesion of RRP to other polymers suggest that adhesion between RRP and other dental polymers is possible to obtain by certain surface treatments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In dentistry, yttrium partially stabilized zirconia (ZrO2) has become one of the most attractive ceramic materials for prosthetic applications. The aim of this series of studies was to evaluate whether certain treatments used in the manufacturing process, such as sintering time, color shading or heat treatment of zirconia affect the material properties. Another aim was to evaluate the load-bearing capacity and marginal fit of manually copy-milled custom-made versus prefabricated commercially available zirconia implant abutments. Mechanical properties such as flexural strength and surface microhardness were determined for green-stage milled and sintered yttrium partially stabilized zirconia after different sintering time, coloring process and heat treatments. Scanning electron microscope (SEM) was used for analyzing the possible changes in surface structure of zirconia material after reduced sintering time, coloring and heat treatments. Possible phase change from the tetragonal to the monoclinic phase was evaluated by X-ray diffraction analysis (XRD). The load-bearing capacity of different implant abutments was measured and the fit between abutment and implant replica was examined with SEM. The results of these studies showed that the shorter sintering time or the thermocycling did not affect the strength or surface microhardness of zirconia. Coloring of zirconia decreased strength compared to un-colored control zirconia, and some of the colored zirconia specimens also showed a decrease in surface microhardness. Coloring also affected the dimensions of zirconia. Significantly decreased shrinkage was found for colored zirconia specimens during sintering. Heat treatment of zirconia did not seem to affect materials’ mechanical properties but when a thin coating of wash and glaze porcelain was fired on the tensile side of the disc the flexural strength decreased significantly. Furthermore, it was found that thermocycling increased the monoclinic phase on the surface of the zirconia. Color shading or heat treatment did not seem to affect phase transformation but small monoclinic peaks were detected on the surface of the heat treated specimens with a thin coating of wash and glaze porcelain on the opposite side. Custom-made zirconia abutments showed comparable load-bearing capacity to the prefabricated commercially available zirconia abutments. However, the fit of the custom-made abutments was less satisfactory than that of the commercially available abutments. These studies suggest that zirconia is a durable material and other treatments than color shading used in the manufacturing process of zirconia bulk material does not affect the material’s strength. The decrease in strength and dimensional changes after color shading needs to be taken into account when fabricating zirconia substructures for fixed dental prostheses. Manually copy-milled custom-made abutments have acceptable load-bearing capacity but the marginal accuracy has to be evaluated carefully.