934 resultados para Running-based anaerobic sprint test


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electronic applications are currently developed under the reuse-based paradigm. This design methodology presents several advantages for the reduction of the design complexity, but brings new challenges for the test of the final circuit. The access to embedded cores, the integration of several test methods, and the optimization of the several cost factors are just a few of the several problems that need to be tackled during test planning. Within this context, this thesis proposes two test planning approaches that aim at reducing the test costs of a core-based system by means of hardware reuse and integration of the test planning into the design flow. The first approach considers systems whose cores are connected directly or through a functional bus. The test planning method consists of a comprehensive model that includes the definition of a multi-mode access mechanism inside the chip and a search algorithm for the exploration of the design space. The access mechanism model considers the reuse of functional connections as well as partial test buses, cores transparency, and other bypass modes. The test schedule is defined in conjunction with the access mechanism so that good trade-offs among the costs of pins, area, and test time can be sought. Furthermore, system power constraints are also considered. This expansion of concerns makes it possible an efficient, yet fine-grained search, in the huge design space of a reuse-based environment. Experimental results clearly show the variety of trade-offs that can be explored using the proposed model, and its effectiveness on optimizing the system test plan. Networks-on-chip are likely to become the main communication platform of systemson- chip. Thus, the second approach presented in this work proposes the reuse of the on-chip network for the test of the cores embedded into the systems that use this communication platform. A power-aware test scheduling algorithm aiming at exploiting the network characteristics to minimize the system test time is presented. The reuse strategy is evaluated considering a number of system configurations, such as different positions of the cores in the network, power consumption constraints and number of interfaces with the tester. Experimental results show that the parallelization capability of the network can be exploited to reduce the system test time, whereas area and pin overhead are strongly minimized. In this manuscript, the main problems of the test of core-based systems are firstly identified and the current solutions are discussed. The problems being tackled by this thesis are then listed and the test planning approaches are detailed. Both test planning techniques are validated for the recently released ITC’02 SoC Test Benchmarks, and further compared to other test planning methods of the literature. This comparison confirms the efficiency of the proposed methods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper constructs a unit root test baseei on partially adaptive estimation, which is shown to be robust against non-Gaussian innovations. We show that the limiting distribution of the t-statistic is a convex combination of standard normal and DF distribution. Convergence to the DF distribution is obtaineel when the innovations are Gaussian, implying that the traditional ADF test is a special case of the proposed testo Monte Carlo Experiments indicate that, if innovation has heavy tail distribution or are contaminated by outliers, then the proposed test is more powerful than the traditional ADF testo Nominal interest rates (different maturities) are shown to be stationary according to the robust test but not stationary according to the nonrobust ADF testo This result seems to suggest that the failure of rejecting the null of unit root in nominal interest rate may be due to the use of estimation and hypothesis testing procedures that do not consider the absence of Gaussianity in the data.Our results validate practical restrictions on the behavior of the nominal interest rate imposed by CCAPM, optimal monetary policy and option pricing models.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

DANTAS, Rodrigo Assis Neves; NÓBREGA, Walkíria Gomes da; MORAIS FILHO, Luiz Alves; MACÊDO, Eurides Araújo Bezerra de ; FONSECA , Patrícia de Cássia Bezerra; ENDERS, Bertha Cruz; MENEZES, Rejane Maria Paiva de; TORRES , Gilson de Vasconcelos. Paradigms in health care and its relationship to the nursing theories: an analytical test . Revista de Enfermagem UFPE on line. v.4,n.2, p.16-24.abr/jun. 2010. Disponível em < http://www.ufpe.br/revistaenfermagem/index.php/revista>.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the application of PCR technique for the detection of BoHV-5 in routinely formalin-fixed, paraffin-embedded brain tissues in 20 naturally infected calves affected by fatal meningoencephalitis. Brains were divided into two halves, one kept fresh for virus isolation and PCR assay, targeting the glycoprotein C gene from BoHV-5 genome. The other half brain, corresponding to posterior cortex region, was submitted to formalin fixation and embedded into paraffin blocks for microscopic evaluation and total DNA isolation. Most of the slides showed severe multifocal non-supurative encephalitis with neuronal degeneration, neurophagia, and no acidophilic intranuclear inclusions could be found in neurons and glial. The 20 fresh samples were confirmed, by virus isolation and PCR assay, as having the BoHV-5 virus and, respective glicoprotein C sequence, while 15 of 20 formalin-fixed, paraffin-embedded samples were considered positive for the same analysis. The results revealed the first description of PCR efficiency, applied to formalin-fixed, paraffin-embedded brain collected from naturally infected calves, improving the detection of BoHV-5 from archival samples in South America. (c) 2007 Published by Elsevier B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tegtbur et al. [23] devised a new method able to estimate the intensity at maximal lactate steady state termed lactate minimum test. According to Billat et al. [7], no studies have yet been published on the affect of training on highest blood lactate concentration that can be maintained over time without continual blood lactate accumulation. Therefore, the aim of the present study was to verify the effect of soccer training on the running speed and the blood lactate concentration (BLC) at the lactate minimum test (Lac(min)). Thirteen Brazilian male professional soccer players, all members of the same team playing at National level, volunteered for this study. Measurements were carried out before (pre) and after (post) eight weeks of soccer training. The Lac(min) test was adapted to the procedures reported by Tegtbur et al. [23]. The running speed at the Lac(min) test was taken when the gradient of the line was zero. Differences in running speed and blood lactate concentration at the Lac(min) test before (pre) and after (post) the training program were evaluated by Student's paired t-test. The training program increased the running speed at the Lac(min) test (14.94 +/- 0.21 vs. 15.44 +/- 0.42* km(.)h(-1)) and the blood lactate concentration (5.11 +/- 2.31 vs. 6.93 +/- 1.33* mmol(.)L(-1)). The enhance in the blood lactate concentration may be explained by an increase in the lactate/H+ transport capacity of human skeletal muscle verified by other authors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Foi objetivo deste estudo caracterizar a relação entre o nível de aptidão física, desempenho e solicitação metabólica em futebolistas durante situação real de jogo. Seis jogadores de futebol profissional com média de idade de 20,8 ± 2,6 anos (17-25), peso 70,4 ± 7,5kg (63-81,3) e altura 173,3 ± 9,7cm (166-188), foram submetidos a testes de aptidão física em campo e análise cinematográfica durante a partida. Os testes de aptidão física foram realizados em campo, com medições de lactato sanguíneo. A via metabólica alática foi avaliada por meio de cinco corridas na distância de 30m, em velocidade máxima, com pausa passiva de um minuto entre cada corrida. As concentrações de lactato foram medidas no 1º, 3º e 5º minuto após o término das cinco corridas. Para detecção do limiar anaeróbio foram realizadas 3 corridas de 1.200m nas intensidades de 80, 85 e 90% da velocidade máxima para essa distância, com intervalo passivo de 15 minutos entre cada corrida. As dosagens de lactato sanguíneo foram feitas no 1º, 3º e 5º minuto de repouso passivo após cada corrida. Os futebolistas foram submetidos à filmagem individual durante o transcorrer do jogo e as concentrações de lactato foram medidas antes, no intervalo e no final da partida para análise da solicitação energética e metabólica, respectivamente. Os seguintes resultados foram verificados: 1) o limiar anaeróbio em velocidade de corrida, correspondente à concentração de lactato sanguíneo de 4mmol.L_1 foi encontrado aos 268 ± 28m.min_1 ou 16,1 ± 1,6km.h_1; 2) a velocidade média e a concentração de lactato máximo nas corridas de 30m foram de 6,9 ± 0,2m.s_1 e 4,5 ± 1,0mmol.L_1, respectivamente; 3) a distância total percorrida foi de 10.392 ± 849m, sendo 5.446 ± 550m para o primeiro e 4.945 ± 366m para o segundo tempo, respectivamente; 4) os valores médios encontrados nas concentrações de lactato sanguíneo foram de 1,58 ± 0,37; 4,5 ± 0,42 e 3,46 ± 1,54mmol.L_1 antes, no intervalo do primeiro para o segundo tempo e ao final da a,respectivamente; e 5) a distância média total atingida ao final das partidas pelos jogadores de meio-campo (10.910 ± 121m) foi ligeiramente maior que a percorrida pelos atacantes (10.377 ± 224m) e defensores (9.889 ± 102m), mas não significativa. Houve correlação negativa (r =- 0,84; p < 0,05) entre o limiar anaeróbio (268 ± 28m.min_1 ou 16,1 ± 1,6km.h_1) e a concentração de lactato sanguíneo (4,5 ± 0,4 mmol.L_1) no primeiro tempo do jogo. Portanto, os resultados sugerem que a capacidade aeróbia é um determinante importante para suportar a longa duração da partida e recuperar mais rapidamente os futebolistas dos esforços realizados em alta intensidade, com o desenvolvimento de concentrações de lactato sanguíneo menores ao final do primeiro e segundo tempo das partidas.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of the present study was to verify the applicability of anaerobic work capacity (AWC) determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1) A critical frequency test used to determinate the anaerobic work capacity; 2) Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 +/- 29.1 table tennis balls. AWC was not related to peak (r = -0.25), mean (r = -0.02), relative peak (r = -0.49) or relative mean power (r = 0.01), nor fatigue index (r = -0.52) (Wingate leg ergometer). Similar correlations for peak (r = -0.34), mean (r = -0.04), relative peak (r = -0.49), relative mean power (r = -0.14) and peak blood lactate concentration (r = -0.08) were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O objetivo deste estudo foi analisar a validade do consumo máximo de oxigênio (VO2max), velocidade associada ao VO2max (vVO2max), tempo de exaustão na vVO2max (Tlim), limiar anaeróbio (LAn), economia de corrida (EC) e força explosiva (FE) para predizer a performance aeróbia de corredores de endurance nas distâncias de 1.500m, 5.000m e 10.000m. Participaram deste estudo 11 corredores de endurance moderadamente treinados (28,36 ± 6,47 anos) que realizaram os seguintes testes: provas simuladas em uma pista de 400m em diferentes dias, nas distâncias de 10.000m, 5.000m e 1.500m; teste incremental máximo para determinar os índices VO2max, vVO2max, e LAn; um teste submáximo de carga constante para determinar a EC, seguido por um teste máximo também de carga constante a 100% da vVO2max para determinar o Tlim; e um teste de salto vertical para determinar a FE. de acordo com a análise de regressão múltipla, a vVO2max utilizada de forma isolada explicou 57% da variação de performance na prova de 1.500m. No entanto, quando o Tlim, a FE e a vVO2max foram analisados em conjunto, a explicação para a performance nessa prova foi de 88%. Nos 5.000m, o Tlim, a vVO2max e o LAn responderam por 88% da variação de performance (p < 0,05). Diferentemente, na prova de 10.000m, o LAn foi a única variável que apresentou capacidade de predição de performance. em conclusão, a predição da performance aeróbia de corredores moderadamente treinados por meio de variáveis fisiológicas e neuromusculares é dependente da distância da prova (1.500m, 5.000m e 10.000m)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The equilibrium point between blood lactate production and removal (La-min(-)) and the individual anaerobic threshold (IAT) protocols have been used to evaluate exercise. During progressive exercise, blood lactate [La-](b), catecholamine and cortisol concentrations, show exponential increases at upper anaerobic threshold intensities. Since these hormones enhance blood glucose concentrations [Glc](b), this study investigated the [Glc] and [La-](b) responses during incremental tests and the possibility of considering the individual glucose threshold (IGT) and glucose minimum;(Glc(min)) in addition to IAT and La-min(-) in evaluating exercise. A group of 15 male endurance runners ran in four tests on the track 3000 m run (v(3km)); IAT and IGT- 8 x 800 m runs at velocities between 84% and 102% of v(3km); La-min(-) and Glc(min) - after lactic acidosis induced by a 500-m sprint, the subjects ran 8 x 800 m at intensities between 87% and 97% of v(3km); endurance test (ET)- 30 min at the velocity of IAT. Capillary blood (25 mu l) was collected for [La-](b) and [Glc](b) measurements. The TAT and IGT were determined by [La-](b) and [Glc](b) kinetics during the second test. The La-min(-) and Glc(min) were determined considering the lowest [La-] and [Glc](b) during the third test. No differences were observed (P < 0.05) and high correlations were obtained between the velocities at IAT [283 (SD 19) and IGT 281 (SD 21)m. min(-1); r = 0.096; P < 0.001] and between La,, [285 (SD 21)] and Glc(min) [287 (SD 20) m. min(-1) = 0.77; P < 0.05]. During ET, the [La-](b) reached 5.0 (SD 1.1) and 5.3 (SD 1.0) mmol 1(-1) at 20 and 30 min, respectively (P > 0.05). We concluded that for these subjects it was possible to evaluate the aerobic capacity by IGT and Glc(min), as well as by IAT and La-min(-).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The running velocities associated to lactate minimum (V-lm), heart rate deflection (V-HRd), critical velocity (CV), 3000 M (V-3000) and 10000 m performance (V-10km) were compared. Additionally the ability of V-lm and VHRd on identifying sustainable velocities was investigated.Methods. Twenty runners (28.5 +/- 5.9 y) performed 1) 3000 m running test for V3000; 2) an all-out 500 in sprint followed by 6x800 m incremental bouts with blood lactate ([lac]) measurements for V-lm; 3) a continuous velocity-incremented test with heart rate measurements at each 200 m for V-HRd; 4) participants attempted to 30 min of endurance test both at V-lm(ETVlm) and V-HRd(ETVHRd). Additionally, the distance-time and velocity-1/time relationships produced CV by 2 (500 m and 3000 m) or 3 predictive trials (500 m, 3000 m and distance reached before exhaustion during ETVHRd), and a 10 km race was recorded for V-10km.Results. The CV identified by different methods did not differ to each other. The results (m(.)min(-1)) revealed that V-.(lm) (281 +/- 14.8)< CV (292.1 +/- 17.5)=V-10km (291.7 +/- 19.3)< V-HRd (300.8 +/- 18.7)=V-3000 (304 +/- 17.5) with high correlation among parameters (P < 0.001). During ETVlm participants completed 30 min of running while on the ETVHRd they lasted only 12.5 +/- 8.2 min with increasing [lac].Conclusion. We evidenced that CV and Vim track-protocols are valid for running evaluation and performance prediction and the parameters studied have different significance. The V-lm reflects the moderate-high intensity domain (below CV), can be sustained without [lac] accumulation and may be used for long-term exercise while the V-HRd overestimates a running intensity that can be sustained for long-time. Additionally, V-3000 and V-HRd reflect the severe intensity domain (above CV).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The code STATFLUX, implementing a new and simple statistical procedure for the calculation of transfer coefficients in radionuclide transport to animals and plants, is proposed. The method is based on the general multiple-compartment model, which uses a system of linear equations involving geometrical volume considerations. Flow parameters were estimated by employing two different least-squares procedures: Derivative and Gauss-Marquardt methods, with the available experimental data of radionuclide concentrations as the input functions of time. The solution of the inverse problem, which relates a given set of flow parameter with the time evolution of concentration functions, is achieved via a Monte Carlo Simulation procedure.Program summaryTitle of program: STATFLUXCatalogue identifier: ADYS_v1_0Program summary URL: http://cpc.cs.qub.ac.uk/summaries/ADYS_v1_0Program obtainable from: CPC Program Library, Queen's University of Belfast, N. IrelandLicensing provisions: noneComputer for which the program is designed and others on which it has been tested: Micro-computer with Intel Pentium III, 3.0 GHzInstallation: Laboratory of Linear Accelerator, Department of Experimental Physics, University of São Paulo, BrazilOperating system: Windows 2000 and Windows XPProgramming language used: Fortran-77 as implemented in Microsoft Fortran 4.0. NOTE: Microsoft Fortran includes non-standard features which are used in this program. Standard Fortran compilers such as, g77, f77, ifort and NAG95, are not able to compile the code and therefore it has not been possible for the CPC Program Library to test the program.Memory, required to execute with typical data: 8 Mbytes of RAM memory and 100 MB of Hard disk memoryNo. of bits in a word: 16No. of lines in distributed program, including test data, etc.: 6912No. of bytes in distributed Program, including test data, etc.: 229 541Distribution format: tar.gzNature of the physical problem: the investigation of transport mechanisms for radioactive substances, through environmental pathways, is very important for radiological protection of populations. One such pathway, associated with the food chain, is the grass-animal-man sequence. The distribution of trace elements in humans and laboratory animals has been intensively studied over the past 60 years [R.C. Pendlenton, C.W. Mays, R.D. Lloyd, A.L. Brooks, Differential accumulation of iodine-131 from local fallout in people and milk, Health Phys. 9 (1963) 1253-1262]. In addition, investigations on the incidence of cancer in humans, and a possible causal relationship to radioactive fallout, have been undertaken [E.S. Weiss, M.L. Rallison, W.T. London, W.T. Carlyle Thompson, Thyroid nodularity in southwestern Utah school children exposed to fallout radiation, Amer. J. Public Health 61 (1971) 241-249; M.L. Rallison, B.M. Dobyns, F.R. Keating, J.E. Rall, F.H. Tyler, Thyroid diseases in children, Amer. J. Med. 56 (1974) 457-463; J.L. Lyon, M.R. Klauber, J.W. Gardner, K.S. Udall, Childhood leukemia associated with fallout from nuclear testing, N. Engl. J. Med. 300 (1979) 397-402]. From the pathways of entry of radionuclides in the human (or animal) body, ingestion is the most important because it is closely related to life-long alimentary (or dietary) habits. Those radionuclides which are able to enter the living cells by either metabolic or other processes give rise to localized doses which can be very high. The evaluation of these internally localized doses is of paramount importance for the assessment of radiobiological risks and radiological protection. The time behavior of trace concentration in organs is the principal input for prediction of internal doses after acute or chronic exposure. The General Multiple-Compartment Model (GMCM) is the powerful and more accepted method for biokinetical studies, which allows the calculation of concentration of trace elements in organs as a function of time, when the flow parameters of the model are known. However, few biokinetics data exist in the literature, and the determination of flow and transfer parameters by statistical fitting for each system is an open problem.Restriction on the complexity of the problem: This version of the code works with the constant volume approximation, which is valid for many situations where the biological half-live of a trace is lower than the volume rise time. Another restriction is related to the central flux model. The model considered in the code assumes that exist one central compartment (e.g., blood), that connect the flow with all compartments, and the flow between other compartments is not included.Typical running time: Depends on the choice for calculations. Using the Derivative Method the time is very short (a few minutes) for any number of compartments considered. When the Gauss-Marquardt iterative method is used the calculation time can be approximately 5-6 hours when similar to 15 compartments are considered. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

1. Maximal lactate steady state (MLSS) corresponds to the highest blood lactate concentration (MLSSc) and workload (MLSSw) that can be maintained over time without continual blood lactate accumulation and is considered an important marker of endurance exercise capacity. The present study was undertaken to determine MLSSw and MLSSc in running mice. In addition, we provide an exercise training protocol for mice based on MLSSw.2. Maximal lactate steady state was determined by blood sampling during multiple sessions of constant-load exercise varying from 9 to 21 m/min in adult male C57BL/6J mice. The constant-load test lasted at least 21 min. The blood lactate concentration was analysed at rest and then at 7 min intervals during exercise.3. The MLSSw was found to be 15.1 +/- 0.7 m/min and corresponded to 60 +/- 2% of maximal speed achieved during the incremental exercise testing. Intra- and interobserver variability of MLSSc showed reproducible findings. Exercise training was performed at MLSSw over a period of 8 weeks for 1 h/day and 5 days/week. Exercise training led to resting bradycardia (21%) and increased running performance (28%). of interest, the MLSSw of trained mice was significantly higher than that in sedentary littermates (19.0 +/- 0.5 vs 14.2 +/- 0.5 m/min; P = 0.05), whereas MLSSc remained unchanged (3.0 mmol/L).4. Altogether, we provide a valid and reliable protocol to improve endurance exercise capacity in mice performed at highest workload with predominant aerobic metabolism based on MLSS assessment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It is reported in the literature that nearly 20% of rats are susceptible to displays of wild running (WR) behavior when submitted to high intensity acoustic stimulation. Some characteristics of WR suggest that it can be viewed as a panic-like reaction. This work aimed to test whether WR-sensitive rats show higher levels of anxiety in elevated-plus-maze (EPM) and predator-odor exposure paradigms in comparison with WR-resistant ones. Male adult Wistar rats were submitted to two trials of acoustic stimulation (104 dB, 60 s) in order to assess WR susceptibility. Seven WR-sensitive and 15 WR-resistant rats were evaluated by the EPM test. Other 13 WR-sensitive and 18 WR-resistant animals were submitted to the predator-odor exposure test which consisted of a 10 min-session of free exploration in a specific apparatus containing two odoriferous stimuli: cotton swab imbedded with snake cloacal gland secretion or with iguana feces (control). WR-sensitive rats presented a significantly higher closed-to open-ann-entry ratio in the EPM test. All rats responded with anxiety-like behaviors to the predator odor exposure, although the WR-sensitive ones showed a marked behavioral inhibition regardless of the odor condition. We conclude that WR-sensitive rats present elevated levels of anxiety manifested by means of passive behavioral strategies. (C) 2004 Elsevier B.V. All rights reserved.